Sanyo ABC-VW24A User Manual

5 (2)

INSTRUCTION MANUAL MANUEL DE L'UTILISATEUR

AIR PURIFIER

PURIFICATEUR D’AIR

ABC-VW24A

Thank you for purchasing this air purifier. Be sure to read this instruction manual thoroughly to ensure correct use.

Nous vous remercions d’avoir acheté ce

English

purificateur d’air.

Veillez à lire complètement ce mode d’emploi

afin d’utiliser correctement l’appareil.

Français

 

Page

English

E-1

E -14

Français

F-1

F -14

READ AND SAVE THESE INSTRUCTIONS

VEUILLEZ LIRE ET SAUVEGARDER CES INSTRUCTIONS

Precautions

Read the “Precautions” carefully before using this device to ensure proper operation.Follow these precautions to ensure the safe and proper operation of this device and to prevent

injury or damage to you or any others. In addition, the presumed results of mishandling this device are divided into “Warning” and “Caution” to specify the extent of injury or damage that can be expected and degree of urgency. Always ensure that these instructions are followed as they are related to important safety issues.

Thank you for choosing SANYO. Please read all instructions carefully to obtain maximum benefit of your product. Questions? Our toll free number is 1-800-263-2244, 9am - 5pm,

Monday to Friday (Eastern time).

Warning

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not misuse or inadequately utilize the appliance, and should not play with the appliance.

Do not modify this device. Any disassembly or repair should be conducted by qualified technicians.

This may cause a fire, electrical shock, or injury. Consult with the place of purchase regarding any repairs.

Remove the power plug from the wall outlet before cleaning. In addition, do not insert or pull out the power plug with wet hands.

This may cause an electrical shock or injury.

Do not use this device if the cord or power plug is damaged or if the wall outlet is loose.

This may cause an electrical shock, short circuit, or fire.

Do not scratch, damage, modify, forcefully bend, pull, twist, or bundle the power cord. In addition, do not place heavy objects on or clamp the cord.

This will damage the cord and may cause a fire or electrical shock.

Use only the specified voltage as the power source.

This may cause a fire or electrical shock.

This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

Caution

Do not hold the cord when unplugging from the wall outlet. Always hold the end of the power plug when unplugging the cord.

In addition, periodically wipe away any dust on the power plug.

This may cause a fire from an electrical shock or short circuit.

Do not wipe with petrol or paint thinner and do not spray with insecticides.

This may cause the cord to crack, an electrical shock, or fire.

E-1

Caution

Ensure there is adequate ventilation when using this device with combustible appliances.

This may cause carbon monoxide poisoning. ¡This device does not eliminate carbon monoxide.

Ensure that combustible material or cigarette or incense particles still on fire are not drawn into this device.

This may cause a fire.

Do not use in places with oil particles, i.e. from machinery, suspended in the air.

This may cause cracks or the falling of this device may cause injury.

Ensure that the power plug is removed from the wall outlet when this device is not in use for long periods of time. Dispose of the water in the electrolyzed water unit and tank.

This may cause an electrical shock or fire.

Without electricity, the effect of the electrolyzed water is reduced and mold and bacteria may develop.

Do not place fingers or foreign objects in the air intake or vent.

This may cause an electrical shock or malfunctions.

Do not use this device in extremely humid environments, i.e. bathrooms.

This may cause an electrical shock or malfunctions.

¡Store this manual in an accessible location after reading.

English

E-2

Part Names and Functions

Sensor Sensitivity

Adjustment Slide Tab

Odor Sensor

Power Mist Lamp

Turns on when the power mist is operating.

Electrolyzed Water Lamp

Turns on when the electrolyzed water function is operating.

Clean Indicator

Indicates the degree of cleanliness of the room.

Air inlet

Handle

Side Air Outlet

Air Inlet

Release Button

Cover

Tank

Electrolyzed Water Unit

Generates a sterilized and electrolyzed mist.

Fan

Release Button

Filter

Pre-filter

Front Cover

Cover

Sterilized and Electrolyzed

Mist Outlet

Top Air Outlet

Cord

Power Plug

[Rear]

E-3

Operating Unit

Filter Replacement Lamp (Red)

Turns on when the filter needs to be replaced.

Add Water Lamp (Red)

Turns on when the water needs to be replenished.

Turns on when the device needs to be cleaned.

Air Flow Indicator

(Green) Power On/Off Button

Power Mist

Button

Power Mist Lamp (Green)

Turns on when the power mist is operating.

Timer Indicator

Fan Speed Button

(Green)

Off Timer Button

Automatic Operation Lamp (Green)

Electrolyzed Water Lamp (Green)

Turns on when the electrolyzed water function is operating.

Remove the front cover before operating.

Filter Reset Button

Press this button after

Electrolyzed Water Button

 

replacing the filter.

