AMF (Allied Telesis Management Framework)

Software Reference Supplement for x-Series Switches

AlliedWare PlusOperating System

Version 5.4.3

SwitchBlade® x8112

SwitchBlade® x908

x900-24XS and x900-24XT

x900-12XT/S

x610-24Ts and x610-24Ts/X

AT-x510-28GTX and AT-x510-52GTX

x610-48Ts and x610-48Ts/X

AT-x510-28GPX and AT-x510-52GPX

x610-24Ts-PoE+ and x610-24Ts/X-PoE+

AT-x510-28GSX

x610-48Ts-PoE+ and x610-48Ts/X-PoE+

 

x610-24SPs/X

 

C613-50031-01-REV B

 

Acknowledgments

This product includes software developed by the University of California, Berkeley and its contributors.

Copyright ©1982, 1986, 1990, 1991, 1993 The Regents of the University of California. All rights reserved.

This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/).

Copyright ©1998-2008 The OpenSSL Project. All rights reserved.

This product includes software licensed under the GNU General Public License available from:

http://www.gnu.org/licenses/gpl2.html

Source code for all GPL licensed software in this product can be obtained from the

Allied Telesis GPL Code Download Center at:

http://www.alliedtelesis.com/support/default.aspx

Allied Telesis is committed to meeting the requirements of the open source licenses including the GNU General Public License (GPL) and will make all required source code available.

If you would like a copy of the GPL source code contained in Allied Telesis products, please send us a request by registered mail including a check for US$15 to cover production and shipping costs and a CD with the GPL code will be mailed to you.

GPL Code Request

Allied Telesis Labs (Ltd)

PO Box 8011

Christchurch.

New Zealand

©2013 Allied Telesis Inc. All rights reserved.

This documentation is subject to change without notice. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or any means electronic or mechanical, including photocopying and recording for any purpose other than the purchaser’s internal use without the written permission of Allied Telesis, Inc.

Allied Telesis, AlliedWare Plus, AMF, Allied Telesis Management Framework, EPSRing, SwitchBlade, and VCStack are trademarks or registered trademarks in the United States and elsewhere of Allied Telesis, Inc. Adobe, Acrobat, and Reader are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States and/or other countries. Additional brands, names and products mentioned herein may be trademarks of their respective companies.

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

2

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

C613-50031-01 REV B

Contents of this Software Reference

Supplement

This document introduces AMF for Allied Telesis x-series switches. It contains the following introductory material on AMF, including links to related information.

Introduction to AMF on page 5

How To Configure and Use AMF on Allied Telesis Switches on page 9

AMF Commands on page 49

Getting the most from this manual

Although you can view this document using Acrobat version 5, to get the best from this document, we recommend using Adobe Acrobat Reader version 8 or later. You can download Acrobat Reader free from http://www.adobe.com/.

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

C613-50031-01 REV B

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

3

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

4

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

C613-50031-01 REV B

Introduction to AMF

AMF, the Allied Telesis Management Framework, is a suite of network management features that simplify management of its member switchesfrom the network core out to its edge.

AMF simplifies switch recovery and firmware replacements and upgrades. It greatly reduces the network management and maintenance overhead.

AMF Capable Products and Software

AMF is supported on the following products when running software version 5.3.4-1.4 or later:

Switchblade™ x8100 series switches.

Switchblade™ x908 series switches.

x900 series switches.

x610 series switches.

x510 series switches.

For additional information on AMF, its configuration and its operation on Allied Telesis switches, watch the following videos from our YouTube channel.

AMF overview videos

Video

Topic

Introducing Software Defined Networking (SDN)

This video describes SDN, its key drivers, where it fits in the networking world, and what Allied Telesis has done to meet these emerging requirements.

Click the following link to view the video:

www.alliedtelesis.com/videos/whatissdn

Introducing AMF

This video describes AMF and how this powerful suite of management tools can automate your everyday network administration tasks.

Click the following link to view the video:

www.alliedtelesis.com/videos/introducingamf

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

C613-50031-01 REV B

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

5

Allied Telesis X610-24TS-POE+, X610-24SPS-X, X610-48TS, X610-24TS-X, X610-24TS-X-POE+ User Manual

Video

Topic

Centralized Network Management

This video shows how the management of modern complex networks can be greatly simplified with AMF.

Click the following link to view the video:

www.alliedtelesis.com/videos/AMFmanagement

Auto-provisioning

This video shows how the addition of new switches to expand the network can be automated with AMF.

Click the following link to view the video:

www.alliedtelesis.com/videos/AMFautoprovisioning

Auto-Upgrade

This video shows how upgrading a large complex network can be automated with AMF.

Click the following link to view the video:

www.alliedtelesis.com/videos/AMFautoupgrade

Auto-Backup

This video shows how network back-ups can be automated with AMF.

