American Dryer Corp. AD-385 User Manual

0 (0)

WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.

-Do not store or use gasoline or other flammable vapor and liquids in the vicinity of this or any other appliance.

■WHAT DO YOU DO IF YOU SMELL GAS

*Do not try to light any appliance.

*Do not touch any electrical switch; do not use any phone in your building.

*Clear the room, building or area of all occupants.

*Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

*If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency or the gas supplier.

AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice poiff réduire au minimiim le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.

■Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.

■ QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

*Ne pas tenter d’allumer d’appareil.

*Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous vous trouvez..

*Évacuez la pièce, le bâtiment ou la zone.

*Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

*Si vous ne pouvez rej oindre le fournisseur de gaz, appelez le service des incendies.

-L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.

JOC^

American Dryer Corp.

111298SL/abe

For replacement parts, contact the distributor from which the dryer was purchased or

American Dryer Corporation 88 Currant Road

FaU River MA 02720-4781

Telephone: (508)678-9000 / Fax: (508)678-9447 E-mail: techsupport@amdry.com

ADC Part No. 112188

American Dryer Corp. AD-385 User Manual

Retain This Manual In A Safe Place For Future Reference

American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation.

ONLY qualified technicians should service this equipment.

OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation/operator's manual included with the dryer.

The following “FOR YOUR SAFETY” caution must be posted near the dryer in a prominent location.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

POUR VOTRE SÉCURITÉ

Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de yout autre appareil.

We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.

Important

For your convenience, log the following information:

DATE OF PURCHASE

MODEL NO.

AD-385

DISTRIBUTORS NAME

Serial Number(s) ______

Replacement parts can be obtained from your distributor or the ADC factory. When ordering replacement parts from the factory, you can FAX your order to ADC at (508) 678-9447 or telephone your orders directly to the ADC Parts Department at (508) 678-9000. Please specify the dryer model number and serial number in addition to the description and part number, so that your order is processed accurately and promptly.

The illustrations on the following pages may not depict your particular dryer exactly. The illustrations are a composite of the various dryer models. Be sure to check the descriptions of the parts thoroughly before ordering.

“IMPORTANTNOTE TO PURCHASER”

Inforaiation must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer.

IMPORTANT

YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUST­ ING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS.

“Caution:

Label

all

wires

prior

to

diseonnection

when

servicing controls. Wiring

errors can cause improper operation.”

 

 

«Attention:

Lor

des

opérations

d’entretien

des

commandes

étiqueter tous

fils

avant

de

les

déeonneeter.

Toute

erreur

de

câblage peut être une source de danger et dépanné.»

CAUTION

DRYER(S) SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.

]

 

WARNING

CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON ORNEARTHE DRYER(S). CHILDREN SHOULD M SUPERVISED IF NEAR DRYER(S) IN OPERATION.

FOR YOUR SAFETY

DO NOT DRYMOP HEADS IN THE DRYER.

DO NOT USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.

WARNING

UNDER NO CIRCUMSTANCES should the door switch or the heat circuit devices ever be disabled.

WARNING

The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RESULT.

WARNING

DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE...EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED.

IMPORTANT

PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation/operator's manual included with the dryer.

Dryer(s) must not be installed or stored in an area where it will be exposed to water and/or weather.

^ The wiring diagram for the dryer is located in the front electrical control bc№

area.

J

 

 

Table of Contents

SECTION I

 

IMPORTANT INFORMATION..................................................................................

3

A. RECEIVING and HANDLING...................................................................................................................

3

B. SAFETY PRECAUTIONS...........................................................................................................................

4

SECTION II

 

SPECIFICATIONS/COMPONENT IDENTIFICATION...........................................

6

A. SPECIFICATIONS.....................................................................................................................................

6

SECTION III

 

INSTALLATION PROCEDURES............................................................................

8

A. LOCATION REQUIREMENTS...................................................................................................................

8

B. UNPACKING/SETTING UP........................................................................................................................

9

C DRYER ENCLOSURE REQUIREMENTS.................................................................................................

10

D. FRESH AIR SUPPLY................................................................................................................................

11

E. EXHAUST REQUIREMENTS...................................................................................................................

