Size:
341.28 Kb
Download

3MAir-Mate Self-Contained

Breathing Apparatus (SCBA)

3Innovation

3MAir-Mate Combination

 

5 min.

Escape Self-Contained Breathing Apparatus

15 min.

(ESCBA)/Supplied Air Respirator (SAR)

Supplied

 

 

Air

Versatility in IDLH conditions

 

 

and supplied air respirator,

Improved lightweight design makes it ideal for

 

offers a high level of

petrochemical, nuclear, hazardous materials handling,

 

that are

waste treatment, confined spaces and other IDLH, or

 

and

applications.

 

5 minute

Full facepiece features quarter-turn pressure-demand valve for a secure attachment.

First-breath activation allows the unit to be donned in a non-hazardous environment before connecting the pressure-demand valve.

Airline connection enables wearer to remain in IDLH atmospheres for extended periods of time.

Improved harness design secures the air cylinder to the leg, providing maximum comfort and confidence when working in IDLH environments.

Interchangeable 5- and 15-minute cylinders allow flexibility for different applications and

escape needs.

3M Air-Mate Combination ESCBA/SAR Ordering Information

Part No.

Description

Cylinder Type

PSI

Rated Duration

Vest Harness Material

BA-3205-S

5 minute (small facepiece)

Aluminum

2216

5 Min.

Nylon

BA-3205-M

5 minute (medium facepiece)

Aluminum

2216

5 Min.

Nylon

BA-3205-L

5 minute (large facepiece)

Aluminum

2216

5 Min.

Nylon

BA-3215-S

15 minute (small facepiece)

Hoop Wrapped

3000

15 Min.

Nylon

BA-3215-M

15 minute (medium facepiece)

Hoop Wrapped

3000

15 Min.

Nylon

BA-3215-M

15 minute (large facepiece)

Hoop Wrapped

3000

15 Min.

Nylon

BAP-2005673

Cylinder, Valve and Pouch

Aluminum

2216

5 Min.

 

BAP-2005672

Cylinder, Valve and Pouch

Aluminum

2216

5 Min.

 

Alternate airline fittings available.

3MAir-Mate 2000

Self-Contained Breathing Apparatus (SCBA)

Maximum protection, maximum durability

30 min.

Supplied

Air (Optional)

The Air-Mate 2000 system is for workers who require respiratory protection for environments that are immediately dangerous to life and health

approved for both entry into

confined spaces. Optional airline connection enables the wearer to remain in IDLH atmospheres for extended

Easily viewable shouldermounted, low-pressure gauge indicates cylinder air pressure.

Audible end-of-service alarm alerts wearer of low air supply.

Full facepiece features quarter-turn pressuredemand valve for a secure attachment.

First-breath activation allows the unit to be donned in a nonhazardous environment before connecting the pressure-demand valve.

Built-in speaking diaphragm allows clear communication with co-workers.

Quick-release cylinder band clamp makes cylinder changes quick and easy.

Single-piston, first-stage, fail-open regulator has few moving parts, improving dependability and reducing maintenance costs.

Ergonomically designed backplate distributes weight evenly, providing maximum comfort.

3M Air-Mate 2000 SCBA Ordering Information

Part No.

Description

Cylinder Type

PSI

Rated Duration

Vest Harness Material

BA-2430-S

2000

(small facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BA-2530-S

2000 w/Airline (small facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BA-2430-M

2000

(medium facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BA-2530-M

2000 w/Airline (medium facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BA-2430-L

2000

(large facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BA-2530-L

2000 w/Airline (large facepiece)

Aluminum

2216

30 Min.

CorduraNylon

BAP-2003933

Cylinder and Valve

Aluminum

2216

30 Min.

 

3MAir-Mate

SCBAGSelf-Contained Breathing Apparatus (SCBA)

30 min.

Supplied

Air (Optional)

Nothing is more convenient

The SCBAG system is unlike any other product in its class.

and it makes training simple. It’s NIOSH-approved for both

It’s stored in a unique, reversible carrying bag that opens to

entry into and escape from confined spaces. Optional airline

form a vest with the SCBA system in place and ready to

connection enables wearer to remain in IDLH atmospheres

use. Portable and donned easily

time.

it’s perfect for confined spaces

 

Full facepiece features quarter-turn pressure-demand valve for a secure attachment.

First-breath activation allows the unit to be donned in a nonhazardous environment before connecting the pressuredemand valve.

Easily viewable shouldermounted, low-pressure gauge indicates cylinder air pressure. Audible end-of-service alarm alerts wearer of low air supply.

Lightweight, vest-style harness features improved shoulder and back padding and distributes weight evenly for greater comfort.

Adjusts up to 58in chest size for improved fit.

Front pouch stores and protects the facepiece until needed.

Hook-and-loop harness closure adjustment provides fast and easy donning.

3M Air-Mate SCBAG SCBA is a bag that opens to form a vest with the SCBA system in place and ready to use. The SCBAG is available with a durable, black Corduranylon harness or a flame-resistant brown AdvanceHarness.

