4YCY4024A through 4YCY4060A

Single Packaged Convertible Gas/Electric

14 SEER

2 - 5 Ton, 40 - 120 KBTU

R-410A

© 2008 Trane

Pub. No. 22-1797-03

Single Packaged Convertible Gas/Electric System

Trane offers a complete family of packaged gas/electric heating and cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas furnace, offering you the best of both energy worlds.

Introducing the new TRANE Single Packaged Convertible Gas/Electric System.

Single Packaged Convertible Gas/ Electric Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane single packaged convertible gas/electric system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control, and air distribution ducts, you have a highly efficient, total home comfort system.

Single Packaged Convertible Gas/ Electric Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service. Every Climatuff® compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability.

2

Contents

Optional Equipment Listing

4

 

 

General Data

5

 

 

Performance Data

 

Cooling

9

Indoor Fan

11

 

 

Typical Wiring

15

 

 

Optional Equipment

18

 

 

Dimensional Data

23

 

 

Mechanical Specifications

29

 

 

3

Optional Equipment Listing

OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [ ] indicates accessories included)

Hinged Filter Access Door (4YCY4024-036) 8 ................................................................

BAYACCDOR1A[

]

Hinged Filter Access Door (4YCY4042-060) 8 ................................................................

BAYACCDOR2A[

]

Roof Curb Full Perimeter (4YCY4024-36A) 3 ...................................................................

BAYCURB050A[

]

Roof Curb Full Perimeter (4YCY4042-60A) 3 ...................................................................

BAYCURB051A[

]

Roof Curb Utility Extension Kit (BAYCURB050A) .................................................................

BAYUTIL101B[

]

Roof Curb Utility Extension Kit (BAYCURB051A) .................................................................

BAYUTIL102B[

]

0-25% Manual Fresh Air Damper (4YCY4024-36A) 1. ......................................................

BAYOSAH001A[

]

0-25% Manual Fresh Air Damper (4YCY4042-60A) 1. ......................................................

BAYOSAH002A[

]

Motorized

Fresh Air Damper (4YCY4024-36A) 1. ............................................................

BAYDMPR101A[

]

Motorized Fresh Air Damper (4YCY4042-60A) 1. .............................................................

BAYDMPR102A[

]

16" Round Duct Adapter (2 per box) (4YCY4024-36A) 6 .................................................

BAYSQRD001A[

]

18" Round Duct Adapter (2 per box) (4YCY4024-60A) 6 .................................................

BAYSQRD002A[

]

0-100% Mod Economizer w/Baro. Relief (4YCY4024-36A) 124 ....................................

BAYECON101B[

]

0-100% Mod. Economizer w/Baro. Relief (4YCY4042-60A) 124. ..................................

BAYECON102B[

]

0-100% Horizontal Economizer (4YCY4024-36A) 12 . ....................................................

BAYECON200A[

]

0-100% Horizontal Economizer (4YCY4042-60A) 12 . ....................................................

BAYECON201A[

]

Enthalpy Control for Economizer (solid state). ....................................................................

BAYENTH001A[

]

Remote Potentiometer (All-BAYECON***A) ............................................................................

BAYSTAT023[

]

1"-2" Filter Frame (4YCY4024-36A) (20 x 25 filter not included) 1. ....................................

BAYFLTR101B[

]

1"-2" Filter Frame (4YCY4042-60A) (20 x 20 & 20 x 18 filter not included) 1.

................... BAYFLTR201B[

]

LP Conversion Kit (All 40K, 120K Models) ...........................................................................

BAYLPKT100A[

]

LP Conversion Kit (All 64K, 96K Models) .............................................................................

BAYLPKT101A[

]

LP Conversion Kit (All 75K Models) .....................................................................................

BAYLPKT102A[

]

Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. .........................................

BAYLOAM105A[

]

Quick Start Kit (4YCY4-A1) ..................................................................................................

BAYQSKT301A[

]

Crankcase Heater Recip (4YCY4024A1 (230v) 5. .............................................................

BAYCCHT101A[

]

Crankcase Heater Scroll (4YCY4036-060A1/3)(230v) 5. ..................................................

