PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information.
|
PBC |
09 3 E |
35 A X |
A A |
||||
|
|
|
|
|
|
|
|
|
BASIC MODEL TYPE |
|
|
|
|
MAJOR/MINOR |
DESIGN REV. |
||
PBC = Standard Cooler TTW |
|
|
|
|
|
|
||
PBE = Electric Heat TTW |
|
|
|
|
|
|
||
PBH = Heat Pump TTW |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
COOLING CAPACITY |
|
|
|
|
|
|
||
09 |
= 9000 BTUH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
12 |
= 12000 BTUH |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
RATED VOLTAGE
2 = 115V 60Hz 1Ph
3 = 230/208V 60Hz 1Ph
DESIGN SERIES (Refrig) |
|
|
|
|
A = R-22 |
|
|
|
|
E = R-410A |
|
|
|
FEATURE CODE |
|
|
|
|
MA = Standard Model R-22 |
|
HEATER SIZE |
|
AX = Standard Model R-410A |
|
|
00 = no electric heat |
|
|
|
|
35 = 3.5 kw (230/208V) |
|
|
|
|
|
|
|
|
Use up to 4 as needed
In alphabetical order
HIGH VOLTAGE!
WARNING Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
WARNING |
Goodman will not be responsible |
|
for any injury or property damage |
arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.
WARNING ONLY individuals meeting (at a minimum) the requirements of
an "Entry Level Technician" as specified by the AirConditioning, Heating, and Refrigeration Institute (AHRI) may use this information. Attempting to install or repair this unit without such background may result in product damage, personal injury, or death.
2
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information.
PBC092E00AX
PBC122E00AX
PBC093E00AX
PBC123E00AX
PBE093E35AX
PBE123E35AX
PBH092E12AX
PBH093E35AX
PBH113E35AX
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR
INSTALLING THIS UNIT. MULTIPLE POWER
SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH.
WARNING |
The United States Environmental Protection Agency (“EPA”) has issued various regulations re- |
garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow |
|
|
these regulations may harm the environment and can lead to the imposition of substantial fines. |
|
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office. |
|
|
WARNING |
Do not connect or use any device |
that is not design certified by |
|
|
Goodman for use with this unit. |
Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.
WARNING To prevent the risk of property damage, personal injury, or death,
do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.
3
PRODUCT DESIGN
PBC, PBE and PBH through-the-wall room air conditioners are designed for window installations in residential applications and are available in 9,000 through 18,000 BTUH sizes. They are designed for 208/230/115 volt single phase applications.
The provided filter must be installed and under no circumstances should the unit be operated without the filter in place.
Location and Clearances
Be sure electrical service is adequate for chosen model of air conditioner or heat pump. Complete electrical rating for unit is found on serial plate located behind front grille. Electrical outlet must be close enough to unit for power cord to reach without strain.
Air conditioner should be the only appliance on individual circuit.
For personal safety and to avoid possible damage to appliance or home, observe all safety instructions.
NOTES:
1.Mechanical experience is required to install the air conditioner or heat pump.
2.Installation can take from 1 to 3 hours, depending on installer’s knowledge and skill.
3.If you encounter problems during installation, call our consumer information line toll-free at 1-877-376-0214 (U.S. and Canada only). If your problem cannot be resolved by phone, contact an authorized Amana® brand servicer.
Contact and service will be at your expense.
