®SurgeArrest® Surge Protector
www.apc.com |
+ Battery Backup (BE325-UK) |
|
User’s Manual |
Connect Battery
The APC SurgeArrest Surge Protector + Battery Backup is shipped with the battery disconnected. The unit will not operate until the battery is connected. NOTE: Small sparks may occur during battery connection. This is normal.
1 |
2 |
3 |
4 |
5 |
Connect Equipment |
|
32 - 104oF (0 - 40oC)
Battery Backup + Surge Protection
These outlets are powered whenever the unit is switched ON. During a power outage or other utility problems (brownouts, overvoltages), these outlets will be powered for a limited time by the internal battery. Plug your computer and 17” (or smaller) monitor, into these two outlets.
Connect FAX/Modem/Phone
The unit protects a single line (2-wire) fax, modem or phone from surges when it is connected as shown below.
Connect AC Line Cord
Connect the AC line cord to a 230-volt outlet.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Surge Protector |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
+ Battery Backup |
|||||||||||
|
|
|
|
|
w w w.apc.com |
|
|
|
|
|
|
|
325VA |
Battery Backup plus Surge Protection
Top View
Surge Protection
These outlets provide full-time protection from surges even if the unit is switched OFF. Plug your printer, fax machine, scanner, or other peripheral that does not need battery power into these outlets.
egruSnoitcetorP
Fax/Modem/Phone
Telephone Wall
Outlet
230-Volt Wall
Outlet
RJ-11
Connectors
End View
AC Line |
|
Circuit |
Cord |
Circuit Breaker |
|
|
|
|
|
|
Breaker |
|
Push to Reset |
|
End View
Side View
Status Indications
Power On
The Surge Protector + Battery Backup should be allowed to charge for at least 16 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, and the unit is turned ON.
Power ON the unit by pressing the ON/OFF button. Turn on your equipment.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Surge Protector |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
+ Battery Backup |
|||||||||||
|
|
|
|
|
w w w.apc.com |
|
|
|
|
|
|
|
325VA |
Battery Backup plus Surge Protection
Top View
Note: The on/off switch is illuminated when in the ON position. The switch may flash to indicate changing power conditions (see Status Indications).
The Surge Protector + Battery Backup provides status indications through the flashing of the “Power On” indicator, as well as audible beeps. The indications are as follows:
Status |
Visual Indications |
Audible |
Alarm Terminates |
|
|
Indication |
When |
|
|
|
|
On Line - Unit is supplying |
Power On LED - ON |
None |
n/a |
conditioned utility power to your |
|
|
|
equipment |
|
|
|
|
|
|
|
On Battery - Unit is supplying battery |
Power On LED - ON |
Beeping 4 times |
Unit returns to an On |
power to the equipment connected to |
(off during beep) |
every 30 seconds |
Line status or when |
the battery powered outlets |
|
|
the unit is turned off. |
|
|
|
|
Low Battery Warning - Unit is |
Power On LED - |
Rapid beeping |
Unit is turned OFF, |
supplying battery power and the |
Flashing |
(one second |
returns to On Line or |
battery is nearly depleted. Once |
|
intervals) |
when the battery is |
depleted, the unit will turn off. |
|
|
finally exhausted and |
|
|
|
the unit turns off. |
|
|
|
|
Replace Battery - Battery may need |
Power On LED - |
Continuous tone. |
Unit is turned OFF |
to be replaced, or the battery is not |
Flashing |
|
and then ON and it |
connected. |
|
|
passes a subsequent |
|
|
|
battery test. (This test |
|
|
|
occurs automatically |
|
|
|
whenever the unit is |
|
|
|
turned ON and every |
|
|
|
14 days) |
|
|
|
|
Overload Shutdown - During On |
Power On LED - |
Continuous tone. |
Unit is turned off |
Battery operation a battery-power |
OFF |
|
using the ON/OFF |
outlet was overloaded. |
|
|
button. |
|
|
|
|
990-2124 Copyright © 2003 American Power Conversion. All rights reserved. |
APC is a registered trademark of American Power Conversion |
|
All other trademarks are property of their respective owners. |