Sanyo CH1852, CH0952, KHS1852-S User Manual

0 (0)

TECHNICAL & SERVICE MANUAL

KHS0951 / CH0951

KHS1251 / CH1251

KHS1852 / CH1852

FILE NO.

Destination: U.S.A.

SPLIT SYSTEM AIR CONDITIONER

Indoor Model No.

Product Code No.

 

 

KHS0951

1 852 069 13

 

 

KHS1251

1 852 069 14

 

 

KHS1852-S

1 852 069 15

 

 

Outdoor Model No.

Product Code No.

 

 

CH0951

1 852 069 16

 

 

CH1251

1 852 069 17

 

 

CH1852

1 852 069 18

 

 

Indoor Unit

Outdoor Unit

KHS0951 KHS1251

CH0951 CH0952

KHS1852

CH1852

REFERENCE NO. SM700447

W

IMPORTANT!

Please Read Before Starting

This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently.

For safe installation and trouble-free operation, you must:

Carefully read this instruction booklet before beginning.

Follow each installation or repair step exactly as shown.

Observe all local, state, and national electrical codes.

Pay close attention to all warning and caution notices given in this manual.

This symbol refers to a hazard or

WARNING unsafe practice which can result in severe personal injury or

death.

This symbol refers to a hazard or

CAUTION unsafe practice which can result in personal injury or product or

property damage.

If Necessary, Get Help

These instructions are all you need for most installation sites and maintenance conditions. If you require help for a special problem, contact our sales/service outlet or your certified dealer for additional instructions.

In Case of Improper Installation

The manufacturer shall in no way be responsible for improper installation or maintenance service, including failure to follow the instructions in this document.

SPECIAL PRECAUTIONS

When Wiring

WARNING

ELECTRICAL SHOCK CAN CAUSE SEVERE PERSONAL INJURY OR DEATH. ONLY A QUALIFIED, EXPERIENCED ELECTRICIAN SHOULD ATTEMPT TO WIRE THIS SYSTEM.

Do not supply power to the unit until all wiring and tubing are completed or reconnected and checked.

Highly dangerous electrical voltages are used in this system. Carefully refer to the wiring diagram and these instructions when wiring. Improper connections and inadequate grounding can cause accidental injury or death.

Ground the unit following local electrical codes.

Connect all wiring tightly. Loose wiring may cause overheating at connection points and a possible fire hazard.

When Transporting

Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your fingers.

When Installing…

…In a Ceiling or Wall

Make sure the ceiling/wall is strong enough to hold the unit’s weight. It may be necessary to construct a strong wood or metal frame to provide added support.

…In a Room

Properly insulate any tubing run inside a room to prevent “sweating” that can cause dripping and water damage to walls and floors.

…In Moist or Uneven Locations

Use a raised concrete pad or concrete blocks to provide a solid, level foundation for the outdoor unit. This prevents water damage and abnormal vibration.

…In an Area with High Winds

Securely anchor the outdoor unit down with bolts and a metal frame. Provide a suitable air baffle.

…In a Snowy Area (for Heat Pump-type Systems)

Install the outdoor unit on a raised platform that is higher than drifting snow. Provide snow vents.

When Connecting Refrigerant Tubing

Use the flare method for connecting tubing.

Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.

Check carefully for leaks before starting the test run.

When Servicing

Turn the power OFF at the main power box (mains) before opening the unit to check or repair electrical parts and wiring.

Keep your fingers and clothing away from any moving parts.

Clean up the site after you finish, remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced.

Others

CAUTION

Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.

Confirm upon completing installation that no refrigerant gas is leaking. If escaped gas comes in contact with a stove, gas water heater, electric room heater or other heat source, it can produce dangerously toxic gas.

i

Table of Contents

 

 

 

Page

1.

OPERATING RANGE ................................................................................................................

1

2.

SPECIFICATIONS

 

 

2-1.

Unit Specifications ............................................................................................................

2

 

2-2.

Major Component Specifications......................................................................................

5

 

2-3.

Other Component Specifications......................................................................................

11

3.

DIMENSIONAL DATA

 

 

3-1.

Unit ...................................................................................................................................

14

4.

REFRIGERANT FLOW DIAGRAM

 

 

4-1.

Refrigerant Flow Diagram.................................................................................................

18

5.

PERFORMANCE DATA

 

 

5-1.

Performance Charts .........................................................................................................

19

 

5-2. Air Throw Distance Charts ...............................................................................................

22

 

5-3.

Cooling Capacity ..............................................................................................................

25

 

5-4.

Heating Capacity ..............................................................................................................

29

6.

ELECTRICAL DATA

 

 

6-1.

Electrical Characteristics ..................................................................................................

30

 

6-2.

Electric Wiring Diagrams ..................................................................................................

33

7.

INSTALLATION INSTRUCTIONS

 

 

7-1.

Installation Site Selection .................................................................................................

42

 

7-2. Remote Control Unit Installation Position .........................................................................

44

 

7-3.

Address Switches .............................................................................................................

45

 

7-4. Recommended Wire Length and Diameter ......................................................................

46

8.

FUNCTION

 

 

8-1.

Room Temperature Control ..............................................................................................

47

 

8-2.

Dry Operation (Dehumidification) .....................................................................................

49

 

8-3. Automatic Switching between Cooling and Heating .........................................................

49

 

8-4.

Freeze Prevention (Cooling) .............................................................................................

50

 

8-5.

Overload Prevention (Heating) .........................................................................................

50

 

8-6. Cold draft Prevention (Heating) ........................................................................................

51

 

8-7.

Defrosting Operation (Heating).........................................................................................

52

 

8-8. Low Temperature Cutff (Heating) .....................................................................................

53

9.

TROUBLESHOOTING

 

 

9-1. Check before and after troubleshooting............................................................................

54

 

9-2. Air conditioner does not operate.......................................................................................

55

 

9-3. Some part of air conditioner does not operate. ................................................................

59

 

9-4. Air conditioner operates, but abnormalities are observed. ...............................................

61

 

9-5.

If a sensor is defective. .....................................................................................................

63

ii

10.

CHECKING ELECTRICAL COMPONENTS

 

 

10-1.

Measurement of Insulation Resistance ............................................................................

64

 

10-2.

Checking Continuity of Fuse on PCB Ass'y......................................................................

65

 

10-3.

Checking Motor Capacitor ................................................................................................

65

11.

ARRANGEMENT OF ELECTRICAL COMPONENT.................................................................

66

APPENDIX INSTRUCTION MANUAL

iii

1. OPERATING RANGE

 

Temperature

Indoor Air Intake Temp.

Outdoor Air Intake Temp.

 

 

 

 

Cooling

Maximum

95°F D.B. / 71°F W.B.

115°F D.B.

 

 

 

Minimum

67°F D.B. / 57°F W.B.

67°F D.B.

 

 

 

 

 

Heating

Maximum

80°F D.B. / 67°F W.B.

75°F D.B. / 65°F W.B.

 

 

 

Minimum

— D.B. / — W.B.

17°F D.B. / 15°F W.B.