BAYCCHT102A[

]

Adapter Curb 4YCY4024-036A to BAYCURB030,38 ........................................................

BAYADAP050A[

]

Adapter Curb 4YCY4024-036A to BAYCURB033 .............................................................

BAYADAP051A[

]

Adapter Curb 4YCY4042-060A to BAYCURB030,38 ........................................................

BAYADAP052A[

]

Adapter Curb 4YCY4042-060A to BAYCURB033 .............................................................

BAYADAP053A[

]

Adapter Curb 4YCY4042-060A to BAYCURB034 .............................................................

BAYADAP054A[

]

12" Duct Shroud Covers Horizontal 4YCY4024-060A7. ...................................................

BAYCOVR112A[

]

18" Duct Shroud Covers Horizontal 4YCY4024-060A 7. ..................................................

BAYCOVR118A[

]

Extreme Condition Mounting Kit - All BAYCURB & BAYADAP .........................................

BAYEXMK001A[

]

Extreme Condition Mounting Kit - All BAYUTIL ..................................................................

BAYEXMK002B[

]

Extreme Condition Mounting Kit - All Slab Mounts .............................................................

BAYEXMK003A[

]

Lifting Lug Kit ..........................................................................................................................

BAYLlFT002B[

]

NOTES:

1 Must use filter frame when economizer/fresh air kit is used.

 

 

 

2 Dry bulb control standard with economizer.

 

 

 

3 Ships knocked down.

 

 

 

4 Downflow only.

 

 

 

5 Low Ambient cooling requires crankcase heater (BAYCCHT----

A).

 

6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications

8BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A.

4

General Data

MODEL

4YCY4024A1064A

4YCY4030A1075A

4YCY4036A1075A

4YCY4036A1096A

RATED Volts/PH/Hz

 

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

 

 

Performance Cooling BTUH

 

23400

30000

36000

36000

 

 

Indoor Airflow (CFM)

 

790

900

1210

1210

 

 

Power Input (KW)

 

2.162

2.5

3.284

3.284

 

 

EER/SEER(BTU/Watt-Hr.)

 

11.6 / 14.0

12.0 / 14.0

11.6 / 14.2

11.6 / 14.2

 

 

Sound Power Rating [dB(A)]8

 

68

71

69

69

 

 

Performance Heating

 

48000

56250

56250

72000

 

 

Input BTUH - 1st Stage (Natural Gas)

 

 

Input BTUH - 2nd Stage (Natural Gas)

64000

75000

75000

96000

 

 

AFUE

 

79.0

79.5

79.5

80.0

 

 

Temp. Rise — Min/Max (°F)

 

35 / 65

30 / 60

30 / 60

40 / 70

 

 

Orifice Qty / Drill Size (Natural Gas)

2 / #37

2 / #33

2 / #33

3 / #37

 

 

POWER CONN.—V/PH/HZ

 

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

 

 

Min. Brch. Cir. Ampacity

 

16.5

19.2

24.6

24.6

 

 

Fuse Size — Max. (amps)

 

25

30

40

40

 

 

Fuse Size — Recmd. (amps)

 

25

30

40

40

 

 

COMPRESSOR

RECIPROCATING

RECIPROCATING

SCROLL

SCROLL

Volts/Ph/Hz

 

208-230/1/60

200-230/1/60

208-230/1/60

208-230/1/60

 

 

R.L. Amps — L.R. Amps

 

8.3 / 57.8

11.1 / 63

15.4 / 83

15.4 / 83

 

 

OUTDOOR COIL — TYPE

 

SPINE-FIN

SPINE-FIN

SPINE-FIN

SPINE-FIN

 

Rows/F.P.I.

 

2 / 24

2 / 24

2 / 24

2 / 24

 

 

Face Area (sq.ft.)

 

13.32

15.49

15.49

15.49

 

 

Tube Size (in.)

 

3/8

3/8

3/8

3/8

 

 

INDOOR COIL — TYPE

 

PLATE FIN

PLATE FIN

PLATE FIN

PLATE FIN

 

Rows/F.P.I.

 

3 / 15

3 / 15

4 / 15

4 / 15

 

 

Face Area (sq.ft.)

