AEG-Electrolux 570D-M, 570D-M9 User Manual

0 (0)

DL 4150 - CHDL 4150 HL 4150 - DL 6250 570 D - 5708 D

Cooker Hood

Cappa aspirante

Campana extractora

Exaustor

Operating and Installation Instructions Istruzioni di montaggio ed uso Instrucciones de montaje y manejo Manual de Instruções

Contents

Safety warnings

3

For the user

3

For the installer

4

Description of the Appliance

6

Extraction mode

6

Recirculation mode

6

Control Panel

7

Maintenance and care

8

Cleaning the hood

8

Metal grease filter

8

Removing the metal grease filter

8

Charcoal filter

10

Changing the light bulb

11

What to do if

12

Special accessories

13

Technical assistance service

13

Technical Specifications

14

Electrical connection

15

Installation

16

Removing the hood from cabinet

18

Relocating the control unit (Only 570 D - 5708 D)

19

2

Safety warnings

For the user

The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.

Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.

Also, when frying, keep the deep frying pan on the cooker top/ cooker under careful control.

The hot oil in the frying pan might ignite due to overheating.

The risk of self-ignition increases when the oil being used is dirty.

It is extremely important to note that overheating can cause a fire.

Never carry out any flambé cooking under the hood.

Always disconnect the unit from the power supply before carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker).

It is very important to clean the hood and replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, resulting in a fire hazard.

This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE).

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.

The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. Disposal must be carried out in accordance with local environmental regulations for waste disposal.

For more detailed information about treatment, recovery and recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

3

For the installer

When used as an extractor unit, the hood must be fitted with a hose having preferably the same diameter as the outlet hole.

Only 5708 D: this model is equipped with two outlet hole. 2 hoses are therefore necessary for discharging the fumes.

When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces:

electric cookers

650 mm

models (CH)DL 4150-HL 4150-DL6250 only

600 mm

gas cookers

700 mm

The hood can be installed above these heights but for optimum performance it should be installed at the distance quoted for the appropriate heat source.

The national standard on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms.

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

The air outlet installation must comply with the regulations laid down by the relevant authorities.

When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney, such as coal or oil room-heaters and gas fires, in the same room.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the

4

aforementioned measures.

When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation:

short and straight outlet hose

keep bends in outlet hose to a minimum

never install the hoses with an acute angle, they must always follow a gentle curve.

keep the hose as large as possible (preferably the same diameter as the outlet hole).

Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood.

5

AEG-Electrolux 570D-M, 570D-M9 User Manual

Description of the Appliance

The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.

The hood is supplied as an extractor unit and can also be used with a recirculation mode by fitting a charcoal filter.

In some models the charcoal filter is supplied. The hood, therefore, can be used immediately in the recirculation mode. We advise removing the charcoal filter to use the hood in the extraction mode.

Extraction mode

In this mode fumes are extracted to the outside via a hose connected to the coupling ring. Fig. 1.

In order to obtain the best performance the hose should have a diameter equal to the outlet hole.

Only 5708 D: this model is equipped with two outlet hole. 2 hoses are therefore necessary for discharging the fumes.

Only for model DL 4150-CHDL 4150-HL 4150:

Should there already be an hose of diameter 100 mm that ducts to the outside through the walls or roof, it is possible to use the 120/ 100 mm adapter. In this case the hood will be slightly noisier.

Coupling ring

510

710

Bayonet screw fitting

(Only 570 D (1x) - 5708 D (2x))

Fig. 1

Filter Version

• The air is filtered through a charcoal filter and returned to the kitchen. Fig. 2.

• You will need an original charcoal filter for the filtering function. (See Special Accessories).

Fig. 2