American Standard 2732L, 2425L - V, 2422L - V, 2908L, 2771L - V User Manual

...
4 (1)
1
THANK YOU...
for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump, motor, and system piping. All you need to finish the
whirlpool installation are your selected fittings and electrical connections.
To insure maximum performance and pleasure from this product, please follow the instructions and cautions.
MODEL 2422L / V 5' x 32"
MODEL 6060L / V CORNER
MODEL 2771L / V 5' x 36"
MODEL 7236L / V 6' x 36"
MODEL 2425L / V - LHO 5' x 32" IA-LHO
MODEL 2425L / V - RHO 5' x 32" IA-RHO
MODEL 2908L REMINISCENCE
MODEL 2711L ELLISSE
MODEL 2773L CADET 6' x 36"
MODEL 2774L CADET 6' x 42"
MODEL 2775L CADET CORNER
MODEL 2732L 5' x 32"
© AS Americas Inc. 2010
All product names listed herein are trademarks
of AS Americas Inc. unless otherwise noted.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
INSTALLATION & OPERATION GUIDE FOR
EVERCLEAN
/ EVOLUTION
WHIRLPOOLS AND BATHTUBS
753737-100 Rev. E
2
753737-100 Rev. E
TABLE OF CONTENTS:
Safety Instructions...............................................................................Page 3
General Information.............................................................................Page 4
Optional Components..........................................................................Page 4
Specifications......................................................................................Page 5
Roughing-in Reference.....................................................................Page 6-9
Framing and Support Instructions.....................................................Page 10
Mounting Instructions.........................................................................Page 11
Electrical Connections.......................................................................Page 12
6060L/V Corner EZ-Install Heater.....................................................Page 13
Operation.....................................................................................Page 14-15
Drain Connection and System Test...................................................Page 16
Care and Cleaning.............................................................................Page 16
Warranty............................................................................................Page 17
753737-100 Rev. E
3
!
!
!
!
!
!
!
SAVE THESE INSTRUCTIONS
WARNING: Risk of personal injury. Do not permit children to use this unit without adult supervision.
WARNING: Risk of personal injury. Do not operate this unit without the guard over the suction fitting.
WARNING: Risk of electric shock. Do not permit electrical appliances (hair dryer, telephone, radio, etc.) within
60 inches (1524mm) of this unit.
WARNING: Risk of hyperthermia and possible drowning. People using medications and/or having adverse
medical history should consult a physician before using this product.
WARNING: Risk of personal injury. Do not overfill unit before entering. Entering tub when filled more than 2/3
can cause overflow and slippery conditions. Exercise caution when entering and exiting.
WARNING: No Food or Alcoholic Beverages. Use of your bathtub immediately after meals is not
recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or
hyperthermia resulting in loss of consciousness or even drowning.
WARNING: Pregnancy. If you are or think you may be pregnant, consult your physician before using the bathtub.
Never drop or insert any object into any opening.
Use this unit only for its intended use as described in this manual. Do not use any attachments not recommended by
American Standard.
The unit must be connected only to a supply circuit that is properly protected by a ground-fault circuit-interrupter
(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI
fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button
being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this hydromassage
bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a licensed electrician before using.
A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG solid
copper bonding conductor between this unit and all other electrical equipment and exposed metal in the vicinity, as
needed to comply with local requirements. To reduce the risk of an electric shock, connect this connector the
grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors
supplying this unit.
IMPORTANT SAFETY
INSTRUCTIONS
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, ELECTRIC SHOCK
OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!
4
753737-100 Rev. E
Everclean
/Evolution
Corner
Everclean
/Evolution
5' x 32"
Everclean
/Evolution
5' x 36"
Everclean
/Evolution
6' x 36"
Everclean
/Evolution
5' x 32" IA
Everclean
/Evolution
Oval
Everclean
Reminiscence
Everclean
Ellisse
Everclean
Cadet 6' x 36"
Everclean
Cadet 6' x 42"
Everclean
Cadet Corner
Everclean
5' x 32"
6060
2422
2771
7236
2425
2645
2908
2711
2773
2774
2775
2732
INCLUDED
NOT
AVAILABLE
9261.019
9261.019
9271.019
INTEGRAL
9266.018
NOT
AVAILABLE
NOT
AVAILABLE
9272.018
9272.018
NOT
AVAILABLE
5FT-
APRON
N/A
N/A
1599.500.020
1599.500.020*
1599.500.020*
1599.500.020*
1599.500.020*
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
1599.500.020
Optional Components
(Not Included)
Required Components
(Not Included)
E-Z
Install
Heater
Apron
Kit
Tile
Bead
Kit
1583.470.XXX
1599.205.XXX*
1599.205.XXX*
1599.205.XXX*
1599.205.XXX*
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
1583.470.XXX
Drain
(Specify
Finish)
Drain
(White)
List of Required Tools and Supplies:
Tools
• Level
Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard Woodworking Tools
• Personal Safety Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 4 Stringers
• Drop Cloth
• Cement, Plaster, Grout
General Installation Information
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your
vendor immediately. After inspection and during installation, protect the bath from construction damage. Before
installation, and before enclosing with wallboard, tile, etc., the bath must be filled with water and operated to
check for leaks that may have resulted from shipping damage or mishandling ! Do not make modifications to
the whirlpool system or remove pump from factory mounting. This could adversely affect the safety and performance
of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others.