 

3.54

3.54

3.54

3.54

 

 

Tube Size (in.)

 

3/8

3/8

3/8

3/8

 

 

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

 

PROPELLER

PROPELLER

PROPELLER

PROPELLER

 

Dia. (in.)

 

23.4

23.4

23.4

23.4

 

 

Drive/No. Speeds

 

DIRECT / 1

DIRECT / 1

DIRECT / 1

DIRECT / 1

Motor — HP/R.P.M.

 

1/12 / 810

1/6 / 830

1/5 / 830

1/5 / 830

 

 

Volts/Ph/Hz

 

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

 

 

F.L. Amps/L.R. Amps

 

0.54 / 0.95

1.0 / 1.7

1.1 / 1.9

1.1 / 1.9

 

 

INDOOR FAN — TYPE

 

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

 

Dia x Width (in.)

 

10 X 10

10 X 10

10 X 10

10 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

CFM @ 0.0 in. w.g.

SEE FAN PERF TABLE

SEE FAN PERF TABLE

SEE FAN PERF TABLE

SEE FAN PERF TABLE

Motor — HP/R.P.M.

 

1/2 / VARIABLE

1/2 / VARIABLE

1/2 / VARIABLE

1/2 / VARIABLE

Volts/Ph/Hz

 

200-230/1/60

208-230/1/60

200-230/1/60

200-230/1/60

 

 

F.L. Amps/L.R. Amps

 

4.3 / 4.3

4.3 / 4.3

4.3 / 4.3

4.3 / 4.3

 

 

COMBUSTION FAN — TYPE

 

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

 

Drive/No. Speeds

 

DIRECT / 2

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

1/45 / 2800/1500

1/45 / 2800/1500

1/45 / 2800/1500

 

 

Volts/Ph/Hz

 

208-230/1/60

208-230/1/60

208-230/1/60

208-230/1/60

 

 

FLA

 

0.34

0.34

0.34

0.34

 

 

FILTER / FURNISHED

 

NO

NO

NO

NO

 

Type Recommended

 

THROWAWAY

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

 

4.0

4.0

4.0

4.0

 

 

REFRIGERANT

 

R410A

R410A

R410A

R410A

 

Charge (lbs.)

 

5.8

6.0625

6.75

6.75

 

 

GAS PIPE SIZE (in.)

 

1/2

1/2

1/2

1/2

 

 

DIMENSIONS

 

H X W X L

H X W X L

H X W X L

H X W X L

 

Crated (in.)

45.86 / 44.5 / 52.03

45.86 / 44.5 / 52.03

47.86 / 44.5 / 52.03

47.86 / 44.5 / 52.03

 

 

WEIGHT

 

481 / 385

481 / 385

488 / 392

493 / 397

 

 

Shipping (lbs.) / Net (lbs.)

 

 

 

1Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270.

2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.

8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

5

General Data

MODEL

4YCY4036A3075A

4YCY4036A3096A

4YCY4042A1096A

RATED Volts/PH/Hz

208-230/3/60

208-230/3/60

208-230/1/60

 

Performance Cooling BTUH

36000

36000

42000

 

Indoor Airflow (CFM)

1210

1210

1350

 

Power Input (KW)

3.284

3.284

3.5

 

EER/SEER(BTU/Watt-Hr.)

11.6 / 14.2

11.6 / 14.2

12.0 / 14.25

 

Sound Power Rating [dB(A)]8

69

69

74

 

 

Performance Heating

56250

72000

 

 

Input BTUH - 1st Stage (Natural Gas)

72000

 

Input BTUH - 2nd Stage (Natural Gas)

75000

96000

96000

 

AFUE

80.0

80.0

80

 

Temp. Rise — Min/Max (°F)

30 / 60

40 / 70

30 / 60

 

Orifice Qty / Drill Size (Natural Gas)

2 / #33

3 / #37

3 / #37

 

POWER CONN.—V/PH/HZ

208-230/3/60

208-230/3/60

208-230/1/60

 

Min. Brch. Cir. Ampacity

19.8

19.8

31.5

 

Fuse Size — Max. (amps)

30

30

50

 

Fuse Size — Recmd. (amps)

30

30

50

 

 

COMPRESSOR

SCROLL

SCROLL

SCROLL

Volts/Ph/Hz

208-230/3/60

208-230/3/60

208-230/1/60

 

R.L. Amps — L.R. Amps

11.5 / 77

11.5 / 77

18.6 / 105

 

OUTDOOR COIL — TYPE

SPINE-FIN

SPINE-FIN

SPINE-FIN

 

Rows/F.P.I.