Click the following link to view the video:

www.alliedtelesis.com/videos/AMFautobackup

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

6

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

C613-50031-01 REV B

Video

Topic

AMF Live Demo: Zero-Touch Auto Recovery

This video shows a live demonstration of the autorecovery feature of AMF. A network device is powered off to simulate a failure and the replacement is automatically re-configured by AMF without any user intervention.

Click the following link to view the video:

www.alliedtelesis.com/videos/AMFautorecovery

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

C613-50031-01 REV B

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

7

 

AMF Software Reference Supplement for Allied Telesis x-Series Switches

 

8

AlliedWare PlusTM Operating System - Software Version 5.4.3-1.4 and later

C613-50031-01 REV B

Technical Guide

How To | Configure and Use AMF on Allied Telesis Switches

Introduction

The Allied Telesis Management Framework (AMF) is a suite of features that combine to simplify network management across all supported network devices from the core to the edge.

AMF also provides simplified unit recovery and firmware upgrade management. The primary function of AMF is to reduce the management and maintenance overhead on a network, while improving on responsiveness and handling of device failures within the network.

What information will you find in this document?

This How To Note describes AMF along with its benefits, concepts, and configuration guidelines. For more information on the commands used in this How To note, see the AMF Commands chapter later included within this document. Also for those who would like to know more about AMF, see the Introduction to AMF.

Which products and software version does it apply to?

This How To Note applies to the following Allied Telesis switches running AlliedWare Plus OS software version 5.4.3 or later:

SwitchBlade™ x8100 family

SwitchBlade™ x908 series switches

x900 series switches

x610 series switches

x510 series switches

C613-16174-00 REV D

 

 

 

 

 

alliedtelesis.com x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Introduction

Contents

 

Introduction.............................................................................................................................................................................

9

What information will you find in this document?...................................................................................

9

Which products and software version does it apply to? .....................................................................

9

Software feature licensing ...................................................................................................................................

11

The key benefits of AMF ..............................................................................................................................................

12

Unified command-line .........................................................................................................................................

12

Configuration backup and recovery ............................................................................................................

12

Rolling firmware upgrade ....................................................................................................................................

12

AMF concepts.....................................................................................................................................................................

13

Network name..........................................................................................................................................................

13

Node...............................................................................................................................................................................

13

Master nodes..............................................................................................................................................................

13

Domains........................................................................................................................................................................

13

Core distance.............................................................................................................................................................

14

Links.................................................................................................................................................................................

15

Crosslinks......................................................................................................................................................................

15

Working-sets ..............................................................................................................................................................

16

AMF network guidelines ...............................................................................................................................................

16

Retention and use of the ‘manager’ username.......................................................................................

16

Loop-free data plane .............................................................................................................................................

17

Aggregators.................................................................................................................................................................

17

VCStacks.......................................................................................................................................................................

17

AMF external removable media......................................................................................................................

17

AMF interaction with QoS and ACLs..........................................................................................................

18

NTP and AMF ...........................................................................................................................................................

18

Configuring AMF ...............................................................................................................................................................

19

Simple AMF example with a single master ...............................................................................................

19

Verifying the AMF network................................................................................................................................

24

Using the AMF network................................................................................................................................................

25

AMF backups..............................................................................................................................................................

25

Safe removal of external storage media.....................................................................................................

26

Performing a manual backup ......................................................................................................................................

27

Backups on VCStacks running as AMF masters ..............................................................................................

28

Node recovery...................................................................................................................................................................

30

Automatic node recovery ..................................................................................................................................

30

A “Clean” node ........................................................................................................................................................

31

Manual node recovery..........................................................................................................................................

31

Node recovery on VCStacks............................................................................................................................

32

AMF safe configuration..................................................................................................................................................

34

How can I undo a safe configuration?..........................................................................................................

35

Page 10 | How to Configure and Use AMF on Allied Telesis Switches

 

I n trod u ction

Adding a preconfigured device to the network

..............................................................................................36

Using the unified CLI with working-sets...............................................................................................................

38

The working-set........................................................................................................................................................

38

Working-set groups ................................................................................................................................................

38

Automatic working-set groups.........................................................................................................................

39

User-defined working-set groups....................................................................................................................

40

Executing commands on working-sets ........................................................................................................

41

Interactive commands ...........................................................................................................................................

43

Rolling-reboot firmware upgrade.............................................................................................................................

44

Performing a rolling reboot upgrade.............................................................................................................

45

Software feature licensing

A feature licence is required for each AMF master node in the AMF network. AMF master node licences are available for the SBx8100 and SBx908 platforms. A licence is not required for AMF member nodes.

How to Configure and Use AMF on Allied Telesis Switches | Page 11

The key benefits of AMF

The key benefits of AMF

The key benefits of AMF include its: unified command-line, simple configuration backup and recovery process, and time-saving rolling firmware upgrade.

Unified command-line

The primary means of configuring and controlling AlliedWare Plus (AW+) units is via a textbased command-line interface. In existing networks, this command-line is available via a serial console port as well as remote login sessions (e.g. SSH).