 

 

 

 

 

1

2. SPECIFICATIONS

2-1. Unit Specifications

(1) Indoor unit

KHS0951

 

 

 

 

 

 

 

Outdoor unit

CH0951

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

 

115V 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

BTU/h

 

9,100

 

10,900

 

 

 

 

 

kW

 

2.67

 

3.19

 

 

 

 

 

 

 

 

 

Air circulation (High)

 

ft3/min (m3/min)

 

 

270 (7.65)

 

Moisture removal (High)

 

 

Pints/h

 

2.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

V

 

 

103 – 126

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

 

8.5

 

8.4

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

 

890

 

890

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

 

91

 

92

 

 

 

 

 

 

 

 

 

 

SEER (HSPF)

 

 

BTU/W

 

11.0

 

(6.8)

 

 

 

 

 

 

 

 

 

Compressor locked rotor amperes

 

A

 

 

49

 

 

 

 

 

 

 

 

 

Heater element

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

Wireless remote control unit

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

ON / OFF 12 hours, 1-hour OFF

 

 

 

 

 

 

 

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

 

 

 

 

 

 

 

Airflow direction (Indoor)

Horizontal

 

 

Manual

 

 

 

 

 

Vertical

 

 

Auto

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

Washable

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

lb. (kg)

 

 

2.65 (1.20)

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

Operation sound

Indoor: Hi / Me / Lo dB-A

 

 

38 / 34 / 32

 

 

 

Outdoor: Hi

 

dB-A

 

 

48

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare

 

 

 

 

 

 

 

 

Max allowable tubing length at shipment

ft. (m)

 

 

25 (7.5)

 

 

 

 

 

 

 

 

 

Refrigerant tubing

Narrow tube

inch (mm)

 

 

1/4 (6.35)

 

diameter

 

Wide tube

 

inch (mm)

 

 

3/8 (9.52)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

 

10-5/8 (270)

 

21-1/4 (540)

 

 

 

Width

 

inch (mm)

 

31-11/16 (805)

 

31-1/2 (800)

 

 

 

Depth

 

inch (mm)

 

6-31/32 (177)

 

11-13/32 (290)

 

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

 

9-13/16 (249)

 

23-31/32 (609)

 

 

 

Width

 

inch (mm)

 

33-21/32 (855)

 

38-5/8 (981)

 

 

 

Depth

 

inch (mm)

 

13-5/16 (338)

 

16-3/16 (411)

 

 

 

 

 

 

 

 

 

 

 

Weight

 

Net

 

lb. (kg)

 

17.6 (8.0)

 

75.0 (34)

 

 

 

Shipping

 

lb. (kg)

 

22.0 (10.0)

 

83.8 (38)

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

 

2.51 (0.071)

 

8.67 (0.246)

Remarks: Rating conditions are

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

2

(2) Indoor unit

KHS1251

 

 

 

 

 

 

 

Outdoor unit

CH1251

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

 

115V 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

BTU/h

 

11,700

 

12,500

 

 

 

 

 

kW

 

3.43

 

3.66

 

 

 

 

 

 

 

 

 

Air circulation (High)

 

ft3/min (m3/min)

 

 

330 (9.35)

 

Moisture removal (High)

 

 

Pints/h

 

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

V

 

 

103 – 126

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

 

10.5

 

10.3

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

 

1,200

 

1,170

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

 

99

 

99

 

 

 

 

 

 

 

 

 

 

SEER (HSPF)

 

 

BTU/W

 

10.2

 

(6.8)

 

 

 

 

 

 

 

 

 

Compressor locked rotor amperes

 

A

 

 

60

 

 

 

 

 

 

 

 

 

Heater element

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

Wireless remote control unit

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

ON / OFF 12 hours, 1-hour OFF

 

 

 

 

 

 

 

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

 

 

 

 

 

 

 

Airflow direction (Indoor)

Horizontal

 

 

Manual

 

 

 

 

 

Vertical

 

 

Auto

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

Washable

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

lb. (kg)

 

 

2.76 (1.25)

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

Operation sound

Indoor: Hi / Me / Lo dB-A

 

 

41 / 38 / 34

 

 

 

Outdoor: Hi

 

dB-A

 

 

48

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare

 

 

 

 

 

 

 

 

Max allowable tubing length at shipment

ft. (m)

 

 

25 (7.5)

 

 

 

 

 

 

 

 

 

Refrigerant tubing

Narrow tube

inch (mm)

 

 

1/4 (6.35)

 

diameter

 

Wide tube

 

inch (mm)

 

 

1/2 (12.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

 

10-5/8 (270)

 

21-1/4 (540)

 

 

 

Width

 

inch (mm)

 

31-11/16 (805)

 

31-1/2 (800)

 

 

 

Depth

 

inch (mm)

 

6-31/32 (177)

 

11-13/32 (290)

 

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

 

9-13/16 (249)

 

23-31/32 (609)

 

 

 

Width

 

inch (mm)

 

33-21/32 (855)

 

38-5/8 (981)

 

 

 

Depth

 

inch (mm)

 

13-5/16 (338)

 

16-3/16 (411)

 

 

 

 

 

 

 

 

 

 

 

Weight

 

Net

 

lb. (kg)

 

17.6 (8.0)

 

83.8 (38)

 

 

 

Shipping

 

lb. (kg)

 

22.0 (10.0)

 

92.6 (42)

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

 

2.51 (0.071)

 

8.67 (0.246)

Remarks: Rating conditions are

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

3

(3) Indoor unit

KHS1852

 

 

 

 

 

 

 

Outdoor unit

CH1852

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

Voltage Rating

 

 

 

 

 

230 / 208V 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

 

 

BTU/h

 

17,000 / 16,500

 

19,000 / 18,500

 

 

 

 

 

kW

 

4.98 / 4.84

 

5.75 / 5.42

 

 

 

 

 

 

 

 

 

Air circulation (High)

 

ft3/min (m3/min)

 

 

390 (11.1)

 

Moisture removal (High)

 

 

Pints/h

 

4.5 / 4.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating

 

 

 

 

 

Cooling

 

Heating

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

V

 

 

187 – 253

 

 

 

 

 

 

 

 

 

Running amperes

 

 

A

 

7.6 / 8.1

 

7.1 / 7.5

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

 

1,700 / 1,660

 

1,610 / 1,540

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

 

99

 

99

 

 

 

 

 

 

 

 

 

 

SEER (HSPF)

 

 

BTU/W

 

10.5

 

(6.8)

 

 

 

 

 

 

 

 

 

Compressor locked rotor amperes

 

A

 

 

43

 

 

 

 

 

 

 

 

 

Heater element

 

 

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls / Temperature control

 

 

 

Microprocessor / I.C. thermostat

 

 

 

 

 

 

 

 

 

Control unit

 

 

 

 

Wireless remote control unit

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

ON / OFF 12 hours, 1-hour OFF

 

 

 

 

 

 

 

 

Fan speeds

Indoor / Outdoor

 

 

3 and Auto / 1 (Hi)

 

 

 

 

 

 

 

 

Airflow direction (Indoor)