13

F. ELECTRICAL INFORMATION...............................................................................................................

18

G. GAS INFORMATION...............................................................................................................................

23

H. PREPARATION FOR OPERATION/START-UP....................................................................................

26

I. PREOPERATIONAL TESTS......................................................................................................................

27

J. PREOPERATIONAL INSTRUCTIONS.....................................................................................................

29

K. SHUT DOWN INSTRUCTIONS...............................................................................................................

31

SECTION IV

 

SERVICE/PARTS INFORMATION........................................................................

32

A. SERVICE...................................................................................................................................................

32

B. PARTS........................................................................................................................................................

32

SECTION V

 

WARRANTY INFORMATION................................................................................

33

A. RETURNING WARRANTY CARD(S)...................................................................................................

33

B. PARTS.......................................................................................................................................................

33

C RETURNING WARRANTY PARTS.........................................................................................................

33

SECTION VI

 

ROUTINE MAINTENANCE....................................................................................

35

A. CLEANING...............................................................................................................................................

35

B. ADJUSTMENTS........................................................................................................................................

36

C. LUBRICATION.........................................................................................................................................

36

SECTION VII

 

TROUBLESHOOTING.............................................................................................

37

Microprocessor (Coin) Models........................................................................................................................

38

Mechanical (Coin) Meter Models...............................................................................................................

42

(OPL) Microprocessor (Computer) Models.....................................................................................................

47

Dual Timer (OPL) Models..........................................................................................................................

55

SECTION VIII

 

TECHNICAL INFORMATION...............................................................................

60

SECTION IX

 

PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS................................

62

SECTION I

IMPORTANT INFORMATION

A. RECEIVING and HANDLING

The dryer is shipped in a protective stretch wrap cover with protective cardboard comers and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves.

Dryers damaged in shipment.

1.ALL dryers should be inspected upon receipt and before they are signed for.

2.If there is suspected damage or actual damage, the trucker's receipt should be so noted.

3.If the dryer is damaged beyond repair, it should be refused. Those dryers which were not damaged in a damaged shipment should be accepted, but the number received and the number refused must be noted on the receipt.

4.If you determine that the dryer was damaged after the trucker has left your location, you should call the delivering carrier's freight terminal immediately and file a claim. The freight company considers this concealed damage. This type of freight claim is very difficult to get paid and becomes extremely difficult when more than a day or two passes after the freight was delivered. It is your responsibility to file freight claims. Dryer/parts damaged in transit

cannot be claimed under warranty

5.Freight claims are the responsibility of the consignee, and ALL claims must he filed at the receiving end. ADC assumes no responsibility for freight claims or damages.

6.If you need assistance in handling the situation, please contact the ADC Traffic Manager at

(508)678-9000.

IMPORTANT; The dryer must he transported and handled in an upright position at all times.

B. SAFETY PRECAUTIONS

WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life.

WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD

____________ RESULT.________________________________________________________

1.DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

2.Purchaser/user should consult the local gas supplier for proper instructions to be followed in the event the user smells gas. The instructions should be posted in a prominent location.

3.WHAT TO DO IF YOU SMELL GAS...

a.DO NOT try to light any appliance.

b.DO NOT touch any electrical switch.

c.DO NOT use any phone in your building.

d.Clear the room, building, or area of ALL occupants.

e.Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

f.If you cannot reach your gas supplier, call the fire department.

4.Installation and service must he preformed by a qualified installer, service agency, or gas supplier.

5.Dryer(s) must be exhausted to the outdoors.

6.Although ADC produces a very versatile machine, there are some articles that, due to fabric composition or cleaning method, should not be dried in it.

WARNING; Dry only water-washed fabrics. DO NOT dry articles spotted or washed

in dry cleaning solvents, a combustible detergent, or "all purpose" cleaner. EXPLOSION COULD RESULT.

WARNING; DO NOT dry rags or articles coated or contaminated with gasoline,

______________kerosene, oil, paint, wax. EXPLOSION COULD RESULT.

WARNING; DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard.

WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket

______________(tumbler) may damage plastics or rubber and also may be a fire hazard.

7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust duct work, and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each location.

WARNING: The collection of lint in the burner area and exhaust duct work can create a potential fire hazard.

