Trion SE400E, SE800E User Manual

0 (0)
Trion SE400E, SE800E User Manual

ELECTRONIC

AIR PURIFICATION

SYSTEM

Eliminator

Series

SE400E and SE800E

INSTALLATION

OPERATION

SERVICE

Electrostatic Precipitators for Commercial Applications

101 McNeill Road • Sanford, NC 27330

(919) 775-2201 • Fax: (919) 777-6399 • (800) 884-0002 www.trioninc.com

MANUAL PART NO. 154385-002 • September 2001

1

Contents

 

Section I – Design

Page

1. Introduction………………………..

3

2. The Filter System…………………

3

3. Specifications……………………..

4

Section II - Installation

 

1. Installation…………………………

5-6

2. Diagrams…………………………..

7

Section III – Servicing and Maintenance

 

1. Servicing / Maintenance…………

8

2. Parts List…………………………..

9

3. Exploded Views…………………..

10

Section IV - Reference

 

1. Wiring Diagram SE400E…………

11

2. Wiring Diagram SE 800E………..

12

This manual provides information for installation, operation and maintenance of your Trion SE400E & SE800E. Before installing and using the air purifier, carefully read these instructions to ensure maximum benefits from the unit, and to avoid needless service costs that may result from improper installation

and maintenance.

2

Eliminator SE Series

Section I – Design

1. Introduction

The Trion Eliminator SE400E & SE800E are commercial air purifiers that have been specifically designed to remove airborne pollutants - including tobacco smoke, dust, pollen and mold spores - in rooms and areas where people work or relax. They are designed to be mounted onto a solid ceiling, semi-recessed for into a suspended ceiling, or wall mounted (SE400E only). Where appropriate they can also draw in additional fresh air.

Their features make them the ideal air purifier for installations into areas such as offices, conference rooms, restaurants, designated smoking areas, institutions and waiting rooms or any other place where people gather.

HOW THEY WORK

The Trion SE400E & SE800E utilize the principle of Electrostatic Precipitation. Air is drawn into the intake, through the metal prefilter, which traps lint and large dust particles. The remaining particles, some as small as 0.01 microns*, pass into a strong electrical field (ionizing section) where the particles receive an electrical charge. The charged particles pass onto a series of equally spaced parallel plates (collector section). Each alternate plate is charged with the same polarity as the particles, which are repelled, while the interleaving plates are grounded, and therefore attract and collect the particles.

* The diameter of a human hair is about 100 micron!

2. The Filter System

There are two filters in your air cleaner - THE PRE-FILTER: This is the mechanical filter that lies behind the inlet grill. It is

designed to remove large particles and can be washed many times before replacement.

THE ELECTROSTATIC FILTER: This is the deep aluminum assembly (Collector Cell) located immediately behind the pre-filter and is the heart of your air cleaner. It uses an electrostatic charge to remove particles so small that it would take a pile of many millions to cover a pinhead. When dirty it can be washed and reused indefinitely.

FILTER REMOVAL

TRION SE400E

Turn the control switch off before removing cell. Press the two cell access latches and the hinged door will swing down. Remove pre-filter by turning pre-filter clip 90 degrees (fig 2). While supporting the weight of the Collector Cell, loosen the filter retaining screw (fig 3). The filter retaining plate will now open allowing the filter to be removed (fig 4). To reinstall the filter, simply reverse above procedure.

TRION SE800E

The two hinged access doors are secured with retaining screws (fig 3). Release screws to allow the doors to swing down. Remove the Collector Cells as described above.

INSTALLATION LOCATION

The most effective location for the air purifier is the center of the area to be cleaned because the dirty air is pulled into the center of the unit and discharged equally out the four sides. If more than one unit is required, space them evenly over the area to be cleaned.

3

Eliminator SE Series

3. Specifications

Model

SE400E

 

SE800E

 

Dimensions

Depth:

9.5”

Depth:

9.5”

 

Width:

22.5”

Width:

22.5”

 

Length:

22.5”

Length:

46.12”

Installation

Surface mounted, recessed into suspended ceiling,

 

 

or wall (SE400E only) mounted.

 

 

Weight

42 lbs. / shipping 48 lbs.

Input Power

120 Volts, 1 Phase, 60 Hz

Power Consumed

1.8 Amps, 155 Watts

Controls

Hard-wired remote control

 

with 3-speed selector switch

 

with air-dry (fan only) facility

Motor

1/20 HP, 3-speed, Ball Bearing

Air Flow

200, 300, 400 CFM

Sound Rating

38, 55, 62 dBa

Safety Feature

Interlock to cell access door

Features

Anti-arc circuitry

 

Power to cell indicator

 

Fresh air inlet

 

Dry (fan only) cycle

Options

Infrared remote control

 

Fresh air damper system

80 lbs. / shipping 86 lbs.

120 Volts, 1 Phase, 60 Hz

3.4 Amps, 270 Watts

Hard wired remote control with 3-speed selector switch with air dry (fan only) facility

(2) 1/20 HP, 3-speed, Ball Bearing

400, 600, 800 CFM

41, 58, 65 dBa

Interlock to cell access door

Anti-arc circuitry

Power to cell indicator

Fresh air inlet

Dry (fan only) cycle

Infrared remote control