Lightweight, hoop-wrapped, 30-minute cylinder is positioned for ideal weight distribution and easier valve access.

3M Air-Mate SCBAG SCBA Ordering Information

Part No.

Description

Cylinder Type

PSI

Rated Duration

Vest Harness Material

BA-4430-S

SCBAG (small facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4530-S

SCBAG w/Airline (small facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4430-M

SCBAG (medium facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4530-M

SCBAG w/Airline (medium facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4430-L

SCBAG (large facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4530-L

SCBAG w/Airline (large facepiece)

Hoop Wrapped

4500

30 Min.

CorduraNylon

BA-4630-S

SCBAG (small facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BA-4730-S

SCBAG w/Airline (small facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BA-4630-M

SCBAG (medium facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BA-4730-M

SCBAG w/Airline (medium facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BA-4630-L

SCBAG (large facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BA-4730-L

SCBAG w/Airline (large facepiece)

Hoop Wrapped

4500

30 Min.

Advance

BAP-2003930

Cylinder and Valve

Hoop Wrapped

4500

30 Min.

 

3MAir-Mate SCBAG

SCBA Harness Donning

Procedures

1

 

is a self-contained system

 

the bag and open on a flat

 

in its own carrying bag.

 

with the cylinder valve

 

 

pointing toward you.

 

 

 

 

3

 

4

 

 

 

 

Separate the hook-and-loop

SCBAG over so the

fasteners holding the flaps together

cylinder is underneath and the

up the vest.

carrying straps are on top.

5

6

zippered flap toward the fasten the hook-and-loop

fasteners, enclosing the carrying the pre-operational

inspection specified in the

.

vest at the shoulder flaps inside of the vest facing you.

7

8

right arm into

left arm into the armhole

.

hoses and gauge. Position

 

on your back as you

 

jacket or vest.

10

Smooth the right side against your stomach, then fold the left

side across to secure the hook-and- loop fasteners.

Fasten the waist belt tang to the buckle strap extending from the right side of the facepiece pouch. To tighten, pull the free end of the waist belt away from the buckle tang. To loosen, pull the buckle and tang away from the fixed end of the waist belt.

3MAir-Mate 7800S-AM

Full Facepiece Donning

Procedures

1

cylinder valve.

 

With the headstraps fully extended

 

 

and placed out over the front of the

 

 

facepiece, place your chin into the

 

 

chin cup and hold the facepiece

 

 

snug against your face.

 

 

 

3

 

4

 

 

 

Pull the headstraps down over the back of your head, brushing away any hair from the sealing surface. Your first breath will activate the system, letting you breathe freely.

Pull straight back on the headstraps to tighten. Start with the lower chin straps and work your way up to the top straps.

Positive Pressure/Regulator Test Emergency Bypass Test

Insert two fingers between your cheek and the facepiece, and gently lift the facepiece away. A good outward flow of air indicates the facepiece pressure is positive. After removing your fingers to reseal the facepiece, there should be no air leaking from the pressure-demand valve or facepiece.

Open the pressure-demand valve by rotating the red emergency by-pass knob a quarter turn until it stops.

There should be a constant flow of air into the facepiece. Turn the knob back to the closed position, with the flat part of the knob pointed toward you.

User Seal Check/Low Pressure Alarm Tests

Close the cylinder valve and breathe normally. Observe the pressure gauge and listen for the low-pressure audible alarm as the pressure gauge moves into the red zone. Continue breathing until the facepiece collapses slightly against your face. Inhale gently and hold your breath. If the facepiece remains collapsed for several seconds, you have a correct seal. Return the cylinder valve to the

open position.

3M7800S Series Full Facepiece Family

The 7800S series full facepiece family offers the versatility to standardize with one full facepiece family for all of your applications. From negative pressure to self-contained- breathing apparatus, the easy-to-use 7800S series full facepiece family will provide unsurpassed comfort and security to your workers. Double-flanged silicone face seal

provides a comfortable fit for a large variety of face sizes and shapes. Six-point adjustable straps provide a secure fit. Standard speaking diaphragm provides clear communication. And since fit testing requirements are identical across all 7800S series configurations, one passing fit test meets

OSHA requirements for all your applications.

7800S

7800S-AM

 

t

 

e

U

s

 

Face-mounted PAPR***

 

One fit

 

for every

2000 SCBA**

function

 

3MAir-Mate

 

(30 minute)

Belt-mounted PAPR

 

Dual airline supplied air

respirator

Pressure demand respirator

Supplied air respirator

*Escape Self-Contained Breathing Apparatus

**Self-Contained Breathing Apparatus

***Powered Air Purifying Respirator

-

 

A

M

 

f

 

o

 

r

and

3MAir-Mate Airline Hoses Ordering Information

Description

Part No.

 

Description

Part No.