2 / 24

2 / 24

2 / 24

 

Face Area (sq.ft.)

15.49

15.49

23.57

 

Tube Size (in.)

3/8

3/8

3/8

 

INDOOR COIL — TYPE

PLATE FIN

PLATE FIN

PLATE FIN

 

Rows/F.P.I.

4 / 15

4 / 15

3 / 15

 

Face Area (sq.ft.)

3.54

3.54

5

 

Tube Size (in.)

3/8

3/8

3/8

 

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

PROPELLER

PROPELLER

 

Dia. (in.)

23.4

23.4

28.2

 

Drive/No. Speeds

DIRECT / 1

DIRECT / 1

DIRECT / 1

Motor — HP/R.P.M.

1/5 / 830

1/5 / 830

1/4 / 825

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

F.L. Amps/L.R. Amps

1.1 / 1.9

1.1 / 1.9

1.5 / 3.4

 

 

INDOOR FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Dia x Width (in.)

10 X 10

10 X 10

11 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

CFM @ 0.0 in. w.g.

SEE FAN PERF TABLE

SEE FAN PERF TABLE

SEE FAN PERF TABLE

Motor — HP/R.P.M.

1/2 / VARIABLE

1/2 / VARIABLE

3/4 / VARIABLE

Volts/Ph/Hz

200-230/1/60

200-230/1/60

208-230/1/60

 

F.L. Amps/L.R. Amps

4.3 / 4.3

4.3 / 4.3

6.8 / 6.8

 

COMBUSTION FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

 

Drive/No. Speeds

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

1/45 / 2800/1500

1/45 / 2800/1500

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

FLA

0.34

0.34

0.34

 

FILTER / FURNISHED

NO

NO

NO

 

Type Recommended

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

4.0

4.0

5.3

 

REFRIGERANT

R410A

R410A

R410A

 

Charge (lbs.)

6.75

6.75

6.8125

 

 

GAS PIPE SIZE (in.)

1/2

1/2

1/2

 

 

DIMENSIONS

H X W X L

H X W X L

H X W X L

Crated (in.)

47.86 / 44.5 / 52.03

47.86 / 44.5 / 52.03

47.86 / 47.4 / 61.75

 

WEIGHT

488 / 392

 

 

 

Shipping (lbs.) / Net (lbs.)

493 / 397

653 / 525

 

1Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270.

2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.

8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

6

General Data

MODEL

4YCY4048A1096A

4YCY4048A1120A

4YCY4048A3096A

RATED Volts/PH/Hz

208-230/1/60

208-230/1/60

208-230/3/60

 

Performance Cooling BTUH

48000

48000

48000

 

Indoor Airflow (CFM)

1605

1605

1605

 

Power Input (KW)

4.034

4.034

4.034

 

EER/SEER(BTU/Watt-Hr.)

11.9 / 14.2

11.9 / 14.2

11.9 / 14.2

 

Sound Power Rating [dB(A)]8

73

73

73

 

 

Performance Heating

72000

 

 

 

Input BTUH - 1st Stage (Natural Gas)

90000

72000

 

Input BTUH - 2nd Stage (Natural Gas)

96000

120000

96000

 

AFUE

80.0

80.0

80.0

 

Temp. Rise — Min/Max (°F)

30 / 60

40 / 70

30 / 60

 

Orifice Qty / Drill Size (Natural Gas)

3 / #37

3 / #32

3 / #37

 

POWER CONN.—V/PH/HZ

208-230/1/60

208-230/1/60

208-230/3/60

 

Min. Brch. Cir. Ampacity

33.8

33.8

26.4

 

Fuse Size — Max. (amps)

50

50

40

 

Fuse Size — Recmd. (amps)

50

50

40

 

 

COMPRESSOR

SCROLL

SCROLL

SCROLL

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/3/60

 

R.L. Amps — L.R. Amps

20.5 / 109

20.5 / 109

14.6 / 91

 

OUTDOOR COIL — TYPE

SPINE-FIN

SPINE-FIN

SPINE-FIN

 

Rows/F.P.I.

