AEG-Electrolux 115DD, 115DW User Manual

0 (0)

115 D

Extractor Hood

Installation and Operating Instructions

Contents

Introduction

3

Extractor version

3

Recirculating mode

4

Electrical connections

5

Safety warnings for electrician

5

Specifications

8

Installation

9

Safety warnings for kitchen unit installer

9

Wall unit mounting

10

Wall mounting

11

Hood operation

12

Safety warnings for user

12

Maintenance and care

13

Opening the grille

13

Grease filter

13

carbon filter

13

Changing the light bulb

14

Cleaning

15

Special Accessories

15

Technical Assistance Service

16

OKO

MADE

IN

 

SYSTEM GERMANY

Printed on recycled paper. AEG – putting words into action.

2

AEG-Electrolux 115DD, 115DW User Manual

Introduction

The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters (special accessory).

Extractor The unit features two outlet holes, one of which A is located on the version top of the unit while the other B is located on the rear.

To connect up the hose, you should first fit the bayonet-mounting flange C (100 or 120 mm) on the outlet required (if using the top outlet, fix the flange in place using the screw supplied as shown in Fig. 1).

Close off the unused hole using the bayonet-fitting caps D.

D

 

A

C

 

 

 

¯ 100 mm

 

 

 

 

B

 

¯ 120 mm

 

 

 

1

 

 

 

If using the rear hole, open the air passage by removing the partition (E Fig. 2)

 

E

 

 

Rear

Top

2

outlet hole

outlet hole

Move the lever F to position A Fig. 3.

When connecting up the hood using a telescopic wall pipe, you should use a non-flammable outlet hose No. E 647 000 012 or 647 000 010 (120 mm Ø or 100 mm Ø) from our range of special accessories.

3

The air is filtered and recirculated through the front grille.

Recirculating

 

mode

Move the handle F to position F — Fig. 3 .

 

 

 

EXHAUSTING

A

F

 

ABLUFT

 

EVACUATION

 

 

ASPIRANTE

 

 

 

RECIRCULATION

 

 

MAX 40W

UMLUFT

 

 

RECICLAGE F

 

 

 

FILTRANTE

 

 

3

 

 

 

You will need an original AEG KLF60/80 activated carbon filter for the recirculating mode. (See special accessories).

Summer/winter operation changeover

To avoid unnecessary outdoor transport of thermal energy during exhaust air operation in winter, we reccommend you to convert the fume extractor hood to winter operation (return air). The covering foil over the return air slots is to be removed.

You also need an active carbon filter (special accessory).

When outdoor temperatures become warmer (spring), the active carbon filter is removed again and the fume extractor hood reset to exhaust air operation as per installation sequence. The return air slots on the upper side of the appliance are to be sealed e.g. with self-adhesive aluminium foil. See also for exhaust air operation installation.

4

Voltage and

current

Important

Electrical connections

Please ensure that the voltage and current indicated on the rating plate agree with the voltage of your electricity supply.

If your appliance has been equipped with a mains lead with a moulded-on type plug, you must comply with the following regulations:

The plug moulded on to the lead incorporates a fuse. For replacement, use a 5 amp BS1362 fuse. Only ASTA approved or certified fuses should be used. If the fuse cover/carrier is lost, a replacement cover/carried must be obtained from an electrical goods retailer. If the socket outlets in your home are not suitable for the plug fitted to the appliance, then the plug must be cut off and destroyed for safety reasons, and an appropriate plug fitted.

When wiring the plug ensure that all strands of wire are securely retained in each terminal. Do not forget to tighten the mains lead clamp on the plug.

This unit is screened against radio interference in compliance with European Community directives 87/308 EEC, EN 55014/ DIN VDE 0875 Part 1.

Electrical connections

230 V - using fixed power supply line with plug.

240 V - using fixed power supply line (Great Britain). Fuse rating 13 amps

(The unit should only be connected up by an authorized electrician).

See rating plate for further information.

It is recommended that the socket for the plug is sited above the cooker hood or above the overhead cabinet.

This has 2 advantages:

1)The socket is not visible.

2)The appliance can easily be unplugged when necessary.

If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company. An isolating device is to be provided on the fixed wiring side. Switches with a contact opening of more than 3mm apply as isolating devices.

These include-automatic cut-out switches, fuses and contactors (VDE 0730, s. 7, Part1).

5

Your appliance must be connected to fixed wiring via the use of a double pole swiched fused spur outlet with or without pilot lamp.

We strongly recommend the appliance is connected by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations.

NOTE:

The terminology “DOUBLE POLE” means that both the live and neutral supplies are swiched and disconnected at the same time.

The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance.

IMPORTANT

The wires of the mains lead supplied with this appliance are coloured in accordance with the following code:

Blue-Neutral

Brown-Live

As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The whire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

 

BLUE

BROWN

 

(NEUTRAL)

(LIVE)

 

 

L

 

 

LOAD

 

N

L

 

SUPPLY

 

LOAD

FUSE

ON

DP 13A, 250V

 

 

 

N SUPPLY

Appliances with 2 wires

6

Loading...