Amana UXG7480V, UXG7360V User Manual

0 (0)
Amana UXG7480V, UXG7360V User Manual

Wall-Mount Canopy Grill Vent Hood

PRODUCT MODEL NUMBERS

UXG7360V

UXG7480V

Electrical: 120-volt, 60-Hz, AC-only, 15-amp fused electrical circuit is required.

LOCATION REQUIREMENTS

Canopy grill vent hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Venting methods

This canopy grill vent hood is factory set for venting through the roof or through the wall. A 10" (25.4 cm) round vent system is needed for installation (not included). The hood exhaust opening is 10" (25.4 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance. Vent system can terminate either through the roof or through the wall. To vent through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

Roof Venting

Wall Venting

 

C

 

 

B

B

C

 

A

A

 

D

 

D

A. Optional decorative duct cover

A. Optional decorative duct cover

B. 10" (25.4 cm) round vent

B. 10" (25.4 cm) round vent and

C. Roof cap

elbow

D. 10" (25.4 cm) round vent

C. Wall cap

transition

D. 10" (25.4 cm) round vent

 

transition

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

10" (25.4 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

90° elbow

5.0 ft

 

(1.5 m)

Maximum equivalent vent length is 35 ft (10.7 m).

PRODUCT DIMENSIONS

Vented installations

12"

(30.

18" (45.7 cm)

4" (10.2 cm)

30" (76.2 cm)

24"

36"

(91.4 cm)

(61.0 cm)

48"

(121.9 cm)

 

INSTALLATION DIMENSIONS

 

 

*NOTE:The grill vent hood

 

 

duct cover is designed to add

 

 

12" (30.5 cm) to meet the

 

 

ceiling or soffit height.

A

X

Depending on your model,

order:

Part Number W10153151 for 30" (76.2 cm) models,

Part Number W10153152 for 36" (91.4 cm) models,

Part Number W10153153 for 48" (121.9 cm).

IMPORTANT:

Minimum distance “X”: 30" (76.2 cm)

Suggested maximum distance “X”: 36" (91.4 cm)

Example vent system

90 elbow

 

 

 

 

 

 

Wall cap

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft

(0.6 m)

The following example falls within the maximum recommended vent length of 35 ft (10.7 m).

1

- 90° elbow

= 5.0 ft (1.5 m)

1

- wall cap

= 0.0 ft (0.0 m)

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

Length of system

= 13.0 ft (3.9 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10153187

Instructions packed with product. Specifications subject to change without notice.