Tripp Lite Network Dataline Surge Suppressors are designed to protect data and communications equipment against AC transients caused by lightning, electrostatic discharge and ground surges that can enter equipment from the signal lines or chassis ground.
Tripp Lite Network Dataline Surge Suppressors described here protect virtually any pieces of networked equipment using 100Base-T, 10Base-T, 10Base-2 and 10Base-5 Ethernet, Token Ring, RS232, RS422/423/485, parallel, dial-up modems, fax, ISDN, DDS, T-1 and most other communication interfaces.
Installation
1.Make sure the computer, network device or other equipment is logged OFF the network (if applicable). Turn OFF power to the equipment.
2.Disconnect the cable from the equipment to be protected.
3.Connect the Tripp Lite Network Dataline Surge Suppressor directly to the equipment. DB9 and DB25 models are reversible, to work with male or female ports. To change gender, remove the thumbscrews, reverse their direction and reinstall.
4.Attach the green ground wire on the surge suppressor directly to the protected equipment’s chassis. (Except DB9, DB15 and DB25 models.)
5.Reconnect the cable to the Tripp Lite Network Dataline Surge Suppressor.
NOTE!
The Tripp Lite Network Dataline Surge Suppressor must be properly grounded and positioned as close as possible to the equipment to be protected. For best results, it is required that the length of the signal line and ground wire (if equipped) between the surge suppressor and the protected equipment be kept as short as possible, not to exceed 12 inches (12”). It is best to install the surge suppressor directly to the equipment, as noted above.
NOTE!
Installing a typical Tripp Lite Network Dataline Surge Suppressor is equivalent to adding approximately three feet (3’) of typical data communication cable to a segment.
CAUTION!
The Tripp Lite Network Dataline Surge Suppressor does not protect the equipment on the opposite end of the cable. Normally, protection at both ends is recommended.
CAUTION!
When properly installed, the Tripp Lite Network Dataline Surge Suppressor will only protect against surges on the dataline portion of your installation. Simultaneous AC surge suppression/power protection in the form of an ISOBAR® surge suppressor or Tripp Lite UPS system is strongly recommended for complete system/network protection and can also extend Ultimate Lifetime Insurance coverage to connected equipment.
1
SPECIFICATIONS All surge suppressors listed have component response times of less than 1 picosecond.
Model: |
Description: |
Nominal |
Peak Pulse |
Clamping Voltage: |
Current: |
||
DHUB |
|
|
|
DHUB-18V |
DHUB: RJ45, 8-port |
|
|
|
ethernet, token ring |
7.5 volts, protecting |
750 amps |
|
RS422/423/485, AS400/ |
||
|
Sys3x protector for hubs, |
wires 1-8 on all ports. |
|
|
|
|
|
|
repeaters, terminal |
|
|
|
servers, MUXs, MAUs, |
|
|
|
etc.* |
|
|
|
DHUB-18V: RJ45, 8-port |
18 volts, protecting |
340 amps |
|
wires 1-8 on all ports. |
|
|
|
RS 232 protector for |
|
|
|
|
|
|
* Supplied with eight 4” RJ45 patch cables. |
multiport serial devices.* |
|
|
DRS232 |
|
|
|
|
RJ45/RJ11 protector for |
|
|
|
100Base-T4, RS-232 on |
18 volts, protecting wires |
340 amps |
|
twisted pair (wires 1-8) or |
||
|
1-8. |
|
|
|
ISDN “S/T” interfaces. |
|
|
|
|
|
|
|
Supplied with 4” RJ45 |
|
|
|
patch cable. |
|
|
|
|
|
|
DNET1 |
RJ45 100Base-T, 10Base-T, |
|
|
|
|
|
|
|
Token Ring, RS422, AS400/ |
7.5 volts, protecting |
