2250ME 2250ME-iD 2273ME 2273ME-iD

February 2009

3

78-8130-6151-8-E

Contents

 

Safety Information.................................................................................................

4

About This Manual................................................................................................

4

Quick Start.............................................................................................................

5

Menu Screens......................................................................................................

10

Configuring The Receiver....................................................................................

12

Buried Cables And Pipes.....................................................................................

15

Receiver Modes...................................................................................................

18

Depth and Current Estimate................................................................................

20

Frequencies..........................................................................................................

21

Locating in Directional Peak Mode.....................................................................

22

Locating Active Duct Probes (Sondes)................................................................

25

Buried Sheath Faults And Earth/Return Faults....................................................

26

3MElectronic Markers and 3MEMS iD Markers.........................................

28

Locating 3MEMS Markers...............................................................................

29

Marker Depth Estimate........................................................................................

31

Creating/Editing Templates for 3MEMS iD Markers......................................

33

Writing iD Markers.............................................................................................

36

Modifying Marker Data to be Programmed........................................................

37

Reading iD Markers.............................................................................................

38

GPS Operation.....................................................................................................

39

Reviewing Marker History..................................................................................

43

Other Applications...............................................................................................

44

Cable Identification.............................................................................................

45

Help Mode...........................................................................................................

46

3MDynatelPC Tool Kit.................................................................................

46

Self Test Of Receiver...........................................................................................

47

Product Description And Optional Accessories...................................................

47

Receiver Specifications........................................................................................

49

2

78-8130-6151-8-E

Congratulations! You have just purchased one of the finest, most advanced locating devices available today!

The 3MDynatelCable/Pipe/Fault Locators 2250ME-iD/2273ME-iD are designed with all of the functionality of previous Dynatel models, and iD versions have the enhanced capability to read and write user information into the 3M EMS iD markers. Information such as a pre-programmed identification number, facility data, application type, placement date and other details can all be read, stored and downloaded to your PC for enhanced resource management with this revolutionary equipment. The Dynatel Cable/Pipe/Fault Locators 2250ME-iD/2273ME-iD will also search for two different types of utility markers simultaneously. When used in conjunction with a hand-held GPS the ability to transmit path and marker coordinates multiplies the potential to

the mapping industry. This equipment provides a simple system for mapping utility information directly into CAD and GIS systems.

3M is dedicated to bringing you premium equipment with outstanding reliability, backed by one of the best warranties in the business and outstanding service.

Visit our website at http://www.3M.com/dynatel for more application notes.

78-8130-6151-8-E

3

Safety Information

Please read, understand and follow all safety information contained in these instructions prior to the use of the 3M Cable/Pipe/Fault Advanced ME-Series Locator. Retain these instructions for future reference.

Intended Use

The 3M Cable/Pipe/Fault Advanced ME-Series Locator is used to identify the placement of underground utility lines. The system must be installed as specified in the 3M Cable/ Pipe/Fault Advanced Locator 2250ME/2273ME Series Operator Manual. It has not been evaluated for other uses or locations. If this equipment is used in a manner not specified by 3M, the protections provided by the equipment may be impaired.

m WARNING

If this equipment is used in a manner not specified by 3M, the protections provided by the equipment may be impaired.

Explanation of Signal Word Consequences

m Warning: Indicates hazardous situation which if not avoided, could result in death or serious injury.

m Caution: Indicates hazardous situation which if not avoided, could result in minor or moderate injury.

Explanation of Product Safety Label Symbols

Do not throw away in normal trash.

cWarning: Risk of electric shock

About This Manual

There are two basic models included in the 3M Dynatel Locator 2200M Series. The 2250ME is designed for cable/pipe locating. The 2273ME is designed for cable/pipe and fault locating. The iD option (read/write capability to 3MTM EMS iD Markers) is available for both models. There are three transmitter options: 3 Watt, 5 Watt, or 12 Watt. This instruction manual will include all features. All instructions are applicable to all products, unless noted.

In order to demonstrate all available functions, the illustrations depict the 2273ME-iD receiver unit and the 12-watt transmitter. The 2250ME may vary from the illustrations shown.

