Xantrex Technology XDC 20-600, XDC 150-80, XDC 40-300, XDC 100-120, XDC 10-600 User Manual

...
4 (1)

 

 

 

 

 

 

 

XDC 10-600

XDC 10-1200

 

 

 

 

XDC 20-300

XDC 20-600

 

 

XDC 30-200

XDC 30-400

 

 

XDC 40-150

XDC 40-300

 

 

XDC 60-100

XDC 60-200

 

 

XDC 80-75

XDC 80-150

 

 

XDC 100-60

XDC 100-120

 

 

XDC 150-40

XDC 150-80

 

 

XDC 300-20

XDC 300-40

 

 

XDC 600-10

XDC 600-20

 

 

 

 

 

Operating Manual

XDC 6000 Watt and

12000 Watt Series

Digital Programmable

DC Power Supply

XDC 6000 Watt and 12000

Watt Series Digital

Programmable Power

Supply

Operating Manual

About Xantrex

Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power.

Trademarks

XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply is a trademark of Xantrex International. Xantrex is a registered trademark of Xantrex International.

Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only.

Notice of Copyright

XDC 6kW and 12kW Series Digital Programmable Power Supply Operating Manual © July 2006 Xantrex International. All rights reserved.

Exclusion for Documentation

UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”)

(A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION.

(B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USERS RISK; AND

(C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED XANTREX CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT WWW.XANTREX.COM.

Date and Revision

July 2006 Revision A

Part Number

TM-XDOP-01XN

Contact Information

Telephone:

1 800 670 0707

(toll free in North America)

 

1 360 925 5097

(direct)

Fax:

1 800 994 7828

(toll free in North America)

 

1 360 925 5134

(direct)

Email:

customerservice@xantrex.com

Web:

www.xantrex.com

About This Manual

Purpose

The purpose of this Operating Manual is to provide explanations and procedures for installing, operating, maintaining, and troubleshooting the XDC 6000 Watt and 12000 Watt Series Digital Programmable Power Supply.

Scope

The Manual provides safety guidelines, detailed planning and setup information, procedures for installing the unit, as well as information about operating and troubleshooting the unit.

Audience

This manual is designed for users who understand basic electrical theory, especially as applied to the operation of power supplies. This implies a recognition of constant voltage and constant current operating modes and the control of input and output power, as well as the observance of safe techniques while making connections to the supply and any changes in settings.

iii

Organization

This Manual is organized into five chapters and 5 appendixes:

Chapter 1, “About The XDC Power Supply”, Chapter 1 lists the features of the XDC and shows diagrams of the front and rear panel.

Chapter 2, “Installation” Chapter 2 explains how to mount and wire the XDC and also how to perform basic functional tests.

Chapter 3, “Operation” Chapter 3 explains how to power on and power off the power supply. It provides information about configuring the power supply, and also gives procedures for operating the supply via the front panel controls and menu functions.

Chapter 4, “Remote Operation” Chapter 4 provides an overview of how to use remote analog control, gives information on the setup and use of Multichannel functionality and explains how to send commands to the power supply using the SCPI programming language

Chapter 5, “Current Sharing” Chapter 5 explains what current sharing is, and shows how to configure and operate units in current sharing mode.

Appendix A, “Specifications and Characteristics” Appendix A lists all of the electrical, environmental and mechanical specifications of the XDC.

Appendix B, “Calibration (6000 Watt only)” Appendix B lists the calibration procedures for the 6000 W unit. If you purchased a 12000 Watt unit, please contact your supplier or Xantrex directly (see “Warranty” for contact information).

Appendix C, “SCPI Command Reference” Appendix C provides a summary of the Standard Commands for Programmable Instruments (SCPI) that are supported by the this Programmable Power Supply.

Appendix D, “Error Messages” Appendix D lists all the error codes and their meanings.

Appendix E, “GPIB” Appendix E describes the General Purpose Interface Bus (GPIB) commands and lines supported by this model.

“Warranty and Product Information” This section explains the warranty and provides information on returning your unit for service.

iv

TM-XDOP-01XN

Conventions Used

The following conventions are used in this guide.

WARNING

Warnings identify conditions that could result in personal injury or loss of life.

CAUTION

Cautions identify conditions or practices that could result in damage to the unit or other equipment.

Important: These notes describe things which are important for you to know, but not as serious as a caution or warning.

