Vermont Casting LHECDV20, LHERDV30, LHECDV30, LHERDV20 User Manual

5 (2)

INSTALLER/CONSUMER SAFETY INFORMATION

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

WARNING!

IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from your neighbor’s phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier call the fire department.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

Direct Vent Insert Models: LHERDV20

LHERDV30

LHECDV20

LHECDV30

Homeowner's Installation and

Operating Manual

 

S

 

E IG

N

D

 

CERTIFIED

C

D

E

 

RTIFIE

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

10004894 1/07 Rev. 4

LHEDV Series Direct Vent Insert

Table of Contents

PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THIS APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace insert.

IMPORTANT - Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the manufacturers' warranty.

Installation Instruction

 

Important Curing/Burning Instructions................................................................................................

3

Locating Your Fireplace Insert............................................................................................................

3

Insert Applications ..............................................................................................................................

3

Fireplace & Trim Dimensions .............................................................................................................

4

Mantels...............................................................................................................................................

5

Framing & Finishing............................................................................................................................

5

Zero Clearance Applications...............................................................................................................

5

Gas Specifications..............................................................................................................................

6

Gas Inlet & Manifold Pressures..........................................................................................................

6

High Elevations...................................................................................................................................

6

Preparation.........................................................................................................................................

6

Gas Line Installation...........................................................................................................................

6

Gas Supply Pressures........................................................................................................................

7

Fan Kit ................................................................................................................................................

7

Fan Removal Instructions...................................................................................................................

7

Installation of Trim Switch for RN/RP Gas Valves ..............................................................................

7

Venting and Installation ......................................................................................................................

8

Liner Installation .................................................................................................................................

9

Round Vent Termination Installation .................................................................................................

11

Ceramic Refractory Installation ........................................................................................................

11

Venting Components ........................................................................................................................

12

Operating Instructions

 

General Glass Information...............................................................................................................

13

Louvre Removal ...............................................................................................................................

13

Glass Cleaning .................................................................................................................................

13

Glass Frame Removal......................................................................................................................

13

Log & Burner Lava Rock Installation ................................................................................................

13

Large Lava Rock Placement ............................................................................................................

14

Flame Adjustment ............................................................................................................................

14

Flame Characteristics.......................................................................................................................

14

First Firing.........................................................................................................................................

15

Lighting & Operating Instructions ....................................................................................................

16

Troubleshooting Gas Control (820 Millivolt Gas Valve) ....................................................................

17

Troubleshooting Gas Control (Honeywell).......................................................................................

18

Instructions for RF Comfort Control Valve ........................................................................................

19

Maintenance

 

Cleaning the Standing Pilot Control System.....................................................................................

23

Trim Cleaning ...................................................................................................................................

23

Replacement Parts ..............................................................................................................................................

24

Optional Accessories

 

Remote Controls...............................................................................................................................

27

Zero Clearance Kit............................................................................................................................

27

Trim Options .....................................................................................................................................

27

Warranty ...............................................................................................................................................................

28

Energuide..............................................................................................................................................................

30

2

10004894

LHEDV Series Direct Vent Insert

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSAB149.1 Installation codes for Gas Burning Appliances and Equipment. FOR U.S. Installations follow local codes and/or the current National Fuel Gas Code ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fittings and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING:

1.This appliance gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.

3.Children should be carefully supervised when they are in the same room as your appliance.

4.Under no circumstances should this appliance be modified. Parts removed for servicing should be replaced prior to operating this appliance again.

5.Installation and any repairs to this appliance should be carried out by a qualified service person. A professional service person should be contacted to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually. More frequent cleaning may be required due to excess lint and dust from carpeting, bedding material, etc.

6.Control compartments, burners and air passages in this appliance should be kept clean and free of dust and lint. Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit.

7.The venting system (chimney) of this appliance should be checked at least once a year and if needed your venting system should be cleaned.

8.Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids. This appliance should not be used as a drying rack for clothing, nor should Christmas stockings or decorations be hung in the area of it.

9.Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.

