Appendix A

Specifications

A

This appendix lists the following specifications for the L25 and L100 libraries:

Physical

Performance

Reliability

Environmental

Tape drive

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

105

Appendix A Specifications

Physical Specifications

Physical Specifications

Table 6 Unit

Dimensions/Weight

Table 7 Capacities

 

L25

L100

 

 

 

Width

19 in. (482 mm)

19 in. (482 mm)

 

 

 

Depth

28.6 in. (726 mm)

28.6 in. (726 mm)

 

 

 

Height

6.9 in. (176 mm)

23.4 in. (595 mm)

 

 

 

Weight

69 lbs. (31kg) with 2 drives,

207 lbs. (94 kg) with 5

 

2 magazines, and 0

drives, 8 magazines, and 0

 

cartridges installed

cartridges installed

 

 

214 lbs. (97 kg) with 6

 

 

drives, 7 magazines, and 0

 

 

cartridges installed

 

 

 

 

L25

 

L100

 

 

 

 

Number of Tape

Up to 2

 

Up to 6

Drives

 

 

 

 

 

 

 

Type of Tape Drives

DLT 8000, SDLT, or LTO

 

 

 

 

Number of Tape

Up to 20 DLT or

 

Up to 80 DLT or

Cartridges

SDLT tape cartridges

 

SDLT tape cartridges

 

(excluding the fixed

 

(excluding the fixed

 

slot)

 

slots)

 

Up to 24 LTO

 

Up to 96 LTO tape

 

cartridges (excluding

 

cartridges (excluding

 

the fixed slot)

 

the fixed slots)

 

 

 

 

106 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

 

 

 

Appendix A Specifications

 

 

Performance Specifications

 

 

 

 

 

L25

 

L100

 

 

 

 

Type of Tape

For use with:

 

 

Cartridges

• DLT 8000 drives: DLTtape III or DLTtape IV

 

• SDLT drives: DLTtape IV* or Super

 

DLTtape 1

 

 

 

• LTO drives: LTO Ultrium cartridges

 

 

 

 

Number of

Up to 2

 

Up to 8

Magazines

 

 

 

 

 

 

Magazine Capacity

Each magazine holds up to 10 DLT or SDLT

 

tape cartridges or up to 12 LTO tape cartridges

 

 

 

 

Manual Access

Yes

 

Yes

Facility

 

 

 

 

 

 

 

Cleaning Cartridge/

1

 

4

Extra Data Slots

 

 

 

 

 

 

 

Robot Mounted Bar

Yes

 

Yes

Code Reader

 

 

 

 

 

 

 

StackLink

Yes

 

Yes

Scalability

 

 

 

 

 

 

 

* SDLT read only

 

 

 

Performance Specifications

Table 8 Performance

 

 

L25

L100

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

Average Swap Time

Less than 10 seconds

Less than 11 seconds

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

107

Appendix A Specifications

Reliability Specifications

Table 9 Library

Performance

 

 

 

 

Maximum

 

 

 

 

 

Data

Data

 

 

 

 

 

Capacity

Capacity

Maximum

 

 

 

 

(Excluding

(Including

Data

 

 

 

 

Fixed Slots)

Fixed Slots)

Throughput

Host Interfaces

 

 

 

 

 

 

 

 

 

DLT 8000

1.6 TB*

1.68 TB*

86.4 GB/hr*

HVD SCSI-2Fast/Wide

L25

 

 

 

 

 

 

 

SDLT

4.4 TB*

4.62 TB*

158.4 GB/hr*

HVD, Ultra 2 SCSI

 

 

 

 

 

 

 

 

 

LTO

4.8 TB*

5 TB*

216 GB/hr*

HVD, Ultra 2 SCSI

 

 

 

 

 

 

 

 

 

DLT 8000

6.4 TB*

6.72 TB*

59.2 GB/hr*

HVD SCSI-2Fast/Wide

L100

 

 

 

 

 

 

 

SDLT

17.6 TB*

18.48 TB*

475.2 GB/hr*

HVD, Ultra 2 SCSI

 

 

 

 

 

 

 

 

 

 

 

LTO

19.2 TB*

20 TB*

648 GB/hr*

HVD, Ultra 2 SCSI

 

 

 

 

 

 

 

 

* Assuming 2:1 compression ratios

 

 

Reliability Specifications

Table 10 Reliability

 

MSBF

Swap cycles 1,000,000 swaps

Specifications

 

 

 

 

 

 

 

 

 

 