Related Information

You can find more information about Xantrex Technology Inc. as well as its products and services at www.xantrex.com

TM-XDOP-01XN

v

vi

Important Safety Instructions

WARNING: High energy and high voltage

Exercise caution when using and calibrating a power supply. High energy levels can be stored at the output voltage terminals on a power supply in normal operation. In addition, potentially lethal voltages exist in the power circuit and on the output and sense connectors of a power supply with a rated output greater than 40 V. Filter capacitors store potentially dangerous energy for some time after power is removed.

WARNING: Limitations on use

The XDC is not intended for use in connection with life support systems or other medical equipment or devices.

CAUTION

Operate the power supply in an environment free of flammable gases or fumes. To ensure that the power supply’s safety features are not compromised, use the power supply as specified in this manual and do not substitute parts or make any unauthorized modifications. Contact the service technician for service and repair help. Repairs must be made by experienced service technicians only.

CAUTION: For use as a battery charger

When you are using any of these power supplies for battery charging applications, it is essential to provide an appropriately sized fuse or circuit breaker in series between the power supply output and the battery.

Installation of a protector (fuse or DC circuit breaker) rated for about 115% of the maximum current rating of the power supply and designed specifically to interrupt the DC voltage of the battery, will provide adequate reverse polarity current protection. Where several power supplies are in parallel, it is best to fuse each one, rather than one large fuse for all.

vii

Approvals

Units bearing the c(CSA)us mark are certified by CSA to the following: CAN/CSA C22.2 No. 1010.1-92 and CAN/CSA C22.2 No. 1010.1B-97 and to ANSI/UL 61010B-1

Units bearing the CE mark meet the requirements of:

EMC Directive (standards EN50081-2 and EN50082-1) and Low Voltage Directive (safety standard IEC 61010:1990 +A.1:1992 +A.2:1995).

FCC part 15 Class A limits for radio frequency emissions.

Canadian EMC standard ICES-001, Class A limits.

viii

TM-XDOP-01XN

IEC Symbols Used in This Manual

Earth (Ground) Terminal

Protective Conductor Terminal

On (Supply)

Off (Supply)

Warning (Shock Hazard)

Caution (Check manual for specific information.)

TM-XDOP-01XN

ix

x

Contents

Important Safety Instructions

Approvals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - viii IEC Symbols Used in This Manual - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ix

1 About The XDC Power Supply

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2

Features - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2

Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–3

Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–9

Status Annunciators - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–9

Rear Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–11

Overview of Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–12

Power ON - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–12

Control Modes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1–12

2 Installation

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Basic Setup Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Inspection, Cleaning, and Packaging- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Initial Inspection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Maintenance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–3 Packaging for Shipping or Storage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–3 Location, Mounting, and Ventilation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–4 Rack Mounting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–4 Ventilation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–6 AC Input Power - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–7 AC Input Connector - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–7 AC Input Wire - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–8 AC Wire Input Connection for 6000 W - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–9 AC Wire Input Connection for 12000 W - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–11 Basic Checks or Self-Tests - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–13 Equipment Required - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–13 Display Test - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–13 Power ON Check - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–13 Voltage Mode Operation Check - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -2–14

TM-XDOP-01XN

xi

Current Mode Operation Check - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–15 Load Wiring- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–16 Current Carrying Capacity - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–16 Load Wiring Length for Operation with Sense Lines - - - - - - - - - - - - - - - - - - - - - - - - 2–16 Noise and Impedance Effects - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–17 Load Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–18 Wire Size - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–18 Isolation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–18 Single Load - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–18 Multiple Loads - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–19 Output Strain Relief/Cover - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–20 Remote Sensing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–24

3 Operation

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–2 Powering ON the Power Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–2 Powering OFF the Power Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–2 Power Supply Operating States - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–3 Power Supply Regulation Modes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–4 Remote Control Modes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–5 Front Panel Controls - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–5 Function Keys - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–5 Menu Navigation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–6 Top Level Menu Items - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–6 Control Knobs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–7 Power Supply Operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–8 Set Voltage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–8 Set Current - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–8 Set Power - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–9 Turn Output On or Off - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -3–9 Set Output Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–10 Set Shutdown Recovery for AC Off and OTP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–15 Respond to Alarms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–16 Shutdown vs Protection Alarm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–17 Set Up Remote Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–18 Toggle Local/Remote - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–18 Select Remote Control Source - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–19 Configure Remote Control Source - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–20 Store User Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–21 Change Stored Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–22

xii

TM-XDOP-01XN

Recall Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–23

Read Error Messages - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–26

Configure User Lines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–27

Configure Power ON Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–29

Factory Preset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–30

User Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–31

Last Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–32

Auto-Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–32

Program Auto Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–33

Programming a Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–33

Deleting a Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–36

Editing a Sequence Step - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–37