4

78-8130-6151-8-E

Quick Start

Transmitter Battery Installation

Loosen the six screws on the battery compartment cover on the bottom of the transmitter. Remove the cover.

Install six ‘C’ cell batteries (LR14) into the compartment as indicated by the polarity symbols (+ and –).

Replace the cover and tighten the screws.

Press and hold OFF [T-1] to manually test the batteries. The display and audio will indicate one of the following levels: (OK w/solid tone = good; LO w/beeping tone = low; "--" w/no tone = replace)

m Caution

To reduce the risks associated with fire and explosion:

Do not short, excessively heat, or dispose of batteries in fire.

Install batteries with proper polarity.

Use only Alkaline "C" (LR14) sized batteries.

Do not charge batteries

Do not use leaking batteries

To reduce the risks associated with environmental contamination:

Dispose of batteries and electronic components in accordance with all regulations.

Ensure batteries are installed with correct polarity.

Always remove batteries when storing the units for long periods of time.

78-8130-6151-8-E

5

Receiver Battery Installation

Remove cap from receiver handle.

Install eight ‘AA’ cell batteries (LR6) into the battery holder as indicated by the polarity symbols (+ and –).

Attach battery holder to the PP3 connector in the receiver handle, and slide holder into the handle. Replace the cap.

8 “AA” Alkaline Batteries

1. Twist cap to open battery compartment.

2. Slide battery compartment out of handle.

m Caution

To reduce the risks associated with fire and explosion:

Do not short, excessively heat, or dispose of batteries in fire.

Install batteries with proper polarity.

Use only Alkaline "AA" (LR 6) sized batteries.

Do not charge batteries

Do not use leaking batteries

To reduce the risks associated with environmental contamination:

Dispose of batteries and electronic components in accordance with all regulations.

Ensure batteries are installed with correct polarity.

Always remove batteries when storing the units for long periods of time.

The receiver batteries are tested for two seconds every time the unit is turned on.

The bar graph on the screen will fill to the relative battery level.

The Battery Icon [8] on the Locate Screen will continuously indicate the battery level.

Cleaning

To clean the unit, wipe with a damp cloth.

6

78-8130-6151-8-E

Service and Accessories

Information regarding service, accessories, or replacement parts can be obtained by contacting your local 3M Sales Office or 3M Sales Representative.

This equipment does not require annual calibration or maintenance.

Transmitter Keypad and Connector Definitions

T-1

T-2

T-3

T-4

T-5

T-6

T-7

OFF: [T-1] Turns unit off and performs battery test.

OHM / FAULT / TONE: [T-2] Turns the unit on and cycles through the following commands when pressed repeatedly.

OHM METER: Measures the continuity of the trace conductor/pipe and its far-end ground. It is also used to measure the fault resistance to earth.

FAULT LOCATE: (2273ME units only) In this mode, the transmitter sends two alternating frequencies (577 Hz and 33 KHz) as well as fault signals 10 and 20 Hz.

TONE: In the tone mode, the transmitter generates 577 Hz and 133 KHz signals.

TRACE: [T-3] Turns the unit on and places the unit in Trace mode.

SELECT FREQUENCY: Press TRACE [T-3] repeatedly to cycle the frequency of the transmitter (577 Hz, 8 KHz, 33 KHz, and 133 KHz). The selected frequency will be displayed [T-4]. ‘ALL' indicates that multiple frequencies are transmitting simultaneously.

DISPLAY: [T-4]

INDICATOR FLAGS: These flags coincide with the operational mode of the transmitter. (From top left to bottom right) Fault mode [T-2] (2273ME units only), Tone [T-2], Trace mode [T-3], Ohm meter [T-2], Voltage (at start up the transmitter checks for foreign voltage), and the Output Flag (no flag = low output; flag = high output; flashing flag = maximum output).

DIGITAL DISPLAY: Indicates frequency, relative current, resistance, battery level and voltage.

OUTPUT: [T-5] Cycles output level; normal, high and maximum.

Normal=No Flag; High=Flag; Maximum=Flashing Flag

OUTPUT JACK: [T-6] Port for direct connect cables or Dyna coupler.