Under AMF, this concept is extended to allow control of an entire network of AW+ devices (or any part thereof) via a single session. It allows a network administrator to nominate all nodes or a subset of nodes within the AMF network, known as a working-set. Commands can then execute concurrently across all nodes in the nominated working-set as if it were a single unit. Any existing configuration or diagnostic actions can thus be applied to multiple devices, reducing repetitive and error-prone roll-out procedures. In this way, regularities in network design can be used to reduce maintenance cost and complexity, while still retaining complete flexibility in network design and control. Currently AMF supports a network of up to 42 nodes, and multiple AMF networks can exist side by side across a single physical network. A Virtual Chassis Stack (VCStack) is considered to be just one node by AMF.

Configuration backup and recovery

An AMF network has a master node that uses external storage to automatically backup complete configuration information of all the other nodes, including boot configuration, firmware, licenses, and user scripts. If a node subsequently fails, the AMF will automatically recognize and reconfigure an unconfigured replacement unit, completely recreating the stored state of the failed unit into the replacement unit. This new unit will then reboot and resume service, without any need for user intervention beyond physical hardware replacement. In this way AMF provides a complete zero-touch recovery solution.

If preferred (or if automatic recovery fails), the new hardware will be held in a safe nonforwarding state—ready for a network administrator to configure remotely via the AMF unified command-line.

Rolling firmware upgrade

Firmware upgrades on a production network are typically an infrequent but sensitive and labour-intensive process. AMF supports automated firmware roll-out to a user-selected subset of nodes. The user selects a target group of nodes, and the location where the new firmware is stored, then AMF takes care of the rest. Nodes are upgraded in a serial fashion, with each node tested before continuing with subsequent nodes.

If an upgrade fails, the upgrade process is automatically terminated and that node is reverted to the previous firmware version. In this way firmware updates are almost completely handsfree, while providing confidence that a bad update will not result in loss of service.

Page 12 | How to Configure and Use AMF on Allied Telesis Switches

AMF concepts

AMF concepts

Network name

The AMF network name is used to determine the AMF network a node belongs to. All nodes within an AMF network must be configured with the same AMF name.

Node

AMF members are commonly referred to as nodes. A node can be a single switch, or a VCStack.

Master nodes

AMF master nodes are user defined and form the core domain of the AMF network. They are:

responsible for performing file system backups of all nodes in the AMF network.

required before an AMF network can form; at least one must be present.

AMF master nodes are supported on SBx908 and SBx8100 platforms; an AMF licence is required for each master. Only one AMF master license is required even if two CFCs are installed. The license is for the chassis, not the CFC.

Notes: A VCStack needs to have consistent licensing on all stack members, so an AMF master license would be required on both devices in an SBx908 stack.

When more than one AMF master node exists in an AMF network, it is important to know that these operate completely independently of each other, and there is no synchronization between AMF master nodes.

For redundancy, you can have multiple master nodes, each acting as a master for the network. But, there is no synchronization of status or data files between the masters. The behaviour of a master node is not changed at all by the presence of other master nodes.

Domains

Every AMF node belongs to an AMF domain, which may be comprised of multiple nodes or only a single node. AMF master nodes are included in the core domain, and all other domains are rooted in the core domain. AMF domains are determined by AMF crosslinks, (see page 15). All nodes connected via AMF crosslinks are part of the same domain, and

How to Configure and Use AMF on Allied Telesis Switches | Page 13

AMF concepts

nodes connected via regular AMF links will be part of a higher or lower domain depending on whether they are closer to or further away from the core domain. Nodes within a domain must be connected in either a chain or ring topology.

This means that a maximum of two crosslinks should be configured on any single node. The advantage of an AMF domain is that two links from a domain to a single higher level domain (closer to the core) will provide redundant AMF links. It is recommended that an AMF domain should only be connected to a single higher level domain, though it may be connected to multiple lower level domains.

It is recommended that:

The maximum number of nodes per domain is 12 for SBx8100, x908, x900, x610, and x510.

Core distance

This is the distance (hop count) between a domain and the Core domain. The Core domain has a Core distance of 0, and the maximum recommended Core distance in an AMF network is 8.

 

 

 

 

 

 

 

 

 

 

Master

AMF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Node ID1

 

node

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMF

 

 

 

 

 

 

 

 

 

AMF

 

 

 

 

 

Node ID3

Member

 

 

 

 

 

 

 

 

Master

 

 

 

 

 

node

 

 

 

 

 

 

 

node

 

 

 

AMF

 

 

 

 

 

 

 

 

 

 

Node ID2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Member

node

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Node ID5

 

 

 

 

 

 

 

 

 

 

AMF

 

 

 

 

 

 

 

 

AMF

 

 

 

 

 

 

 

 

 

CORE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Node ID4

Member

 

 

 

 

 

 

 

 

 

Member

node

 

 

 

node

 

 

 

DISTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Node ID6

 

 

AMF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

Member

node

 

 

 

 

 

 

CORE

 

 

 

 

 

 

 

 

 

Node ID7

 