Inserting a Sequence Step - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–38

Deleting a Sequence Step - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–39

Editing Repeat Times of a Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–40

Editing Trigger Source of a Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–41

Using Auto Sequencing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–42

Configure Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–43

Lock Out Control Knobs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–44

Set V, I, and P Limits - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–45

Slew Rate - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–49

View Model Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–50

Default Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–51

View Power Output - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–51

Monitor Status - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3–51

4 Remote Operation

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–2 Making Connections for Remote Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–3 Remote Analog Operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–4 Analog Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–4 Pin Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–6 Remote Interlock Using a Contact Closure - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–7 Configure Analog Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–8 Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–8 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–9 Using Remote Analog Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–10

Multichannel Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–11 Multichannel Connections - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–11 CANbus - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -4–11

TM-XDOP-01XN

xiii

Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–12 Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–12 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–12 Setup - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–13 Using Multichannel Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–14 Multichannel Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–15 Multichannel Broadcast Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–15 Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–15

RS-232 Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–16 RS-232 Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–16 Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–17 Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–17 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–18 Using RS-232 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–18

GPIB Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–19 GPIB Connection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–19 Configuration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–20 Front panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–20 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–21 Using GPIB - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–21

SCPI Commands for Digital Interfaces - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–22 Set Up Power ON Defaults - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–22 Factory Preset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–22 Last Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–23 User Setting - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–23 Auto Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–23 Power On Output State - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–24 Reset - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–24 Store User Settings - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–25 Change Remote/Local Control of Power Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–26 Enable Output - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–26 Program V,I,P - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–27 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–27 Configure V, I, P Protection Limits - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–29 Over-Voltage Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–29 Under-Voltage Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–29 Over-Current Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–30 Under-Current Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–30 Over-Power Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–31 Under-Power Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–31 Configure Other Protection Mechanisms - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–32

xiv

TM-XDOP-01XN

Fold Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–32

Over Temperature Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–32

AC Off Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–33

Clear Protection Event - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–33

View Power Supply Output - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–33

Configure Auxiliary Status Lines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–34

Read Error Messages - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–35

Triggering Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–36

Auto Sequencing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–37

Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–37

Editing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–37

Programming Sequences - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–38

Select Sequence to Program - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–38

Editing the Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–38

Setting Sequence Repetitions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–38

Selecting a Trigger Source - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–39

Editing Step Parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–39

Deleting Sequences - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–39

Auto Sequence Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–40

Select Sequence to Run - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–40

Operation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–40

Slew Rate - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–41

Identification Query - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–42

Option Identification Query - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–42

SCPI Version Query - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–42

Status Registers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–43

OPERation Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–44

REGulating Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–47

SHUTdown Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–47

Protection SHUTdown Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–48

Remote CONtrol Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–49

Current SHare Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–50

QUEStionable Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–50

VOLTage Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–53

CURRent Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–53

POWer Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–53

TEMPerature Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–54

Standard Event Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–54

Status Byte - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–55

Error/Event Queue (ERR) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–56

Questionable Status Register Summary (QSR) - - - - - - - - - - - - - - - - - - - - - - - - -

4–56

TM-XDOP-01XN

xv

Message Available (MAV) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–56

Standard Event Status Summary (ESB) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–56

Master Summary Status (MSS) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–56

Request Service (RQS) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–57

Operation Status Register Summary (OSR) - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–57

Status Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–58

SCPI Status Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–58

IEEE 488.2 Status and Event Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–59

Operation Status Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–62

Regulating Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–63

Shutdown Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–64

Protection Shutdown Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - 4–65

Remote Control Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–65

Current Share Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–67

Questionable Status Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–68

Voltage Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–69

Current Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–70

Power Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–71

Temperature Sub-Register Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–72

5 Current Sharing

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5–2 Setting up Current Sharing - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5–3 Operation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5–5 Errors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5–6 CANbus Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -5–6

A Specifications and Characteristics

Electrical Specifications—Summary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–2

AC Line Input Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–6

AC Line Input Voltage Operating Ranges - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–6