4
SPECIFICATIONS |
|
|
PBC***E00AX |
||
|
|
|
|
|
|
MODEL |
PBC092E00AX |
PBC122E00AX |
PBC093E00AX |
PBC123E00AX |
|
|
|
|
|
|
|
Cooling (BTU's) |
9200 |
11800 |
9200 |
11800 |
|
8900 |
11400 |
||||
|
|
|
|||
@ EER |
9.8 |
9.4 |
9.8 |
9.8 |
|
Cooling Watts |
940 |
1260 |
940 - 910 |
1200 - 1160 |
|
Cooling Amps |
8.6 |
11.6 |
4.4 - 4.7 |
5.6 - 6.0 |
|
|
|
|
|
|
|
Voltage |
115 |
115 |
230 -208 |
230 -208 |
|
|
|
|
|
|
|
Plug Type |
Parallel |
Parallel |
Tandem |
Tandem |
|
Power Cord Rating |
15 amp |
15 amp |
15 amp |
15 amp |
|
Power Cord Type |
LCDI |
LCDI |
LCDI |
LCDI |
|
Power Cord length |
8 feet |
8 feet |
6 feet |
6 feet |
|
|
|
|
|
|
|
Dehumidification: pints / hour |
41 oz./hr |
55 oz./hr |
41 oz./hr |
55 oz./hr |
|
Fan Speeds |
|
|
|
|
|
CFM cooling : High-Low |
275 |
275 |
275 |
275 |
|
Fan Only Speed |
3 Speed |
3 Speed |
3 Speed |
3 Speed |
|
|
|
|
|
|
|
Controls |
|
|
|
|
|
Thermostat temp. range |
64° - 86° |
64° - 86° |
64° - 86° |
64° - 86° |
|
Outercase : insulation panels |
PBWS01A |
PBWS01A |
PBWS01A |
PBWS01A |
|
Condensate Drain Spout |
Yes on Outercase |
Yes on Outercase |
Yes on Outercase |
Yes on Outercase |
|
Thermostatic Drain Valve |
Yes |
Yes |
Yes |
Yes |
|
Adjustable changeover thermostat |
--- |
--- |
--- |
--- |
|
|
|
|
|
|
|
Chassis Size |
26" TTW |
26" TTW |
26" TTW |
26" TTW |
|
Chassis Heighth |
15.625" |
15.625" |
15.625" |
15.625" |
|
Chassis Width |
26" |
26" |
26" |
26" |
|
Chassis Depth |
16.875" |
16.875" |
16.875" |
16.875" |
|
|
|
|
|
|
5
SPECIFICATIONS |
|
|
PBE***E00AX |
|
|
|
|
MODEL |
PBE093E35AX |
PBE123E35AX |
|
|
|
|
|
Cooling (BTU's) |
9200 |
11800 |
|
8900 |
11400 |
|
|
|
|
||
@ EER |
9.8 |
9.8 |
|
Cooling Watts |
940 - 910 |
1200 - 1160 |
|
Cooling Amps |
4.4 - 4.7 |
5.6 - 6.0 |
|
|
|
|
|
Electric Heat |
11000 - 9000 |
11000 - 9000 |
|
Electric Heat Watts |
3500 - 2900 |
3500 - 2900 |
|
Electric Heat Amps |
15 / 14 |
15 / 14 |
|
|
|
|
|
Heatpump |
--- |
--- |
|
Heatpump Watts |
--- |
--- |
|
Heatpump Amps |
--- |
--- |
|
|
|
|
|
Fan Watts Indoor |
64 Indoor |
64 Indoor |
|
Fan Watts Outdoor |
123 Outdoor |
123 Outdoor |
|
|
|
|
|
Voltage |
230 -208 |
230 -208 |
|
|
|
|
|
Plug Type |
Perpendicular |
Perpendicular |
|
Power Cord Rating |
20 amp |
20 amp |
|
Power Cord Type |
LCDI |
LCDI |
|
Power Cord length |
6 feet |
6 feet |
|
|
|
|
|
Dehumidification: pints / hr. |
41 oz./hr |
55 oz./hr |
|
Fan Speeds |
|
|
|
CFM cooling : High-Low |
265/- |
265/- |
|
Fan Only Speed |
3 Speed |
3 Speed |
|
|
|
|
|
Controls |
|
|
|
Thermostat temp. range |
64° - 86° |
64° - 86° |
|
Outercase : insulation panels |
PBWS01A |
PBWS01A |
|
Condensate Drain Spout |
Yes on Outercase |
Yes on Outercase |
|
Thermostatic Drain Valve |
Yes |
Yes |
|
Adjustable changeover thermostat |
--- |
--- |
|
|
|
|
|
Chassis Size |
26" |
26" |
|
Chassis Heighth |
15.625" |
15.625" |
|
Chassis Width |
26" |
26" |
|
Chassis Depth |
16.875" |
16.875" |
|
|
|
|
|
6