10.Whether the zero clearance kit is installed directly on carpeting, vinyl tile or any combustible material other than wood, this heater must be installed on a metal or wood panel extending the full width and depth of the heater. The insert can not be installed directly onto or into combustibles.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.

California Health & Safety Code Sec. 25249.6

WARNING: Check with your electronics manufacturer before installing a television or other electronic device above this fireplace.

IMPORTANT:

PLEASE READ THE FOLLOWING CAREFULLY

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated - open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time.

Locating Your Gas Fireplace Insert

with Zero Clearance Kit

X E A B

C

X D

X F

FP1249a

Fig. 1 Locating unit with zero clearance kit.

A)

Flat on wall

B)

Cross corner

C)

Island

D)

*Room divider

E)

*Flat on wall corner

F)

Chase installation

NOTE: (Fig. 1)

* When you install your fireplace in (D) Room divider or (E) Flat on wall corner positions, a minimum of 6 (X) inches (153mm) clearance must be maintained from the perpendicular wall and the outer edge of the trim.

Insert Applications

Before installing the gas fireplace insert, consideration must be given to the functioning needs of the fireplace. The size of the fireplace cavity (min. 25¹⁄ "W x 17¹⁄ "H x 13¹⁄ " D (641 x 438 x 343 mm) for the LHECDV20 and LHERDV20, 28³⁄ "W x 21"H x 15¹⁄ "D (730 x 533 x 394 mm) for LHECDV30 and LHERDV30), the design of the chimney for effective venting

should be determined. The availability of the gas supply as well as electricity for the insert fan must be confirmed.

Your Direct Vent Insert unit is designed to be vented vertically with a minimum height of

12' (4 m).

10004894

3

LHEDV Series Direct Vent Insert

 

 

 

 

 

 

 

 

Fireplace & Trim Dimensions

 

 

 

B

 

3" (75mm)

D

 

 

 

 

 

 

 

Dia.

 

 

 

 

 

 

 

 

A

 

G

A

I

J

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

 

 

C

 

 

B

 

K

 

 

 

 

 

 

 

 

 

 

 

 

 

Zero Clearance Kit

 

 

 

 

 

 

Insulation

M

 

 

 

 

 

 

 

 

 

 

P

 

 

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

Q V

T

 

 

E

 

O

 

 

 

 

S

 

F

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

Minimum Fireplace

 

 

 

 

 

N

 

 

Insert Opening

1"

 

 

 

 

 

 

 

 

 

 

 

 

1 = LHESSB

Air Circulating Channel

Gas Inlet Knockout

 

 

 

 

 

 

 

 

 

2 = LHESLB/LHEABSL/LHESLGA

Q - Fireplace opening height

U - Firebox depth at insert back height (V)

3 = LHECSLB/LHECSLMB/LHECSLSA

R - Fireplace opening width

V - Insert back height

 

 

4 = LHEACNSS

 

S - Depth of insert

 

NOTE: LHESLGA is only available for

5 = LHETCK

 

T - Firebox width at insert depth(S)

Model LHEC30 and LHER30

 

 

 

 

LHECDV20

LHERDV20

LHECDV30

LHERDV30

 

 

 

T

A-1

20 ⁄ "

(530 mm)

20 ⁄ "

(530 mm)

26³⁄ "

(680 mm)

26³⁄ "

(680 mm)

 

 

 

B-1

30³⁄ "

(781 mm)

30³⁄ "

(781 mm)

38¹⁄ "

(972 mm)

38¹⁄ "

(972 mm)

 

 

 

R

 

 

A-2

24¹⁄ "

(616 mm)

24¹⁄ "

(616 mm)

28³⁄ "

(716 mm)

28³⁄ "

(716 mm)

 

 

 

I

 

 

B-2

37¹⁄ "

(952 mm)

37¹⁄ "

(952 mm)

41"

(1042 mm)

41"

(1042 mm)

 

 

 

M

 

 

A-3

24¹⁄ "

(616 mm)

24¹⁄ "

(616 mm)

28¹⁄ "

(717 mm)

28¹⁄ "

(717 mm)

 

 

 

 

 

 

 