Output Performance Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–7

Environmental Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–12

Thermal Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–12

Humidity Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–12

International Approvals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–13

Mechanical Specification - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–14

Weight - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–14

Size - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - A–14

xvi

TM-XDOP-01XN

B Calibration (6000 Watt only)

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–2 Entering Calibration Mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–3 Front Panel - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–3 SCPI - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–4 Security code - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–5 Setup and Equipment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–6 Front Panel Calibration Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–7 Output Voltage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–7 Output Current - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–7 Analog Programming Interface 0-5V Range - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–8 Analog Programming Interface Voltage Programming Calibration - - - - - - - - - - - - B–8 Analog Programming Interface Voltage Readback Calibration - - - - - - - - - - - - - - - B–9 Analog Programming Interface Current Programming Calibration - - - - - - - - - - - - B–9 Analog Programming Interface Current Readback Calibration - - - - - - - - - - - - - - B–10 Analog Programming Interface 0-10V Range - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–10 Remote Interface Calibration Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–11 Output Voltage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–11 Output Current - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–11 Analog Programming Interface 0-5V Range - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–12 Analog Programming Interface Voltage Programming Calibration - - - - - - - - - - - B–12 Analog Programming Interface Voltage Readback Calibration - - - - - - - - - - - - - - B–13 Analog Programming Interface Current Programming Calibration - - - - - - - - - - - B–13 Analog Programming Interface Current Readback Calibration - - - - - - - - - - - - - - B–14 Analog Programming Interface 0-10V Range - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–14 Exit calibration mode - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–15 Restore Factory Calibration- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - B–15

C SCPI Command Reference

Codes and Standards - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–2

IEEE 488.2 Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–2

SCPI Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–2

IEEE-488.2/SCPI Syntax and Style - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–3

Parameters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–3

Units of Measure and Multipliers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–3

SCPI Command Hierarchy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–4

Using SCPI Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–5

Using Minimum and Maximum - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–6

Using Queries - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–6

TM-XDOP-01XN

xvii

Terminating Characters - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–7

Common Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–7

Parameter Types - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–8

SCPI Command Summary - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–9

Notations Used in the Tables - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–9

Expressions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -C–33

D Error Messages

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–2 Command Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–2 Execution Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–3 Device-Specific Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–5 Query Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 User Request Event - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 Operation Complete Event - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 Front Panel Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 CPU Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 Analog Programming Interface Error codes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 Auto Sequencing Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 CANbus Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–8 Multichannel Error Codes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–8 Current Share Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–9

E GPIB

Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Codes and Standards - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Message Terminators- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Address Range - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Primary Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Secondary Address - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Service Request and Polling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–2

Protocol Specifications- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–3

Multiline Control Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–3

Interface Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–3

Electrical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–4

Driver Requirements - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–4

xviii

TM-XDOP-01XN

Mechanical Specifications- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–4

Performance Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–4

Warranty and Product Information - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WA–1

Index - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -IX–1

TM-XDOP-01XN

xix

xx

Figures

Figure 1-1

Front Panel (6000 Watt) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

- 1–3

Figure 1-2

Front Panel (12000 Watt) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

- 1–4

Figure 1-3

Keypad - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1–5

Figure 1-4

Front Panel Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1–9

Figure 1-5

Front Panel Display, Status Annunciators - - - - - - - - - - - - - - - - - - - - - - - - -

1–9

Figure 1-6

Rear Panel (6000 Watt) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1–11

Figure 2-1

Typical Box Label for Storage - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2–3

Figure 2-2

Unpacking the Power Supply- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2–5

Figure 2-3

Mounting the Power Supply in the Rack With Support Rails - - - - - - - - - - - -

2–6

Figure 2-4

AC Input Connector for 6000 Watt units - - - - - - - - - - - - - - - - - - - - - - - - - -

2–7

Figure 2-5

Attaching the AC Input Wires for 6000 Watt units - - - - - - - - - - - - - - - - - -

2–10

Figure 2-6

Attaching the AC Input Wires for 12000 Watt units - - - - - - - - - - - - - - - - -

2–12

Figure 2-7

Fastening the Output Wires (6000 Watt) - - - - - - - - - - - - - - - - - - - - - - - - -

2–19

Figure 2-8

Output Bus Bar Cover for 6000 Watt units - - - - - - - - - - - - - - - - - - - - - - -

2–20

Figure 2-9

Output for 12000 Watt units - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2–21

Figure 2-10

Output Cover with Strain Relief for 6000 Watt units - - - - - - - - - - - - - - - - -