For electrical requirements, refer to section titled “Whirlpool Electrical Installation Instructions”.
Check for availability of optional American Standard wall tiling bead (required for recess installation).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
Description
Model
Number
LIST OF OPTIONAL COMPONENTS (NOT INCLUDED):
• For these components please see your Vendor.
* These models require American Standard Lifetime™ Drain 1599.205 or 1599.500
!
WARNING: Do not lift whirlpool by the piping harness at any time.
753737-100 Rev. E
5
SPECIFICATIONS:
GENERAL SPECIFICATIONS FOR LIFETIME / EVOLUTION WHIRLPOOLS AND BATH TUBS
TABLE 1
SIDE VIEW
DRAIN / OVERFLOW
END VIEW
L
H
W
C
A
B
J
6060L / V
Corner*
2422L / V
5' x 32"
2771L / V
5' x 36"
7236L / V
6' x 36"
2425L / V
5' x 32”
LHO /
RHO
2645L / V
Oval
2908L
Reminiscence
2711L
Ellisse
2773L
Cadet 6' x 36"
2774L
Cadet 6' x 42"
2775L
Cadet Corner
2732L
5' x 32"
A 18"
(457mm)
B 13-3/4"
(349mm)
A 20-1/8"
(511mm)
B 11"
(279mm)
A 20-1/8"
(511mm)
B 11"
(279mm)
A 20-1/8"
(511mm)
B 11"
(279mm)
A 19-1/8"
(485mm)
B 10-1/2"
(266mm)
A 15-1/4"
(387mm)
B 8-1/4"
(209mm)
A 15-1/8"
(384mm)
B 13"
(330mm)
A 17-3/8"
(441mm)
B 12"
(305mm)
A 17"
(432mm)
B 12"
(305mm)
A 16-1/4"
(413mm)
B 12"
(305mm)
A 16-1/2"
(419mm)
B 11"
(279mm)
A 17-1/4"
(438mm)
B 8-1/2"
(216mm)
5-5/8"
(130mm)
3-1/4"
(83mm)
3-1/4"
(83mm)
3-1/4"
(83mm)
2-7/8"
(73mm)
1-3/4"
(44mm)
6"
(152mm)
4"
(102mm)
2-1/4"
(57mm)
2-1/4"
(57mm)
11"
(279mm)
2-5/8"
(67mm)
C 19-1/2"
(495mm)
C 20"
(508mm)
C 20"
(508mm)
C 20"
(508mm)
C 20-1/4"
(515mm)
C 18-1/4"
(464mm)
C 18-1/4"
(464mm)
C 19-1/2"
(495mm)
C 18-1/4"
(464mm)
C 18-1/4"
(464mm)
C 18-1/4"
(464mm)
C 18-1/4"
(464mm)
Template
Provided
58-1/2"
(1485mm)
x 30-1/2"
(774mm)
58-1/2"
(1485mm)
x 34-1/2"
(876mm)
70-1/2"
(1790mm)
x 34-1/2"
(876mm)
N/A
64"
(1625mm)
x 34"
(863mm)
Template
Provided
70-1/2"
(1791mm)
x 46-1/2"
(1181mm)
70-1/2"
(1791mm)
x 34-1/4"
(870mm)
70-1/2"
(1791mm)
x 40-1/2"
(1029mm)
Template
Provided
58-1/2"
(1485mm)
x 31-1/4"
(794mm)
Template
751627-400
60-3/16"
(1528mm)
x 30-1/2"
(774mm)
60-3/16"
(1528mm)
x 34-1/2"
(876mm)
72-3/16"
(1833mm)
x 34-1/2"
(876mm)
60-3/16"
(1528mm)
x 30-1/2"
(774mm)
66-3/16"
(1681mm)
x 34-1/2"
(876mm)
Template
752540-400
72-3/16"
(1833mm)
x 48"
(1219mm)
72-3/16"
(1833mm)
x 36"
(914mm)
72-3/16"
(1833mm)
x 42"
(1067mm)
Template
752539-400
60-3/16"
(1529mm)
x 31-1/4"
(794mm)
L 1949mm (76-3/4")
W 1661mm (65-3/8")
H 546mm (21-1/2")
L 1524mm (60")
W 813mm (32")
H 546mm (21-1/2")
L 1524mm (60")
W 914mm (36")
H 546mm (21-1/2")
L 1829mm (72")
W 914mm (36")
H 546mm (21-1/2")
L 1524mm (60")
W 813mm (32")
H 521mm (20-1/2")
L 1676mm (66")
W 914mm (36")
H 502mm (19-3/4")
L 1676mm (66")
W 914mm (36")
H 616mm (24-1/4")
L 1829mm (72")
W 1219mm (48")
H 546mm (21-1/2")
L 1829mm (72")
W 914mm (36")
H 502mm (19-3/4")
L 1829mm (72")
W 1067mm (42")
H 502mm (19-3/4")
L 2159mm (85")
W 1524mm (60")
H 502mm (19-3/4")
L 1524mm (60")
W 832mm (32-3/4")
H 502mm (19-3/4")
108 lb.