AMF

 

 

DISTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amf-crosslink

 

 

 

 

 

 

Member

node

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

amf-link

 

 

 

 

 

 

 

Node ID8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CORE

 

 

 

 

 

 

Domain Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Backup Domain Controller

 

 

 

 

 

 

 

 

DISTANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1: AMF domains and Core distance

 

 

 

 

 

 

 

 

 

 

 

 

Page 14 | How to Configure and Use AMF on Allied Telesis Switches

AMF concepts

Links

AMF links are used to connect AMF nodes to AMF nodes in other AMF domains, and are either uplinks or downlinks. Uplinks are used to connect a domain with a higher Core distance (further from the Core) to a domain with a lower Core distance (closer to the Core. Downlinks are used to connect a domain with a lower Core distance to a domain with a higher Core distance.

AMF links are used to pass AMF management traffic between nodes, but can also be used to carry other network traffic. Configuring an interface as an atmf-link will automatically put the port into trunk mode. An AMF link must have at least one tagged VLAN, or have a native VLAN defined. An AMF link can be either a single link or a static aggregator.

Crosslinks

AMF crosslinks are used to connect AMF nodes to other AMF nodes within the same AMF domain. AMF master nodes must be connected using AMF crosslinks to ensure they are part of the core domain. Configuring an interface as an atmf-crosslink will automatically put the port into trunk mode. A crosslink can be either a single link or a static aggregator.

Core Domain

Uplink

AMF

Member

node

 

Crosslink

Downlink

Figure 2: AMF uplinks, downlinks, and crosslinks

How to Configure and Use AMF on Allied Telesis Switches | Page 15

AMF network guidelines

Working-sets

An AMF working-set is a set of nodes, which is either arbitrarily user defined, or one of the pre-defined working-set groups (see "Working-set groups" on page 38). Specifying or selecting a working-set allows CLI commands to be executed on all nodes within the selected working-set with a single command. A working-set can be defined, selected and configured from any node within an AMF network.

 

 

 

 

AMF Network

 

 

 

 

 

 

 

Master

1

 

 

 

 

 

 

 

 

 

 

 

 

Member

1

 

 

 

 

 

 

 

 

 

 

 

 

Member

3

 

 

 

 

 

 

 

 

 

 

 

AMF

 

 

 

 

Member

 

 

 

 

Member

 

 

 

 

working-set

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

2

 

 

 

Member

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Member

6

 

 

 

 

 

 

 

 

Master

2

 

Figure 3: AMF working-set containing nodes Master1, Member1, Member2, and Member6

AMF network guidelines

Retention and use of the ‘manager’ username

The default username for an Alliedware Plus login is manager, with a documented default password. Users should change this password on all their nodes to provide login security. In order to centrally manage nodes undergoing automated node recovery, or to expand the network by adding a new unconfigured node, it will be necessary to login with the default manager username.

It is possible to add new usernames and passwords to nodes, but to retain the ability to centrally manage the network, usernames should be uniformly configured across all AMF nodes within the AMF network.

Page 16 | How to Configure and Use AMF on Allied Telesis Switches

AMF network guidelines

Loop-free data plane

The current version of AMF does not control the data plane, so it is a requirement that the network is configured such that the data plane is kept loop free.

Note: Currently AMF does not support the use of STP on links between AMF nodes. Use of STP with redundant network links has the potential to block AMF control connections, and also could lead to periods of traffic leakage during the start of automatic node recovery. Hence, if there are physical loops in any of the data VLANs in the network, then EPSR must be used as the protection mechanism for those loops.

Aggregators

Dynamic Aggregators (LACP) cannot be used on ports configured as AMF links or crosslinks. Therefore any aggregated links in an AMF network need to be configured as static aggregators.

VCStacks

If any VCStacks are included as AMF nodes it is a requirement that the VCS virtual MAC feature is enabled to ensure correct operation of the AMF network. If the VCStack is running as an AMF master node it is also a requirement that removable external storage media is installed in both stack members.

AMF external removable media

All AMF master nodes require external storage media (e.g. USB memory stick, SD card) to be installed. This external storage is used to hold a backup of all relevant files from all nodes within the AMF network, including other master nodes, so it must be large enough to be able to accommodate all of the backed up files. Files that are backed up include all configuration files, release files, and scripts, but not core dumps, exception logs, or technical support files.

Typically a 4GB capacity external media device would be of sufficient size to hold backups for a 40 node AMF network.

When using Dual CFCs in a SBx8100, a memory stick is required in both CFCs.

How to Configure and Use AMF on Allied Telesis Switches | Page 17

AMF network guidelines

AMF interaction with QoS and ACLs

It's important that ACL and QoS rules do not block any traffic on VLAN 4091 and 4092 as they are the default AMF control VLANs. Likewise ACL and QoS rules should not block any Layer 3 traffic on 172.31.0.* or 172.31.128.* as these are the default AMF management traffic subnets. Packets with protocol type 0xfbae and BPDU packets that use the MAC address:

0180.c200.002e should also not be blocked.