2–22

Figure 2-11

Output for 12000 Watt units - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2–23

Figure 4-1

View of Remote Interface Connections - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–3

Figure 4-2

Schematic For User Line Interface - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–6

Figure 4-3

Connections for Multichannel Operation - - - - - - - - - - - - - - - - - - - - - - - - -

4–13

Figure 4-4

Operation Status Registers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–45

Figure 4-5

Questionable Status Registers - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

4–51

Figure 4-6

IEEE 488.2 Status Register and Status Byte - - - - - - - - - - - - - - - - - - - - - - -

4–54

Figure 5-1

Connections for Current Share Operation - - - - - - - - - - - - - - - - - - - - - - - - -

5–2

Figure A-1

Power Supply Dimensions (6000 Watt unit)- - - - - - - - - - - - - - - - - - - - - - -

A–14

Figure A-2

Power Supply Dimensions (12000 Watt unit)- - - - - - - - - - - - - - - - - - - - - -

A–15

TM-XDOP-01XN

xxi

xxii

Tables

Table 1-1 Item Descriptions for Figure 1-1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–3 Table 1-2 Item Descriptions for Figure 1-2 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–4 Table 1-3 Item Descriptions for Figure 1-3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–5 Table 1-4 Front Panel Functions- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–7 Table 1-5 Item Descriptions for Figure 1-4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–9 Table 1-6 Item Descriptions for Figure 1-5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–10 Table 1-7 Item Descriptions for Figure 1-6 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–11 Table 2-1 Basic Setup Procedure - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2–2 Table 2-2 AC Wire Specification for 6000 Watt Units - - - - - - - - - - - - - - - - - - - - - - - - 2–8 Table 2-3 AC Wire Specification for 12000 Watt Units - - - - - - - - - - - - - - - - - - - - - - - 2–8 Table 2-4 Current Carrying Capacity for Load Wiring - - - - - - - - - - - - - - - - - - - - - - - 2–16 Table 3-1 Settings Affected by Recall - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–25 Table 3-2 To Program a Sequence - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3–33 Table 4-1 User Line Pins- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–6 Table 4-2 Analog Programming Pins - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–7 Table 4-3 Analog Pin Connections for Power Loop Back- - - - - - - - - - - - - - - - - - - - - - 4–7 Table 4-4 Analog Pin Connections with a Contact Closure - - - - - - - - - - - - - - - - - - - - - 4–7 Table 4-5 CANbus Pins - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–11 Table 4-6 RS-232 Pins - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–16 Table 4-7 GPIB Pins - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–19 Table 4-8 Features Affected by Reset (*RST) Command - - - - - - - - - - - - - - - - - - - - - 4–24 Table 4-9 OPERation Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–46 Table 4-10 REGulating Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–47 Table 4-11 SHUTdown Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–47 Table 4-12 Protection SHUTdown Sub-Register- - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–48 Table 4-13 Remote CONtrol Sub-Register- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–49 Table 4-14 Current SHare Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–50 Table 4-15 QUEStionable Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–52 Table 4-16 VOLTage Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–53 Table 4-17 CURRent Sub-Register- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–53 Table 4-18 POWer Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–53 Table 4-19 TEMPerature Sub-Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–54 Table 4-20 Standard Event Status Register - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–55 Table 4-21 Status Byte Summary Register- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4–56 Table 4-22 Preset Values of User Configurable Registers- - - - - - - - - - - - - - - - - - - - - - 4–58

