York TM9T User Manual

0 (0)
York TM9T User Manual

TECHNICAL GUIDE

444559-YTG-A-0409

DESCRIPTION

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.

96% TWO STAGE GAS-FIRED RESIDENTIAL

MULTI-POSITION GAS FURNACES MODELS: TM9T

NATURAL GAS

60 - 120 MBH INPUT

EFFICIENCY

RATING

CERTIFIED

ISO 9001

Certified Quality

Management System

These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and venr piping.

FEATURES

Two stage heating operation includes two stage gas valve, two stage inducer operation and 4 speed, direct drive PSC motor blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat.

Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.

Compact, easy to install, ideal height 33" tall cabinet.

Blower-off delay for cooling SEER improvement.

Easy access to controls to connect power/control wiring.

Built-in, high level self diagnostics with fault code display.

Low unit amp requirement for easy replacement application.

All models are convertable to use propane (LP) gas.

Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.

100% shut off main gas valve for extra safety.

24V, 40 VA control transformer and blower relay supplied for add-on cooling.

Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency.

Solid removable bottom panel allows easy conversion.

Airflow leakage less than 1% of nominal airflow at ductblaster conditions.

No knockouts to deal with, making installation easier.

Movable duct connector flanges for application flexibility.

Quiet inducer operation.

Inducer rotates for easy conversion of venting options.

Fully supported blower assembly for easy access and removal of blower.

External air filters used for maximum flexibility in meeting customers IAQ needs.

Due to continuous product improvement,

Insulated blower compartment for thermal and acoustic

specifications are subject to change without notice.

 

performance.

1/4 turn knobs provided for easy independent door removal.

Visit us on the web at www.york.com for the most

Internal condensate trap design (patent pending) provides

up-to-date technical information.

 

condensate management options, easy visual operation

Additional efficiency rating information can

 

check, and is self priming to prevent nuisance problems.

be found at www.gamanet.org.

Protection included from air intake, exhaust vent or

WARRANTY

 

condensate blockage.

Venting applications maybe installed as either 2 pipe sealed

Lifetime limited warranty on both heat exchangers to the origi-

 

combustion or single pipe vent using indoor combustion air.

nal purchaser; a 20-year limited warranty from original installa-

 

 

tion date to subsequent purchaser.

 

 

10-year warranty on the heat exchanger in commercial applica-

 

 

tions.

 

 

5-year limited parts warranty.

 

 

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

444559-YTG-A-0409

LEFT SIDE

 

Combustion Air Inlet

 

Condensate Drain

Gas Pipe

(Downflow)

Entry

Vent Outlet

Electrical

 

Entry

 

Condensate

 

Drain

 

Thermostat

 

Wiring

28.5”

 

29.5”

 

.56”

 

23.8”

3”

 

Vent

 

Outlet

BCombustion

Air Inlet

C

 

.56”

 

 

 

.56”

 

 

 

 

 

 

 

20”

 

 

 

 

 

SUPPLY END

FRONT

 

RIGHT SIDE

 

 

Combustion Air Inlet

 

 

 

 

 

Gas Pipe

Condensate Drain

 

 

Entry

(Downflow)

 

 

Electrical

 

 

 

Entry

Vent Outlet

 

33

Condensate

23”

 

 

Drain

 

 

 

 

 

Thermostat

Optional Return Air

 

 

Wiring

14”

 

Cutout (Either side)

 

 

 

 

 

 

 

 

1”

A

 

1.5”

 

 

 

 

 

 

 

B

 

 

24.25”

 

RETURN END

Cabinet & Duct Dimensions

BTUH (kW)

Nominal

Cabinet

Cabinet Dimensions (Inches)

Approximate

Operating Weights

Input

CFM (m3/min)

Size

 

 

 

 

 

 

 

A

B

C

Lbs

 

 

 

 

 

 

 

 

 

 

TM9T060B12MP11

1200

B

17 1/2

16 3/8

13 1/4

122

TM9T080B12MP11

1200

B

17 1/2

16 3/8

14 3/4

126

TM9T080C16MP11

1600

C

21

19 7/8

16 1/2

136

TM9T100C16MP11

1600

C

21

19 7/8

18 1/4

142

TM9T100C20MP11

2000

C

21

19 7/8

18 1/4

145

TM9T120D20MP11

2000

D

24 1/2

23 3/8

21 3/4

156

Ratings & Physical / Electrical Data

 

Input

Output

 

Total

AFUE

High Fire

Low Fire

Model

High/Low

High/Low

 

Unit

Air Temp. Rise

Air Temp. Rise

 

 

 

MBH

MBH

 

Amps

%

°F

°F

 

 

 

 

 

 

 

 

TM9T060B12MP11

60/39

58/37

 

10

96

35 - 65

35 - 65

TM9T080B12MP11

80/52

77/50

 

10

96

45 - 75

20 - 50

TM9T080C16MP11

80/52

77/50

 

11.5

96

45 - 75

25 - 55

TM9T100C16MP11

100/65

96/62

 

11.5

96

35 - 65

35 - 65

TM9T100C20MP11

100/65

96/62

 

17

96

45 - 75

20 - 50

TM9T120D20MP11

120/78

115/75

 

17

96

45 - 75

35 - 65

 

Max. Outlet

 

Blower

Blower

Max.

Min. Wire Size

Model

Air Temp.

 

Size

Over-current

(awg) @ 75 ft.

 

 

 

 

°F

HP

 

Amps

In.

Protect

One Way

 

 

 

 

 

 

 

 

TM9T060B12MP11

170

0.50

 

7

11 x 8

15

14

TM9T080B12MP11

175

0.50

 

7

11 x 8

15

14

TM9T080C16MP11

175

0.75

 

8.8

11 x 10

15

14

TM9T100C16MP11

175

0.75

 

8.8

11 x 10

15

14

TM9T100C20MP11

175

1.00

 

14.5

11 x 11

20

12

TM9T120D20MP11

180

1.00

 

14.5

11 x 11

20

12

Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.

Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water.

2

Johnson Controls Unitary Products

Loading...