 

Select Brightness Button

<Removing the Front Cover>

 

e

Safety Mechanism

When this unit tips over, the device is automatically stopped.

¡Stand the device correctly and press the Power On/Off button to restart.

¡If water spills from the electrolyzed water unit and tank, ensure that the spill is cleaned and dry completely before operating the unit.

¡The unit cannot be operated while tilted. ¡The memory is cleared.

Confirm the accessories.

Front Cover

Release

Button

q

w

Release Button

q Press the release buttons (both sides) at the bottom of the unit, w pull the front

qcover away from the unit, and e lift.

Date label

Filter

(The filter has been placed within the device during shipping. Remove the plastic protector and replace the filter into the unit. Refer to page E-5)

English

E-4

Sanyo ABC-VW24A User Manual

Preparations Before Use

Installing the Filter

1 Remove the front cover

¡q Press the Release buttons (both sides) at the bottom of the unit, w pull the front cover away from the unit, and e lift.

e

Front Cover

2 Remove the pre-filter (filter).

¡Hold the tabs of the pre-filter and pull to remove.

Filter

Supports

Pre-filter

Press q

Release Button

 

 

 

 

 

 

q Press

 

Tabs

 

 

 

 

w

 

 

 

Remove the pre-filter from the filter

4

Attach the filter to the pre-filter.

3 and remove from the plastic protector.

¡Insert the side printed with the word “FRONT”

¡Widen the frame of the pre-filter and remove

 

into the side of the net.

the filter.

 

 

 

 

 

Plastic Protector

FRONT

 

 

Net

 

Filter

 

Pre-filter

Pre-filter

Filter

 

5

Attach the pre-filter.

6

Attach the front cover.

¡Ensure that the tabs of the pre-filter are to the

¡q Place the tabs (3) at the top of the front cover

 

front. q Insert the filter under the filter supports

 

into the attachment slots.

 

at the top and then w push the filter in at the

 

¡w Press the bottom until the cover clicks.

 

bottom.

 

 

 

Filter

 

Attachment

 

 

Slots

 

Supports

 

 

 

 

 

q

 

Tabs

 

Tabs

 

 

 

 

 

 

 

Front

 

 

 

Cover

 

Tabs

 

 

 

w

 

 

Note:

¡Always be sure to install the pre-filter, filter and front cover before operating the unit. ¡If the plastic protector is not removed from the filter, the device will not clean the air.

In addition, this may cause a malfunction.

¡Write the date of the filter installation on the date label as a guide for the filter replacement and

attach the label to the unit.

E-5

Warning

Do not place flammable material in the tank. This may cause a fire.

Replenishing the Water

1

Lift the tab on the cover and remove.

2

Remove the tank.

 

 

¡Lift the tank straight up.

Tank

Cover

Tab

Note:

¡Water attached to the cap may drip when removing the tank. Use a towel to ensure that the floor does not get wet.

Loosen the cap to the tank and fill

4

Tighten the cap of the tank.

3 the tank with tap water.

¡Confirm that the cap is on securely.

¡Fill the tank with tap water without overfilling.

As a guide, a full tank of water will last for a

 

maximum of about 2 to 3 weeks of operation.

 

(For automatic operation) The length of time

 

before the tank needs to be refilled will vary

Cap

depending on the usage conditions.

 

Cap

 

Note: Tank

English

¡Wash the cap well as mold may form on the tank cap.

5

Replace the tank.

Tank

6

Replace the cover.

 

¡Line up the tank.

¡Press the cover into

Cover

 

 

place matching the

 

 

 

 

 

configuration.

Water

Use water specified in the attached (Notes).

This may hinder proper operation.

Note:

 

¡Only use tap water below 86°F.

 

¡Mold and bacteria may develop if unspecified water is used and may hinder proper operation.

 

¡Dispose the water in the electrolyzed water unit and tank after removing the power plug. Without

 

electricity, the effect of the electrolyzed water is reduced and mold and bacteria may develop.

 

¡Dispose of the water in the tank if the water has a chance of freezing. If the water freezes, it

 

may cause the device to malfunction.

 

¡If the temperature of the water is low (10°C or below), the sterile electrolytic mist may not be

 

emitted.

 

¡When filling the tank with water, let the water run freely for about 3 to 5 seconds before filling

 

the tank, otherwise the quality of the water remaining in the faucet will deteriorate.

E-6

 

Unit Installation

Adjusting the Sensitivity of the Odor Sensor

1 q Press the Release buttons (both sides) at the bottom of the unit, w pull the front cover away from the unit, and

e lift.

e

Front Cover

Release Button

Release Button q

w q

2 Adjust the sensor sensitivity adjustment slide tab.

¡The tab is set to the middle when shipping. Set the tab to this location during normal operation.