EXTERNAL JACK: [T-7] Port to connect cigarette lighter adapter cable, or rechargeable battery (2200RB). Input voltage level: 9-18 VDC.

78-8130-6151-8-E

7

Maximum Transmitter Output

An external 12V DC source is required for 12-Watt Output. Connecting the rechargeable battery (2200RB) to the external jack [T-7] will provide this external source, or the cigarette lighter adapter cable (included with high powered units) can be used to connect the DC power from a vehicle’s battery source to the transmitter’s external jack {T-7}.

Press Output [T-5] twice for maximum output mode.

The indicator flag will flash when the transmitter is in max output mode.

Note: The external DC source does not charge the internal batteries.

m WARNING

To reduce the risk associated with hazardous voltage:

Potential for electric shock exists when handling connection cables while the transmitter is ON. Make all connections prior to powering on the unit. Turn transmitter OFF before handling connection cables.

Voltage greater than 240 volts will damage equipment and could cause personal injury or death. Make all connections before turning on the transmitter. Follow standard procedures for reducing the voltage.

Do not change or modify this product in any way.

Rechargeable Battery

The 3M Dynatel Sealed Gel-Cell Battery 2200RB can be used as an auxiliary battery in 3MDynatel2200 Series Transmitters. It plugs into the external jack [T-7] and provides power for the transmitter. When the rechargeable battery is plugged in, normal output, high output, and maximum output is available. When the rechargeable battery is

connected to the transmitter, the alkaline batteries are bypassed. The rechargeable battery is a lead acid battery rated at 5.4 amp-hours and is equipped with a user replaceable fuse (5A/32V).

Note: The internal batteries must be at least 5.4 volts. Do not remove the alkaline batteries from the transmitter when using the rechargeable battery.

8

78-8130-6151-8-E

Receiver Key Pad Definitions

POWER: [1] Turns unit off and on.

SPEAKER: [2] Adjusts the volume of the receiver (off, low, med, high, and Xpand).

SPEAKER ICON [2A]: Indicates the relative volume level of the receiver. When the third ring is dotted and ‘xpnd' appears below the speaker icon, the receiver is in “Expander” mode. This mode is used to pinpoint the target cable or pipe.

CONTRAST: [3] The arrows located above and below the contrast icon will adjust the contrast of the screen.

GAIN: [4] Adjusts the sensitivity of the receiver either up or down to maintain a satisfactory signal level.

LOCATE/OK: [5] Sets the receiver to trace mode for locating cable or pipe. Acknowledges setup entries (OK).

MENU: [6] Displays setup screen for configuration of the unit, i.e.: clock, language, depth units, marker data and frequencies.

BACKLIGHT: [7] Toggles the backlight low, high, and off. BATTERY ICON: [8] Indicates battery level.

SOFT KEY: [SK] There are four soft keys on the receiver. The function of each key is shown above the key on the display screen. The functions will change, depending on the operation mode of the receiver. For instruction purposes, the display command is followed by [SK] to identify it as a soft key.

SOFT KEY COMMAND: [9] Definitions for each of the four soft key functions. SIGNAL STRENGTH: [10] Digital reading of the signal the receiver is detecting. BAR GRAPH: [11] Graphical representation of the received signal.

GAIN LEVEL: [12] Displays relative gain level.

EXTERNAL JACK: [l3] Port to connect cables from external devices such as the earth frame, a second Dyna-Coupler, or toning coil.

SERIAL PORT: [14] RS232 port to connect the receiver to a PC via straight serial cable (not included).

EARPHONE JACK: [15] Will fit standard 1/8 inch mini-jack mono earphone plug (not included).

78-8130-6151-8-E

9

3M 2273ME-iD, 2250ME, 2273ME, 2250ME-iD User Manual

Menu Screens

Main Menu

When the Menu [6] button is pressed, the Main Menu screen appears.

The function appears on the screen above each soft key.