MTTR

Less than 20 minutes

 

 

 

 

108 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix A Specifications

Tape Drive Specifications

Tape Drive Specifications

Table 11 Tape Drive

 

 

 

Native Mode

 

With 2:1 Compression

Specifications

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

Number

Transfer Rate

Capacity

Transfer Rate

Capacity

 

 

 

 

 

 

 

 

 

DLT 8000*

360 MB/min.

40 GB

720 MB/min.

80 GB

 

 

SDLT

660 MB/min.

110 GB

1320 MB/min.

220 GB

 

 

LTO

 

900 MB/min.

100 GB

1800 MB/min.

200 GB

 

 

 

 

 

 

 

*

Average file access time (from BOT) = 60 seconds

 

 

 

Average file access time (from BOT) = 70 seconds

 

Environmental Specifications

Table 12

Power

 

 

 

 

L25

 

L100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

Voltage

88-264VAC,47-63Hz

 

 

 

Input

 

 

 

 

 

 

 

 

Tolerances

 

Power

110W (average)

 

300W (average) (6

 

 

 

 

 

 

 

 

drives fitted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 13

Climate

 

 

 

Temperature

Temperature

 

 

 

 

 

 

 

 

 

 

(Operating)

(Non-Operating)

 

 

 

 

 

 

 

 

 

 

Temperature

 

+50°F to 104°F

-22°Fto +122°F

 

 

 

 

 

(+10°C to +40°C)

(-30°Cto +50°F)

 

 

 

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

109

Appendix A Specifications

Environmental Specifications

Table 14 Compliance

and Certification

 

Temperature

Temperature

 

(Operating)

(Non-Operating)

 

 

 

 

Humidity

20% to 80%

5% to 90%

 

non-condensing

non-condensing

 

 

 

 

Altitude

-1,000to +10,000 feet

-1,000to +36,000 feet

 

(-300to +3,000 meters)

(-300to +11,000 meters)

 

 

 

 

 

 

 

Safety

 

CSA C22.2 950, UL 1950, EN 60950

 

 

 

EMC/RFI

 

FCC CFR 47-15J(level A), EN55022 (CISPR 22)

 

 

level B, EN55024 (CISPR 24), VCCI

 

 

Agency Markings

CE, VCCI, UL, FCC, CSA

 

 

 

 

110 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B

Fault Symptom Code

(FSC) Dictionary

B

Table 15 lists the fault symptom codes (FSCs) for the L25 and L100 libraries.

Table 15

Fault

 

 

 

 

Symptom Codes

 

 

 

 

 

 

 

 

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

0001

FSC_DIVIDE_BY_ZERO

A divide by zero

Microcode

100%

 

 

 

exception has occurred

 

 

 

 

 

 

 

0002

FSC_BUS_PARITY_

A parity error has been

N/A

100%

 

ERROR

detected on the

 

 

 

 

 

address/data bus

 

 

 

 

 

 

 

0003

FSC_NO_MEMORY

Out of memory

Microcode

100%

 

 

 

 

 

0004

FSC_FLSBUF_CALLED

_flsbuf was called

Microcode

100%

 

 

 

 

 

0005

FSC_GETBUF_CALLED

_getbuf was called

Microcode

100%

 

 

 

 

 

0006

FSC_STACK_ERROR

Stack was exhausted

Microcode

100%

 

 

 

 

 

0007

FSC_FLOAT_TRAP

Floating point trap

Microcode

100%

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

111

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

0008

FSC_BAD_FREE

Free() called on bad

Microcode

100%

 

 

memory block

 

 

 

 

 

 

 

0009

FSC_BAD_REALLOC

Realloc() called on bad

Microcode

100%

 

 

memory block

 

 

 

 

 

 

 

000A

FSC_HAND_CV

Hand CV check found

Microcode

100%

 

 

hand disconnected

 

 

 

 

 

 

 

000B

FSC_SERVO_CV

Servo CV check found

Microcode

100%

 

 

servo board

 

 

 

 

disconnected

 

 

 

 

 

 

 

000C

FSC_X_AXIS_CV

X axis CV check found

Microcode

100%

 

 

X axis disconnected

 

 

 

 

 

 

 

000D

FSC_Y_AXIS_CV

Y axis CV check found

Microcode

100%

 

 

Y axis disconnected

 

 

 

 

 

 

 

000E

FSC_Z_AXIS_CV

Z axis CV check found

Microcode

100%

 

 

Z axis disconnected

 

 

 

 

 

 

 

