D 1 T 2 - LIGHTING CONTROLS
FOR THEATRE AND TELEVISION
fixed or transportable installations
APPLICATIONS
ENTERTAINMENT HALLS, CULTURAL CENTRES, SMALL THEATRES,
STROLLING THEATRES, OUTSIDE BROADCASTING UNITS.
Page 2
D1T2
e
Al
l1llllilllll llllllllllll l1ll
37}3sl3sl4ol41 l42]43l44l4sl4sl41:4s
.. .. .. .. ..
:jj
:jj
:jj
:j :j :j :j
:jj
:jj :jj :jj
:jj
:jj
i i
i
i i
:; :;
:jj
:'j :'j
:'j
:! :!
:!
:jj
:jj
·•
:g
:jj
:jj
:jj :j :j
:j
:jj
:jj
i
i
:jj
:'j
:!
:jj
:jj
':j
':y
:jj
:'j
:!
:jj
:jj
:jj
:jj
:;
:'j
:!
b. M S
~EE33~
20,,J?,,,/.. 40
; ..
10\ ,,:. 50
60
!i!J\DB - D1T 2
-r_jj .
~-n=HH
A2]
I "II
·I
:j
~
HHU
1
MAIN ASSETS
Use of modular elements .
The basic module has all required
general control elements and individual channel controls for 12 lighting
control ways .
One to five individual channel control unit modules, each for 12 ways,
can be added as per requirements,
i.e. for a total of 72 ways.
Double light intensity preset per circuit (way).
Four master faders with blackouts
(2 masters per preset) .
Dipless linear crossfader (Transfer
lever) to crossfade between presets.
Reduced cumbersomeness and reduced weight.
Easy to carry , each modular unit is
built as a hand case with carrying
handle and cover lid .
Possibility of using assembly elements to group modular units and to
fit them on a telescopic stand with
casters .
~1~ lHHHH~H u1u uuu uuuuau H~UUH!H uuuuau
1
PRINCIPLE OPERATIONAL
CAPABILITIES
The D1T2 controls enable :
1. Individual control of any circuit
(way) dimming to total extinction
or lighting to full up.
2. Lighting or dimming of several
selected channels simultaneously .
3. Snap in or out of any number of
selected channels. ·
4. Double lever cross fade from an
active cue to a preselected cue.
5. Single lever dipless linear crossfade (transfer) from an active cue
to a preselected cue.
6. Control of any number of circuits
(ways) totally independently of
crossfades or transfers .
OPTION
Operation of the dipless crossfade
(transfer) at selected speeds of
60 sees or
O to 30 minutes .
O to
--
SCHEDULE OF CONTROLS
1. Preset 1.
2. Preset 2.
3. Individual circuit fader.
4. Group selector with 3 position s
to switch the corre sponding circuit to
-Dipl ess linear cros sfader
(transfer lever).
- Tran sfer lever and n° 1 mas-
ter fader of the corr esponding
preset.
-Independant master fader n" 2
of the corresponding preset.
5. Master fader n° 1 of preset 1.
6. Master fader n° 2 of preset 1.
7. Master fad er n" 1 of preset 2.
8. Mast er fader n" 2 of preset 2.
9. General blackout button .
10. Blackout button for preset 1.
11. Blackout button for preset 2.
12. Red/white buttons to connect
presets to the transfer lever
(used also to switch over to th e
CP 36 extra preset module s).
13. Dipl ess lin ear cro ssfader (trans-
fer lever).
15. Potentiom eter for timing speed
selection.
OPTION
Electronic timing of transfer lever action .
Ability of increasing operational
capabilities by adding extra preset
modules type CP 36 as described
futher on.
+ CP36 controls are extenda-
D1T2
ble to a maximum of 48 ways .
Page 3
TO INCREASE THE OPERATIONAL CAPABILITIES OF YOUR D1T2
EXTRA PRESET MODULE CP36
!II· • 91· --N - -N- -- ·II- - -
• H --N· --N- --•· --
N-
II • NI· - -II - -II· --}I --•
M • H --•M• --·II --ii· ---.