B-3

38¹⁄ "

(968 mm)

38¹⁄ "

(968 mm)

41¹¹⁄ "

(1059 mm)

41¹¹⁄ "

(1059 mm)

 

 

 

 

A-4

20³⁄ "

(527 mm)

20³⁄ "

(527 mm)

24³⁄ "

(629 mm

24³⁄ "

(629 mm)

 

 

 

 

B-4

30 ⁄ "

(784 mm)

30 ⁄ "

(784 mm)

34 ⁄ "

(875 mm)

34 ⁄ "

(875 mm)

 

 

 

 

A-5

28"

(711 mm)

28"

(711 mm)

32¹⁄ "

(819 mm)

32¹⁄ "

(819 mm)

 

 

 

 

B-5

45"

(1143 mm)

45"

(1143 mm)

49"

(1245 mm)

49"

(1245 mm)

 

 

 

C

25 ⁄ "

(651 mm)

25 ⁄ "

(651 mm)

29³⁄ "

(741 mm)

29³⁄ "

(741 mm)

 

 

 

F

D

17"

(432 mm)

17"

(432 mm)

17 ⁄ "

(448 mm)

16³⁄ "

(425 mm)

 

 

 

I

E

35"

(889 mm)

35"

(889 mm)

35"

(889 mm)

35"

(889 mm)

 

 

 

R

F

26 ⁄ "

(676 mm)

26 ⁄ "

(676 mm)

26 ⁄ "

(676 mm)

26 ⁄ "

(676 mm)

 

 

 

E

G

13¹⁄ "

(343 mm)

13¹⁄ " (343mm)

15¹⁄ "

(394 mm)

16¹⁄ "

(419 mm)

 

 

 

P

H

17"

(432 mm)

17"

(432 mm)

20¹⁄ "

(521 mm)

20¹⁄ "

(521 mm)

 

 

 

L

I

18"

(457 mm)

18"

(457 mm)

21¹⁄ "

(546 mm)

21¹⁄ "

(546 mm)

 

 

 

A

J

19¹⁄ "

(486 mm)

19¹⁄ "

(486 mm)

22 ⁄ "

(575 mm)

22 ⁄ "

(575 mm)

 

 

 

C

K

15"

(381 mm)

15"

(381 mm)

17"

(432 mm)

18"

(457 mm)

 

 

 

E

L

10³⁄ " (264mm)

10³⁄ "

(273 mm)

11³⁄ "

(298 mm)

12³⁄ "

(324 mm)

 

 

 

 

M

8¹⁄ "

(216 mm)

8¹⁄ "

(216 mm)

8¹⁄ "

(216 mm)

8¹⁄ "

(216 mm)

 

 

 

 

N

37¹⁄ " (946mm)

37¹⁄ "

(946 mm)

37¹⁄ "

(946 mm)

37¹⁄ "

(946 mm)

 

 

 

 

O

19¹⁄ "

(486 mm)

19¹⁄ "

(486 mm)

19¹⁄ "

(486 mm)

19¹⁄ "

(486 mm)

 

 

 

 

P

27¹⁄ "

(692 mm)

27¹⁄ "

(692 mm)

27¹⁄ "

(692 mm)

27¹⁄ "

(692 mm)

 

M O

Q

17¹⁄²"

(444 mm)

17¹⁄²"

(444 mm)

21"

(533 mm)

21"

(533 mm)

 

 

I

P

R

25¹⁄ "

(641 mm)

25¹⁄ "

(641 mm)

28³⁄ "

(730 mm)

28³⁄ "

(730 mm)

 

 

N

E

S

13¹⁄ "

(343 mm)

13¹⁄ "

(343 mm)

15¹⁄ "

(394 mm)

16¹⁄ "

(419 mm)

 

 

I

N

T

17"

(432 mm)

17"

(432 mm)

17³⁄ "

(451 mm)

17³⁄ "

(451 mm)

 

 

M

I

U

13³⁄ "

(349 mm)

13³⁄ "

(349 mm)

15³⁄ "

(400 mm)

16¹⁄ "

(419 mm)

 

 

U N

 

V

18"

(457mm)

18"

(457 mm)

21 ⁄ "

(541 mm)

21 ⁄ "

(541 mm)

 

M G

 

 

 

 

 

 

 

 

 

 

 

Mantels

When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for these clearances.