25 ft. (7.5 m) Neoprene, Hansen 1000, fitting not removable

367-01-02R01

 

25 ft. (7.5 m) Neoprene, Schrader

367-01-02SC1

50 ft. (15.0 m) Neoprene, Hansen 1000, fitting not removable

367-02-02R01

 

50 ft. (15.0 m) Neoprene, Schrader

367-02-02SC1

100 ft. (30.0 m) Neoprene, Hansen 1000, fitting not removable 367-03-02R01

 

100 ft. (30.0 m) Neoprene, Schrader

367-03-02SC1

25 ft. (7.5 m) Neoprene, Hansen 1000

367-01-02HA1

 

25 ft. (7.5 m) Neoprene, Hansen HK

367-01-02HK1

50 ft. (15.0 m) Neoprene, Hansen 1000

367-02-02HA1

 

50 ft. (15.0 m) Neoprene, Hansen HK

367-02-02HK1

100 ft. (30.0 m) Neoprene, Hansen 1000

367-03-02HA1

 

100 ft. (30.0 m) Neoprene, Hansen HK

367-03-02HK1

25 ft. (7.5 m) Neoprene, Foster

367-01-02FS1

 

25 ft. (7.5 m) EPDM, Blue, Hansen S22

W-9435/S22-25

50 ft. (15.0 m) Neoprene, Foster

367-02-02FS1

 

50 ft. (15.0 m) EPDM, Blue, Hansen S22

W-9435/S22-50

100 ft. (30.0 m) Neoprene, Foster

367-03-02FS1

 

100 ft. (30.0 m) EPDM, Blue, Hansen S22

W-9435/S22-100

 

 

 

 

 

Use Limitations

1.Failure to comply with all instructions and warnings on the use of these products and/or failure to wear the respirator during all times of exposure may reduce respirator effectiveness and result in serious bodily injury, sickness or death.

2.Never alter or modify these respirators.

3.Repair or replace respirator parts if they become damaged. Use appropriate 3M parts only.

4.Use of the equipment described in this brochure should be in accordance with applicable safety and health standards, respirator selection tables contained in such publications as ANSI Z88.2-1992, or pursuant to the recommendations of an industrial hygienist.

5.If you have any doubts about the applicability of the equipment to your job situation, it is recommended you consult your supervisor, an industrial hygienist or call 3M Occupational Health and Environmental Safety Division (OH&ESD), Technical Service Department at 1-800-243-4630.

Before using any of the respiratory products pictured in this brochure, the wearer must read and/or understand all warnings, use limitations and fitting instructions accompanying each product. Failure to do so may result in serious bodily injury, sickness or death.

Use of 3MRespirators by untrained or unqualified persons, or use not in accordance with the User Instructions, may adversely affect product performance and result in serious bodily injury, sickness or death.

Each respirator must be properly selected based on the contaminant and concentration levels to which the worker is exposed.

3M respirators are to be used only by qualified persons properly trained in their use and maintenance, and only in accordance with their User Instructions. Each person using these products must first read and understand the User Instructions. Failure to do so may result in serious bodily injury, sickness or death.

The compressed air used with and SCBA, Escape SCBA or supplied air system shall meet at least the requirements for grade D breathing air per Compressed Gas Association Commodity Specification, CGA G-7.1-1989 and 29CFR1910.134(i), in the United States, and Table 2 of the CSA Standard CAN3-Z180,1-M85, in Canada. The compressor shall be equipped with safety and standby devices per OSHA Standard 1910.134 or CSA Standard CAN3-Z180.1-M85 in Canada.

Be sure breathing air couplings are incompatible with outlets for nonrespirable plant air or other gas systems to prevent servicing of airline respirators with nonrespirable air or oxygen. Use of nonrespirable air will cause serious bodily injury, sickness or death.

The employer must also have established a satisfactory respirator program such as described in OSHA Standard 1910.134 or CSA Standard Z94.4-93 in Canada.

For more information

In United States, contact:

In Canada, contact:

For other 3M products:

Technical Assistance

Technical Assistance

1-888-3M-HELPS

1-800-243-4630

1-800-267-4414

or 1-612-737-6501

Sales Assistance

Marketing Assistance

 

1-800-896-4223

1-800-265-1840, ext. 6137

 

Fax-on-Demand

Internet

 

1-800-646-1655

www.3M.com/intl/CA/

 

Internet

ohes.html

 

www.3M.com/occsafety

E-mail

 

E-mail

ohes@ea.mmm.com

 

occsafety@mmm.com

 

 

3

Occupational Health and

3M Canada Company

Environmental Safety Division

OH&ES

3M, the 3M logo, Air-Mate and SCBAG are trademarks of 3M.

Cordura and Advance are registered trademarks of DuPont.

3M Center, Building 235-2W-70

P. O. Box 5757

P.O. Box 3010

London, Ontario N6A 4T1

St. Paul, MN 55133-3010

Canada

 

 

Copyright © 2001, 3M IPC.

40%

Pre-consumer waste paper

All rights reserved.

 

10%

Post-consumer waste paper

70-0710-4221-5