Horizontal

 

 

Manual

 

 

 

 

 

Vertical

 

 

Auto

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

 

 

 

Washable

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

 

Refrigerant / Amount charged at shipment

lb. (kg)

 

 

3.97 (1.80)

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

Operation sound

Indoor: Hi / Me / Lo dB-A

 

 

41 / 38 / 36

 

 

 

Outdoor: Hi

 

dB-A

 

 

52

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare

 

 

 

 

 

 

 

 

Max allowable tubing length at shipment

ft. (m)

 

 

25 (7.5)

 

 

 

 

 

 

 

 

 

Refrigerant tubing

Narrow tube

inch (mm)

 

 

1/4 (6.35)

 

diameter

 

Wide tube

 

inch (mm)

 

 

5/8 (15.88)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions & Weight

 

 

 

 

Indoor Unit

 

Outdoor Unit

 

 

 

 

 

 

 

 

 

 

Unit dimensions

Height

 

inch (mm)

 

11-7/32 (285)

 

24-19/32 (625)

 

 

 

Width

 

inch (mm)

 

39-3/16 (995)

 

34-21/32 (880)

 

 

 

Depth

 

inch (mm)

 

7-23/32 (196)

 

12-19/32 (320)

 

 

 

 

 

 

 

 

 

 

Package dimensions

Height

 

inch (mm)

 

10-7/8 (276)

 

27-15/16 (710)

 

 

 

Width

 

inch (mm)

 

42-1/8 (1,070)

 

40-9/16 (1,030)

 

 

 

Depth

 

inch (mm)

 

14-9/32 (363)

 

16-3/16 (411)

 

 

 

 

 

 

 

 

 

 

 

Weight

 

Net

 

lb. (kg)

 

26.5 (12.0)

 

108 (49)

 

 

 

Shipping

 

lb. (kg)

 

33 (15.0)

 

117 (53)

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

 

cu.ft (m3)

 

3.78 (0.107)

 

10.6 (0.301)

Remarks: Rating conditions are

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

 

 

 

 

 

 

 

 

Cooling: Indoor air temperature

80°F D.B. / 67°F W.B.

 

 

 

 

 

Outdoor air temperature

95°F D.B. / 75°F W.B.

 

 

 

 

Heating: Indoor air temperature

70°F D.B.

 

 

 

 

 

Outdoor air temperature

47°F D.B. / 43°F W.B.

 

 

 

4

2-2. Major Component Specifications

2-2-1. Indoor Unit

(1) Indoor unit KHS0951

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-KHS095A, POW-KHS095B

 

Controls

 

 

Microprocessor

 

 

 

 

 

 

Control circuit fuse

 

 

AC 115V – 3A

 

 

 

 

 

 

 

 

 

Remote Control Unit

 

 

RCS-1HS2U

 

 

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

Type

 

 

Cross-flow

 

 

 

 

 

Q’ty … Dia. and length

inch (mm)

1 … ø 3-3/4 / L24-9/32 (ø 95 / L617)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

KFV4-21H1PA … 1P

 

 

 

 

 

 

 

Nominal output

 

W

 

20

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU

– BRN: 100.9

 

 

 

 

BLU

– PNK: 127.5

 

 

 

 

 

 

 

Run capacitor

 

µF

 

3.5

 

 

 

VAC

 

180

 

 

 

 

 

 

 

 

 

 

 

 

Flap Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Stepping motor

 

 

 

 

 

 

Model

 

 

MP24GA1

 

 

 

 

 

 

 

Rating

 

 

 

DC12V

 

 

 

 

 

Coil resistance (ambient temp. 77°F (25°C))

Ω

WHT – BLU (respectively 4 wires): 380 ± 7%

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

Rows

 

 

 

2

 

 

 

 

 

 

Fin pitch

inch (mm)

 

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

1.40 (0.130)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

5

(2) Indoor unit KHS1251

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-KHS125A / POW-KHS095B

 

Controls

 

 

Microprocessor

 

 

 

 

 

 

Control circuit fuse

 

 

AC 115V – 3A

 

 

 

 

 

 

 

 

 

Remote Control Unit

 

 

RCS-1HS2U

 

 

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Cross-flow

 

 

 

 

 

Q’ty … Dia. and length

inch (mm)

1 … ø 3-3/4 / L24-9/32 (ø 95 / L617)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

KFV4-21H1PA … 1P

 

 

 

 

 

 

 

Nominal output

 

W

 

20

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU

– BRN: 100.9

 

 

 

 

BLU

– PNK: 127.5

 

 

 

 

 

 

 

Run capacitor

 

µF

 

3.5

 

 

 

VAC

 

180

 

 

 

 

 

 

 

 

 

 

 

 

Flap Motor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Stepping motor

 

 

 

 

 

 

Model

 

 

MP24GA1

 

 

 

 

 

 

 

Rating

 

 

 

DC12V

 

 

 

 

 

Coil resistance (ambient temp. 77°F (25°C))

Ω

WHT – BLU (respectively 4 wires): 380 ± 7%

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

 

Rows

 

 

 

2

 

 

 

 

 

 

Fin pitch

inch (mm)

 

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

1.40 (0.130)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

6

(3) Indoor unit KHS1852

Control PCB

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-KHS1852

 

Controls

 

 

Microprocessor

 

 

 

 

 

 

Control circuit fuse

 

 

AC 208 / 230V – 3A

 

 

 

 

 

 

 

 

 

Remote Control Unit

 

 

RCS-1HS2U

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Cross-flow

 

 

 

 

 

Q’ty … Dia. and length

inch (mm)

1 … ø 3-15/32 / L29-3/8 (ø88 / L746)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

UF4-31D6P-S … 1P

 

 

 

 

 

 

Nominal output

 

W

30

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

WHT – BRN: 204.2

 

 

 

 

WHT – PNK: 158.3

 

 

 

 

 

 

Run capacitor

 

µF

2.0

 

 

 

VAC

440

 

 

 

 

 

 

 

 

 

 

Flap Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Stepping motor

 

 

 

 

 

 

Model

 

 

MP24GA2

 

 

 

 

 

 

Rating

 

 

DC12V

 

 

 

 

 

Coil resistance (ambient temp. 77°F (25°C))

Ω

Each terminals (1–2, 1–3, 1–4, 1–5) : 400 ± 7%

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

Rows

 

 

2

 

 

 

 

 

Fin pitch

inch (mm)

1/16 (1.3)

 

 

 

 

 

 

Face area

 

ft2 (m2)

1.68 (0.156)

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

7

2-2-2. Outdoor Unit

(1) Outdoor unit CH0951

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-CH095

 

Controls

 

 

 

 

 

 

 

 

 

Control circuit fuse

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

Compressor model

 

 

C-1R75H2R

 

 

 

 

 

 

 

Nominal output

 

W

750

 

 

 

 

 

 

 

Compressor oil … Amount

 

cc

SUNISO 4GSD-T … 350

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

C – R: 0.841

 

 

 

 

 

C – S: 2.831

 

 

 

 

 

 

 

Safety devices Type

 

 

External (OLR)