1.Write Mode: System used to write information to RFiD Markers

2.Data/Template: Displays marker history and template creation/selection screens:

a.Read History – 100 memory locations for Read RFiD Markers

b.Write History – 100 memory locations for Programmed RFiD Markers

c.User Templates – Create and edit RFiD templates for RFiD Markers (max =32)

d.Trace Templates – Create and edit templates used to identify path (max = 5)

3.COM Setup: Displays second level COM Port setting screen to configure RS232 port communication with different devices –

a.PC – Receiver will communicate to a computer

b.NMEA – Port is configured to accept coordinates from GPS

c.GIS – Port is configured to send RFiD information or path information to GPS device and receive coordinates from GPS.

d.PDA – receiver will send RFiD and path information in ASCII string.

4.More>>: Advances to next menu screen

10

78-8130-6151-8-E

5.Back<<: Returns to previous screen

6.Setup: Displays second and third level screens for receiver configuration

a.Depth Units – Choose unit of measure; in, ft-in, or cm

b.Clock – Date and time stamped on marker information and depth readings.

c.Language – Toggles between English and alternate language

d.More>> - Advances to next menu screen

e.Back<< - Returns to previous screen

f.Marker Type – enable and disable marker utility types

g.Locate Frequencies – enable and disable receiver frequencies in locate mode

h.Tone/Freq - External Port or Tone Frequencies – enable and disable frequencies that are detectable through the external port of the receiver

i.Power Filter Frequency – Select the power frequency of the region to aid in 50/60 Hz interference rejection

j.Audio Configuration – Select audio response of unit in Directional Peak mode

78-8130-6151-8-E

11

7.Self Test: Displays information about unit and performs a self check test

8.Help: Offers the user on-screen instructions

Configuring The Receiver

In the setup mode, the units of depth measurement, time, date, and date format can be set. The receiver can be configured to detect only certain frequencies and/or specific utility markers. User defined frequencies can be programmed, language of the receiver can be selected, and tone frequencies set.

Select Depth Units

MENU [6] + More>>[SK] + Setup [SK] + Units [SKToggle]

Press Units [SK toggle].

The soft key command will toggle between inches (in), centimeters (cm), and feet/inches (ft-in).

Setting the Receiver Clock

Set the time, date, and date format of the receiver. Depth and Current measurements are time and date stamped, as well as read write marker information (iD units only).

MENU [6] + More>>[SK] + Setup [SK] +Clock [SK]

Press the left/right arrow [SK] to highlight the digit of the date or time to change.

Press the + or - [SK] to increment or decrement.

When the date format is highlighted, the format will toggle between mm/dd/yy and dd/mm/yy.

Press OK [SK] to save, or Menu [6] to cancel.

Selecting a Language

MENU [6] + More>>[SK] + Setup [SK] + Lang [SKToggle]

The soft key command will cycle through available languages. Alternate languages can be uploaded to the receiver using the DynatelPCTools software. (Available for download at www.3M.com/dynatel.)

12

78-8130-6151-8-E

Enabling/Disabling Frequencies

MENU [6] + More>>[SK] + Setup [SK] + + More» [SK] + Locate Freq [SK]

The user can select the frequencies that the receiver will detect. All the available frequencies are listed in four groups (Left to Right: Active, Power, Passive, and Auxiliary). The Auxiliary group also contains the User Defined Frequencies. (See Creating User Defined Frequencies.)

1.Press the right arrow [SK] to move the highlight bar to the section of frequencies to enable, or disable.

2.Press the up/down arrows [SK] to highlight the specific frequency.

3.Press Enabl/Disabl [SK]. (Enable denoted by 3)

4.Repeat steps 2 & 3 to enable/disable other frequencies.

5.Press OK [5] to save.

Selecting External Jack Frequencies (Tone Frequencies)

MENU [6] + More>>[SK] + Setup [SK] + + More» [SK] + Tone Freq [SK]

A coupler can be plugged into the external jack of the receiver and used to identify cables. (See Other Applications: Cable Identification.) The same procedure as above is followed for selecting

frequencies that can be detected by the external jack found on the bottom of the receiver.

Creating User Defined Frequencies

MENU [6] + More>>[SK] + Setup [SK] + + More» [SK] + Locate Freq [SK]

There are four user defined frequencies available on the receiver. (These frequencies must be between 50 Hz and 999 Hz.) These frequencies are found in the column on the far right of the Locate Freq screen (Auxiliary frequencies). These frequencies, once programmed, will appear in the Locate mode under the Aux [SK] frequency list.

