Owner’s Manual
ARP-9409, ARP-9411
ARP-9409 / ARP-9411
portable air conditioner ACONDICIONADOR DE AIRE PORTÁTIL CONDITIONNEUR D' AIRE PORTABLE
Página en Español |
17 |
Page en Français |
33 |
Read and retain these instructions for future reference.
For any Customer Support needs, please choose the Support tab on www.royalsovereign.com
Royal Sovereign International, Inc
portable air conditioner
ARP-9409, ARP-9411
INTRODUCTION
Thank you for choosing Royal Sovereign to provide you and your family with all of the “Home Comfort” requirements for your home, apartment, or office. This Portable Air Conditioner can be set-up in just minutes and can be easily moved from room to room. It is a multi-functional room air comfort system that offers you Air Conditioning, Dehumidification and Air Circulation modes. This manual will provide you with valuable information necessary for the proper care and maintenance for your new appliance. Please take a few moments and read the instructions thoroughly. If properly maintained, your appliance will give you many years of troublefree operation.
CONTENTS
Page Precautions for use∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 4 Identification of parts∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 5 Installation instructions∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 6~7 Operation∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 8~11 Maintenance∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 12 Troubleshooting∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 13 Specifications∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14 Warranty∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15 Contact information∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 16
Página en Español∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 17
Precautions for use
Electrical Specifications and Power Cord
Check to ensure that the electrical service being used is adequate for the model you’ve chosen. The electrical rating of your new air conditioner is defined on the serial plate of the unit. Please refer to the rating when checking electrical requirements to ensure they meet the electrical codes of your location.
•Install the air conditioner according to the installation instructions supplied.
•Do not modify any part of this product.
•Do not insert any objects into the product or block the airflow in any way.
•Ensure that the power supply you use has an appropriate voltage rating.
•Only use a properly installed 3 pin, grounded AC socket that is rated 115V, 60Hz, 15 amps or more.
•If the electrical outlet you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, you should have a qualified electrician install the proper outlet.
•This unit uses a plug with a built-in fuse. Conduct a Power Plug Check (see page 9) before use to confirm normal operation.
•Do not use this unit with any extension cords or adapter plugs.
•If the cord or plug is damaged in any way, please call the Royal Sovereign Service Department ( see page 16.)
•Do not plug this cord into a loose electrical outlet.
•Turn the unit off and unplug, when cleaning the air conditioner, removing the filter or when the air conditioner will not be used for an extended time period.
General Use
•Do not block air outlets or intake with obstacles.
•Do not insert any objects into the air conditioner.
•Do not splash or pour water on the housing or control panel.
•Do not place heavy items or sit on unit.
•Make sure the drainage plug is installed on bottom of machine.
•Drain the unit when moving the air conditioner or when storing the unit.
4
ARP-9409 / 9411
Identification of parts
1.Control panel
2.Air outlet
3.Remote control
4.Handle
5.Exhaust hose
6.Air intake
7.Exhaust outlet
8. Filter
9. Drain port
10. Power cord
11. Power cord hooks
12. Secondary drain port
13. Caster wheel
5
Installation
Unpack your New Portable Air Conditioner and let the machine stand upright for 2 hours before starting.
Unpack all parts listed below. If any parts are missing do not return this product to the place of purchase.
Please visit our website www.royalsovereign.com and click on the “Support” tab .
Accessories Include
1.Exhaust hose
2.Hose connector
3.Hose adapter
4.Remote control
5.Water tray
6.Drainage hose
7.Window slider
Part 1: Exhaust hose, connector and adapter
1.Extend one end of the exhaust hose.
2.Take the hose connector and twist it counterclockwise onto one end of the exhaust hose.
3.Extend the opposite end of the exhaust hose.
4.Take the hose adapter and twist it counterclockwise onto the unused end of the exhaust hose.
Fig 1.
6
ARP-9409 / 9411
Part 2: Attaching exhaust hose
1.Hold the exhaust hose parallel to the floor with the hose connector positioned up and down
2.Line up the hose connector above the tabs on the exhaust outlet. Slide connector down into the tabs locking the connector in place.
Fig 2.
Part 3: Installing window slider kit
1.Open the window and place the window slider on the inside edge of the window.