 

 

 

 

 

 

 

 

Overload relay

 

 

MRA99111-9200

 

 

 

 

 

 

Run capacitor

 

µF

40

 

 

 

 

VAC

400

 

 

 

 

 

 

Crank case heater

 

 

115V, 20W

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Propeller

 

 

 

 

 

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ø 420)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

UE6-21BA1PA … 1

 

 

 

 

 

 

No. of poles … rpm (115V, High)

 

 

6 … 630

 

 

 

 

 

 

Nominal output

 

W

20

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU – BRN: 45.3

 

 

 

 

 

BLU – PNK: 50.5

 

 

 

 

 

 

Run capacitor

 

µF

8

 

 

 

 

VAC

220

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

Rows

 

 

2

 

 

 

 

 

Fin pitch

inch (mm)

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

3.37 (0.313)

 

 

 

 

External Finish

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

8

(2) Outdoor unit CH1251

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-CH095

 

Controls

 

 

 

 

 

 

 

 

 

Control circuit fuse

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

Compressor model

 

 

C-R95H2E

 

 

 

 

 

 

 

Nominal output

 

W

950

 

 

 

 

 

 

 

Compressor oil … Amount

 

cc

SUNISO 4GSD-T … 570

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

C – R: 0.576

 

 

 

 

 

C – S: 3.070

 

 

 

 

 

 

 

Safety devices Type

 

 

External (OLR)

 

 

 

 

 

 

 

 

Overload relay

 

 

MRA98693-9200

 

 

 

 

 

 

Run capacitor

 

µF

40

 

 

 

 

VAC

400

 

 

 

 

 

 

Crank case heater

 

 

115V, 20W

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Propeller

 

 

 

 

 

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ø 420)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

UE6-21BA1PA … 1

 

 

 

 

 

 

No. of poles … rpm (115V, High)

 

 

6 … 630

 

 

 

 

 

 

Nominal output

 

W

20

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

BLU – BRN: 45.3

 

 

 

 

 

BLU – PNK: 50.5

 

 

 

 

 

 

Run capacitor

 

µF

8

 

 

 

 

VAC

220

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

Rows

 

 

2

 

 

 

 

 

Fin pitch

inch (mm)

1/16 (1.4)

 

 

 

 

 

 

Face area

 

ft2 (m2)

3.37 (0.313)

 

 

 

 

External Finish

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

9

(3) Outdoor unit CH1852

Control PCB

 

 

 

 

 

 

 

 

 

 

Part No.

 

 

POW-CH095

 

Controls

 

 

 

 

 

 

 

 

 

Control circuit fuse

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

 

 

 

 

 

Type

 

 

Rotary (Hermetic)

 

 

 

 

 

 

 

Compressor model

 

 

C-R132H6D

 

 

 

 

 

 

 

Nominal output

 

W

1,300

 

 

 

 

 

 

 

Compressor oil … Amount

 

cc

SUNISO 4GSD-T … 500

 

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

C – R: 1.442

 

 

 

 

 

C – S: 2.430

 

 

 

 

 

 

 

Safety devices Type

 

 

External (OLR)

 

 

 

 

 

 

 

 

Overload relay

 

 

MRA99117-9200

 

 

 

 

 

 

Run capacitor

 

µF

35

 

 

 

 

VAC

400

 

 

 

 

 

 

Crank case heater

 

 

230V, 20W

 

 

 

 

 

 

 

 

 

Fan & Fan Motor

 

 

 

 

 

 

 

 

 

Type

 

 

Propeller

 

 

 

 

 

Q’ty … Dia. and length

inch. (mm)

1 … 16-17/32 (ø 420)

 

 

 

 

 

 

Fan motor model … Q’ty

 

 

KFG6-51E6PA … 1

 

 

 

 

 

 

No. of poles … rpm (230V, High)

 

 

6 … 830

 

 

 

 

 

 

Nominal output

 

W

50

 

 

 

 

 

Coil resistance (ambient temp. 68°F (20°C))

Ω

WHT – BRN: 102

 

 

 

 

 

PNK – WHT: 199

 

 

 

 

 

 

Run capacitor

 

µF

2

 

 

 

 

VAC

440

 

 

 

 

 

 

 

 

 

 

 

Heat Exchanger Coil

 

 

 

 

 

 

 

 

 

Coil

 

 

Aluminum plate fin / Copper tube

 

 

 

 

 

 

Rows

 

 

2

 

 

 

 

 

Fin pitch

inch (mm)

1/16 (1.6)

 

 

 

 

 

 

Face area

 

ft2 (m2)

5.13 (0.477)

 

 

 

 

External Finish

 

 

Acrylic baked-on enamel finish

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

10

2-3. Other Component Specifications

2-3-1. Indoor Unit

(1) Indoor unit

KHS0951

 

 

 

 

Transformer

 

ATR-T4

 

 

 

Rating

Primary

AC 115V, 60Hz

 

Secondary

19V, 0.5A

 

 

 

 

Thermistor (Coil sensor)

DTN-TKS131B

 

 

 

Resistance

32°F (0°C) 15 ± 2%

 

 

 

 

Thermistor (Room sensor in lamp Ass’y)

DTN-TKS134B

 

 

 

Resistance

77°F (25°C) 5 ± 3%

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

(2) Indoor unit

KHS1251

 

 

 

 

Transformer

 

ATR-T4

 

 

 

Rating

Primary

AC 115V, 60Hz

 

Secondary

19V, 0.5A

 

 

 

 

 

Thermistor (Coil sensor)

DTN-TKS131B

 

 

 

Resistance

32°F (0°C) 15 ± 2%

 

 

 

 

Thermistor (Room sensor in lamp Ass’y)

DTN-TKS134B

 

 

 

Resistance

77°F (25°C) 5 ± 3%

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

(3) Indoor unit

KHS1852

 

 

 

 

Transformer

 

ATR-T5

 

 

 

Rating

Primary

AC 230V, 60Hz

 

Secondary

19V, 0.5A

 

 

 

 

 

Thermistor (Coil sensor)

DTN-TKS131B

 

 

 

Resistance

32°F (0°C) 15 ± 2%

 

 

 

 

Thermistor (Room sensor)

DTN-TKS142B

 

 

 

Resistance

77°F (25°C) 5 ± 3%

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE.

11

2-3-2. Outdoor Unit

(1) Outdoor Unit

CH0951

 

 

 

 

 

 

 

 

 

PTC Thermistor

 

 

PS2A E20-470

 

Resistance

Ω

at 77°F (25°C)

 

47 ± 25%

 

 

 

 

 

 

 

 

 

 

 

Power Relay (PR)

 

DFU24D1-F

 

Coil rating

 

 

 

DC 24V

 

Coil resistance

Ω

at 68°F (20°C)

650 ± 10%

 

Contact rating

 

 

AC 250V, 20A

 

 

 

 

 

 

 

 

 

 

Thermostat (Defrost thermo. 23D)

TRS02-12MSR

 

Operating temp.

°F (°C)

ON

54 ± 4°F (12 ± 2°C)

 

 

 

 

Diff.