To program the user defined frequencies press the right arrow [SK] to highlight the Auxiliary group of frequencies. Press the up/down arrows [SK]

to highlight the user frequency to program. Press

Enabl/Disabl [SK].

78-8130-6151-8-E

13

Press the left/right arrows [SK] to move the square cursor to a digit. Press Select [SK] to enter the number in the frequency field.

Press OK [5] to save the programmed frequency, or press Exit [SK] to cancel. The frequency will appear in the locate frequency screen as U ###.

Note: To redefine a previously programmed user frequency, highlight the frequency, press enabl/ disabl, select the back arrow with the cursor, and press select to delete the previous entry.

Filtering Power Frequency Interference

MENU [6] + More>>[SK] + Setup [SK] + + More» [SK] + More>>[SK] + Filter [SK]

In order to filter out unwanted power influences while locating with user-defined frequencies, verify the correct frequency is selected for your location (default 50 Hz).

Selecting Locating Audio

MENU [6] + More>>[SK] + Setup [SK] + + More» [SK] + More>>{SK} + Audio Config [SK]

The user can choose the audio response of the receiver when using the Directional Peak mode for path locating. Highlight the audio selection and press OK to save.

14

78-8130-6151-8-E

Buried Cables And Pipes

Transmitter Connections

Perform a battery test. Use one of the following three methods to produce a trace signal on the target pipe or cable.

Direct Connect Method

Plug the direct connect cable into the output jack [T-6] of the transmitter. Connect the black clip to the ground rod. Place the ground rod in the earth perpendicular to the suspected cable/pipe path. If necessary, extend the black lead with the Ground Extension Cable (#9043 available separately).

1.Remove the ground bonding and attach the red clip to the shield of the cable, pipe, or target conductor. (If locating power cables, the red clip can be attached to the transformer cabinet, or the meter box).

2.Turn the transmitter on by pressing Ohms [T-2]. The continuity of the circuit will be measured. The results are displayed [T-4] in ohms and as a tone.

−−If the continuity of the circuit is very good (the reading on the display is less than 3K . and a solid tone from the transmitter is heard) all frequencies can be used to locate. Always use the lowest frequency available. Lower frequencies are less likely to ‘bleed over’ to other cables in the same area, and are very good for tracing over long distances.

−−If the circuit reads more than 3K ., but less than lOK (indicated by a beeping tone from the transmitter) it will be necessary to use a higher frequency than 512 Hz or 577 Hz in order to locate the cable/pipe.

−−If the circuit reads more than lOK ., it will be necessary to use an RF signal such as 33 KHz or 133 KHz.

−−If there is no tone and the transmitter indicates that there is an open circuit (OL in the display) this could be an indication of a poor ground, or an open-ended cable or pipe. Use one of the higher frequencies available, at high level. If it is an open-ended cable or pipe, the receiver's response will decrease suddenly at the site of the clear or severed end.

78-8130-6151-8-E

15

Note: In the ohms mode, the transmitter can detect voltage as well as ohms. If a low voltage is detected, the display will alternate between displaying ohms and volts. When displaying ohms, the flag over the symbol will be visible. When displaying volts, the flag over the ‘V' will be visible. When the voltage magnitude is sufficient to impair the accuracy of the ohms measurement, only voltage will be displayed. If the voltage is AC, a sine wave will be visible on the display [T--4]. If a high AC voltage is detected, a rapid beeping tone will be heard.

3.Press the Trace [T-3] repeatedly until the desired frequency appears on the display.

4.Press Output [T-5] to select high output level for longer tracing distances or deep pipe/cable.

Dyna-Coupler Method

1.Connect the Dyna-Coupler to the transmitter output jack [T-6] using the coupler cable (9011).

2.Clamp the Dyna-Coupler around the cable or pipe, below any bonds, just before it enters the earth. The jaws of the coupler must fully close.

3.Press Trace [T-3] to turn on the transmitter. Press again to select 8 KHz, 33 KHz or 133 KHz.

Note: When using a Dyna-Coupler, always select high output level by pressing the output key [T-5] on the transmitter.