For applications requiring the use of a Zero Clearance Kit, the minimum height a mantel can be installed above the fireplace is 24" (610 mm) from the top of the upper louvres. The maximum mantel depth is 8" (203 mm). (Fig. 2)

The underside of the mantel will become warm. Use only finishes which are heat resistant and do not discolor.

24" Min. (610mm)

FP1325

Fig. 2 Minimum mantel height above fireplace.

Framing & Finishing

For Zero Clearance Kit applications, it is important to determine the finished facing material before beginning to frame. This will allow for the thickness of the finishing material between the frame and the fireplace trim.

Similarly, consideration must be given to the 1" inch depth of the air inlet channel sitting on the fireplace base. Finishing material for the hearth should be flush with the top of the air inlet channel.

If the fireplace is installed at floor level a noncombustible hearth must extend a minimum 12" (305 mm) in front of the fireplace.

If the fireplace is recessed into the wall and at least 12" (305 mm) above floor level, no hearth is required.

The use of wallpaper adjacent to this fireplace is not recommended as high temperatures given off by this fireplace may adversely effect the binders in the adhesive used to apply the wallpaper.

LHEDV Series Direct Vent Insert

 

 

37¹⁄ " (946mm)

 

 

35"

 

 

(889mm)

 

 

 

 

Air Inlet Channel

 

 

 

27¹⁄ " (692mm)

HEDVCAK is

 

 

installed outside

 

 

 

 

19¹⁄ "

 

ofthe flue pipe

 

 

only.

Drywall

(486mm)

 

 

 

 

Finish Wall

Decorative Trim Kit

 

 

 

FP1351

Fig. 3 LHEDV insert framing dimensions.

 

NOTE: Insulating around the fireplace will result in overheating and possible malfunctioning of the circulating fan.

Zero Clearance Applications

An alternate air supply is recommended with this component.

For installation other than in existing woodburning fireplaces such as new construction or renovation projects, a Zero Clearance Kit must be used. The kit enables these inserts to be installed in combustible environments. Whenever using a Zero Clearance Kit, consideration must be given to the dimensions of the Zero Clearance Kit and the requirements of the Air Kit.

NOTE: If a Zero Clearance Kit is required for models LHECDV20/LHERDV20/LHECDV30/LHERDV30 Direct Vent Inserts, only the CFM Corporation zero clearance kit HEZC combined with the HEDVCAK is approved to be used. Refer to Page 9, figure 10 for HEDVCAK chimney adapter kit installation. When using the HEZC with insert models LHECDV20 or LHERDV20, the Trim Closure Kit, LHE20TCK, must also be installed.

10004894

5

LHEDV Series Direct Vent Insert

Gas Specifications

 

 

 

Max.

Min.

Air Shutter

 

 

Gas

Input

Input

Setting

Model

Fuel

Control

Btu/h

Btu/h

Front

Rear

LHECDV20RN

Natural

Millivolt

20,000

14,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

50%

LHECDV20RP

Propane

Millivolt

20,000

15,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

80%

LHECDV20RFN

Natural

Comfort

20,000

14,000

Fully

Closed

 

 

Control

 

 

Open

50%

LHECDV20RFP

Propane

Comfort

20,000

15,000

Fully

Closed

 

 

Control

 

 

Open

80%

LHERDV20RN

Natural

Millivolt

20,000

14,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

50%

LHERDV20RP

Propane

Millivolt

20,000

15,000

Fully

Closed

 

 

Hi/Lo

 

 

Open

80%

LHECDV30RN

Natural

Millivolt

30,000

21,000

Fully

Fully

 

 

Hi/Lo

 

 

Open

Open

LHECDV30RP

Propane

Millivolt

30,000

22,500

Fully

Fully

 

 

Hi/Lo

 

 

Open

Open

LHECDV30RFN

Natural

Comfort

30,000

21,000

Fully

Fully

 