14 deg (8 deg). below

 

 

 

 

 

 

 

 

 

 

Thermostat (Low temp. cutoff 23A)

TRS02-M13MSR436

 

Operating temp.

°F (°C)

OFF (OPEN) : 5°F (–15°C)

 

 

 

 

ON (CLOSE) : 17°F (–8.3°C)

 

 

 

 

 

4-way Valve (Solenoid coil)

 

LB69001 (Coil), VH79102 (Valve)

 

 

 

Coil rating

 

 

AC 120V, 6W

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

(2) Outdoor Unit

CH1251

 

 

 

 

 

 

 

 

 

PTC Thermistor

 

 

PS2A E20-470

 

Resistance

Ω

at 77°F (25°C)

 

47 ± 25%

 

 

 

 

 

 

 

 

 

 

 

Power Relay (PR)

 

DFU24D1-F

 

Coil rating

 

 

 

DC 24V

 

Coil resistance

Ω

at 68°F (20°C)

650 ± 10%

 

Contact rating

 

 

AC 250V, 20A

 

 

 

 

 

 

 

 

 

 

Thermostat (Defrost thermo. 23D)

TRS02-12MSR

 

Operating temp.

°F (°C)

ON

54 ± 4°F (12 ± 2°C)

 

 

 

 

Diff.

14 deg (8 deg). below

 

 

 

 

 

 

 

 

 

 

Thermostat (Low temp. cutoff 23A)

TRS02-M13MSR436

 

Operating temp.

°F (°C)

OFF (OPEN) : 5°F (–15°C)

 

 

 

 

ON (CLOSE) : 17°F (–8.3°C)

 

 

 

 

 

4-way Valve (Solenoid coil)

 

LB69001 (Coil), V26-9201 (Valve)

 

 

 

Coil rating

 

 

AC 120V, 6W

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

12

(3) Outdoor Unit

CH1852

 

 

 

 

 

 

 

 

Power Relay (PR)

 

DFU24D1-F

 

Coil rating

 

 

 

DC 24V

 

Coil resistance

Ω

at 68°F (20°C)

650 ± 10%

 

Contact rating

 

 

AC 250V, 20A

 

 

 

 

 

 

 

 

 

 

Thermostat (Defrost thermo. 23D)

TRS02-12MSR

 

Operating temp.

°F (°C)

ON

54 ± 4°F (12 ± 2°C)

 

 

 

 

Diff.

14 deg (8 deg). below

 

 

 

 

 

 

 

 

 

 

Thermostat (Low temp. cutoff 23A)

TRS02-M13MSR436

 

Operating temp.

°F (°C)

OFF (OPEN) : 5°F (–15°C)

 

 

 

 

ON (CLOSE) : 17°F (–8.3°C)

 

 

 

 

 

4-way Valve (Solenoid coil)

 

LB69005 (Coil), V26-9201 (Valve)

 

 

 

Coil rating

 

 

AC 208-230V, 6W

 

 

 

 

 

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

13

3. DIMENSIONAL DATA

3-1. Unit

3-1-1. Indoor Unit

(1) Indoor unit KHS0951 / KHS1251

31-11/16 (805)

10-5/8 (270)

Drain hose ø23/32 (18)

1-5/8 (41.0)

1-5/8 (41.0)

3-29/32

2-5/16

(99.5)

(58.5)

 

Narrow tube ø1/4 (6.35)

Center of tubing

Wide tube*

hole (2 places)

6-31/32 (177)

Remote control unit

6-7/32

(172.5)

2-2/5

25/32

(61)(18.5)

*

KHS0951 ø3/8 (9.52)

KHS1251 ø1/2 (12.7)

Unit: inch (mm)

14

Sanyo CH1852, CH0952, KHS1852-S User Manual

(2) Indoor unit KHS1852

39-3/16 (995)

 

11-7/32 (285)

 

 

 

7-23/32 (196) 1/8 (3)

 

 

Remote control unit

-25/32 (45)

-25/32 (45)

6-7/32 (172.5)

1

1

 

 

 

 

2-2/5

25/32

(147.5)

 

(147.5)

(61)

(18.5)

 

 

 

5-13/16

Center of tubing

5-13/16

 

 

 

hole (2 places)

Drain hose ø18

 

 

 

Narrow tube ø6.35 (1/4")

 

 

 

Wide tube ø15.88 (5/8")

 

 

Unit : inch (mm)

15

3-1-2. Outdoor Unit

(1) Outdoor unit CH0951 / CH1251

Air intake

2-ø15/32"

23-15/16" 3-25/32"

11-13/32"

12-7/16"

15/32"

Air discharge

31-2/1"

21-1/4"

5/8"

2-5/32"

3-7/16"

11-13/32"

Narrow tube service valve

ø6.35 (1/4")

Wide tube service valve*

*

CH0951 ø3/8 (9.52)

CH1251 ø1/2 (12.7)

Unit: inch (mm)

16

(2) Outdoor unit CH1852

Air intake

4-ø15/32"

23-15/16" 5-11/32"

12-7/32"

13-5/32"

15/32"

Air discharge

34-21/32"

21-19/32"

5/8"

2-5/32"

3-7/16"

12-19/32"

Narrow tube service valve

ø6.35 (1/4")

Wide tube service valve ø15.88 (5/8")

Unit: inch (mm)

17

4. REFRIGERANT FLOW DIAGRAM

4-1. Refrigerant Flow Diagram

Indoor unit KHS0951 / KHS1251

Outdoor unit CH0951 / CH1251

Indoor unit

Outdoor unit

 

 

 

 

Accumulator

Compressor

 

 

 

 

 

 

 

Wide tube

 

 

 

Wide tube

service

 

 

 

 

valve

 

 

 

 

 

 

Muffler

4-way

 

 

O.D.

 

valve

 

 

 

 

 

 

3/8" (ø9.52 mm)

 

 

 

 

 

1/2" (ø12.7 mm)

 

 

 

 

 

Heat exchanger

 

tube

 

exchanger

 

 

 

Capillary

 

 

 

 

Narrow

 

 

Heat

 

 

tube

 

 

 

 

 

 

 

 

Narrow tube

service

 

 

 

 

valve

 

Capillary tube

 

 

O.D.

 

Strainer

 

 

 

 

 

 

 

 

1/4" (øø6.35 mm)

 

 

Check

 

 

 

 

 

valve

 

Indoor unit

KHS1852

 

 

 

 

Outdoor unit

CH1852

 

 

 

 

Indoor unit

Outdoor unit

 

 

Accumulator

Compressor

 

 

 

 

Wide tube

 

 

 

Wide tube

service

 

 

 

valve

 

 

 

 

Muffler

 

4-way

 

O.D.

 

valve

 

 

 

 

5/8" (ø15.88 mm)

 

 

 

 

Heatexchanger

Receiver

tube

 

exchanger

 

 

 

 

 

tank

 

 

 

 

 

Capillary

 

 

Narrow

 

 

Heat

 

tube

 

 

 

 

 

 

Narrow tube

service

 

 

 

valve

 

Capillary tube

 

O.D.