000F

FSC_FP_CV

FP CV check found

Microcode

100%

 

 

front panel

 

 

 

 

disconnected

 

 

 

 

 

 

 

0010

FSC_BAD_FREE_

Free() found corrupted

Microcode

100%

 

TRAILER

memory block trailer

 

 

 

 

 

 

 

0011

FSC_BAD_REALLOC_

Realloc() found

Microcode

100%

 

TRAILER

corrupted memory

 

 

 

 

block trailer

 

 

 

 

 

 

 

0012

FSC_NVR_OVERFLOW

NVR capacity

Microcode

100%

 

 

exceeded

 

 

 

 

 

 

 

0013

FSC_BAD_MALLOC_

Heap consistency

Microcode

100%

 

BLOCK_HDR

check found

 

 

 

 

corruption

 

 

 

 

 

 

 

112 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

0014

FSC_BAD_MALLOC_

Heap consistency

Microcode

100%

 

BLOCK_TRAILER

check found

 

 

 

 

corruption

 

 

 

 

 

 

 

0015

FSC_WATCHDOG_

An unexpected non-

Microcode

100%

 

ERROR

maskable interrupt has

 

 

 

 

occurred

 

 

 

 

 

 

 

0016

FSC_MALLOC_

Size passed to malloc

Microcode

100%

 

REQUEST_TOO_BIG

too large

 

 

 

 

 

 

 

0017

FSC_CALLOC_

Size passed to calloc

Microcode

100%

 

REQUEST_TOO_BIG

too large

 

 

 

 

 

 

 

0018

FSC_REALLOC_

Size passed to realloc

Microcode

100%

 

REQUEST_TOO_BIG

too large

 

 

 

 

 

 

 

0019

FSC_EXCEPTION_3

Breakpoint instruction

Microcode

100%

 

 

executed

 

 

 

 

 

 

 

001A

FSC_EXCEPTION_1

Debug exception

Microcode

100%

 

 

occurred

 

 

 

 

 

 

 

001B

FSC_NULL_POINTER_

Code attempted to

Microcode

100%

 

WRITE

write to address 0

 

 

 

 

 

 

 

001C

FSC_EXECUTE_AT_0

Code attempted to

Microcode

100%

 

 

execute at address 0

 

 

 

 

 

 

 

001D

FSC_NULL_POINTER_

Code attempted to

Microcode

100%

 

WRITE_NEAR

write to address 0

 

 

 

 

 

 

 

001E

FSC_EXECUTE_AT_0_

Code attempted to

Microcode

100%

 

NEAR

execute at address 0

 

 

 

 

 

 

 

001F

FSC_UNSUPPORTED_

Old system boards are

Microcode

100%

 

SYSTEM_BOARD

no longer supported

 

 

 

 

 

 

 

0020

FSC_NO_OSTIMER_

OS timer interrupt

Microcode

100%

 

INTERRUPT

should have occurred,

 

 

 

 

but hasn't

 

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

113

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

1000

FSC_FPGA_INIT_

FPGA INIT pin was

System

100%

 

STUCK_HI

detected as being high

 

 

 

 

when it should have

 

 

 

 

been low

 

 

 

 

 

 

 

1001

FSC_FPGA_INIT_NOT_

FPGA INIT pin was

System

100%

 

HI

detected as being low

 

 

 

 

when it should have

 

 

 

 

been high

 

 

 

 

 

 

 

1002

FSC_FPGA_DONE_

FPGA DONE pin was

System

100%

 

STUCK_HI

detected as being high

 

 

 

 

when it should have

 

 

 

 

been low

 

 

 

 

 

 

 

1003

FSC_FPGA_DONE_NOT_

FPGA DONE pin was

System

100%

 

HI

detected as being low

 

 

 

 

when it should have

 

 

 

 

been high

 

 

 

 

 

 

 

2000

FSC_DLT_INIT_FAILED

DLT initialization

Microcode

100%

 

 

failed

 

 

 

 

 

 

 

2001

FSC_DRIVE_TIMEOUT_1

Drive time out waiting

Drive

100%

 

 

for status (drive 1)

 

 

 

 

 

 

 

2002

FSC_DRIVE_TIMEOUT_2

Drive time out waiting

Drive

100%

 

 

for status (drive 2)

 

 

 

 

 

 

 

2003

FSC_DRIVE_TIMEOUT_3

Drive time out waiting

Drive

100%

 

 

for status (drive 3)

 

 

 

 

 

 

 