8. For personal safety, the dryer must he electrically grounded in accordance with local codes and/or the National Electric Code ANSI/NFPA NO. 70-LATEST EDITION.

NOTE: Faüure to do so will VOID THE WARRANTY.

9. UNDER NO CIRCUMSTANCES should the dryer door switches, heat safety circuit, ever be disabled.

WARNING: PERSONAL INJURY or FIRE COULD RESULT.

10.This dryer is not to be used in the presence of dry cleaning solvents or fumes.

11.Remove articles from the dryer as soon as the drying cycle has been completed.

WARNING: Articles left in the dryer after the drying and cooling cycles have been completed can create a fire hazard.

12. READ and FOLLOW ALL CAUTION and DIRECTION LABELS ATTACHED TO THE DRYER.

WARNING: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS.

SECTION II

SPECIFICATIONS/COMPONENT IDENTIFICATION

A. SPECIFICATIONS

MAXIMUM CAPACITY (DRY WEIGHT)

30 lbs.

 

13.6 kg

BASKET (TUMBLER) DIAMETER

27-1/4"

 

69.22 cm

BASKET (TUMBLER) DEPTH

30"

 

76.2 cm

BASKET (TUMBLER) MOTOR

1 HP

 

.746 kw

DOOR OPENING (DIAMETER)

21-1/2"

 

54.61 cm

BASKET (TUMBLER) VOLUME

10.12 cu. ft.

 

.286 cum.

DRYERS PER 20V40' CONTAINER

 

14/30

DRYERS PER 45748' TRUCK

 

36/38

 

VOLTAGE AVAILABLE

120-230V / 10/ 50/60 Hz

tn

APPROX WEIGHT (UNCRATED)

450 lbs.

 

204 kg

APPROX WEIGHT (CRATED)

500 lbs.

 

227 kg

 

 

o

HEAT INPUT

110,000 btuh

 

27,721 kcal/hr

 

AIRFLOW

750 cfin

 

21.22 cmm

 

INLET PIPE CONNECTION

3/4"

 

1.91 cm

 

 

 

 

 

Shaded

areas are in metric equivalents

 

 

 

NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation.

Specifications

ADG-385

lSPEC<5f|

FRONT VIEW

SECTION III

INSTALLATION PROCEDURES

Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: National Fuel Gas Code ANSI.Z223.1-LATEST EDITION and/or National Electric Code ANSI/NFPA NO. 70-LATEST EDITION.

A. LOCATION REQUIREMENTS

Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence-of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1-LATEST EDITION.

1.The dryer must be installed on a sound level floor capable of supporting its weight. It is recommended that carpeting be removed from the floor area that the dryer is to rest on.

2.The dryer must not he installed or stored in an area where it will be exposed to water and/or weather.

3.Provisions for adequate air supply must be provided as noted in this manual (refer to Fresh Air Supply in Section Dl.

4.Clearance provisions must be made from combustible construction as noted in this manual (refer to Dryer Enclosure Requirements in Section O.

5.Provisions must be made for adequate clearances for servicing and for operation as noted in this manual (refer to Dryer Enclosure Requirements in Sectiom O.

6.Dryer must be exhausted to the outdoors (refer to Exhaust Requirements in Section EL

7.Dryer must be located in an area where correct exhaust venting can be achieved as noted in the manual (refer to Exhaust Requirements in Section EL

IMPORTANT: Dryer should be located where a minimum amount of exhaust duct will

________________ be necessary. ___________________________________

B. UNPACKING/SETTING UP

Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer.

LOCKS/KEYS

Coin Models: The access keys to the control (service) door, and lint door are included inside the information package shipped in the dryer tumbler (basket) and should be removed and put in a safe place. The keys should be made accessible because they will be needed throughout various phases in the installation of the unit.

OPL Models: For models equipped with locks, the lock used is a dummy lock and no key is supplied or needed. The lock can be turned with any key, a screwdriver, a small coin, or any small sharp object.

The dryer can be moved to its final location while still attached to the skid or with the skid removed. To un-skid the dryer, locate and remove the four (4) bolts securing the base of the dryer to the wooden skid. Two (2) are at the rear base (remove the back panel for access), and two (2) are located in the bottom of the lint chamber. To remove the two (2) bolts located in the lint chamber area, remove the lint door.