750 amps |
|
Sys3x protector for NICs, |
||
|
hubs, routers, etc. Supplied |
wires 1-8. |
|
|
with 4” RJ45 patch cable. |
|
|
|
|
|
|
DSUT1CSU |
RJ45/RJ11 protector for |
|
|
|
nonspan powered T-1 |
|
|
|
equipment , digital data |
60 volts, protecting wires |
200 amps |
|
service CSUs/DSUs, ISDN |
||
|
“U” interfaces or other |
1-8. |
|
|
digital lines. Supplied |
|
|
|
with 4” RJ45 patch cable. |
|
|
DTEL2 |
|
|
|
|
RJ45/RJ11 for modems, |
260 volts, protecting |
250 amps |
|
answering and fax |
||
|
machines. Supplied with |
center 4 wires (2 CO- |
|
|
4” RJ11 patch cable. |
lines). |
|
|
|
|
|
DB9 |
Serial DB9 RS-232 |
|
|
|
protector for male or |
|
|
|
female ports of data |
|
|
|
terminal and computing |
18 volts, protecting |
340 amps |
|
equipment including |
||
|
PCs, modems, etc. (any |
pins 1-9 and chassis. |
|
|
male or female 9 pin |
|
|
|
port). Male/Female |
|
|
|
genders are reversible |
|
|
|
with reversible |
|
|
DB15AUI |
thumbscrews. |
|
|
|
7.5 and 18 volts, |
|
|
|
DB15 ethernet AUI |
750 amps |
|
|
protecting all IEEE |
||
|
protector. |
||
|
802.3 pins. |
|
|
|
|
|
|
|
|
|
|
2
Model: |
Description: |
Nominal |
Peak Pulse |
Clamping Voltage: |
Current: |
||
|
|
|
|
DB25 |
Serial DB25 RS-232 |
|
|
protector (wires 1-8, |
|
|
|
DB25-ALL |
|
|
|
20) for male or female |
|
|
|
|
|
|
|
|
ports of data terminal |
|
|
|
& computing |
18 volts, protecting |
|
|
equipment. DB25-ALL: |
340 amps |
|
|
Serial DB25 RS-232 |
pins 1-8, 20 and chas- |
|
|
|
||
|
protector (pins 1-25) |
sis. |
|
|
for any 25 pin male or |
|
|
|
female DTE/DCE |
|
|
|
ports. Male/Female |
|
|
|
genders are reversible |
|
|
|
with reversible |
|
|
|
thumbscrews. |
|
|
|
|
|
|
DB25-PAR |
|
|
|
|
Parallel port DB25 |
7.5 volts, protecting |
750 amps |
|
protector (pins 1-25). |
pins 1-25 and chassis. |
|
|
|
|
|
D10B5 |
10Base-5 thick coax |
7.5 volts, protecting |
|
|
|
||
|
protection with “N” |
center, shield and |
750 amps |
|
type male/female |
chassis. |
|
|
connectors. |
|
|
|
|
|
|
D10B2-T |
10Base-2 thin coax |
7.5 volts, protecting |
|
|
|
||
|
protected “T” (BNC f/ |
750 amps |
|
|
center, shield and |
||
|
m/f). Also protects IBM |
||
|
chassis. |
|
|
|
3270 and CCTV lines. |
|
|
|
|
|
|
|
|
|
|
D10B2 |
10Base-2 thin coax |
7.5 volts, protecting |
|
|
|
||
|
protector (BNC m/f). Also |
|
|
|
center, shield and |
750 amps |
|
|
protects IBM 3270 and |
||
|
chassis. |
|
|
|
CCTV lines. |
|
|
|
|
|
|
|
|
|
|
DTWINAX |
|
|
|
|
Twinaxial AS400 Sys3x |
10 volts, protecting |
500 amps |
|
protector (m/f). |
both signal lines, |
|
|
|
||
|
|
shield and chassis. |
|
|
|
|
|
DCATV |
|
|
|
|
Coaxial protector for |
7.5 volts, protecting |
|
|
TVs, VCRs, pro |
750 amps |
|
|
center and shield |
||
|
video supplied by |
|
|
|
conductors. |
|
|
|
CATV |
|
|
|
|
|
|
|
(“F” m/f). |
|
|
|
|
|
|
Call Tripp Lite Customer Support at (773) 869-1234 for additional applications |
3 |
|
requiring Multiport, Terminal Strip, RS422/RS423/RS485 or other interfaces. |
||
|
LIFETIME LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for its lifetime. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609. Seller will pay return shipping charges. Call Tripp Lite at (773) 869-1234 before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction.)
TRIPP LITE
1111 W. 35th Street
Chicago, IL 60609 USA
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.
Policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.
4