Note: The AMF control VLANs and AMF management subnets can be manually changed.

With AMF enabled, the number of ACLs on the x510 switch decreases from 249 to 248. If this is an issue, then you can disable AMF, which will allow the previous maximum of 249.

Enabling AMF on the x610 switch provides 2048 ACLs.

NTP and AMF

AMF uses NTP to synchronize the system clocks across nodes within the network. For this to operate there must either be one or more external NTP servers configured on the network, or one single AMF node must be configured as the NTP 'master' using the command ntp master 11.

Note: It is not valid to have an NTP master configured on an AMF node anywhere in the network if any external NTP servers exist, as this will prevent clock synchronization.

If there is no external server, and instead the network has a node configured with the command: ntp master 11, the following commands will work as expected:

awplus (config)#atmf working set group all awplus (config)#clock set 16:51:00 24 Aug 2012

The clock set command may also be used prior to configuring an external NTP server to get the network roughly up to the correct time, so that NTP will synchronize faster.

The primary function of NTP within an AMF network is to ensure that time and date stamps on backups are consistent across member nodes within the backup. This is particularly important in an AMF network that has multiple AMF master nodes, to ensure that node recovery is performed with the most up to date backup.

Page 18 | How to Configure and Use AMF on Allied Telesis Switches

Configuring AMF

Configuring AMF

The following configuration example uses a simplified network to explain the steps required to configure AMF.

Simple AMF example with a single master

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMF

 

 

 

 

 

 

 

 

 

 

 

 

 

Master

1

 

 

 

 

 

 

 

 

 

 

port1.

 

 

 

 

 

 

 

 

 

 

port1.

 

 

 

 

 

 

 

 

 

 

 

 

 

Member

1.

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

1

 

 

 

 

 

 

 

port1.

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

port1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

port1.

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

port1.

 

 

1.

 

 

 

 

port1.

 

 

 

 

 

 

 

 

2

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

Member

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

port1.

 

 

Member

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

port1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

port1.

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.

 

 

 

 

 

 

 

 

 

 

 

 

 

Member

1

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

Crosslink

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link

Figure 4: Simple AMF network

Configuration AMF Master

1. Set the host name.

awplus#conf t

awplus(config)#hostname AMF_Master

Host names are used as the AMF node name and must be unique within the AMF network.

2. Set the AMF network name.

AMF_Master (config)#atmf network-name atmf1

Note: The AMF network name must be the same on all nodes within the AMF network, and the device must be rebooted before the AMF network name takes effect.

3.Configure the device as the AMF master.

AMF_Master (config)#atmf master

An AMF network must have at least one master configured. A licence is required for each AMF master in the AMF network. If an AT-x8100 with dual CFCs is configured as an AMF master a licence is only required on the CFC master, as the licence with be synchronized

How to Configure and Use AMF on Allied Telesis Switches | Page 19

Configuring AMF

across CFCs. If an AT-x908 VCStack is configured as an AMF master, a licence is required to be installed on both stack members.

4. Configure the data VLANs.

AMF_Master(config)#vlan database

AMF_Master(config-vlan)#vlan 2-3

5. Disable RSTP globally (this is enabled by default).

AMF_Master (config)#no spanning-tree rstp enable

6. Configure ports as AMF-links.

AMF_Master(config)#int port1.1.1-1.1.2

AMF_Master(config-if)#switchport atmf-link

7. Configure data VLANs on AMF-links as required.

AMF_Master (config-if)#switchport trunk allowed vlan add 2-3

8. Save the configuration and reboot the switch.

AMF_Master #copy running-config startup-config

Building configuration...[OK]

AMF_Master#reload

Are you sure you want to reboot the whole chassis? (y/n): y

Configuration Member 1

1. Set the host name.

awplus#conf t awplus(config)#hostname Member1

Host names must be unique within the AMF network.

2. Set the AMF network name.

Member1(config)#atmf network-name atmf1

Note: The AMF network name must be the same on all nodes within the AMF network, and the device must be rebooted before the AMF network name takes effect.

3. Configure data VLANs.

Member1(config)#vlan database

Member1(config-vlan)#vlan 2-3

4.Disable RSTP globally (this is enabled by default).

Member1(config)#no spanning-tree rstp enable

Page 20 | How to Configure and Use AMF on Allied Telesis Switches

Configuring AMF

5. Configure ports as AMF-links.

Member1(config)#int port1.1.1,port1.1.3

Member1(config-if)#switchport atmf-link

6. Configure data VLANs on the AMF links as required.

Member1(config-if)#switchport trunk allowed vlan add 2-3

7. Configure AMF-crosslink.

Member1(config)#int port1.1.2

Member1(config-if)#switchport atmf-crosslink

Member1(config-if)#switchport trunk native vlan none

Note: AMF links and crosslinks are not required to be configured with data VLANs and can be used solely to provide AMF management VLAN redundancy.