2 / 24

2 / 24

2 / 24

 

Face Area (sq.ft.)

18.01

18.01

18.01

 

Tube Size (in.)

3/8

3/8

3/8

 

INDOOR COIL — TYPE

PLATE FIN

PLATE FIN

PLATE FIN

 

Rows/F.P.I.

3 / 15

3 / 15

3 / 15

 

Face Area (sq.ft.)

5.0

5.0

5.0

 

Tube Size (in.)

3/8

3/8

3/8

 

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

PROPELLER

PROPELLER

 

Dia. (in.)

28.2

28.2

28.2

 

Drive/No. Speeds

DIRECT / 1

DIRECT / 1

DIRECT / 1

Motor — HP/R.P.M.

1/4 / 825

1/4 / 825

1/4 / 825

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

F.L. Amps/L.R. Amps

1.4 / 3.5

1.4 / 3.37

1.4 / 3.5

 

 

INDOOR FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Dia x Width (in.)

11 X 10

11 X 10

11 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

CFM @ 0.0 in. w.g.

SEE FAN PERF TABLE

SEE FAN PERF TABLE

SEE FAN PERF TABLE

Motor — HP/R.P.M.

3/4 / VARIABLE

3/4 / VARIABLE

3/4 / VARIABLE

Volts/Ph/Hz

200-230/1/60

200-230/1/60

200-230/1/60

 

F.L. Amps/L.R. Amps

6.8 / 6.8

6.8 / 6.8

6.8 / 6.8

 

COMBUSTION FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

 

Drive/No. Speeds

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

1/45 / 2800/1500

1/45 / 2800/1500

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

FLA

0.34

0.34

0.34

 

FILTER / FURNISHED

NO

NO

NO

 

Type Recommended

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

5.3

5.3

5.3

 

REFRIGERANT

R410A

R410A

R410A

 

Charge (lbs.)

8.2

8.2

8.2

 

 

GAS PIPE SIZE (in.)

1/2

1/2

1/2

 

 

DIMENSIONS

H X W X L

H X W X L

H X W X L

Crated (in.)

47.86 / 47.4 / 61.75

47.86 / 47.4 / 61.75

47.86 / 47.4 / 61.75

 

WEIGHT

653 / 525

 

 

 

Shipping (lbs.) / Net (lbs.)

659 / 531

653 / 525

 

1Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270.

2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.

8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

7

General Data

MODEL

4YCY4048A3120A

4YCY4060A1120A

4YCY4060A3120A

RATED Volts/PH/Hz

208-230/3/60

208-230/1/60

208-230/3/60

 

Performance Cooling BTUH

48000

58500

58500

 

Indoor Airflow (CFM)

1605

1800

1800

 

Power Input (KW)

4.034

5.478

5.478

 

EER/SEER(BTU/Watt-Hr.)

11.9 / 14.2

11.9 / 14.0

11.9 / 14.0

 

Sound Power Rating [dB(A)]8

73

76

76

 

 

Performance Heating

90000

90000

90000

 

Input BTUH - 1st Stage (Natural Gas)

 

Input BTUH - 2nd Stage (Natural Gas)

120000

120000

120000

 

AFUE

80.0

80.0

80.0

 

Temp. Rise — Min/Max (°F)

40 / 70

30 / 60

30 / 60

 

Orifice Qty / Drill Size (Natural Gas)

3 / #32

3 / #32

3 / #32

 

POWER CONN.—V/PH/HZ

208-230/3/60

208-230/1/60

208-230/3/60

 

Min. Brch. Cir. Ampacity

26.4

42.3

30.6

 

Fuse Size — Max. (amps)

40

60

45

 

Fuse Size — Recmd. (amps)

40

60

45

 

 

COMPRESSOR

SCROLL

SCROLL

SCROLL

Volts/Ph/Hz

208-230/3/60

208-230/1/60

208-230/3/60

 

R.L. Amps — L.R. Amps

14.6 / 91

26.9 / 145

17.6 / 123

 

OUTDOOR COIL — TYPE

SPINE-FIN

SPINE-FIN

SPINE-FIN

 

Rows/F.P.I.