¡To operate when even slightly dirty set to “High”

¡To operate infrequently set to “Low”

Sensor Sensitivity

Adjustment Slide Tab

Unit Installation

1 Place the unit on a stable and horizontal surface and in a location where the air circulates well around the room.

¡This unit operates more effectively when the unit is set in the middle of a wall facing the center of the room.

Caution

¡Unplug the unit when moving or not using for extended periods and dispose of the water in the electrolyzed water unit and tank (water may spill or mold and bacteria may develop).

¡Do not tilt the unit when in use. The electrolyzed water unit may cease to operate properly or water may spill.

Note:

¡Do not set in a location where the air inlet or outlet may be covered.

¡Ensure that AV equipment, i.e. TV and radios, is located at least 6.5ft away (noise may interfere with the equipment).

Ventilate the room to clean the air before plugging the cord into the wall outlet.

2 ¡When the power plug is inserted into the wall outlet and the unit starts operating, the sensor will detect the cleanliness of the air and use this as a reference for making settings. The automatic operation lamp (green) will flash for a short while (about 3 minutes) while this is being done. If the air quality is detected as being clean, the settings will be updated automatically to reflect this.

E-7

Method of Use

The device can be operated according to preference. Normally, it is recommended that automatic operation is selected to operate automatically in response to the cleanliness of the air. When the automatic operation, adjust the sensitivity of the odor sensor (refer to page E-7).

1 Press the power on/off button.

¡Press the power on/off button to operate in [AUTO/Electrolyzed Water “On”] mode after plugging in the power plug.

¡The electrolyzed water and clean lamps turn on.

(The electrolyzed water lamp turns on while operating the electrolyzed water function).

2 Press the fan speed button and operate according to preference.

¡The operating mode switches with each press of the button and the mode is indicated by the corresponding lamp.

AUTO LOW MED HIGH

Manual Operation

Press

Press

Press

When cleaning the air and removing odors in the room automatically

Automatic Operation

¡Press the fan speed button and operate in “AUTO”. ¡Operates automatically when the odor sensor detect dirt or

odor in the air of the room.

¡A sterile, electrolyzed mist is produced (the electrolyzed water function generates a sterile, electrolyzed mist). Press the electrolyzed water button to turn off the electrolyzed water.

¡The electrolyzed water function cannot be operated independently.

*Even when the air of the room is clean, the electrolyzed water function operates silently for about 5 minutes, once every hour, to agitate the water.

English

Operation of the Odor Sensor

The odor sensor operate automatically when set to automatic operation mode.

¡The odor sensor responds to cigarette smoke, insecticides, cosmetics, alcohol, gases generated by burning appliances, and sudden changes of temperature and humidity.

Color of Clean Indicator and Operating Status (Air flow indicator lamp does not turn on)

 

Cleanliness

Clean

 

Very Dirty

Color of Clean Indicator

Green

Yellow

Red

Operating

Fan

Stop

Low

Medium

Status

Sterile, Electrolytic Mist

Stop

Low

Low or Strong

The generated volume of sterile, electrolytic mist is intermittent with Low (small) and Strong (large).

Note:

¡Toxic substances (carbon monoxide, etc.) from cigarettes cannot be eliminated.

¡Odor components (odors from building material, pets, etc.) that are continuously generated cannot be entirely eliminated.

E-8

Method of Use

Continuous Mode

Operate in “HIGH” when vacuuming

Operate in “LOW” when sleeping

Manual Operation Manual Operation

Press

¡Press the fan speed button to choose “LOW”, “MED”, or “HIGH” mode.

¡The volume of sterile, electrolytic mist generated during High is strong (large). The volume is low (small) for all other modes. The mist is generated intermittently.

¡Press the electrolyzed water button to turn the electrolyzed water function “On” or “Off”.

To generate a lot of sterile, electrolytic mist and quickly clean the air in the room

Odors

Mold

Bacteria

Pollen

Dust Mite

Droppings

Power Mist Mode

Press

¡Press the power mist button to operate in power mist mode.

¡High (5 min) → Medium (25 min)

(The air flow indicator does not turn on.)

¡A sterile, electrolytic mist is intermittently generated for 30 minutes.

¡Once the power mist cycle is complete, the device switches to automatic mode.

¡Press the fan speed button to cancel and to switch to a different operating mode.

*When the mode is switched to power mist while the timer is operating, the configured timer cancels.

Stopping the operation at a specified time

OFF!

Timer Operation

Press

¡Press the off timer button and set to a preferred time. Each time the button is pressed, the indicator lamp sets to the timer according to the lamp.

Continuous 1 Hour 2 Hours 8 Hours Operation

(The lamp does not turn on.)

¡The indicators change according to the amount of time that has passed and the lights indicate the amount of time remaining.

¡Once the pre-determined amount of time passes, the device automatically turns off.

* The power mist mode cannot be set with a timer.

E-9

Loading...