Non-“H” ServerSpecifications

Physical Specifications

Specification

Value

Height

1.7” (43mm)

Width

16.8” (426mm)

Depth

22.6” (574mm)

Front clearance

2 inches (76mm)

Side clearance

1 inch (25mm)

Rear clearance

3.6 inches (92mm)

Weight

21.0 lbs (9.52 kg)

48

8e6 EnterpriseReporterQuickStartGuide

Hardware Component Specifications

Specification

Value

Operating temperature range

10° C ~ 35° C (50° F ~ 95° F)

Storage temperature range

-40°C ~ +60° C(-40°F ~ 158° F)

Operating humidity range

8 ~ 90% non-condensing

Storage humidity range

5 ~ 95% non-condensing

Power supply

260W AC power supply [24-pin,(4-pin= 12V)]

Rated AC input voltage

100 ~ 240V, 50/60Hz, 5-3Amp

Rated input frequency

50 ~ 60 Hz

Rated input current

5A MAX

Rated output power

260W

Maximum rated BTU

1370 BTUs/Hr

Nominal DC output: +3.3V

15.0A

Nominal DC output: +5V

25.0A

Nominal DC output: +12V

18.0A

Nominal DC output: -12V

1.0A

Nominal DC output: +5V standby

2.0A

Regulatory (power supply)

Power Supply Safety / EMC USA - UL listed, FCC

 

Canada - CUL listed

 

Germany - TUV Certified

 

Europe/CE Mark

 

EN 60950/IEC 60950-Compliant

Internal Product Specifications

Specification

ER3-100

ER3-200

ERS-100

ERS-200

CPU

2.0GHz P4 CPU

2.0GHz P4 CPU

3.6GHz P4 CPU

3.6GHz P4 CPU

Memory

3GB PC2700 /

3GB PC2700 /

3GB PC4200 /

3GB PC4200 /

 

DDR-333Dual

DDR-333Dual

DDR2-533Dual

DDR2-533Dual

 

Channel RAM

Channel RAM

Channel ECC

Channel ECC

 

 

 

RAM

RAM

Hard drive

2x250GB HDD

2x250GB HDD

1x250GB HDD

2x250GB HDD

capacity

 

 

1x400GB HDD

 

Connectivity

10/100/1000

10/100/1000

10/100/1000

10/100/1000

8e6 EnterpriseReporterQuickStartGuide

49

Front Panel LED Indicators and Buttons

Diagrams and Descriptions

LED indicators and buttons display on the front panel, to the right:

E D C B A

F G

LED indicators alert you to the status of a feature on the unit while buttons let you perform a function on the unit.

LED Indicators and Buttons

LED Indicator Key

Button Key

A. Power

F. Reset

B. HDD Activity

G. Power

C. LAN 1

 

D. LAN 2

 

E. Overheat

LED Indicator

Color

Condition

Description

Power

Green

On

System On

 

 

Off

System Off

HDD

Amber

Blinking

HDD Activity

 

 

Off

No HDD Activity

LAN 1 & LAN 2

Green

On

Link Connected

 

 

Blinking

LAN Activity

 

 

 

 

 

 

Off

Disconnected

Overheat

Red

On

System Overheated

 

 

Off

System Normal

50

8e6 EnterpriseReporterQuickStartGuide

“H” ServerSpecifications

Physical Specifications

Specification

ERH-100Value

ERH-200Value

Height

1.7” (43mm)

1.7” (43mm)

Width

17.2” (438mm)

17.2” (438mm)

Depth

26.8” (681mm)

26.8” (681mm)

Front clearance

2 inches (76mm)

2 inches (76mm)

Side clearance

1 inch (25mm)

1 inch (25mm)

Rear clearance

3.6 inches (92mm)

3.6 inches (92mm)

Weight

43.0 lbs (19.5 kg)

44.0 lbs (19.96 kg)

8e6 EnterpriseReporterQuickStartGuide

51

Hardware Component Specifications

Specification

Value

Operating temperature range

10° C ~ 35° C (50° F ~ 95° F)

Storage temperature range

-40°C ~ +60° C(-40°F ~ 158° F)

Operating humidity range

8 ~ 90% non-condensing

Storage humidity range

5 ~ 95% non-condensing

Power supply

560W Hot-swapredundant AC power supply with

 