2 / 24

2 / 24

2 / 24

 

Face Area (sq.ft.)

18.01

23.07

23.07

 

Tube Size (in.)

3/8

3/8

3/8

 

INDOOR COIL — TYPE

PLATE FIN

PLATE FIN

PLATE FIN

 

Rows/F.P.I.

3 / 15

4 / 15

4 / 15

 

Face Area (sq.ft.)

5.0

5.0

5.0

 

Tube Size (in.)

3/8

3/8

3/8

 

Refrigerant Control

EXPANSION VALVE

EXPANSION VALVE

EXPANSION VALVE

Drain Conn. Size (in.)

3/4 FEMALE NPT

3/4 FEMALE NPT

3/4 FEMALE NPT

OUTDOOR FAN — TYPE

PROPELLER

PROPELLER

PROPELLER

 

Dia. (in.)

28.2

28.2

28.2

 

Drive/No. Speeds

DIRECT / 1

DIRECT / 1

DIRECT / 1

Motor — HP/R.P.M.

1/4 / 825

1/3 / 830

1/3 / 830

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

F.L. Amps/L.R. Amps

1.4 / 3.37

1.7 / 3.5

1.7 / 3.5

 

 

INDOOR FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

Dia x Width (in.)

11 X 10

11 X 10

11 X 10

Drive/No. Speeds

DIRECT / VARIABLE

DIRECT / VARIABLE

DIRECT / VARIABLE

CFM @ 0.0 in. w.g.

SEE FAN PERF TABLE

SEE FAN PERF TABLE

SEE FAN PERF TABLE

Motor — HP/R.P.M.

3/4 / VARIABLE

1 / VARIABLE

1 / VARIABLE

Volts/Ph/Hz

200-230/1/60

208-230/1/60

208-230/1/60

 

F.L. Amps/L.R. Amps

6.8 / 6.8

6.9 / 6.9

6.9 / 6.9

 

COMBUSTION FAN — TYPE

CENTRIFUGAL

CENTRIFUGAL

CENTRIFUGAL

 

Drive/No. Speeds

DIRECT / 2

DIRECT / 2

DIRECT / 2

Motor — HP/R.P.M.

1/45 / 2800/1500

1/45 / 2800/1500

1/45 / 2800/1500

 

Volts/Ph/Hz

208-230/1/60

208-230/1/60

208-230/1/60

 

FLA

0.34

0.34

0.34

 

FILTER / FURNISHED

NO

NO

NO

 

Type Recommended

THROWAWAY

THROWAWAY

THROWAWAY

Recmd. Face Area (sq. ft.)

5.3

5.3

5.3

 

REFRIGERANT

R410A

R410A

R410A

 

Charge (lbs.)

8.2

9.75

9.75

 

 

GAS PIPE SIZE (in.)

1/2

1/2

1/2

 

 

DIMENSIONS

H X W X L

H X W X L

H X W X L

Crated (in.)

47.86 / 47.4 / 61.75

51.86 / 47.4 / 61.75

51.86 / 47.4 / 61.75

 

WEIGHT

659 / 531

676 / 548

676 / 548

 

Shipping (lbs.) / Net (lbs.)

 

1Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270.

2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation.

3 Convertible to LPG.

4 This value is approximate. For more precise value, see Unit Nameplate.

5 Based on U.S. Government Standard Tests.

6Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C.

7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit.