2.Adjust the window slider to the width of the window.
3.Insert a screw into the top of the window slider to secure it at the correct length.
4.Take window slider out and attach to exhaust hose by snapping the hose adapter into the hole on the window slider. Make sure that the tabs on the window slider are facing outside.
5.Extend exhaust hose to desired length.
6.Place window slider and hose into the edge of the window.
7.Close window to secure slider.
Fig 3. |
Fig 4. |
|
7
Operation
Before Use
•Check to make sure rubber drain plugs are securely plugged into the drain ports on the back of the unit to prevent water leaks
•Check to make sure that air conditioner has been properly vented out the window ( See Installation pg 7.)
•Check to make sure air conditioner is on a flat surface
•Conduct a Power Plug Check:
1.Press the RESET button on the power cord.
2.Plug cord into an electrical outlet.
3.Press the TEST button on the power cord. The RESET button should pop up.
4.Press the RESET button for use.
5.Do not use the air conditioner if the test fails. The green light on the power cord will turn on if the plug is working properly.
Note: If you turn the air conditioner off and immediately restart it, allow 3 minutes for the compressor to restart cooling. In the event of a power failure, wait 3 minutes before restarting unit.
Control Panel |
|
|
Buttons |
|
|
Power button |
Timer button |
|
Sleep mode button |
Fan speed button |
|
Mode button |
Temperature / Timer up button |
F |
Temperature / Timer down button |
C |
|
H |
||
Indicator Lights |
|
|
Low fan speed |
High fan speed |
|
Automatic mode |
Cool mode |
|
Dehumidify mode |
Fan only mode |
|
8
ARP-9409 / 9411
Control Panel Operation
Automatic, Cool, Dehumidify, Fan Only Mode Operation
1.Turn the unit on
Press the Power button to turn the unit on. The red light next to the power button and the Mode, Fan speed, and temperature indicators will light up.
2.Select operating mode
Press the button to select desired operating mode:
3.Adjust temperature
The temperature can be set within a range of 59°F to 87°F by 1 °F intervals.
Press |
, |
to increase or decrease the temperature. The LED display will flash the desired temperature for 5 seconds then display the current room temperature. |
4. Adjust fan speed |
||
Press the |
|
button to select desired fan speed. |
5.Power down
Press the power button again to turn the unit off.
Mode Descriptions |
|
Automatic mode |
|
When is selected the unit will automatically select the operation mode with |
or . |
When room temperature is greater than 75 °F the unit will automatically select |
mode. |
When room temperature is less than 75 °F the unit will automatically select |
mode. |
9
Cool mode
Whenmode is chosen the air conditioner will run when the room temperature is higher than the set temperature.
When the room temperature is lower than the set temperature only the fan will run.
Dehumidify mode
When in mode then fan will run at low speed and cannot be adjusted.
Temperature cannot be adjusted during dehumidify mode.
The compressor will stop running after 8 minutes and will turn back on after 6 minutes and will continue to cycle on and off.
Fan mode
When is selected the unit will only run the fan at low or high speed.
Temperature cannot be adjusted during fan mode.
Timer Operation
The timer can be used to turn the unit off after a set amount of time, or to turn the unit on after a set amount of time.
To use the timer to turn the unit on: While air conditioner is off press the button. The light next to the timer button will blink and 0 will show on the LED display. Press the ,buttons to adjust the time up to 24 hours. You can also pre-select Mode and Fan speed while timer light is blinking. The light next to the timer will stay lit up to show that
timer is set. The unit will turn on after the set time has passed. |
|
To use the timer to turn the unit off: Press the button. The light next to the timer button will blink and 0 will show on the LED display. Press the |
, buttons to adjust |
the time up to 24 hours. The unit will shut down after the set time has passed. |
|
Sleep Mode Operation
Sleep mode can only be operated when the unit is in Cool mode. When in Sleep mode the set temperature will 1 °F after one hour and 2 °F after two hours. After six hours have passed the unit will stop running.
To use sleep mode: Make sure the unit is in Cool mode. Press the button. The light next to the sleep button will turn on.
Note: The unit has a memory function, when the unit is turned off and back on the previous setting should remain intact. This function does not work when unit is left in Automatic mode.
10