York 112, 114, 110, 218, 216 User Manual

0 (0)
York 112, 114, 110, 218, 216 User Manual

WATER SYSTEMS

Features

 

 

Thermostats

• 6 speed fan

 

 

CSL00 (Built in)

 

 

• Cabinet factory fitted

 

 

CSR00 (Wall mounted)

 

 

Fan speed selector

• Valve factory fitted

 

 

 

 

CML00 (Built in)

 

 

 

 

• Electrical heater factory fitted

 

 

 

 

CMR00 (Wall mounted)

• Thermal or modulating valve

 

 

Thermostat with manual fan speed and S/W

 

 

change over

• Service valve

 

 

 

 

CEL00 (Built in)

 

 

 

 

 

 

 

 

CER00 (Wall mounted)

 

 

 

Thermostat with manual fan speed and automatic

 

 

 

change over

 

 

 

 

 

 

CEL20 (Built in)

 

 

 

CER20 (Wall mounted)

 

 

 

Thermostat with auto. fan speed and automatic

 

 

 

change over

CEL30 (Built in) CER30 (Wall mounted)

Fan Coil Unit Thermostat with auto. fan speed and automatic change over for modulating valve

LOW BODY (2 & 4 pipe system)

A complete range from 0.8 kW up to 2.7 kW

Selection software

Technical features

 

 

 

 

 

 

YLVR - YLIVR

 

 

 

 

 

 

 

 

 

 

 

Model

 

 

 

110

112

114

216

218

 

 

 

 

 

 

 

 

 

Cooling capacity

(1)

2 rows

W

832

1054

1493

2041

2356

 

 

 

 

 

 

 

 

 

Cooling capacity

(1)

3 rows

W

913

1266

1790

2327

2714

 

 

 

 

 

 

 

 

Heating capacity (2)

1 row

W

1167

1691

2319

3029

3552

 

 

 

 

 

 

 

 

 

Pressure drop (3)

 

 

kPa

7

1.7

3.8

9

11.7

 

 

 

 

 

 

 

 

 

Power supply

 

 

V/Ph/Hz

 

 

230 / 1 / 50 + E

 

 

Sound power level (3)

dB(A)

49

50

53

53

55

 

 

 

 

 

 

 

Sound pressure level at 3 m

dB(A)

31

32

35

35

37

 

 

 

 

 

 

 

 

Water connections

 

inch

 

 

1/2 “

 

 

Dimensions indicated next page

(1)Cooling capacities based on 7ºC EWT ∆t 5ºC indoor temperature 27ºC DB / 19ºC WB - (2 pipes - high speed fan)

(2)Heating capacities based on 70ºC EWT ∆t 10ºC indoor temperature 20ºC - (2 pipes - high speed fan)

(3)In cooling mode 2 rows

For other conditions contact York international

Fan Coil Unit LOW BODY

0.8 to 2.7 kW

Compatibility table / Codes

Model

 

110

112

114

216

218

 

 

 

 

 

 

 

With Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

YLVR

2 rows

l

l

l

l

l

 

 

 

 

 

 

 

 

3 rows

l

l

l

l

l

 

 

 

 

 

 

 

 

4 rows

l

l

l

l

l

 

 

 

 

 

 

 

Without Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

YLIVR

2 rows

l

l

l

l

l

 

 

 

 

 

 

 

 

3 rows

l

l

l

l

l

 

 

 

 

 

 

 

 

4 rows

l

l

l

l

l

 

 

 

 

 

 

 

Options (Factory fitted)

 

 

 

 

 

 

Coil and heaters

 

 

 

 

 

 

1 row heating

BA1

l

l

l

l

l

 

 

 

 

 

 

 

Kit electrical heater (with relay and safety switch)

KREL

l

l

l

l

l

 

 

 

 

 

 

 

Built in thermostat

 

 

 

 

 

 

Fan speed selector

CSL00

 

 

l

 

 

 

 

 

 

 

 

 

Thermostat with manual fan speed and S/W change over

CML00

 

 

l

 

 

 

 

 

 

 

 

 

Thermostat with manual fan speed, dead band, automatic

CEL00

 

 

l

 

 

change over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat with automatic fan speed, dead band, automatic

CEL20

 

 

l

 

 

change over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat with automatic fan speed, dead band, automatic

CEL30

 

 

l

 

 

change over for modulating valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parallel connection

 

 

 

 

 

 

 

 

 

 

 

 

 

For ON/OFF valve one/FCU

CBL20

 

 

l

 

 

 

 

 

 

 

 

 

For modulating valve one/FCU

CBL30

 

 

l

 

 

 

 

 

 

 

 

 

3 way valve factory fitted

 

 

 

 

 

 

 

 

 

 

 

 

 

For 2 pipe systems ON/OFF

J3A2 (2p)

 

 

l

 

 

 

 

 

 

 

 

 

For 4 pipe systems ON/OFF

J3A2 (4p)

 

 

l

 

 

3 way modulating valve factory fitted

 

 

 

 

 

 

 

 

 

 

 

 

 

For 2 pipe systems Modulating

J3AM (2p)

 

 

l

 

 

 

 

 

 

 

 

 

For 4 pipe systems Modulating

J3AM (4p)

 

 

l

 

 

 

 

 

 

 

 

 

Shut off valves factory fitted

 

 

 

 

 

 

 

 

 

 

 

 

 

For 2 pipe systems

DT (2p)

 

 

l

 

 

 

 

 

 

 

 

 

For 4 pipe systems

DT (4p)

 

 

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensate pump

PC

 

 

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WS sensor change over for CEL/CER

WS

 

 

l

 

 

 

 

 

 

 

 

 

Minimum temperature thermostat

TM

 

 

l

 

 

Accessories (Supplied loose)

 

 

 

 

 

 

Remote controllers and thermostat (wall mounted)

 

 

 

 

 

 

Fan speed selector

CSR00

 

 

l

 

 

 

 

 

 

 

 

 

Thermostat with manual fan speed and S/W change over

CMR00

 

 

l

 

 

 

 

 

 

 

 

 

Thermostat with manual fan speed, dead band, automatic

CER00

 

 

l

 

 

change over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat with automatic fan speed, dead band, automatic

CER20

 

 

l

 

 

change over

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermostat with automatic fan speed, dead band, automatic

CER30

 

 

l

 

 

change over for modulating valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) for check compatibility with the models of FCU see compatibility table

 

 

 

 

 