8. Save the configuration and reboot the switch.

Member1#copy running-config startup-config Building configuration...

[OK]

Member1#reload

reboot system? (y/n): y

Configuration Member 2

1. Set the host name.

awplus#conf t awplus(config)#hostname Member2

Note: Hostnames are used as the AMF node name and must be unique within the AMF network..

2. Set the AMF network name.

Member2(config)#atmf network-name atmf1

Note: The AMF network name must be the same on all nodes within the AMF network, and the device must be rebooted before the AMF network name takes effect.

3. Configure a data VLAN.

Member2(config)#vlan database

Member2(config-vlan)#vlan 2-3

4.Disable RSTP globally (this is enabled by default).

Member2(config)# no spanning-tree rstp enable

How to Configure and Use AMF on Allied Telesis Switches | Page 21

Configuring AMF

5. Configure ports as AMF-links.

Member2(config)#int port1.1.1,port1.1.3

Member2(config-if)#switchport atmf-link

6. Configure data VLANs on the AMF-links as required.

Member2(config-if)#switchport trunk allowed vlan add 2-3

7. Configure AMF-crosslink.

Member2(config)#int port1.1.2

Member2(config-if)#switchport atmf-crosslink

Member2(config-if)#switchport trunk native vlan none

Note: AMF links and crosslinks are not required to be configured with data VLANs and can be used solely to provide AMF management VLAN redundancy.

8. Save the configuration and reboot the switch.

Member2#copy running-config startup-config Building configuration...

[OK]

Member2#reload

reboot system? (y/n): y

Configuration Member 3

1. Set the host name.

awplus#conf t awplus(config)#hostname Member3

Host names must be unique within the AMF network.

2. Set the AMF network name.

Member3(config)#atmf network-name atmf1

Note: The AMF network name must be the same on all nodes within the AMF network, and the device must be rebooted before the AMF network name takes effect.

3. Configure data VLANs on the AMF-link.

Member3(config)#vlan database

Member3(config-vlan)#vlan add 2-3

4.Disable RSTP globally (this is enabled by default).

Member3(config)#no spanning-tree rstp enable

Page 22 | How to Configure and Use AMF on Allied Telesis Switches

Configuring AMF

5. Configure ports as AMF-links.

Member3(config)#int port1.0.1

Member3(config-if)#switchport atmf-link

6. Configure data VLANs on the AMF links as required.

Member3(config-if)#switchport trunk allowed vlan add 2-3

7. Save the configuration and reboot the switch.

Member3#copy running-config startup-config Building configuration...

[OK]

Member3#reload

reboot system? (y/n): y

Configuration Member 4

1. Set the host name.

awplus#conf t awplus(config)#hostname Member4

Host names must be unique within the AMF network.

2. Set the AMF network name.

Member4(config)#atmf network-name atmf1

Note: The AMF network name must be the same on all nodes within the AMF network, and the device must be rebooted before the AMF network name takes effect.

3. Configure data VLANs

Member4(config)#vlan database

Member4(config-vlan)#vlan 2-3

4.Disable RSTP globally (this is enabled by default).

Member4(config)#no spanning-tree rstp enable

5.Configure ports as AMF-links.

Member4(config)#int port1.0.1

Member4(config-if)#switchport atmf-link

6. Configure data VLANs on the AMF links as required.

Member4(config-if)#switchport trunk allowed vlan add 2-3

How to Configure and Use AMF on Allied Telesis Switches | Page 23

Configuring AMF

7. Save the configuration and reboot the switch.

Member4#copy running-config startup-config Building configuration...

[OK]

Member4#reload

reboot system? (y/n): y

Verifying the AMF network

To check that all nodes have joined the AMF network use the show atmf summary command, which can be executed from any node in the AMF network:

AMF_Master#show atmf summary

ATMF Summary Information:

ATMF Status

: Enabled

Network Name

: atmf1

Node Name

: AMF_Master

Role

: Master

Current ATMF Nodes

: 5

AMF_Master#

 

The Current ATMF Nodes field in the output above shows that all 5 nodes have joined the AMF network.

Use the show atmf nodes command to check information on individual nodes:

AMF_Master#show atmf nodes

 

 

 

 

 

Node Information:

 

 

 

 

 

* = Local device

 

 

 

 

 

SC = Switch Configuration:

 

 

 

 

 

C = Chassis

S = Stackable

N = Standalone

 

 

 

Node

Device

ATMF

 

 

 

Node

Name

Type

Master

SC

 

Parent

Depth

---------------------------------------------------------------------

* AMF_Master

AT-SBx81CFC400

Y

C

none

0

Member1

SwitchBlade x908

N

S

AMF_Master

1

Member2

SwitchBlade x908

N

S

AMF_Master

1

Member4

x510-52GTX

 

N

S

Member2

2

Member3

x510-52GTX

 

N

S

Member2

2

Current ATMF node count 5

 

 

 

 

 

Note: The Parent field refers to the parent domain and not the upstream device. In the example output above, Member2 is the domain controller for the parent domain for Member3 and Member4.