PFC [ 24-pin,(8-pin= 12V) ]

Rated AC input voltage

100 ~ 240V, 60-50Hz,10-5Amp per power supply

 

module (two modules included in the chassis)

Rated input frequency

50 ~ 60 Hz

Rated input current

10A (115V) to 5A (230V)

Rated output power

560W

Maximum rated BTU

N/A (see specs below)

Nominal DC output: +3.3V

21.0A

Nominal DC output: +5V

30.0A

Nominal DC output: +12V

42.0A

Nominal DC output: -12V

1.0A

Nominal DC output: +5V standby

4.0A

Regulatory (power supply)

EN 60950/IEC 60950-Compliant

 

UL Listed (USA)

 

CUL Listed (Canada)

 

TUV Certified (Germany)

Internal Product Specifications

Specification

ERH-100

ERH-200

CPU

2x3.6GHz Xeon CPU

2x3.6GHz Xeon CPU

Memory

4GB PC2700 / DDR-333ECC

4GB PC2700 / DDR-333ECC

 

SDRAM

SDRAM

Hard drive capacity

4x250GB HDD

4x400GB HDD

Connectivity

10/100/1000

10/100/1000

52

8e6 EnterpriseReporterQuickStartGuide

Front of Chassis: Control Panel

Control panel buttons, icons, and LED indicators display on the right side of the front panel. The buttons let you perform a function on the unit, while an LED indicator corresponding to an icon alerts you to the status of that feature on the unit.

The buttons and LED indicators for the depicted icons function as follows:

UID (button) – When the UID button is pressed, a steady blue LED displays on both the front and rear of the chassis (see also Rear of Chassis). These indicators are used for easy location of the chassis in a large stack configuration. The LED remains on until the button is pressed a second time.

Overheat/Fan Fail (icon) – This LED is unlit unless the chassis is overheated.

NIC2 (icon) – A flashing green LED indicates network activity on LAN2.

NIC1 (icon) – A flashing green LED indicates network activity on LAN1.

HDD (icon) – In addition to displaying in the control panel, this icon also displays on the front panel on each hard drive carrier. A green LED indicates hard drive activity. An unlit LED on a drive carrier may indicate a hard drive failure.

Power (icon) – The LED is unlit when the server is turned off. A steady green LED indicates power is being supplied to the unit’s power supplies. (See also Rear of Chassis.)

Power (button) – When the power button is pressed, the main power to the server is turned on. When the power button is pressed again, the main power to the server is removed but standby power is still supplied to the server.

8e6 EnterpriseReporterQuickStartGuide

53

Rear of Chassis

UID (LED indicator) – On the rear of the chassis, to the left of the power supplies, a steady blue UID LED indicator displays when the UID button on the control panel is pressed. This LED remains lit until the UID button is pressed again.

Power Supplies (LED indicators) – The power supplies are located at the right on the rear of the chassis. An LED indicator is located above each of the power plugs.

54

8e6 EnterpriseReporterQuickStartGuide

RegulatorySpecifications andDisclaimers

Declaration of the Manufacturer or Importer

Safety Compliance

 

Europe:

Low Voltage Directive (LVD) 73/23/EEC to CB Scheme EN 60950:2001 +A11

 

International:

TUV/CB to IEC 60950-1:2001+A11 1st Edition

Electromagnetic Compatibility (EMC)

 

 

 

 

USA:

FCC CFR 47 Part 15, Verified Class A Limit

 

Canada:

IC ICES-003Class A Limit

 

China:

China Compulsory Certification (CCC)

 

 

GB4943-2001,GB9254-1998(Class A),GB17625.1-2003

 

Europe:

EMC Directive, 89/336/EEC & Low Voltage Directive (LVD) 73/23/EEC

Federal Communications Commission (FCC) Class A Notice (USA)

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

FCC Declaration of Conformity

Models: 5K02-51,5K02-52,5K02-55,5K02-56

8e6 EnterpriseReporterQuickStartGuide

55

Electromagnetic Compatibility Class A Notice

Industry Canada Equipment Standard for Digital Equipment (ICES-003)

China Compulsory Certification (CCC) - China

56

8e6 EnterpriseReporterQuickStartGuide