Wolf P1363418, P1423418, P1543418, P1663418 Owner's Manual

0 (0)
Wolf P1363418, P1423418, P1543418, P1663418 Owner's Manual

P R O I S L A N D V E N T I L AT I O N H O O D S

INSTALLATION INSTRUCTIONS

C O N TA C T

I N F O R M AT I O N

Wolf Customer Service: 800-332-9513

Website:

wolfappliance.com

As you follow these instructions, you will notice WARNING and CAUTION symbols. This blocked information is important for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation.

signals a situation where minor injury or product damage may occur if you do not follow instructions.

states a hazard that may cause serious injury or death if precautions are not followed.

Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation.

WOLF® is a registered trademark of Wolf Appliance Company, LLC

W O L F PRO ISLAND VENTILATION H O O D S

INSTALLATION R E Q U I R E M E N T S

 

 

IMPORTANT NOTE: This installation must be

L I S T O F M AT E R I A L S

completed by a qualified installer or Wolf

The following is a list of materials shipped

authorized service center technician.

with the Wolf Pro island ventilation hood.

 

 

Installer: Please read the entire Installation

 

 

 

 

 

 

 

 

 

 

Instructions prior to installation. Save these

 

Stainless steel island hood

 

 

instructions for the local inspector’s refer-

 

 

 

 

 

 

 

 

 

 

ence, then leave them with the homeowner.

 

Transition with backdraft damper (attached

 

 

 

 

 

Homeowner: Please read and keep these

 

inside hood—needs to be removed)

 

 

 

 

 

 

instructions for future reference and be sure

 

Decorative stainless steel rails and installa-

 

 

 

 

 

to read the entire Use & Care Information

 

tion components—(R) model hoods only

 

 

prior to use.

 

Two control knobs

Any questions or problems about the

 

 

Filters and grease cups (installed in hood)

installation should be directed to your Wolf

 

 

 

dealer or Wolf Appliance Company, LLC at

 

(8–16) #10 x 2" (51) self-tapping hex head

 

800-332-9513. You can also visit our website

 

screws (number of screws varies with the

at wolfappliance.com.

 

width of the island hood)

IMPORTANT NOTE: This appliance must be

 

(4) 1/4" x 3" (76) lag screws

 

installed in accordance with National Electrical

 

Installation package (taped to filters)

Codes, as well as all state, municipal and local

 

 

Installation Instructions

codes. The correct voltage, frequency and

 

 

amperage must be supplied to the appliance

 

Use & Care Information and product

from a dedicated, grounded circuit which is

 

 

registration card

protected by a properly sized circuit breaker or

 

 

Wolf logo nameplate

time delay fuse. The proper voltage, frequency,

 

 

 

 

and amperage ratings are listed on the product

 

 

rating plate.

 

 

Record the model and serial numbers before

 

 

installing the Pro island ventilation hood. Both

 

 

numbers are listed on the rating plate, located

 

 

on the left wall of the hood shell.

 

 

Island Hood

Island Hood

(R) Rail Option

Model Number

Serial Number

Location of rating plate inside left wall

Rating plate location

 

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

3

A C C E S S O R I E S

Optional accessories are available through your

Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.

W O L F PRO ISLAND VENTILATION H O O D S

INSTALLATION C O N S I D E R AT I O N S

IMPORTANT NOTE: Wolf Pro island ventilation hoods are recommended for use with all Wolf cooking appliances.

Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered

under the Wolf Warranty. Refer to the Wolf Pro Ventilation Hoods Use & Care Information for warranty details, or visit the Contact/Help section of our website, wolfappliance.com.

Make sure you have the tools and materials necessary for proper installation.

Warranty service must be performed by a Wolf authorized service center. Wolf is not responsible for service required to correct a faulty installation.

IMPORTANT NOTE: Wolf Pro ventilation hoods are shipped without the blower assembly. Wolf internal, in-line and remote blower assemblies are available; refer to pages 13–15. Use only a Wolf blower with the Pro island hood.

IMPORTANT NOTE: Wolf recommends that the Pro island ventilation hood be installed 30" (762) to 36" (914) above the countertop.

Rail option (R) island hoods come with classic stainless steel decorative rails and stand-offs on both sides of the hood. Optional platinum or brass rails are available to match Wolf dual fuel range bezels. Contact your Wolf dealer for details.

E L E C T R I C A L R E Q U I R E M E N T S

Wolf Pro island ventilation hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Locate the electrical supply through the top of the hood. Refer to the Installation Specifications illustration on the following page.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

D U C T C O V E R

If you are installing a Wolf duct cover with the Pro island hood, refer to instructions on page 8 before installing the hood.

4

INSTALLATION I N S T R U C T I O N S

OVERALL D I M E N S I O N S

P RO I S L A N D H O O D S

Overall Widths

36" (914), 42" (1067),

 

54" (1372) and 66" (1676)

 

 

 

Overall Height

 

18" (457)

 

 

Overall Depth (excluding rails)

34" (864)

 

 

Shipping Weight (shell only)

95–168 lbs

 

 

(43–76 kg)

 

 

 

Dimensions may vary to ±1/8" (3).

 

 

 

 

 

TOP WIDTH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUBTRACT 18" (457) FROM OVERALL WIDTH

 

 

 

 

 

 

 

 

 

 

(330)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4" (19)

 

 

 

 

 

 

 

 

 

 

 

18"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(457)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OVERALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

 

 

OF RAIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"(102)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OVERALL WIDTH

 

 

 

 

 

 

2"

 

 

 

 

 

 

 

 

 

 

34" (864)

 

 

 

 

 

 

 

2"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(51)

 

 

 

 

 

 

 

OVERALL DEPTH

 

 

(51)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pro Island Hood

INSTALLATION S P E C I F I C AT I O N S

LOCATION OF ELECTRICAL SUPPLY

CENTERED THROUGH TOP OF HOOD

 

 

 

 

 

 

18" (457)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

 

 

 

 

 

 

 

 

 

OF HOOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34" (864)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIDTH OF HOOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DEPTH OF HOOD

 

 

 

 

 

 

 

 

 

 

30" TO 36"

 

 

30" TO 36"

 

(762–914)

 

 

 

(762–914)

TO COUNTERTOP

 

 

TO COUNTERTOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pro Island Hood

Dimensions in parentheses are in

 

millimeters unless otherwise specified.

5

W O L F PRO ISLAND VENTILATION

INSTALLATION S P E C I F I C AT I O N S

The illustration and chart below provides dimensions critical for proper installation of the Wolf Pro island ventilation hood.

B

WIDTH OF

TOP PLATE

10" (254) 61/2" (165)

C

13"

(330)

HEIGHT OF

 

TRANSITION

 

D

TO CENTER

OF TRANSITION

34" (864)

A

DEPTH OF

WIDTH OF

HOOD

HOOD

 

 

Pro Island Hoods

H O O D S

To reduce the risk of fire and electric shock, install this ventilation hood only with a blower manufactured by Wolf. Blower model numbers are listed on page 17.

Model

(A)

(B)

(C)

(D)

I363418

36" (914)

18" (457)

8 3/4" (222)

9" (228)

I423418

42" (1066)

24" (610)

8 3/4" (222)

12" (304)

I543418

54" (1371)

36" (914)

8 3/4" (222)

18" (457)

I663418

66" (1676)

48" (1219)

8 3/4" (222)

24" (610)

Letters correspond to those in the illustration.