 

Control

 

 

Open

Open

LHECDV30RFP

Propane

Comfort

30,000

22,500

Fully

Fully

 

 

Control

 

 

Open

Open

LHERDV30RN

Natural

Millivolt

30,000

21,000

Fully

Fully

 

 

Hi/Lo

 

 

Open

Open

LHERDV30RP

Propane

Millivolt

30,000

22,500

Fully

Fully

 

 

Hi/Lo

 

 

Open

Open

Units: GIDN4B0, J23KC0, GIDN3B0, GIDN3H0,

GIDL3H0, M22KC0, M22LC0, M31A30

Gas Inlet & Manifold Pressures

 

Natural

LP

Minimum Inlet Pressure

5.5" W.C.

11.0" W.C.

Maximum Inlet Pressure

14.0" W.C.

14.0" W.C.

Manifold Pressure

3.5" W.C.

10.0" W.C.

Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control which has been under water.

These gas inserts are approved for installation in solid fuel burning masonry or zero clearance fireplaces.

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

LHECDV20 / LHERDV20

LHEDV30 / LHERDV30

Certified To

ANSI Z 21.88-2005 / CSA 2.33-2005

Vented Gas Fireplace Heaters

Preparation

Before beginning, remove glass door and logs from unit. Also check to make sure there is no hidden damage to the unit. Take a minute and plan out the gas,venting and electrical route. It is best to start with the gas line first followed by the chimney liner. (Refer to Page 9)

Gas Line Installation

When purging the gas line, the front glass must be removed.

If gas piping from the source to the heater location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size.

The gas pipeline can be brought in through the rear or the base of the heater.

NOTE: The gas line connection can be made of either properly tinned 3/8" copper tubing, 1/2" rigid pipe or an approved flex connector then reduced to 3/8" to the

heater. Some municipalities have additional local codes, it is always best to consult your local authority and the CSAB149.1 installation code.

U.S. Installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54.

Always check for gas leaks with a mild soap and water solution. Do not use an

open flame for leak testing.

The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

When using copper or flex connector, use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specifications for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater.

6

10004894

 

1/2" Gas Supply

 

1/2" x 3/8" Shut Off Valve

 

3/8" Nipple

 

3/8" Union

 

3/8" Nip-

 

ple

FP297

 

Fig. 4

Typical gas supply installation.

Gas Supply Pressures

This heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure equal to or less than 1/2 psig (3.45kPa).

The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa).

Fan Kit

115 volt, 60 Hz. 56w (Model FK24)

NOTE: The LHERDV20 and LHERDV30 are not designed for a fan kit.

The fan kit includes the following: fan, temperature sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation.

1.Plug in the electrical cord.

2.Start gas fire - see lighting procedures.

3.Turn on fan speed control.

4.Wait until the unit has warmed up sufficiently to activate the temperature sensor, approx. 5-10 minutes.

5.Once fan starts, adjust speed control to desired fan speed. The fan will now automatically come on every time the fireplace is in operation. Should the fan not be needed simply turn off the speed control.

The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.

U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.

Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement components refer to Figure 6.

LHEDV Series Direct Vent Insert

Fan Removal Instructions

1.Turn off gas and electricity.

2.Remove the front glass.

3.Remove the logs.

CAUTION: Logs may be hot!

4.For Model LHECDV20: remove burner assembly and bracket rear log. For Model LHECDV30: remove bracket rear log and cover fan.

5.Remove the fan mounting nuts (2 nuts). (Fig. 5)

6.Slip off the electrical connector at the motor.

7.Lift out the fan.

8.To reinstall reverse procedure.

Screw

Stud

Thermal Sensor is

Fan is Installed

Attached to Burner

at the Back of the

Base

Air Intake Box

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw Stud

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed Control/Junction Box

 

FP1252

Fig. 5

Fan location.

 

Fan

 

Temperature Sensor

Speed

Control

Black

 

White

 

Ground

 

FP394

Fig. 6 Wiring diagram RN/RP. NOTE: For comfort valve wiring diagram refer to Page 18, Figure 27.