With the skid removed, to make it easier to slide the dryer into its final position, slightly lower ALL four (4) leveling legs, so that the dryer will slide on the legs instead of the base frame.

To increase bearing life and improve efficiency, and for better automatic closure of the main door the dryer should be tilted slightly to the rear.

C. DRYER ENCLOSURE REQUIREMENTS

Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of twelve (12) inches (18-inches or more is recommended for ease of installation, maintenance, and service) above the dryer outer top, except along the front of the dryer which may be partially closed in if desired.

X= 12", 24" is recommended for ease of maintenance.

NOTE: Allowances must be made for opening the control door.

Dryers may be positioned side wall to side wall. However, a 1/16" minimum allowance must be made for opening and closing of the control door and the lint door. It is suggested that the dryer be positioned about two (2) feet away from the nearest obstruction for ease of installation, maintenance, and service (to be measured from the back guard). Refer to the illustration above for details.

NOTE: Air considerations are important for proper and efficient operation.

10

D. FRESH AIR SUPPLY

When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished front the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. Ignition problems and sail switch "fluttering" problems may result, as well as premature motor failure from overheating.

Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet is required for each dryer. To compensate for the use of registers or louvers used over the openings, this make-up air must be increased by approximately thirty-three percent (33%). It is not necessary to have a sepa­ rate make-up air opening for each dryer. Common make-up air openings are acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to ALL the dryers.

EXAMPLE: For a bank of four (8) dryers, two (2) unrestricted openings measuring 2 feet by 3 feet (6 square feet each) is acceptable.

1

 

MAKE UP AIR OPENINGS

 

2'

 

2‘

 

 

 

 

 

 

 

 

)

 

 

 

1

 

 

 

— 3'^

 

 

TYPICAL INSTALLATION SHOWING MAKE - UP AIR OPENINGS

11

NOTE: Make-up air openings should not be located in an area directly near where exhaust vents exit the building.

Allowances must be made for remote or constricting passageways or where dryers are located at excessive altitudes or predominantly low pressure areas.

IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvents fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage the motors and other dryer components.

NOTE; Component failure due to dry cleaning solvent fumes will VOID THE

WARRANTY.

12

E. EXHAUST REQUIREMENTS

Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats.

CAUTION: DRYER MUST BE EXHAUSTED TO THE OUTDOORS.

CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HAZARD.

The duct work should be laid out in such a way that the duct work travels as directly as possible to the outdoors with as few turns as possible. Single or independent dryer venting is recommended.

The dryer is manufactured with an 8" exhuast duct outlet. When single drying venting is used an 8" exhaust duct can be used providing that the duct work from the dryer to the outside exhaust outlet does not exceed ten (10) feet and there is no more than one (1) elbow (which is the outside exhaust outlet protection). See illustraion A on page 14 for details. For exhaust ducting which exceeds ten (10) feet, the minimum diameter of this duct must be at least 10 inches (even though the dryer exhaust duct outlet is only 8"). See illustrations B and C on page 15 for examples. In the case of multiple (common) dryer venting, the distance from the last dryer to the outside exhaust duct outlet should not exceed twenety (20) feet. The shape of the duct work is not critical so long as the minimum cross-sectional area is provided. It is sug­ gested that the use of 90 degree turns be avoided; use 30 degree and/or 45 degree angles in­ stead. The radius of the elbows should prefereably be 1-1/2 times the diameter of the duct. Including basket (tumbler)/dryer elbow connections or elbows used for outside protection from the weather, no more than two (2) elbows should be used in the exhaust run. If more than two (2) elbows are used, the cross sectional area of the duct work must be increased.

ALL duct work should be smooth inside with no projections from sheet metal screws or other obstructions which will collect lint. When adding ducts, the duct to be added should overlap the duct to which it is to be connected. ALL duct work joints must be taped to prevent moisture and lint from escaping into the building. Inspection door should be installed at strategic points in the exhaust duct work for periodic inspection and clean-out of lint from the duct work.

IMPORTANT; Exhaust back pressure measured by a manometer in the exhaust duct should not exceed 0.3 inches of water column.