Strainer

 

 

 

 

 

 

 

1/4" (øø6.35 mm)

 

 

Check

 

 

 

 

valve

 

 

18

 

 

 

Cooling cycle

Heating cycle

Cooling cycle

Heating cycle

5. PERFORMANCE DATA

5-1. Performance Charts

Indoor Unit

KHS0951

Outdoor Unit

CH0951

Cooling Characteristics

 

115 V

13

Indoor inlet air

D.B. temp. °F (°C)

(A)

12

 

 

 

 

 

 

 

 

 

 

 

 

 

current

11

 

 

 

 

 

 

 

 

 

 

 

 

95 (35.0)

10

 

 

 

 

 

80 (26.7)

Operating

 

 

 

 

 

9

 

 

 

 

 

67 (19.4)

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

6

70

80

90

100

110

120

 

60

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

115 V

150

(10.5)

Indoor inlet air

D.B. temp. °F (°C)

 

 

 

 

140

(9.8)

 

 

 

 

 

 

G)

serveice valve

130

(9.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

psig (kg/cm

120

(8.4)

 

 

 

 

 

 

110

(7.7)

 

 

 

 

 

 

100

 

 

 

 

 

 

 

Low pressure

at wide tube

(7.0)

 

 

 

 

 

 

90

(6.3)

 

 

 

 

 

 

80

(5.6)

 

 

 

 

 

95 (35.0)

 

 

 

 

 

80 (26.7)

 

 

70

(4.9)

 

 

 

 

 

67 (19.4)

 

 

 

 

 

 

 

 

 

 

60

(4.2)

 

 

 

 

 

 

 

 

50

(3.5)

70

80

90

100

110

120

 

 

 

60

 

 

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

Heating Characteristics

 

115 V

13

Indoor inlet air

D.B. temp. °F (°C)

(A)

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current

11

 

 

 

 

 

 

80 (26.7)

 

 

 

 

 

 

 

10

 

 

 

 

 

 

70 (21.1)

Operating

9

 

 

 

 

 

 

59 (15.0)

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

115 V

340

(23.9)

Indoor inlet air

D.B. temp. °F (°C)

 

 

 

 

320 (22.5)

 

 

 

 

 

 

 

G)

serveice valve

300 (21.1)

 

 

 

 

 

 

80 (26.7)

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

70 (21.1)

psig (kg/cm

280 (19.7)

 

 

 

 

 

 

 

 

 

 

 

 

59 (15.0)

 

 

 

 

 

 

 

260 (18.3)

 

 

 

 

 

 

 

240 (16.9)

 

 

 

 

 

 

 

High pressure

at wide tube

 

 

 

 

 

 

 

220 (15.5)

 

 

 

 

 

 

 

200 (14.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180 (12.7)

 

 

 

 

 

 

 

 

 

160 (11.2)

 

 

 

 

 

 

 

 

 

150 (10.5)

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

NOTE

Overload prevention operates to protect the air conditioner when the outdoor ambient temperature reaches an abnormally high level while in heating mode. (Refer to 8-5. Overload prevention)

● ......

Points of Rating condition

 

 

Black dots in above charts indicate the following rating conditions.

Cooling:

Indoor air temperature 80°F D.B. / 67°F W.B.

Heating: Indoor air temperature 70F° D.B.

 

Outdoor air temperature 95°F D.B.

Outdoor air temperature 47°F D.B. / 43°F W.B.

19

Indoor Unit

KHS1251

Outdoor Unit

CH1251

Cooling Characteristics

 

115 V

14

Indoor inlet air

D.B. temp. °F (°C)

(A)

13

 

 

 

 

 

95 (35.0)

 

 

 

 

 

 

 

 

 

 

 

 

80 (26.7)

current

12

 

 

 

 

 

 

 

 

 

 

67 (19.4)

 

 

 

 

 

 

11

 

 

 

 

 

 

Operating

 

 

 

 

 

 

10

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

7

70

80

90

100

110

120

 

60

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

115 V

150

(10.5)

Indoor inlet air

D.B. temp. °F (°C)

 

 

 

 

140

(9.8)

 

 

 

 

 

 

G)

serveice valve

130

(9.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

psig (kg/cm

120

(8.4)

 

 

 

 

 

 

110

(7.7)

 

 

 

 

 

 

100

 

 

 

 

 

 

 

Low pressure

at wide tube

(7.0)

 

 

 

 

 

 

90

(6.3)

 

 

 

 

 

 

80

(5.6)

 

 

 

 

 

95 (35.0)

 

 

70

(4.9)

 

 

 

 

 

80 (26.7)

 

 

 

 

 

 

 

67 (19.4)

 

 

 

 

 

 

 

 

 

 

 

60

(4.2)

 

 

 

 

 

 

 

 

50

(3.5)

70

80

90

100

110

120

 

 

 

60

 

 

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

Heating Characteristics

 

115 V

14

Indoor inlet air

D.B. temp. °F (°C)

(A)

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current

12

 

 

 

 

 

 

80 (26.7)

 

 

 

 

 

 

 

70 (21.1)

11

 

 

 

 

 

 

59 (15.0)

Operating

10

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

115 V

340

(23.9)

Indoor inlet air

 

D.B. temp. °F (°C)

80 (26.7)

 

 

 

 

320 (22.5)

 

 

 

 

 

 

70 (21.1)

 

 

 

 

 

 

 

 

 

G)

serveice valve

300 (21.1)

 

 

 

 

 

 

59 (15.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

psig (kg/cm

280 (19.7)

 

 

 

 

 

 

 

260 (18.3)

 

 

 

 

 

 

 

240 (16.9)

 

 

 

 

 

 

 

High pressure

at wide tube

 

 

 

 

 

 

 

220 (15.5)

 

 

 

 

 

 

 

200 (14.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180 (12.7)

 

 

 

 

 

 

 

 

 

160 (11.2)

 

 

 

 

 

 

 

 

 

150 (10.5)

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

NOTE

Overload prevention operates to protect the air conditioner when the outdoor ambient temperature reaches an abnormally high level while in heating mode. (Refer to 8-5. Overload prevention)

● ......

Points of Rating condition

 

 

Black dots in above charts indicate the following rating conditions.

Cooling:

Indoor air temperature 80°F D.B. / 67°F W.B.

Heating: Indoor air temperature 70F° D.B.

 

Outdoor air temperature 95°F D.B.

Outdoor air temperature 47°F D.B. / 43°F W.B.

