AEG-Electrolux HC8836EN User Manual

0 (0)
AEG-Electrolux HC8836EN User Manual

TOOLS AND

MATERIALS REQUIRED (continued)

For Ductfree Installations Only:

One two-pack HF88 Replacement Filter Kit

For Installation On Kitchen Cabinets With Recessed Bottoms

Only:

Two 1” x 2” x 12” (approximate length) wood strips (purchase locally)

Four 1-1/4” long flat head wood screws (purchase locally) to fasten strips to cabinet bottom

PLAN DUCTWORK INSTALLATION

For Ducted Installations Only:

Begin planning ductwork by deciding where duct will run between hood and outside. For best performance, use shortest possible duct run and a minimum number of elbows. In more complex situations, 3-1/4” x 10” duct can be converted to round duct by means of a transition. FIGS 1A - 1E show several choices.

FIG. 1A

WALL CAP

FIG. 1A: Ducting directly through outside wall. If wall cap is used directly off back of hood, check to make sure that damper flap in damper/duct connector on hood does not interfere with damper flap in wall cap. If it does, remove flap on hood damper/duct connector.

FIG. 1B

ELBOW

3-1/4" X 10" DUCT

WALL

CAP

PLAN DUCTWORK

INSTALLATION (continued)

FIG. 1C

ROOF CAP

3-1/4" X 10" DUCT

FIG. 1C: Ducting straight up through roof using 3-1/4” x 10” duct. For single story installations.

FIG. 1D

ROOF CAP

6" ROUND DUCT

3–1/4" X 10" TO 6" ROUND DUCT TRANSITION

FIG. 1D: Straight up through roof using round duct.

ADJUSTABLE ELBOW

FIG. 1E

6" ROUND

DUCT

3–1/4" X 10" TO 6"

ROUND DUCT WALL CAP TRANSITION

FIG. 1B: At times it will be easier to run duct vertically and use an elbow.

FIG. 1E: Ducting between ceiling joists for multi-story

2installations or through soffits above cabinets where soffit connects to outside walls.

PREPARE HOOD

FIG. 2

1. Unpack hood and check contents. You should receive:

1 - assembled hood

1 - plastic bag, containing:

STEP 2 4 - 7/8” wood screws for mounting hood to cabinet

2 - 1/4” black sheet metal screws for mounting damper/ duct connector to hood

2 - aluminum filters

1 - damper/duct connector

For Ductfree Installations Only:

Discard damper/duct connector and two black sheet metal screws.

For Steps 2 - 6 below, refer to FIG. 2.

2. Set hood upside down and remove bottom cover and screws.

3. Remove filters.

4. Remove wiring box cover and screws.

5. To make hood lighter and easier to handle, remove blower assembly.

a.) Unplug blower.

b.) Loosen knurled nuts on mounting rods and slip rods out of blower mounting brackets. Do not remove nuts completely from rods.

c.) Lift out blower and set blower aside.

CAUTION

DO NOT GRASP BLOWER BY BLOWER WHEELS.

WHEELS MAY BE DAMAGED.

6. Remove light lens. Squeeze sides of lens toward center of hood and lift lens out.

7. Remove either top or rear electrical knockout. (FIG. 3)

For Ducted Installations Only:

7. Remove either top or rear duct knockout. (FIG. 3) Fasten damper/duct connector to hood over opening. Use two black sheet metal screws provided in parts bag. (FIG. 3)

FIG. 3

 

VERTICAL DUCTING*

ELECTRICAL

HINGE

PINS

KNOCKOUTS

 

 

DUCT

 

KNOCKOUTS*

HORIZONTAL DUCTING*

HINGE

PINS

* FOR DUCTED INSTALLATIONS ONLY.

3