Soleus Air GM-PAC-12E1HP, GM-PAC-12E1 User Manual

0 (0)

GM-PAC-12E1

GM-PAC-12E1HP (WITH HEAT)

12,000 BTU Portable Air

Conditioner

Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner.

For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and serial number below:

Store Name: ____________________________________________________

Location: ______________________________________________________

Date Purchased: _________________________________________________

Serial Number (located on back of unit): ______________________________

IMPORTANT INSTRUCTIONS

Before installing and using your portable air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference.

1) Always place the unit on a level surface.

2) Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual.

3)Maintain at least 12 inches (50 cm) clearance space around this unit. Do not block or cover air inlet or outlet grilles.

4)The unit must be connected to a correctly grounded power supply.

5)Do not start or stop the unit by inserting or pulling out the power plug.

6)Do not use an adapter plug or extension cord.

7)Do not use the unit in the immediate surroundings of a bath, a shower or a swimming pool.

8)Do not insert anything into the air outlet. Do not obstruct air inlet or outlet grills unless instructed by this manual.

9)Do not let children play near this unit.

10)Always inspect the cord for signs of damage before use. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service technician.

11)When cleaning the unit, always turn the unit off and unplug the power cord.

2

PACKAGE CONTENTS

Portable Air Conditioner

Exhaust Hose (1)

Front Exhaust Hose Adapter (1)

Window Kit Adapter (1)

Rear Exhaust Hose Adapter (1)

Remote Control & AAA Batteries (2 batteries)

Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels)

Owner’s Manual

SPECIFICATIONS

The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F.

Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.

Power consumption is measured when the fan runs at the highest speed setting.

These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit.

If the environment temperature is higher than the max operating temperature or lower than the minimum operating temperature, the air conditioner may not work properly.

Dehumidifier mode works when ambient temperatures are between 61°F - 86°F

Air Conditioner mode operates up to an ambient temperature of 95°F.

Model

GM-PAC-12E1

GM-PAC-12E1HP (with Heat)

Power Supply (Ph/V/Hz)

1/115/60Hz

1/115/60Hz

Dehumidifying Capacity (Pints/Day)

81

81

Rated Cooling Capacity (BTU/h)

12,000

12,000

Rated Heating Capacity (BTU/h)

-

10,500

Cooling Power Input (Watts)

1465

1465

Heating Power Input (Watts)

-

1200

Rated Current Cooling (Amperage)

13

13

Rated Current Heating (Amperage)

-

10.6

Noise Level (dBA) - H/M/L

55/53/51

55/53/51

Air Flow - H/M/L (CFM)

235/205/175

235/205/175

Product Dimensions (W” x H” x D”)

17.75 x 33.125 x 17.125

17.75 x 33.125 x 17.125

Product Weight (Lbs)

80

80

Refrigerant Type

R-410A

R-410A

 

 

 

3

LCDI POWER CORD AND PLUG

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.

The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The cord will remain de-energized until the devise has been manually reset. This is intended to reduce the risk of a fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be considered a shock hazards if exposed. The cord shield must not be connected to ground or to any exposed metal.

The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:

1.Plug power cord into wall outlet

2.Press TEST Button, circuit should trip, cutting power to the air conditioner

3.Press RESET button for use

If a test is performed and the indicator light remains ON, current leakage has been detected. Do not use the air conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Powered by Gree Customer Service for troubleshooting recommendations.

RESET

TEST

WARNING:

1.DO NOT press the TEST button while the air conditioner is operating.

2.The TEST and RESET buttons should not be used as ONand OFFswitches.

3.The cord and plug are not intended to offer protection to externally connected loads or supply circuits.

4.The cord and plug are intended for indoor use only.

4

Soleus Air GM-PAC-12E1HP, GM-PAC-12E1 User Manual

PRODUCT DIAGRAM

Air Outlet &

Louvers

Carry Handle

Control Panel

Filter

 

Upper Air Intake

Location

 

 

 

 

 

 

Air Exhaust Vent

Lower Air Intake

Power Cord

5