Siemens CFFC1310-LP User Manual

0 (0)
Siemens CFFC1310-LP User Manual

English

Instruction Manual for Colour Fixed Dome Camera

Instructiehandleiding Fixed focus kleuren domecamera

Installationsanleitung Fixfokus-Dome-Farbkamera

Model number

Part Code

Modelnummer

Art. code

Typen-Nummer

Art.-Nr

CFFC1310-LP

2GF1184-8AC

CFFC1315-LP

2GF1184-8AA

Accessories / Accessoires / Zubehör

CFFA-TD CFFA-IC29 CFFA-IC37 CFFA-IC60 CFFA-IC12

2GF1086-8AA 2GF1086-8AB 2GF1086-8AK 2GF1086-8AF 2GF1086-8AE

Tinted Lower Dome / NL: Getinte dome / De: Getönte Kuppel

2.9 mm — Replacement Lens / NL: Vervangingslens / D: Ersatzlinse

3.7mm — Replacement Lens / NL: Vervangingslens / D: Ersatzlinse

6.0mm — Replacement Lens / NL: Vervangingslens / D: Ersatzlinse

12.0mm — Replacement Lens / NL: Vervangingslens / D: Ersatzlinse

Document / Document / Dokument

A24205-A336-R555

Edition / Editie / Ausgabe

Rev A.1

Supersedes / Vervangt / Ersetzt

-

 

 

A

10

1

9

 

2

97,5 mm

3

4

112 mm

5

6

7

B

12

11

13

C

2

3

4

8

Warning

To avoid electrical shock, do not open the cabinet. Refer servicing to qualified personnel only.

The CAUTION label shown above is attached to the dome. CAUTION: To reduce the risk of electric shock, do not remove cover (or back). No user-serviceable parts inside. Servicing should only be carried out by qualified service personnel.

Intended for indoor use only!

Waarschuwing

Open de behuizing niet, want dan loopt u het risico op een elektrische schok. Laat alle reparaties door gekwalificeerde technici uitvoeren.

De bovenstaande waarschuwingssticker is op de dome bevestigd.

LET OP: Om het risico op elektrische schokken te verkleinen, dient u de kap (of achterzijde) niet te verwijderen. In het apparaat bevinden zich geen onderdelen die u zelf kunt repareren. Laat elke vorm van onderhoud over aan gekwalificeerde technici.

Alleen geschikt voor binnentoepassingen!

Warnung

Zur Vermeidung von Elektroschocks darf das Gehäuse nicht geöffnet werden. Servicearbeiten dürfen nur von qualifiziertem Personal ausgeführt werden.

Der Warnhinweis oben ist an der Kuppel angebracht. VORSICHT: Um die Gefahr eines Elektroschocks zu verringern, darf das Gehäuse (oder die Rückseite) nicht entfernt werden. Im Inneren befinden sich keine benutzerseitig zu wartenden Teile. Servicearbeiten dürfen nur von qualifiziertem Kundendienstersonal ausgeführt werden.

Nur für den Einsatz im Innenbereich vorgesehen!

English

Package contents

Dome camera

1 BNC connection cable

1 service monitor cable

2 fixing screws

2 wall plugs

Fixing template

Installation and operating instructions (this document)

Dome camera parts

See figures A and B.

1.Cable entry holes

2.Unit casing

3.Inner liner

4.Dome casing

5.Mode setting DIP switches

6.V phase adjustment screw

7.Monitor output

8.Unit mounting holes

9.BNC connector

10.Power connector 11.Locking ring

12.Panning adjustment wheel 13.Axial ring

Installing the camera

Step 1: Connecting the cables

1.Connect the BNC cable to the BNC connector (9).

2.Connect the power supply cable to the power connector (10).

Use a 24 V AC or 12 V DC power supply.

Caution

If using a DC supply, make sure the polarity is correct. Incorrect connection may cause malfunction and/or damage to the video camera.

3.Guide the cables through the cable entry holes (1).

Step 2: Mounting the camera

1.Place the template on the mounting surface and mark the holes.

2.Drill two holes as marked.

3.Insert the wall plugs into the holes.

4.Fasten the unit with the screws provided.

Step 3: Adjusting the camera position

1.Hold the lens so that it does not rotate.

2.Loosen the locking ring (11) and panning adjustment wheel (12).

Caution

Do not loosen the locking ring without holding the lens in place; otherwise, the lens may rotate with the locking ring and the cable may twist.

3. Turn the axial ring (13) in the desired direction.

Note

If the camera does not rotate smoothly, loosen the locking ring completely. The locking ring has an internal stop and will not come off.