2004

FSC_DRIVE_TIMEOUT_4

Drive time out waiting

Drive

100%

 

 

for status (drive 4)

 

 

 

 

 

 

 

2005

FSC_DRIVE_TIMEOUT_5

Drive time out waiting

Drive

100%

 

 

for status (drive 5)

 

 

 

 

 

 

 

2006

FSC_DRIVE_TIMEOUT_6

Drive time out waiting

Drive

100%

 

 

for status (drive 6)

 

 

 

 

 

 

 

114 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2007

FSC_DRIVE_TIMEOUT_7

Drive time out waiting

Drive

100%

 

 

for status (drive 7)

 

 

 

 

 

 

 

2008

FSC_DRIVE_TIMEOUT_8

Drive time out waiting

Drive

100%

 

 

for status (drive 8)

 

 

 

 

 

 

 

2009

FSC_DRIVE_OLD_

Requires newer

System

100%

 

SYSTEM_BOARD

version of system

 

 

 

 

board

 

 

 

 

 

 

 

200A

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_1

present (drive 1)

 

 

 

 

 

 

 

200B

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_2

present (drive 2)

 

 

 

 

 

 

 

200C

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_3

present (drive 3)

 

 

 

 

 

 

 

200D

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_4

present (drive 4)

 

 

 

 

 

 

 

200E

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_5

present (drive 5)

 

 

 

 

 

 

 

200F

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_6

present (drive 6)

 

 

 

 

 

 

 

2010

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_7

present (drive 7)

 

 

 

 

 

 

 

2011

FSC_DRIVE_NOT_

Drive caddy not

Drive

100%

 

PRESENT_8

present (drive 8)

 

 

 

 

 

 

 

2012

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_1

from drive 1

 

 

 

 

 

 

 

2013

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_2

from drive 2

 

 

 

 

 

 

 

2014

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_3

from drive 3

 

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

115

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2015

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_4

from drive 4

 

 

 

 

 

 

 

2016

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_5

from drive 5

 

 

 

 

 

 

 

2017

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_6

from drive 6

 

 

 

 

 

 

 

2018

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_7

from drive 7

 

 

 

 

 

 

 

2019

FSC_INVALID_STUFF_

Invalid byte received

Drive

100%

 

BYTE_8

from drive 8

 

 

 

 

 

 

 

201A

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

1

from drive 1

 

 

 

 

 

 

 

201B

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

2

from drive 2

 

 

 

 

 

 

 

201C

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

3

from drive 3

 

 

 

 

 

 

 

201D

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

4

from drive 4

 

 

 

 

 

 

 

201E

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

5

from drive 5

 

 

 

 

 

 

 

201F

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

6

from drive 6

 

 

 

 

 

 

 

2020

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

7

from drive 7

 

 

 

 

 

 

 

2021

FSC_INVALID_PACKET_

Invalid packet received

Drive

100%

 

8

from drive 8

 

 

 

 

 

 

 

2022

FSC_NOT_

The requested function

Drive

100%

 

IMPLEMENTED

is not implemented in

 

 

 

 

the drive type

 

 

 

 

 

 

 

116 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2023

FSC_DRIVE_NO_

Couldn't get

Microcode

100%

 

RESOURCE

semaphore from OS

 

 

 

 

 

 

 

2024

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_1

received from drive 1

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2025

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_2

received from drive 2

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2026

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_3

received from drive 3

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2027

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_4

received from drive 4

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2028

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_5

received from drive 5

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2029

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_6

received from drive 6

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

202A

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_7

received from drive 7

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

117

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

202B

FSC_COMMAND_

Response packet

Drive

100%

 

FAILED_8

received from drive 8

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

202C

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_1

received from drive 1

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

202D

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_2

received from drive 2

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

202E

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_3

received from drive 3

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

202F

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_4

received from drive 4

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2030

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_5

received from drive 5

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2031

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_6

received from drive 6

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2032

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_7

received from drive 7

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

118 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2033

FSC_SEAGATE_SCSI_

Response packet

Drive

100%

 

CMD_ERROR_8

received from drive 8

 

 

 

 

indicates command

 

 

 

 

failed

 

 

 

 

 

 

 

2034

FSC_HP_BUSY_1

Response packet

Drive

100%

 

 

received from drive 1

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2035

FSC_HP_BUSY_2

Response packet

Drive

100%

 

 

received from drive 2

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2036

FSC_HP_BUSY_3

Response packet

Drive

100%

 