IMPORTANT: For exhaust runs over 10 feet, minimum duct work diameter is 10-inches.

NOTE: Where the exhaust duct work passes through a wail, ceiling, or roof made of

combustible materials, the opening must be 2-inches larger (all the way around) than the duct. The duct must be centered within this opening.

13

To protect the outside end of horizontal duct work from the weather, a 90° elbow bent downweird should be installed where the exhaust exits the building. If the duct work travels vertically up through the roof, it should be protected from the weather by using a 180° turn to point the opening downward. In either case, allow at least twice the diameter of the duct between the duct opening and the nearest obstruction.

IMPORTANT: DO NOT use screens or caps on the outside of opening of exhaust duct work.

IMPORTANT: Exhaust back pressure measured by a manometer at each basket

(tumbler) exhaust duct area should not exceed 0.3 inches of water column.

SINGLE DRYER VENTING

IMPORTANT: For exhaust duct runs of over 10 feet a minimum duct size of 10-inches must be used.

When single 8-inch venting is used, the duct work from the dryer to the outside outlet cannot exceed 10 feet (refer to Ulus. A below). This calculation of 10 feet compensates or allows for the use of a maximum of only one (1) elbow (which is the outside outlet protection).

Ilus. A.

HORIZONTAL SINGLE DRYER

VENTING 8 INCH DUCTING

10 FEET MAXIMUM-

MAN1571

2x0

MOTE A: OPEMII^ ttlST BE ЛУ0 <21 INCHES LARGER THAN THE OUCT lALL THE WAY AROUND)

THE ШСТ MUST BE CENTERED WITHIN THIS OPENING.

14

When single 10-inch vertical venting is used( refer to Ulus. B. below), the duct work from the dryer to the outside outlet cannot exceed 20 feet. This calculation of 20 feet compensates or allows for the use of a maximum of only two (2) elbows creating the 180® (turned downward) outside outlet.

VERTICAL SINGLE DRYER VENTING

lUus. B.

Uo-X

Л • и

J

яттнАот

isecTVHsee v wvmw mn

-голтоист

ноте ЛгOPSHNQMUST КTWO 01 HCt€5LAWCB9 ГНАМOUCT<AUTf€W*f ЛтЛЯ» OUCTwtat aeСЕНтЕяеогнв опша

For a 10-inch horizontal run where a maximum of one (1) elbow is used (refer to Ulus. C below); the duct work from the dryer outlet should not exceed 50 feet. A 10-inch horizontal duct where (3) elbows (including outside outlet protection) are used cannot exceed 30 feet in length.

Ulus. C.

HORIZONTAL SINGLE DRYER

VENTING 10 INCH DUCTING

 

sofeer HAxHjH^

нотеA.- OPSHNO MUSTae TWOФic>cs LMGEP THAN rw DUCT MU WAY ллемо »c OUCT MUST ee сентекоWITMN THS OKUNQ.

If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross area of the duct work must be increased in proportion to the number of elbows or duct run added.

IMPORTANT: For extended duct work runs, the cross section area of the duct work can only be increased to an extent. When the duct work approaches the maximum limits noted in this manual, a professional heating venting air conditioning (HVAC) firm should be consulted for proper venting information.

15

MULTIPLE DRYER (Common) VENTING

If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be channeled into a "common main duct." The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of air flow and should be spaced at least 28-1/2 inches apart. The main duct should be tapered, with the diameter increasing before each individual duct (10-inch minimum) is added.

The main duct may be any shape so long as the minimum cross section is provided. The main duct should be tapered with the diameter increasing before each individual 10-inch duct is added (refer to Ulus. D below).

Illus. D.

 

MULTPLE DRYER VENTH6

 

 

 

 

 

 

WITH AH -A- OlAHETER EXHAUST COHHECTIOHS AT COMHOH DUCT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HO.OF DRYERS

S

 

7

 

A

s

 

 

3

2

i

 

 

 

 

"Rffomfuss--------------------

8

 

0

 

F

H

 

J

L

H

R

 

J£RT£^

 

 

 

 

 

 

 

 

 

JSSjumBBum_____________

C

 

E

 

a

1

 

K

M

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHOULDHOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXCEEDX"

 

 

 

 

 

 

 

 

 

 

 

L-y

U.