Page 24 | How to Configure and Use AMF on Allied Telesis Switches

Using the AMF network

Using the AMF network

AMF backups

AMF backups are an essential part of AMF network operation, as they are the mechanism by which AMF master nodes update their records of the AMF network. By default, AMF master nodes are configured to perform automatic scheduled backups of the entire AMF network once per day at 3.00am. AMF backups are stored on external removable media (e.g. USB Flash stick, SD card), thus it is a requirement that all AMF masters have external removable media installed that is of sufficient capacity to hold all of the relevant files stored in the Flash by every node in the AMF network.

Typically a 4GB capacity external media device would be of sufficient size to hold backups for a 40 node AMF network.

The AMF node backup system has been designed such that the external media used to store the backup data can still be used to store other data, however care needs to be taken to ensure that enough space is reserved for future AMF backups.

AMF requires up to 128MB backup space for SBx8100 nodes and up to 64MB backup space for other nodes. The show atmf backup command output will provide warnings if capacity on the backup media falls below a safe level.

Here is some example output of the show atmf backup command showing a backup media space warning:

master1#show atmf backup

Scheduled Backup ......

Disabled

Schedule ............

1 per day starting at 12:45

Next Backup Time .... 25 May 2012 12:45

Backup Media ..........

SD (Total 3827.0MB, Free 7.1MB)

 

WARNING: Space on backup media is below 64MB

Current Action ........

Idle

Started .............

-

Current Node ........

-

How to Configure and Use AMF on Allied Telesis Switches | Page 25

Using the AMF network

Safe removal of external storage media

Removing external storage media, or rebooting the master node, while an AMF backup is underway could potentially cause corruption to files in the backup. Although files damaged as a result of mishandling backup media will be replaced during the next backup cycle, if the file system on the media becomes damaged it may require reformatting before being inserted into the AMF master. To avoid any damage to the AMF backup files or file system it is recommended that the following procedure is followed before rebooting or removing any external storage media from an AMF master.

1.Disable backups to prevent a scheduled backup from occurring while the card is being removed.

2.Terminate any backup already in process.

3.Verify that it is safe to remove the media by checking for a Disabled scheduler and Idle backup.

Here is an example output showing the safe external storage media removal procedure:

master1#conf t

 

master1(config)#no atmf

backup enable

master1(config)#exit

 

master1#atmf backup stop

 

master1#show atmf backup

 

Scheduled Backup ......

Disabled

Schedule ............

1 per day starting at 12:45

Next Backup Time ....

25 May 2012 12:45

Backup Media ..........

SD (Total 3827.0MB, Free 3257.1MB)

Current Action ........

Idle

Started .............

-

Current Node ........

-

...

 

 

 

Once the media has been reinstalled, ensure that the backup scheduler is re-enabled: master1#conf t

master1(config)#atmf backup enable master1(config)#exit

Page 26 | How to Configure and Use AMF on Allied Telesis Switches

Performing a manual backup

Performing a manual backup

Whenever a new device is added to the AMF network or when the configuration has changed on a member node, it is always advisable to perform a manual backup from the AMF master in order to ensure the removable media installed on the master node has an up to date backup of all nodes within the AMF.

To perform a manual backup of the entire AMF network, on the AMF master enter the command atmf backup now:

AMF_Master#atmf backup now

Backup successfully initiated

AMF_Master#

To check the status of the AMF backup use the command show atmf backup.

Example output of the show atmf backup command during backup:

AMF_Master#show atmf backup

 

 

Scheduled Backup ......

Enabled

 

 

Schedule ............

1 per day starting at 03:00

 

Next Backup Time ....

14 Dec 2012 03:00

 

 

Backup Media ..........

USB (Total 3692.6MB, Free 1782.7MB)

Current Action ........

Doing manual backup

 

 

Started .............

13 Dec 2012 05:20

 

 

Current Node ........

Member1

 

 

Node Name

Date

Time

In ATMF On Media Status

------------------------------------------------------------------------------

AMF_Master

13 Dec 2012

05:20:16

Yes

Yes

Good

Member1

-

-

Yes

Yes

-

Member2

-

-

Yes

No

-

Member3

-

-

Yes

No

-

Member4

-

-

Yes

No

-

Example output of the show atmf backup command after backup has completed:

AMF_Master#show atmf backup

Scheduled Backup ......

Enabled

Schedule ............

1 per day starting at 03:00

Next Backup Time ....

13 Dec 2012 03:00

Backup Media ..........

USB (Total 3692.6MB, Free 1651.1MB)

Current Action ........

Idle

Started .............

-

Current Node ........

