WATER SYSTEMS
Features |
|
|
Thermostats |
• 6 speed fan |
|
|
CSL00 (Built in) |
|
|
||
• Cabinet factory fitted |
|
|
CSR00 (Wall mounted) |
|
|
Fan speed selector |
|
• Valve factory fitted |
|
|
|
|
|
CML00 (Built in) |
|
|
|
||
|
|
||
• Electrical heater factory fitted |
|
|
|
|
|
CMR00 (Wall mounted) |
|
• Thermal or modulating valve |
|
|
Thermostat with manual fan speed and S/W |
|
|
change over |
|
• Service valve |
|
|
|
|
|
CEL00 (Built in) |
|
|
|
||
|
|
|
|
|
|
|
CER00 (Wall mounted) |
|
|
|
Thermostat with manual fan speed and automatic |
|
|
|
change over |
|
|
|
|
|
|
|
CEL20 (Built in) |
|
|
|
CER20 (Wall mounted) |
|
|
|
Thermostat with auto. fan speed and automatic |
|
|
|
change over |
CEL30 (Built in) CER30 (Wall mounted)
Fan Coil Unit Thermostat with auto. fan speed and automatic change over for modulating valve
LOW BODY (2 & 4 pipe system)
A complete range from 0.8 kW up to 2.7 kW
Selection software
Technical features
|
|
|
|
|
|
YLVR - YLIVR |
|
|
|
|
|
|
|
|
|
|
|
Model |
|
|
|
110 |
112 |
114 |
216 |
218 |
|
|
|
|
|
|
|
|
|
Cooling capacity |
(1) |
2 rows |
W |
832 |
1054 |
1493 |
2041 |
2356 |
|
|
|
|
|
|
|
|
|
Cooling capacity |
(1) |
3 rows |
W |
913 |
1266 |
1790 |
2327 |
2714 |
|
|
|
|
|
|
|
|
|
Heating capacity (2) |
1 row |
W |
1167 |
1691 |
2319 |
3029 |
3552 |
|
|
|
|
|
|
|
|
|
|
Pressure drop (3) |
|
|
kPa |
7 |
1.7 |
3.8 |
9 |
11.7 |
|
|
|
|
|
|
|
|
|
Power supply |
|
|
V/Ph/Hz |
|
|
230 / 1 / 50 + E |
|
|
Sound power level (3) |
dB(A) |
49 |
50 |
53 |
53 |
55 |
||
|
|
|
|
|
|
|
||
Sound pressure level at 3 m |
dB(A) |
31 |
32 |
35 |
35 |
37 |
||
|
|
|
|
|
|
|
|
|
Water connections |
|
inch |
|
|
1/2 “ |
|
|
Dimensions indicated next page
(1)Cooling capacities based on 7ºC EWT ∆t 5ºC indoor temperature 27ºC DB / 19ºC WB - (2 pipes - high speed fan)
(2)Heating capacities based on 70ºC EWT ∆t 10ºC indoor temperature 20ºC - (2 pipes - high speed fan)
(3)In cooling mode 2 rows
For other conditions contact York international
Fan Coil Unit LOW BODY
0.8 to 2.7 kW
Compatibility table / Codes
Model |
|
110 |
112 |
114 |
216 |
218 |
|
|
|
|
|
|
|
With Cabinet |
|
|
|
|
|
|
|
|
|
|
|
|
|
YLVR |
2 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
|
3 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
|
4 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
Without Cabinet |
|
|
|
|
|
|
|
|
|
|
|
|
|
YLIVR |
2 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
|
3 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
|
4 rows |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
Options (Factory fitted) |
|
|
|
|
|
|
Coil and heaters |
|
|
|
|
|
|
1 row heating |
BA1 |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
Kit electrical heater (with relay and safety switch) |
KREL |
l |
l |
l |
l |
l |
|
|
|
|
|
|
|
Built in thermostat |
|
|
|
|
|
|
Fan speed selector |
CSL00 |
|
|
l |
|
|
|
|
|
|
|
|
|
Thermostat with manual fan speed and S/W change over |
CML00 |
|
|
l |
|
|
|
|
|
|
|
|
|
Thermostat with manual fan speed, dead band, automatic |
CEL00 |
|
|
l |
|
|
change over |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermostat with automatic fan speed, dead band, automatic |
CEL20 |
|
|
l |
|
|
change over |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermostat with automatic fan speed, dead band, automatic |
CEL30 |
|
|
l |
|
|
change over for modulating valve |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Parallel connection |
|
|
|
|
|
|
|
|
|
|
|
|
|
For ON/OFF valve one/FCU |
CBL20 |
|
|
l |
|
|
|
|
|
|
|
|
|
For modulating valve one/FCU |
CBL30 |
|
|
l |
|
|
|
|
|
|
|
|
|
3 way valve factory fitted |
|
|
|
|
|
|
|
|
|
|
|
|
|
For 2 pipe systems ON/OFF |
J3A2 (2p) |
|
|
l |
|
|
|
|
|
|
|
|
|
For 4 pipe systems ON/OFF |
J3A2 (4p) |
|
|
l |
|
|
3 way modulating valve factory fitted |
|
|
|
|
|
|
|
|
|
|
|
|
|
For 2 pipe systems Modulating |
J3AM (2p) |
|
|
l |
|
|
|
|
|
|
|
|
|
For 4 pipe systems Modulating |
J3AM (4p) |
|
|
l |
|
|
|
|
|
|
|
|
|
Shut off valves factory fitted |
|
|
|
|
|
|
|
|
|
|
|
|
|
For 2 pipe systems |
DT (2p) |
|
|
l |
|
|
|
|
|
|
|
|
|
For 4 pipe systems |
DT (4p) |
|
|
l |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Condensate pump |
PC |
|
|
l |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WS sensor change over for CEL/CER |
WS |
|
|
l |
|
|
|
|
|
|
|
|
|
Minimum temperature thermostat |
TM |
|
|
l |
|
|
Accessories (Supplied loose) |
|
|
|
|
|
|
Remote controllers and thermostat (wall mounted) |
|
|
|
|
|
|
Fan speed selector |
CSR00 |
|
|
l |
|
|
|
|
|
|
|
|
|
Thermostat with manual fan speed and S/W change over |
CMR00 |
|
|
l |
|
|
|
|
|
|
|
|
|
Thermostat with manual fan speed, dead band, automatic |
CER00 |
|
|
l |
|
|
change over |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermostat with automatic fan speed, dead band, automatic |
CER20 |
|
|
l |
|
|
change over |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermostat with automatic fan speed, dead band, automatic |
CER30 |
|
|
l |
|
|
change over for modulating valve |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1) for check compatibility with the models of FCU see compatibility table |
|
|
|
|
|
E-COM-H0702