TM-XDOP-01XN

xxiii

Table A-1 Specifications for 6000 Watt units (10V to 60V Models) - - - - - - - - - - - - - - - A–2 Table A-2 Specifications for 6000 Watt units (80V to 600V Models) - - - - - - - - - - - - - - A–3 Table A-3 Specifications for 12000 Watt units (10V to 60V Models) - - - - - - - - - - - - - - A–4 Table A-4 Specifications for 12000 Watt units (80V to 600V Models) - - - - - - - - - - - - - A–5 Table C-1 IEEE 488.2 Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–10 Table C-2 Readback Commands- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–12 Table C-3 Commands for Output Control - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–13 Table C-4 Commands for Current Share - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–15 Table C-5 Commands for Calibration - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–16 Table C-6 Command to Clear all Protection Mechanisms - - - - - - - - - - - - - - - - - - - - - C–17 Table C-7 Commands for Fold Protection - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–18 Table C-8 Commands for Triggering- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–18 Table C-9 System Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–19 Table C-10 Status Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–20 Table C-11 Protection Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–27 Table C-12 User Lines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–27 Table C-13 Output State - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–28 Table C-14 Auto Sequence Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–29 Table C-15 Legacy Commands - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–32 Table C-16 Expressions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - C–33 Table D-1 Command Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–2 Table D-2 Execution Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–3 Table D-3 Device-Specific Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–5 Table D-4 Query Error List - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 Table D-5 User Request Event - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 Table D-6 Operation Complete Event - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–6 Table D-7 Front Panel Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 Table D-8 CPU Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 Table D-9 Analog Programming Interface Error code - - - - - - - - - - - - - - - - - - - - - - - - D–7 Table D-10 Auto Sequencing Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–7 Table D-11 CANbus Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–8 Table D-12 Multichannel Error Codes- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–8 Table D-13 Current Share Error Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D–9 Table E-1 Multiline Control Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–3 Table E-2 Interface Functions - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–3 Table E-3 Driver Types for Interface Lines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - E–4

xxiv

TM-XDOP-01XN

1

About The XDC Power

Supply

Chapter 1 lists the features of the XDC and shows diagrams of the front and rear panel.

About The XDC Power Supply

Overview

The XDC Series of digital, programmable DC power supplies is designed for use in OEM, ATE, burn-in, magnet charging, and other high power systems for a broad range of applications. The XDC uses our newly developed digital technology which, combined with “Soft Switching,” provides superior performance and a high level of user control through both front panel and remote interfaces.

Features

Digital processing for highly accurate control

Ten, 99-step auto sequences for easy bench-top programming of complex test routines

Ten stored settings

Zero voltage (soft) switching for low noise output, improved efficiency and higher reliability

Active Power Factor Correction (PFC) for lower input current draw and lower current harmonic generation

Remote voltage sense with 5V line drop compensation

Automatic Voltage/Current mode crossover

Constant power mode

Seven load protection mechanisms

Alarms and messages for overand under-programmed trip points

Auxiliary status lines for monitoring power supply conditions

Remote interlock and trigger ports

Selectable standby, last setting, programmed sequence and other power-on defaults

Active current sharing with parallel connected units for higher power requirements. (These features are available when the power supply is equipped with the optional GPIB/CANbus interface card.)

Standard RS-232 remote control interface and optional GPIB (IEEE 488.2) port

CANbus communications link for multichannel addressing, and master/slave current sharing*

Extensive SCPI command set

Keypad, knobs, and arrow keys for fast and tactile front panel operation

Bright vacuum fluorescent display with annunciators to indicate complete supply status at a glance

Front panel, software-based calibration

Fully isolated analog programming and readback capabilities

CE Mark, CSA Certified, FCC Compliance

1–2

TM-XDOP-01XN

Front Panel

Front Panel

1

3

4

5

6

7

8

1

2

 

 

 

 

 

 

2

Figure 1-1

Front Panel (6000 Watt)

 

 

 

 

 

 

Table 1-1

Item Descriptions for Figure 1-1

 

 

 

 

Item

Description

 

 

 

 

1

Rack mount brackets

 

 

2

Handles

 

 

3

On/Off Switch

 

 

4

Air intake vents

 

 

5

Front panel display (vacuum fluorescent display). See Figure 1-4

 

for details.

 

 

6

Voltage knob

 

 

7

Current knob

 

 

8

Keypad. (See Figure 1-3 for details.)

TM-XDOP-01XN

1–3

Xantrex Technology XDC 20-600, XDC 150-80, XDC 40-300, XDC 100-120, XDC 10-600 User Manual

About The XDC Power Supply

1

3

4

5

6

7

8

1

2

 

 

 

 

 

 

2

Figure 1-2

Front Panel (12000 Watt)

 

 

 

 

 

 

Table 1-2

Item Descriptions for Figure 1-2

 

 

 

 

Item

Description

 

 

 

 

1

Rack mount brackets

 

 

2

Handles

 

 

3

On/Off Switch

 

 

4

Air intake vents

 

 

5

Front panel display (vacuum fluorescent display). See Figure 1-4

 

for details.

 

 

6

Voltage knob

 

 

7

Current knob

 

 

8

Keypad. (See Figure 1-3 for details.)

1–4

TM-XDOP-01XN