Electronic Window Air Conditioner
Operating Instructions
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner.
Store Name: ____________________________________________________
Location: ______________________________________________________
Date Purchased: _________________________________________________
Serial Number (located on back of unit): ______________________________
IMPORTANT SAFETY INSTRUCTIONS
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
• Plug into a grounded 3 prong outlet. |
• Do not use an extension cord. |
||
• |
Do not remove the ground prong. |
• |
Unplug the air conditioner before servicing |
• |
Do not use a plug adapter. |
• |
Use two or more people to move and install the air |
|
|
|
conditioner |
This is a safety alert symbol.
This symbol alerts you to potential hazards that can harm you or others or even cause death.
All safety messages will directly follow the safety alert symbol and/or the words “DANGER” or “WARNING”.
Failure to immediately follow these instructions may cause serious injury or even death.
All Safety messages alert you of potential hazards, how to reduce the chance of injury, and what can happen if instructions are not followed correctly.
2
Electrical Shock Hazard Plug into a grounded 3 prong outlet.
Do not remove the ground prong. Do not use an adapter
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock
Recommended Ground Method
The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front).
Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord.
Wiring Requirements |
Power Supply Cord |
|
|
•115 volt (103.5 min.—126.5 max)
•0-12 amps
•15-amp time-delay fuse or circuit breaker
•Use on single outlet circuit only
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
It is the customer’s responsibility:
•To contact a qualified electrician
•To assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269
LCDI Power Cord and Plug
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged and leakage occurs, power will be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:
1.Plug power cord into a grounded 3 prong outlet
2.Press RESET (on some units a green light will turn on).
3.Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light may turn off.
4.Press the RESET button for use. You will hear a click and the A/C is not ready for use.
NOTES:
•The RESET button must be engaged for proper use.
•The power supply cord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset.
•Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device.
•A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree.
•The power supply cord contains new user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.
NOTE: Your units power cord and plug may differ from the one shown.
3
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2/5” |
|
4/5” |
|
Sash Lock (1) |
|
|
|
|
Screw (4) |
|
Screw (6) |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Packing List:
•Window Air Conditioner
•Remote Control
•AAA Batteries (2)
•Top Mounting Rail
•Top Mounting Rail Seal Strip
•2/5” Screw for Top Mounting Rail (4)
•Accordion Panels (Left & Right)
•Sash Lock (1)
•Window Sash Seal
•4/5” Screw for Window Locking Bracket & Accordion Panels (6)
•Foam Top Window Gasket
•Owner’s Manual
4
SPECIFICATIONS
•Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode.
•Power consumption is measured when the fan runs at the highest speed setting.
•These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.
Model |
GM WAC 06SE C |
GM WAC 06ESE C |
GM WAC 08ESE C |
Energy Star |
No |
Yes |
Yes |
Power Supply (Ph/V/Hz) |
1/115/60 |
1/115/60 |
1/115/60 |
Rated Cooling Capacity (BTU/h) |
6,300 |
6,300 |
8,000 |
Cooling Power Input (Watts) |
590 |
590 |
740 |
Rated Current Cooling (Amperage) |
5.3 |
5.3 |
7.1 |
Cooling EER |
10.7 |
10.7 |
10.8 |
Noise Level H/M/L [dB(A)] |
56/55/54 |
56/55/54 |
58/56/54 |
Air Flow H/M/L (CFM) |
190/180/170 |
190/180/170 |
195/183/170 |
Dehumidifying Capacity |
30 Pints per day |
30 Pints per day |
40 Pints per day |
Product Dimensions (W" x H" x D") |
18.625 x 12.75 x 15.75 |
18.625 x 12.75 x 15.75 |
18.625 x 12.75 x 15.75 |
Product Weight (lbs) |
46 |
46 |
50 |
Refrigerant Type |
R 410A |
R 410A |
R 410A |
DISCLAIMER
ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER. SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT
TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
5