-

Node Name Date Time In ATMF On Media Status

------------------------------------------------------------------------------

ATMF_Master

13

Dec 2012

05:20:16

Yes

Yes

Good

Member1

13

Dec 2012

05:20:27

Yes

Yes

Good

Member2

13

Dec 2012

05:20:40

Yes

Yes

Good

Member3

13

Dec

2012

05:20:52

Yes

Yes

Good

Member4

13

Dec

2012

05:21:08

Yes

Yes

Good

Note: The file system used by the AMF backup does not support the backing up of files that have the same name but have different case (e.g. “test.txt” and “TEST.txt”), and only one of these files will be stored in the backup. For this reason it is recommended that all files on a node have unique file names.

How to Configure and Use AMF on Allied Telesis Switches | Page 27

Backups on VCStacks running as AMF masters

Backups on VCStacks running as AMF masters

When a VCStack or SBx8100 with dual CFCs is running as an AMF master node, it is important to note that an AMF backup will only occur on the external removable media installed in the VCS master (or Active CFC). This means that following a failover event, the new VCS master will not have an AMF backup stored on its external storage media, and will not be able to provide configuration backup and recovery when required.

To avoid this situation, the recommended solution is to use trigger scripts to automatically perform a manual backup of the AMF network following a failover event.

Example manual backup activation script called triggered-atmfbackup.scp:

enable wait 180

atmf backup now

Note: There is a syntax difference between the configuration commands required to create the necessary trigger on the SBx8100 and SBx908.

Example trigger script configuration for the SBx8100:

awplus#conf t awplus(config)#trigger 1

awplus(config-trigger)#type chassis active-CFC-fail awplus(config-trigger)#script 1 triggered-atmfbackup.scp

Example trigger script configuration for the SBx908:

awplus#conf t awplus(config)#trigger 1

awplus(config-trigger)#type stack master-fail awplus(config-trigger)#script 1 triggered-atmfbackup.scp

If there are multiple AMF master nodes in the network, you may also want to use a trigger script or perform a manual backup of all master nodes whenever there is a failover event to ensure that all backups are up to date. Create an atmf working-set group which contains all master nodes, and then use the atmf working-set command in the trigger script to execute the manual backup on all nodes within the working set group.

To create a working-set containing all AMF master nodes, first manually select all AMF masters using the atmf working-set command:

Master#atmf working-set Master1,Master2

===================

Master1, Master2:

===================

Working set join atmf1[2]#

Page 28 | How to Configure and Use AMF on Allied Telesis Switches

Backups on VCStacks running as AMF masters

Next, create a user defined working-set group containing the nodes in the current workingset using the atmf group command:

atmf1[2]#conf t

atmf1[2](config)#atmf group AMF_masters

Here is an example manual backup activation script called atmfbackup_all_masters.scp:

enable wait 180

atmf working-set group AMF_masters atmf backup now

How to Configure and Use AMF on Allied Telesis Switches | Page 29

Node recovery

Node recovery

Automatic node recovery

AMF has been designed so that when a node fails it can be replaced with an unconfigured device of the same type, and AMF will automatically upgrade and configure the new device from the most recent backup. Often the replacement device will be a factory default, brand new “out of the box” device, but it may be that you want to replace the failed unit with one that has been previously used elsewhere. In this instance it is necessary to return the replacement device to a “clean” state so that AMF can recognize it as a suitable replacement, and begin automatic recovery. (See section "A “Clean” node" on page 31)

When a failed node is replaced with an unconfigured device, AMF immediately disables forwarding on the device, shuts down all non-AMF ports, and applies the AMF safe configuration. (See section "AMF safe configuration" on page 34.) AMF then checks whether any of the AMF master nodes has a valid backup for the replacement node, and if it finds one it begins to attempt automatic node recovery. Once automatic node recovery has completed, it will then reboot the replacement node which will then rejoin the AMF network with identical files and configuration, to the failed node it replaced.

Here is some example console output showing automatic node recovery:

Warning: No changes should be made to the device's configuration while a node recovery is underway. A log message will appear on the console or other logged in session indicating when recovery has finished (whether successfully or with errors). This message can also be found by viewing the log with the show log command.

23:03:15 awplus

ATMF[863]: ATMF network detected

23:03:15 awplus

ATMF[863]: ATMF safe config applied (forwarding

disabled)

 

23:03:25 awplus

ATMF[863]: Shutting down all non ATMF ports

23:03:26 x510_1

ATMF[863]: Automatic node recovery started

23:03:26 x510_1

ATMF[863]: Attempting to recover as x510_1

23:03:26 x510_1

ATMF[863]: Checking master node availability

23:03:32 x510_1

ATMF[863]: Master has joined. 2 members in total.

23:03:32 x510_1

ATMF[863]: x908_VCS_2 has joined. 3 members in total.

23:03:32 x510_1

ATMF[863]: x908_VCS_1 has joined. 4 members in total.

23:03:37 x510_1

ATMFFSR[2950]: Retrieving recovery data from master

node Master

 

23:05:18 x510_1

ATMFFSR[2950]: File recovery from master node

succeeded. Node

will now reboot

Flushing file system buffers...

Unmounting any remaining filesystems...

Restarting system.

Page 30 | How to Configure and Use AMF on Allied Telesis Switches

Loading...