20

Indoor Unit

KHS1852

Outdoor Unit

CH1852

Cooling Characteristics

 

230 V

12

Indoor inlet air

D.B. temp. °F (°C)

(A)

11

 

 

 

 

 

 

 

 

 

 

 

 

 

current

10

 

 

 

 

 

95 (35.0)

 

 

 

 

 

 

9

 

 

 

 

 

80 (26.7)

Operating

 

 

 

 

 

 

67 (19.4)

8

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

5

70

80

90

100

110

120

 

60

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

230/208 V

150

(10.5)

Indoor inlet air

D.B. temp. °F (°C)

 

 

 

 

140

(9.8)

 

 

 

 

 

 

G)

serveice valve

130

(9.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

psig (kg/cm

120

(8.4)

 

 

 

 

 

 

110

(7.7)

 

 

 

 

 

 

100

 

 

 

 

 

 

 

Low pressure

at wide tube

(7.0)

 

 

 

 

 

 

90

(6.3)

 

 

 

 

 

95 (35.0)

80

(5.6)

 

 

 

 

 

 

 

 

 

 

 

 

80 (26.7)

 

 

70

(4.9)

 

 

 

 

 

 

 

 

 

 

 

 

67 (19.4)

 

 

 

 

 

 

 

 

 

 

 

60

(4.2)

 

 

 

 

 

 

 

 

50

(3.5)

70

80

90

100

110

120

 

 

 

60

 

 

 

(15.6)(21.1) (26.7) (32.2) (37.8) (43.3) (48.9)

Outdoor inlet air D.B. temp. °F (°C)

Heating Characteristics

 

230 V

12

Indoor inlet air

D.B. temp. °F (°C)

(A)

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current

10

 

 

 

 

 

 

 

9

 

 

 

 

 

 

80 (26.7)

 

 

 

 

 

 

 

Operating

 

 

 

 

 

 

70 (21.1)

 

 

 

 

 

 

 

8

 

 

 

 

 

 

59 (15.0)

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

 

 

230/208 V

 

 

 

 

 

 

 

 

 

Indoor inlet air

 

80 (26.7)

 

 

340 (23.9)

 

 

 

 

 

 

D.B. temp. °F (°C)

 

 

 

 

 

 

 

 

 

 

320 (22.5)

 

 

 

 

 

 

 

G)

serveice valve

300 (21.1)

 

 

 

 

 

 

70 (21.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

psig (kg/cm

280 (19.7)

 

 

 

 

 

 

59 (15.0)

 

 

 

 

 

 

 

260 (18.3)

 

 

 

 

 

 

 

240 (16.9)

 

 

 

 

 

 

 

High pressure

at wide tube

 

 

 

 

 

 

 

220 (15.5)

 

 

 

 

 

 

 

200 (14.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

180 (12.7)

 

 

 

 

 

 

 

 

 

160 (11.2)

 

 

 

 

 

 

 

 

 

150 (10.5)

 

 

 

 

 

 

 

 

 

10

20

30

40

50

60

70

80

 

 

(–12.2)(–6.6) (–1.1)

(4.4)

(10.0) (15.6) (21.1) (26.7)

Outdoor inlet air D.B. temp. °F (°C)

NOTE

Overload prevention operates to protect the air conditioner when the outdoor ambient temperature reaches an abnormally high level while in heating mode. (Refer to 8-5. Overload prevention)

● ......

Points of Rating condition

 

 

Black dots in above charts indicate the following rating conditions.

Cooling:

Indoor air temperature 80°F D.B. / 67°F W.B.

Heating: Indoor air temperature 70F° D.B.

 

Outdoor air temperature 95°F D.B.

Outdoor air temperature 47°F D.B. / 43°F W.B.

21

5-2. Air Throw Distance Chart

(1) Indoor Unit KHS0951

Cooling

 

 

 

 

 

 

 

Room

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

 

 

 

 

 

 

 

Axis air

Vertical

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

Room

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

0

5

10

15

20

25

30

 

 

0

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis air

Vertical

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 45° ,

 

 

 

 

: Axis air velocity 45°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 60° ,

 

 

 

 

: Axis air velocity 60°

 

 

 

 

 

 

 

 

22

(2) Indoor Unit KHS1251

Cooling

Room air temp. : 80°F (26.7°C)

Fan speed

: High

 

 

 

 

 

Horizontal distance (ft.)

 

 

 

 

0

5

10

15

20

25

30

 

 

0

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis air

Vertical

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 0° ,

 

 

 

 

: Axis air velocity 0°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 30°,

 

 

 

 

: Axis air velocity 30°

 

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

Room

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

0

5

10

15

20

25

30

 

 

0

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis air

Vertical

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 45° ,

 

 

 

 

: Axis air velocity 45°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 60° ,

 

 

 

 

: Axis air velocity 60°

 

 

 

 

 

 

 

 

(3) Indoor Unit KH1852

Cooling

Room air temp. : 80°F (26.7°C)

Fan speed

: High

 

 

 

 

 

Horizontal distance (ft.)

 

 

 

 

0

5

10

15

20

25

30

 

 

0

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis air

Vertical

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 0° ,

 

 

 

 

: Axis air velocity 0°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 30°,

 

 

 

 

: Axis air velocity 30°

 

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

Room

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

0

5

10

15

20

25

30

 

 

0

 

 

 

 

 

 

velocity (ft./sec.)

distance (ft.)

5

 

 

 

 

 

 

 

 

 

 

 

 

 

Axis air

Vertical

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 45° ,

 

 

 

 

: Axis air velocity 45°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

: Flap angle 60° ,

 

 

 

 

: Axis air velocity 60°

 

 

 

 

 

 

 

 

5-3. Cooling Capacity

Indoor Unit

KHS0951

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

CH0951

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115V Single phase 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY :

 

9,100 BTU/h

AIR FLOW RATE:

 

270 CFM

 

EVAPORATOR

 

 

 

 

 

 

 

CONDENSER

 

 

 

 

 

 

 

ENT.TEMP.°F (°C)

 

 

 

 

 

 

 

AMBIENT TEMP

°F

 

(°C)

 

 

 

 

WB

DB

 

 

 

 

 

75

85

95

105

 

115

 

 

 

 

 

 

 

 

(23.9)

(29.4)

(35.0)

(40.6)

 

(46.1)

 

 

 

 

TC

 

 

9,220

8,770

8,260

7,690

 

7,050

 

 

 

 

CI

 

 

0.64

0.7

0.76

0.82

 

0.9

 

 

72(22.2)

 

SHC

 

 

6,720

6,490

6,240

5,960

 

5,650

 

59

76(24.4)

 

SHC

 

 

7,580

7,350

7,090

6,820

 

6,510

 

(15.0)

80(26.7)

 

SHC

 

 

8,470

8,240

7,990

7,690

 

7,050

 

 

84(28.9)

 

SHC

 

 

9,220

8,770

8,260

7,690

 

7,050

 

 

88(28.9)

 

SHC

 

 

9,220

8,770

8,260

7,690

 

7,050

 

 

 

 

TC

 

 

9,560

9,140

8,680

8,160

 

7,600

 

 

 

 

CI

 

 

0.65

0.71

0.77

0.84

 

0.92

 

 

72(22.2)

 

SHC

 

 

5,670

5,470

5,260

5,020

 

4,780

 

63

76(24.4)

 

SHC

 

 

6,520

6,330

6,120

5,880

 

5,630

 

(17.2)

80(26.7)

 

SHC

 

 

7,420

7,220

7,010

6,780

 

6,530

 

 

84(28.9)

 

SHC

 

 

8,270

8,080

7,870

7,630

 

7,380

 

 

88(28.9)

 