8 Sound Power values are not adjusted for ARI 270-95 tonal corrections.

8

Performance Data Cooling

4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

29.8

24.1

26.9

29.2

28.9

2.3

85

63

31.0

19.7

22.6

25.5

27.4

2.3

67

33.4

15.8

18.6

21.5

23.4

2.3

 

 

71

36.1

11.8

14.6

17.5

19.4

2.3

 

59

27.3

23.0

25.8

27.3

27.3

2.5

95

63

28.5

18.7

21.5

24.4

26.3

2.5

67

30.7

14.7

17.6

20.4

22.3

2.5

 

 

71

33.1

10.7

13.6

16.5

18.4

2.5

 

 

 

 

 

 

 

 

 

59

24.8

21.9

24.7

24.8

24.8

2.7

105

63

25.9

17.6

20.5

23.3

25.2

2.7

67

27.9

13.7

16.5

19.4

21.3

2.7

 

 

71

30.1

9.7

12.6

15.4

17.4

2.7

 

 

 

 

 

 

 

 

 

59

22.4

20.8

22.4

22.4

22.4

2.9

115

63

23.3

16.6

19.5

22.3

23.3

2.9

67

25.1

12.7

15.5

18.4

20.3

2.9

 

 

71

27.1

8.7

11.6

14.4

16.4

2.9

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

875

0.97

 

0.98

HIGH

1125

1.03

 

1.02

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

890

30000

 

14.00

12.00

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4024A1 AT 800 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

22.9

19.1

21.4

22.9

22.9

1.8

85

63

23.9

15.6

17.9

20.2

21.8

1.8

67

25.8

12.3

14.7

17.0

18.6

1.9

 

 

71

27.8

9.1

11.5

13.8

15.3

1.9

 

59

20.9

18.2

20.5

20.9

20.9

2.0

95

63

21.8

14.7

17.0

19.3

20.9

2.0

67

23.5

11.5

13.8

16.1

17.7

2.0

 

 

71

25.3

8.3

10.6

12.9

14.5

2.0

 

59

18.8

17.3

18.8

18.8

18.8

2.1

105

63

19.6

13.8

16.1

18.5

19.6

2.1

67

21.1

10.6

12.9

15.3

16.8

2.2

 

 

71

22.8

7.4

9.7

12.1

13.6

2.2

 

59

16.7

16.4

16.7

16.7

16.7

2.3

115

63

17.5

13.0

15.3

17.5

17.5

2.3

67

18.8

9.8

12.1

14.4

16.0

2.3

 

 

71

20.3

6.6

8.9

11.2

12.8

2.3

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

700

0.97

 

0.98

HIGH

900

1.03

 

1.02

 

 

 

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

790

23400

 

14.00

11.60

 

 

 

 

 

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES)

OD

ID

TOT

SENS CAP AT ENTERING DB TEMP

TOTAL

AMB

WB

CAP

72

75

78

80

KW

 

59

34.5

28.8

32.4

34.5

34.5

2.7

85

63

36.0

23.4

27.0

30.5

32.9

2.7

67

38.8

18.5

22.0

25.6

27.9

2.8

 

 

71

41.9

13.5

17.1

20.6

23.0

2.8

 

59

32.0

27.6

31.2

32.0

32.0

3.0

95

63

33.4

22.3

25.9

29.4

31.8

3.1

67

35.9

17.4

20.9

24.5

26.9

3.1

 

 

71

38.8

12.4

16.0

19.6

21.9

3.1

 

59

29.5

26.5

29.5

29.5

29.5

3.3

105

63

30.7

21.2

24.8

28.4

30.7

3.4

67

33.1

16.3

19.9

23.4

25.8

3.4

 

 

71

35.7

11.4

15.0

18.5

20.9

3.4

 

59

26.9

25.4

26.9

26.9

26.9

3.6

115

63

28.1

20.2

23.7

27.3

28.1

3.7

67

30.2

15.3

18.8

22.4

24.8

3.7

 

 

71

32.7

10.4

13.9

17.5

19.9

3.7

USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW

 

AIR FLOW

CAPACITY

 

TOTAL POWER

 

RATE, CFM

MULTIPLIER

 

MULTIPLIER

LOW

1050

0.97

 

0.98

HIGH

1350

1.03

 

1.02

 

ARI RATING FOR COOLING

 

CFM

CAPACITY (A) TEST

SEER

EER

1210

36000

 

14.20

11.60

ARI Standard Capacity Rating Conditions

ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling.

9

Loading...
+ 20 hidden pages