Caution

Do not turn the lens more than 360° as this may cause internal cables to disconnect or break.

4.Using the axial ring, carefully adjust the image to the desired angle of view.

5.Lightly tighten the locking ring (11) and panning adjustment wheel (12)

6.Hold the lens and fully retighten the locking ring (11) and panning adjustment wheel (12).

Optional settings

Adjust the phase difference between cameras (use V Phase adjustment screw (6).

Set the DIP switches (5) to activate or deactivate the following features:

Backlight compensation (BLC)

Automatic gain control (AGC). Automatically adjusts the picture to suit ambient brightness

Automatic electronic shutter (DC/AES). Automatically adjusts the picture to suit the brightness of the subject.

Caution

Do not turn the DC/AES Mode switch to on otherwise the electronic shutter speed will be permanently set to 1/60(EIA) or 1/50(CCIR).

Line Lock (LL).

Set camera synchronisation to internal (OFF) or line lock (ON). Line lock is only available with a 24 V AC supply.

Step 4: Attaching the dome to the unit

See figure C.

Note

Use a soft lint-free cloth to wipe the dome cover clean and remove fingerprints.

1.Clean the joint surfaces of the unit.

2.Place the inner liner on the unit.

3.Place the dome on the unit.

4.Turn the dome clockwise and lock the cover in place.

General guidelines

Operation and storage

Avoid facing the camera directly toward very bright objects (such as light fittings) for an extended period.

Do not operate or store the unit in the following locations:

Extremely hot or cold places.

Close to sources of strong magnetism.

Close to sources of powerful electromagnetic radiation, such as radios or TV transmitters.

In humid or excessively dusty places.

Where exposed to mechanical vibration.

Close to fluorescent lamps or objects that reflect light.

Under unstable or flickering light sources.

Cleaning

Use a soft, dry cloth to remove fingerprints or dust from the dome.

If the dome is very dirty, use a small amount of mild detergent on a damp cloth for cleaning. Ensure the dome is dry before attaching the dome to the unit.

Caution

Do not use volatile solvents such as alcohol, benzene or thinners. These solvents may damage the surface.

Transportation

Use the original packing material or materials of equal quality.

CCD characteristics

The following conditions may be observed when using a CCD camera. These are inherent to the design and do not stem from any fault within the camera itself.

Vertical smear: This phenomenon occurs when viewing a very bright object.

Patterned noise: This is a fixed pattern which may appear over the entire monitor screen when the camera is operated at a high temperature.

Jagged picture: When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged.

Specifications

General

 

Power requirement......

12 V DC or 24 V AC

 

(Min. 5 W)

Power consumption ....

3,5 W (max.)

Operating temperature-10 to +50°C, 90% RH max.

Storage temperature

...-20 to +60°C, 70% RH max.

External dimensions....

112 x 97.5 mm

Weight.........................

Approx. 0.29 kg

Unit material................

ABS (30%) and

 

polycarbonate (70%)

Dome material.............

Polycarbonate

Imaging system

 

Imaging device............

Interline transfer 1/3 inch

 

CCD

Effective picture elements

 

CFFC1310-LP (Std. Res.)

 

PAL: 500(H) * 582(V)

 

CFFC1315-LP (High Res.)

 

PAL: 752(H) * 582(V)

TV system ...................

PAL: 2:1 Interlace,

 

15.750 kHz horizontal,

 

50 Hz vertical

Optical system and other specifications

Focal length ................

f=3.7 mm

Maximum relative aperture

 

F2.0

Synchronisation system

 

Internal or Line lock (24 V

 

AC only)

Horizontal resolution ...

480 TV lines — High

 

Resolution model

 

330 TV lines — Std

 

Resolution model

Minimum illumination ..

0.56 lx — High Resolution

 

model

 

0.31 lx — Std Resolution

 

model

 

(AGC ON, more than 50%

 

of image output r = 0.45,

 

without dome cover)

Video output................

1.0 Vp-p 75 Ohm

Video S/N ratio............

More than 50 dB (AGC

 

OFF, Weighted)

White balance .............

Automatic (2500°K -

 

10000°K)

AGC ............................

ON/OFF switchable

BLC .............................

ON (Center measured) /

 

OFF switchable

Information

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area may cause harmful interference in which case the user will be required to correct the interference at his own expense.

© 2003 Siemens Building Technologies: Fire and Security Products

Data and design subject to change without notice.

Loading...
+ 2 hidden pages