Important Safety Information

DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY.

DO NOT USE A GROUND FAULT INTERRUPTER (GFI).

A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.

-1 -

TABLE OF CONTENTS

Feature Description…………………………….……………..3

Installation Instruction………………………………………..5

Temperature Control & Humidity Adjustment………….8

Care Guide……………………………………………………11

Troubleshooting……………………………………………..12

Wiring Diagram……………………………………….………15

Customer Support……………………………………………16

Warranty……………………………………………………….17

- 2 -

Feature Description

VINO1500CD, CTED and VINO2500CD, CTED cooling units are designed and used to provide a subtle temperature between 50~65 °F for suitable space at a normal environment.

The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid.

These temperatures and humilities are optimized for long term storage of wine.

Bottom cold-air supply is optimized for use in the wine cabinets.

Multiple options for top and rear hot air exhaust

Self-contained ready for use and easy for installation

Fig. 1.1 FEATURES

- 3 -

Fig. 1.2 DIMENSIONS (in)

The dimension and capacity are specified as follows:

Model

Exhaust

Cooling

Bottle

Electrical

Weight

Capacity, CFM

Capacity

 

 

55°F/ 75°F

55°F/ 75°F

 

 

1500cd

Rear Exhaust

1500 Btu/h,

150

800

115V/60Hz

50 lb

120 CFM

cu ft

bottles

4A

 

 

 

1500cted

Top Exhaust

1500 Btu/h,

150

800

115V/60Hz

50 lb

120 CFM

cu ft

bottles

4A

 

 

 

2500cd

Rear Exhaust

2500 Btu/h,

250

1200

115V/60Hz

55 lb

180 CFM

cu ft

bottles

5A

 

 

 

2500cted

Top Exhaust

2500 Btu/h,

250

1200

115V/60Hz

55 lb

180 CFM

cu ft

bottles

5A

 

 

 

See the voltage, frequency and current specified on the label at the cooling unit.

- 4 -

Installation Instruction

1.Cabinet Location

Place the wine cabinet in a properly ventilated location. Otherwise, heat exhausted by the cooling unit will build up and it will not operate properly.

The exhaust area must not be a closed space and must be ventilated. The ambient temperatures shall not be higher than 90 °F or lower than 50 °F.

1) Rear Exhaust Location

Leave min 6 “clearance from the rear to the wall.

Leave min 12” clearance from the top to the ceiling.

Leave min 6” clearance from the left and right sides.

2) Front Exhaust Location

• Leave min 6” clearance from the front if left and right sides unobstructed.

• Or, leave min 36” clearance from the front if left and right sides obstructed 3) Top Exhaust Location

Leave min 12” from the top to the ceiling.

Leave min 2 “clearance from the rear to the wall.

Leave min 2” clearance from the left and right sides.

4) Side Exhaust Location

Leave min 6 “clearance from the left or right side to the wall.

Leave min 12” clearance from the top to the ceiling.

2.Installation