(49 kg.)
74 lb.
(34 kg.)
75 lb.
(34 kg.)
106 lb.
(48 kg.)
92 lb.
(42 kg.)
96 lb.
(44 kg.)
95 lb.
(43 kg.)
148 lb.
(67 kg.)
101 lb.
(45 kg.)
137 lb.
(62 kg.)
130 lb.
(59 kg.)
65 lb.
(30 kg.)
824 lb. (374 kg)/
25 lb./sq.ft.
(117 kg/sq.m)
690 lb. (313 kg)/
53 lb./sq.ft.
(260 kg/sq.m)
800 lb. (363 kg)/
53 lb./sq.ft.
(260 kg/sq.m)
1031 lb. (467 kg)/
57 lb./sq.ft.
(280 kg/sq.m)
675 lb. (306 kg)/
54 lb./sq.ft.
(262 kg/sq.m)
580 lb. (263 kg)/
36 lb./pies
cuadrados
(175 kg/sq.m)
659 lb. (299 kg)/
40 lb./sq.ft.
(191 kg/sq.m)
965 lb. (434 kg)/
40 lb./sq.ft.
(195 kg/sq.m)
751 lb. (341 kg)/
40 lb./sq.ft.
(190 kg/sq.m)
821 lb. (372 kg)/
42 lb./sq.ft.
(203 kg/sq.m)
756 lb. (343 kg)/
34 lb./sq.ft.
(115 kg/sq.m)
524 lb. (237 kg)/
43 lb./sq.ft.
(213 kg/sq.m)
N/A
Optional
Optional
Optional
Included
Optional
N/A
N/A
Optional
Optional
N/A
Optional
Included
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
86 gal.
(325 l.)
74 gal.
(280 l.)
87 gal.
(329 l.)
111 gal.
(420 l.)
70 gal.
(265 l.)
58 gal.
(219 l.)
68 gal.
(257 l.)
95 gal.
(360 l.)
78 gal.
(296 l.)
82 gal.
(310 l.)
75 gal.
(284 l.)
55 gal.
(208 l.)
71 gal.
(269 l.)
33 gal.
(125 l.)
50 gal.
(189 l.)
53 gal.
(201 l.)
39 gal.
(148 l.)
42 gal.
(159 l.)
55 gal.
(208 l.)
74 gal.
(280 l.)
64 gal.
(243 l.)
66 gal.
(256 l.)
60 gal.
(272 l.)
47 gal.
(155 l.)
Description
Drain /
Overflow
Cut Out
Pier
G x F
Rough-In
Recess
E x D
Tub Edge to
Centerline
Overflow: J
Weight with
Water / Floor
Loading
Product
Weight
Apron /
Mounting
Heater Ready
for Field
Installation
Gallon to
Overflow
Whirlpool
Operating
Volume
Height to
Underside
of Deck: C
Dimensions
L-W-H
6
753737-100 Rev. E
DIMENSIONS OF FIXTURES ARE NOMINAL AND MAY VARY WITHIN THE RANGE
OF TOLERANCES ESTABLISHED BY ANSI STANDARDS Z124.1 AND A112.19.7.
ROUGHING-IN REFERENCES
5' x 32" (MODEL 2422L / V)
60"
(1524mm)
36"
(914mm)
3"
(76mm)
7-1/2"
(191mm)
11"
(279mm)
13-3/4"
(349mm)
CUT OUT IN FLOOR
FOR DRAIN
5' x 36" (MODEL 2771L / V)
72"
(1829mm)
36"
(914mm)
7-3/4"
(197mm)
11"
(279mm)
3-1/4"
(83mm)
3"
(76mm)
6"
(152mm)
13-3/4"
(349mm)
CUT OUT IN FLOOR
FOR DRAIN
6' x 36" (MODEL 7236L / V)
60"
(1524mm)
32"
(813mm)
11"
(279mm)
7-3/4"
(197mm)
13-3/4"
(349mm)
6"
(152mm)
3"
(76mm)
3-1/4"
(83mm)
CUT OUT IN FLOOR
FOR DRAIN
3-1/4"
(83mm)
6"
(152mm)
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
PROVIDE
ACCESS TO
PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
Loading...
+ 11 hidden pages