HOTE A-

 

 

 

 

 

 

 

 

 

 

 

-1

 

 

 

 

 

 

 

 

 

 

 

 

 

MOTEA -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*DU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

t

HQRIZOUTM.

M* iMMOJ

 

 

 

 

 

 

 

 

 

 

 

HSPECWH H

V.«v*

 

 

 

 

 

 

 

 

 

 

 

 

J

 

 

 

 

 

 

 

 

 

 

 

ODORS

 

TOHXyOJALTUMBLERS

 

 

 

 

 

 

 

 

 

 

 

MR iSiSJ asTAHces

 

 

 

 

 

 

 

 

 

 

 

 

 

nmSR EXHAUST MUST ENTER MAH

 

 

 

 

 

 

 

 

 

WALL

EXHAUST DUCT AT AUS* AMGLE

 

 

 

 

 

 

 

 

 

 

 

aermn oucrs

 

2*0 CLEARAHCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HPORTMT:nononeTMN I ORTERS CAHKCIHeCTeO roOW COMEW oucrI Y0ir I WITHA HOnaonrAi M

 

 

 

 

 

----------- ^ AW NO NDRE THAN 6OTrim CANB£COteCTEO WITH AfiRTKAi RIM

 

 

 

 

 

 

 

 

 

NOTE/»; OPEHNO Husr BETWO ffl NO€S LARGER THANOUCTlALL THEWAY AROUNDLTW DUCT

 

 

 

 

 

---------- HUST BECENTERED WITHM THSOPEHNG.

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE B:AD-3B5 2B VJ-WVE XSOCFH

 

 

 

 

 

 

 

 

 

 

 

NAN2»»

 

M. aiowns

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B=400

 

F=324

 

 

 

 

J=256

 

 

 

N=164

 

C=22

 

G=20

 

 

 

 

K=18

 

 

 

0=14

 

D=324

 

H=256

 

 

 

 

L=210

 

 

 

P=80

 

E=20

1=18

 

 

 

 

M=16

 

 

 

Q=10

 

The maximum length of venting from the last dryer to where it exhausts...

Vertical venting run must not exceed 20 feet. This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating 180° (turned downward) outside outlet.

IMPORTANT: No more than six (6) dryers maximum should be converted to one (1) main common duct with a venical run.

Horizontal venting must not exceed 20 feet. This calculation compensates for the use of a maximum of only one (1) elbow which is the outside outlet protection.

IMPORTANT: No more than eight (8) dryers maximum should be converted to one (1) main common duct with a horizontal run.

16

NOTE; Distance between dryer single ducts being connected to the main common duct must be a minimum of 28-1/2" (dryer width).

Duct work should be laid out in such in a manner where allowances are made at rear area of dryer for removal of rear service panels/guards.

Illustration D (refer to page 16) shows the minimum cross-section area for multiple dryer venting. These figures must be increased in proportion if the main duct run from the last dryer to where it exhausts has numerous elbows or is unusually long.

IMPORTANT: For extended duct work runs, the cross section area of the duct work can only be increased to an extent. When the duct work approaches the maxi­ mum limits as noted in this manual, a professional HVAC firm should be consulted for proper venting HVAC from should be consulted for proper venting information.

IMPORTANT VENTING REMINDERS

1.Duct work size and installation should be done by a qualified professional.

2.The dryer must be exhausted to the outdoors.

3.Duct work should be routed as short as possible to the outdoors with as few elbows as possible.

4.Avoid 90° turns ... use 30° or 45° turns instead.

5.The size of the duct work must be a minimum of 10-inches if the exhaust length exceeds 10 feet.

6.The inside of the duct work should be as smooth as possible ... with no projections from sheet metal screws.

Ducts added should overlap the duct to which it is to be connected.

7.ALL ducts should be taped to prevent moisture and lint from escaping into the building.

8.Inspection/clean out doors should be installed throughout strategic points in the duct work for periodic inspection and cleaning.

9.Wherever the duct passes throughout combustible materials, the opening must be 2-inches larger (all the way around) than the duct. The duct must be centered within this opening.

17