Installation of Trim Switch

for RN/RP Gas Valves

1.Thread wire through openings on the right side of fireplace. Do not cut wire or insulation on metal edges.

2.Insert ON/OFF switch with wiring assembly into the bracket switch with the pre-punched opening mounted on the right side of the trim. (Fig. 7)

3.For left side installation, relocate the bracket switch to the left side of the trim kit and repeat Step 2. (Fig. 8)

4.Connect wiring from the switch to the gas valve (Fig. 9a & b).

10004894

7

LHEDV Series Direct Vent Insert

Right Side Installation

Left Side Installation

On/Off

 

Switch As-

On/Off

sembly

Switch As-

 

 

sembly

Wiring from

Millivolt Gas

Valve

FP1330

Fig. 7 Insert ON/OFF switch with wiring assembly into bracket switch.

FP1331

Fig. 8 For left side installation, reverse switch position in bracket.

 

SIT Valve

THTP

 

 

Thermopile

 

 

 

 

 

 

 

TP

 

 

 

 

TH

 

 

 

 

 

 

P

 

 

 

I

 

 

T L

 

 

 

O

 

 

FP382a

 

 

 

 

Fig. 9a

On/Off switch or millivolt thermostat.

 

 

 

Honeywell Valve

 

TH

 

TP

 

TPTH

FP1218

Fig. 9b

On/Off switch wiring.

CAUTION: Do not wire millivolt remote wall switch for gas fireplace to a 120v power supply.

Venting Installation

1.The fireplace may be installed in and vented through any solid fuel fireplace that has a minimum fireplace opening 25¹⁄ "W x 17¹⁄ " H x 13¹⁄ "D (641 x 438 x 343 mm) for LHECDV20 and LHERDV20 or 28³⁄ "W x 21"H x 15¹⁄ "D (730 x 533 x 394 mm) for LHECDV30 and LHERDV30 and has been installed in accordance with the National, Provincial/State and local building codes and is constructed of noncombustible materials.

2.Only HEDVRT RD vent termination kit, HEDVT (8 x 12) or HEDVT (12 x 12) termination kit and flex vent kit HEDVK25 or HEDVK35 are to be use din this installation. Under no circumstances should B vent or C vent be used on this application.

3.Any flue damper must be removed or blocked open.

5.The chimney must be clean and in good working order and constructed of noncombustible materials.

6.Make sure that all chimney cleanouts fit properly so air cannot leak into the chimney.

7.Install the appliance without trim frame and make all gas fittings and electrical connections.

8.Install the decorative trim frame. Please refer to the Frame Assembly instructions.

Installer must attach red warning plate with screws supplied with the gas fireplace insert to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.

Cutting any sheet metal parts of the fireplace, in which the gas fireplace insert is to be installed, is prohibited.

If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1¹⁄ (38 mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship-like manner. This access hole must be plugged with a noncombustible insulation after the gas supply line has been installed.

WARNING

Some factory-built fireplaces have air passages on face of fireplace for zero clearance capabilities.

Under no circumstances should these passages be blocked.

8

10004894

Liner Installation

The collar extending down from the termination base is the air intake connector. Be sure the flex vent, which is connected to this collar, is also connected to the labelled air intake flue collar on the fireplace. Make sure the flex vent is attached on the correct collar and cap for exhaust as well.

Slide the insulation provided in the termination kit over the two (2) 3" flex liners, (to be attached to the 3" flue collar and cap of the termination). Feed one 3" flex vent from the bottom of the termination up through the 4" sleeve. Apply hi-temp sealant on the rain cap collar and slide the flex vent over the end of the rain cap collar fastening with the clamp provided. Slide the flex liner back down the 4" sleeve until 4" cap slides over the sleeve. Attach cap to the sleeve with four (4) screws supplied. Apply hi-temp sealant over the air intake collar and attach intake flex vent in the same method. Feed the two flex liners down the chimney through the damper opening. Tighten termination to the chimney using the screws provided. (Fig. 10) NOTE: For Round Vent Terminations - tighten termination to the chimney by pushing the four (4) straps of the vent termination against the chimney and secure with four (4) screws provided. (Fig. 12)

In case the fireplace opening is only minimum height 21" (533 mm) and access from the front is not possible, follow the instructions below.