SHC

 

 

9,130

8,930

8,680

8,160

 

7,600

 

 

 

 

TC

 

 

9,930

9,540

# 9,100

8,620

 

8,090

 

 

 

 

CI

 

 

0.65

0.71

0.78

0.85

 

0.94

 

 

72(22.2)

 

SHC

 

 

4,610

4,450

4,260

4,060

 

3,850

 

67

76(24.4)

 

SHC

 

 

5,470

5,300

5,120

4,920

 

4,700

 

(19.4)

80(26.7)

 

SHC

 

 

6,360

6,200

6,010

5,810

 

5,600

 

 

84(28.9)

 

SHC

 

 

7,220

7,050

6,870

6,670

 

6,450

 

 

88(28.9)

 

SHC

 

 

8,080

7,910

7,720

7,520

 

7,310

 

 

 

 

TC

 

 

10,460

10,090

9,700

9,270

 

8,800

 

 

 

 

CI

 

 

0.66

0.72

0.79

0.87

 

0.96

 

 

72(22.2)

 

SHC

 

 

3,560

3,420

3,270

3,100

 

2,930

 

71

76(24.4)

 

SHC

 

 

4,420

4,270

4,120

3,960

 

3,790

 

(21.7)

80(26.7)

 

SHC

 

 

5,310

5,170

5,020

4,860

 

4,680

 

 

84(28.9)

 

SHC

 

 

6,170

6,030

5,880

5,710

 

5,540

 

 

88(28.9)

 

SHC

 

 

7,030

6,880

6,730

6,570

 

6,390

 

 

 

 

TC

 

 

10,670

10,320

9,960

9,540

 

9,090

 

 

 

 

CI

 

 

0.67

0.73

0.8

0.89

 

0.99

 

75

76(24.4)

 

SHC

 

 

3,280

3,160

3,040

2,890

 

2,740

 

(23.9)

80(26.7)

 

SHC

 

 

4,180

4,060

3,930

3,790

 

3,640

 

 

84(28.9)

 

SHC

 

 

5,030

4,910

4,790

4,640

 

4,490

 

 

88(28.9)

 

SHC

 

 

5,890

5,770

5,640

5,500

 

5,350

 

 

TC :Total Cooling Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

SHC:Sensible

 

Heat Capacity

 

 

 

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CI :Compressor

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating conditions are

:Outdoor Ambient Temp.95°FDB

:Indoor Unit Entering Air Temp.80°FDB/67°FWB

25

Indoor Unit

KHS1251

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

CH1251

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 V Single phase 60 Hz

 

 

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATING CAPACITY :

 

11,700 BTU/h

AIR FLOW RATE:

 

330 CFM

 

EVAPORATOR

 

 

 

 

 

 

 

CONDENSER

 

 

 

 

 

 

 

ENT.TEMP.°F (°C)

 

 

 

 

 

 

 

AMBIENT TEMP

°F

 

(°C)

 

 

 

 

WB

DB

 

 

 

 

 

75

85

95

105

 

115

 

 

 

 

 

 

 

 

(23.9)

(29.4)

(35.0)

(40.6)

 

(46.1)

 

 

 

 

TC

 

 

11,850

11,280

10,620

9,890

 

9,070

 

 

 

 

CI

 

 

0.89

0.98

1.06

1.15

 

1.26

 

 

72(22.2)

 

SHC

 

 

8,440

8,140

7,800

7,430

 

7,030

 

59

76(24.4)

 

SHC

 

 

9,450

9,150

8,810

8,440

 

8,040

 

(15.0)

80(26.7)

 

SHC

 

 

10,500

10,200

9,860

9,490

 

9,070

 

 

84(28.9)

 

SHC

 

 

11,510

11,210

10,620

9,890

 

9,070

 

 

88(28.9)

 

SHC

 

 

11,850

11,280

10,620

9,890

 

9,070

 

 

 

 

TC

 

 

12,300

11,750

11,160

10,490

 

9,770

 

 

 

 

CI

 

 

0.9

0.99

1.08

1.17

 

1.29

 

 

72(22.2)

 

SHC

 

 

7,180

6,920

6,640

6,320

 

6,000

 

63

76(24.4)

 

SHC

 

 

8,190

7,920

7,640

7,330

 

7,000

 

(17.2)

80(26.7)

 

SHC

 

 

9,240

8,980

8,700

8,380

 

8,060

 

 

84(28.9)

 

SHC

 

 

10,250

9,980

9,700

9,390

 

9,060

 

 

88(28.9)

 

SHC

 

 

11,260

10,990

10,710

10,400

 

9,770

 

 

 

 

TC

 

 

12,760

12,260

# 11,700

11,080

 

10,400

 

 

 

 

CI

 

 

0.91

1

1.09

1.19

 

1.32

 

 

72(22.2)

 

SHC

 

 

5,910

5,690

5,450

5,180

 

4,900

 

67

76(24.4)

 

SHC

 

 

6,920

6,700

6,450

6,190

 

5,900

 

(19.4)

80(26.7)

 

SHC

 

 

7,970

7,750

7,500

7,240

 

6,960

 

 

84(28.9)

 

SHC

 

 

8,980

8,760

8,510

8,250

 

7,960

 

 

88(28.9)

 

SHC

 

 

9,980

9,760

9,520

9,250

 

8,970

 

 

 

 

TC

 

 

13,440

12,980

12,470

11,920

 

11,310

 

 

 

 

CI

 

 

0.92

1.01

1.11

1.22

 

1.35

 

 

72(22.2)

 

SHC

 

 

4,660

4,470

4,270

4,050

 

3,820

 

71

76(24.4)

 

SHC

 

 

5,660

5,480

5,280

5,060

 

4,830

 

(21.7)

80(26.7)

 

SHC

 

 

6,720

6,530

6,330

6,110

 

5,880

 

 

84(28.9)

 

SHC

 

 

7,720

7,540

7,330

7,120

 

6,890

 

 

88(28.9)

 

SHC

 

 

8,730

8,540

8,340

8,130

 

7,890

 

 

 

 

TC

 

 

13,710

13,270

12,800

12,260

 

11,690

 

 

 

 

CI

 

 

0.94

1.02

1.12

1.25

 

1.38

 

75

76(24.4)

 

SHC

 

 

4,290

4,130

3,960

3,770

 

3,580

 

(23.9)

80(26.7)

 

SHC

 

 

5,340

5,180

5,020

4,830

 

4,630

 

 

84(28.9)

 

SHC

 

 

6,350

6,190

6,020

5,830

 

5,640

 

 

88(28.9)

 

SHC

 

 

7,360

7,200

7,030

6,840

 

6,640

 

 

TC :Total Cooling Capacity

(BTU/h)

 

 

 

 

 

 

 

 

 

SHC:Sensible

 

Heat Capacity

 

 

 

(BTU/h)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CI :Compressor

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

(kW)

 

 

 

 

 

 

 

 

 

Rating conditions are

:Outdoor Ambient Temp.95°FDB

:Indoor Unit Entering Air Temp.80°FDB/67°FWB

26

Loading...