!I • !II· --•51 --!II --SIi· -.....-
«I· -... --<II• - -q --•41· --
·t· --~~INJ-~1----1·
ll JI• JI -JI JI• -
zt' 1t· 1t -11• ?t·
It• II• -II• --ll• II•
I-I --· I· --• t· --- • I• --•
1 ii 2 I 3 I 4 I s I a f 1 I a I s 1,01,, t 12
... ff· --•91• --N• --•!II· --•
•· -... - - -•· - - ·-- -•· - - -
11· • NI· --·71• --•NI- --11• --
M· • ii· --·II• --·II· --·'8· --• 1
51· • SI· --•SI· --·!,f· --·H• --
"'! .. ~-~--1-1i··1-~---~~-
... . n- - -... - -. ,,- ---o- --. I
~
: - ·:. = - .:-= ::: -, l
.. ,. It •tl• --.,. ... _ ·It•
I -. I· -I --t· -I• --
~
~
, + 2 I 3 I 4 I s I a 4i 1 I a I s 1 ,o 1 ,, + 12
11
1
)I )I --•- ---)I- -•JI· -
it:
1- =i= -
2' • 11 >-11• -·?I -zt.... •
ll II -•II• --·tl --· It• -·
I · I·
USE
This module is designed to be
to D1T2 control units to increase
operational capabilities .
MAIN ASSETS
Enables addition of three extra light
intensity presets to the two already
existing on the · D1T2 controls .
Fed off the D1T2 control units .
Use of modular units bearing controls for 12 ways each.
1
-· I• --• I --· I·' -·
1
~~1~1
i; =~=1
atlded
1
~;~-=
~
One CP 36 unit is required for each
set of 12 ways of D1T2 controls .
Reduced cumbersomeness and reduced weight.
Easy to carry, each module is built
as a handcase with carrying handle
and lid .
One general master
preset.
Similar design to the D1T2 controls .
Easy connection by means of multipin connectors .
Possibility of using assembly elements to group modules with D1T2
modules and to fix the lot on a
telescopic stand with casters.
MAIN OPERATIONAL
CAPABILITIES
The CP 36 extra preset modules
enable :
1. Individual control of any circuit
(way) dimming to extinction or
lighting to full up.
2. Lighting or dimming of several
selected channels (ways) simultaneously.
3. Double lever crossfade from an
active cue to a preselected cue.
4. Double lever crosstade between
cues respectively on D1T2 presets
and CP 36 presets.
5. Single lever crossfade through the
D1T2 transfer lever from cues selected on the D1T2 presets to
cues on the CP 36 presets and
vice-versa .
fatter per extra
Page 4
SPECIFICATIONS
D1T2
Lighting controls for fixed or trans-
portable installations designed for
the control of ... ways (circuits} with
2 light level presets per circuit, 4
preselection groups (i.e. 2 group
masters per preset} with preset
blackout buttons, dipless linear
crossfader by single lever action
between presets and general black-
out button.
Electronic timing device on the dipless linear crossfader . All required
power supply cables, remote control
cables, interconnection links and
connectors as maybe necessary for
a complete functionning equipment.
CP 36
Extra preset module designed to be
linked with a main control unit and
enabling control of lighting circuits
with 3 preset levels per circuit {way}
and 1 master fader per preset.
All required remote control cables,
interconnection links and connectors
as may be necessary for a complete
functionning equipment.
All technical modification rights reserved.
SPECIFICATIONS AND ARTICLE REF. NUMBERS
Order descriptions
Type D1T2 transportable lighting controls in handcases with lids and
designed for the control of ... dimmable circuits , fitted with double
preset system , 2 master faders per preset, single lever dipless
I inear crossfader to pass from one preset to the other and
comprising :
1 basic modular unit fitted with the following elements .
a) 1 set of general controls i.e. :
- 2 x 2 group master faders
- 2 preset group blackout buttons
- 1 general blackout button
- 1 single lever dipless crossfader with 2 crossfade on/off selector
buttons
b) 12 way Individual controls i.e . :
- 2 x 12 individual faders
- 2 x 12 - 3 position group selectors to switch to :
- independent group master fader
- dipless linear crossfader
- second group master fader and crossfader
Suppl ied without power supply cables remote control
nor connectors .
... Complementary 12 way individual
comprising :
- 2 x 12 individual faders
- 2 x 12
Supplied without remote control cables, links nor
Extra for fitting an electronic timing device to the dipless linear
crossfader system .
Telescopic stand with casters for D1T2 controls .
Extras for assembly elements to group modules for their fitting on
the stand .
... Transportable 12 way extra preset module type CP36 in hand cases
with lids as per catologue leaflet n° ... designed to add 3 presets
to the 2 presets of the D1T2 controls and comprising :
3 x 12 individual faders
3
Supplied without power supply cables, remote control cables, links
nor connectors .
10 meter long power supply cables fitted with 2 connectors
each end)
Extras per extra meter lenght of power supply cable
Power supply connector (one per general control module)
10 meter long remote cable fitted with 2 connectors (one
end) . One cable per six ways.
Remote control connector (one per 6 ways).
Link cable to interconnect modules type D1T2
long with connectors at each end .
Link cable to Interconnect
CP36 modules , 1.5 meter long with connectors al each end.