1.Remove flue collar plate assembly. Unbolt the top fastener plate and move it to the back first before sliding the flue collar plate out from the top of the unit. (Fig. 13)

2.Apply a bead of hi-temp sealant on the end of the collar before attaching the liner to the flue collar. Fasten it with two clamps then adjust fastener plate all the way to the back before sliding flue gas plate back onto the unit. (Figs. 14 and 15)

3.After the flue collar plate is set on the cabinet top, make sure the front edge of the flue collar plate is completely in contact with the back edge of the cabinet top. (Fig. 16)

4.Put the machine screw back into the fastener plate. Bolt the plate until it is locked. (Fig. 17)

Under no circumstances should insulation be put between the damper and the top of the unit. This may cause condensation and overheating of the unit.

LHEDV Series Direct Vent Insert

Flue gas exits through the vent termination rain cap

Outside combustion air enters through the lower level of the vent termination

Secure with clamp and three screws

1)Attach flexible pipe to rain cap

2)Secure with clamp

3)Attach raincap to vent termiantion using three screws

Pull flexible pipe through vent termination

 

NOTE:

 

Minimum Vent Height

 

- 12 feet

 

Maximum Vent Height

Air Intake

- 35 feet

 

Air intake collar with

Exhaust

 

label secured with

Exhaust collar secured

clamp and three

screws

with clamp and three

 

screws

FP1280

Fig. 10 Liner installation.

Spring located in between the liner and chimney kit

Air Intake

HEZC Zero

Clearance Kit

HEDVCAK

Installation

Secure this kit with three

(3) screws 6ft. provided

(183cm)

Exhaust

FP1280a

Fig. 11 Liner installation with zero clearance kit.

10004894

9

Vermont Casting LHECDV20, LHERDV30, LHECDV30, LHERDV20 User Manual

LHEDV Series Direct Vent Insert

Flue gas exits through the vent termination rain cap

Outside combustion air enters through the lower level of the vent termination

Secure with clamp and three screws

1)Attach flexible pipe to rain cap

2)Secure with clamp

3)Attach raincap to vent termination using three screws

Pull flexible pipe through vent termination

A or B Vent with

7" Inside Minimum and 14" Outside Maximum

NOTE:

Minimum Vent Height

-12 feet Maximum Vent Height

-35 feet

Air Intake

Exhaust

Air intake collar with

 

label secured with

Exhaust collar se-

clamp and three

cured with clamp and

screws

three screws

 

 

FP1280b

Fig. 12

Liner installatin with A or B vent.

 

Fastener

 

Plate

Flue Collar

Plate

 

 

Cabinet

 

Top

 

10/24" x 1¹⁄"

FP1281

Machine Screw

Fig. 13

Remove flue collar plate assembly.

10

 

Damper

3" Flex Vent

 

 

Two Pieces

 

Clamps &

 

Screw

 

Fastener

 

Plate

 

Gasket

Unit

FP1282

Fig. 14 Apply high temperature sealant to end of collar.

 

Damper

3" Chimney Liner

 

 

 

 

Two Pieces

Front

 

 

Frame

 

Clamps &

 

 

screw

 

 

Flue Collar

 

 

Plate

Unit

FP1283

Fig. 15 Fasten with two clamps, adjust fastener plate all the way back.

Fastener Plate

Flue

Collar

Plate

 

 

 

 

 

 

 

 

 

 

Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Make sure the flue collar

 

 

 

 

 

 

 

 

 

plate is in contact with the

 

 

 

 

 

 

 

 

 

back edge of the cabinet

FP1284

 

 

 

 

 

 

top

Fig. 16 The flue collar plate must be completely in contact with back edge of cabinet top.

Fastener Plate

Plate Flue

Collar

Cabinet

Top

FP1285

Machine Screw After

Fastened

 

Fig. 17 Use machine screw to bolt fastener plate in place.

10004894