 

received from drive 3

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2037

FSC_HP_BUSY_4

Response packet

Drive

100%

 

 

received from drive 4

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2038

FSC_HP_BUSY_5

Response packet

Drive

100%

 

 

received from drive 5

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2039

FSC_HP_BUSY_6

Response packet

Drive

100%

 

 

received from drive 6

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

203A

FSC_HP_BUSY_7

Response packet

Drive

100%

 

 

received from drive 7

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

203B

FSC_HP_BUSY_8

Response packet

Drive

100%

 

 

received from drive 8

 

 

 

 

indicates drive busy

 

 

 

 

 

 

 

2100

FSC_I2C_FAILED_INIT

I2C interface failed to

Microcode

100%

 

 

initialize

 

 

 

 

 

 

 

2101

FSC_I2C_TIMEOUT_

Timed out waiting for

I2C

100%

 

BUS_BUSY

I2C bus to go not busy

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

119

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2102

FSC_I2C_NO_

No acknowledge

I2C

100%

 

ACKNOWLEDGEMENT

received from slave

 

 

 

 

 

 

 

2103

FSC_I2C_UNABLE_TO_

Exceeded retry limit

I2C

100%

 

SEND_MESSAGE

while trying to send

 

 

 

 

message

 

 

 

 

 

 

 

2104

FSC_I2C_NO_

Expected response

I2C

100%

 

RESPONSE_FROM_

from hardware was not

 

 

 

HARDWARE

received

 

 

 

 

 

 

 

2105

FSC_I2C_UNKNOWN_

Message received from

I2C

100%

 

MESSAGE_

I2C bus but destination

 

 

 

DESTINATION

is unknown

 

 

 

 

 

 

 

2106

FSC_I2C_MESSAGE_

Message to send over

I2C

100%

 

TOO_BIG

I2C bus is too big (see

 

 

 

 

path)

 

 

 

 

 

 

 

2107

FSC_I2C_RCV_

Message received over

I2C

100%

 

MESSAGE_TOO_BIG

I2C bus is too big

 

 

2108

FSC_I2C_MAILBOX_

I2C mailbox is full

I2C

100%

 

FULL

 

 

 

 

 

 

 

 

2109

FSC_I2C_INVALID_RCV_

Receiver address in I2C

I2C

100%

 

ADDRESS

message incorrect

 

 

 

 

 

 

 

210A

FSC_I2C_STUCK_

Pending interrupt

I2C

100%

 

INTERRUPT

status not reset

 

 

 

 

 

 

 

2200

FSC_UI_NO_RESOURCE

UI task initialization

Microcode

100%

 

 

failed

 

 

 

 

 

 

 

2201

FSC_UI_QUEUE_FULL

UI queue full

Microcode

100%

 

 

 

 

 

2202

FSC_UI_ACTION_

The UI is not in the

Microcode

100%

 

IMPOSSIBLE

correct state to perform

 

 

 

 

the requested action

 

 

 

 

 

 

 

120 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2301

FSC_BARCODE_

Timed out waiting for

Hand

100%

 

TIMEOUT

data from barcode

 

 

 

 

reader

 

 

 

 

 

 

 

2302

FSC_BARCODE_

Did not detect barcode

Hand

100%

 

READER_NOT_

reader

 

 

 

INSTALLED

 

 

 

 

 

 

 

 

2303

FSC_BARCODE_NO_

Barcode reader did not

Microcode

100%

 

READ

find a barcode

 

 

 

 

 

 

 

2400

FSC_LIBRARY_NO_

Librarian task

Microcode

100%

 

RESOURCE

initialization failed

 

 

 

 

 

 

 

2401

FSC_LIBRARIAN_BAD_

Librarian task received

 

 

 

MESSAGE

an unknown or

 

 

 

 

unexpected message

 

 

 

 

 

 

 

2402

FSC_LIBRARIAN_

Librarian queue full

Microcode

100%

 

QUEUE_FULL

 

 

 

 

 

 

 

 

2403

FSC_LIBRARIAN_SRC_

Source is empty

Microcode

100%

 

EMPTY

 

 

 

 

 

 

 

 

2404

FSC_LIBRARIAN_DEST_

Destination is full

Microcode

100%

 

FULL

 

 

 

 

 

 

 

 

2405

FSC_LIBRARIAN_BAD_

Element address

Microcode

100%

 

ELEMENT

supplied is invalid

 

 

 

 

 

 

 

2406

FSC_LIBRARIAN_

Servo initialization not

Microcode

100%

 

SERVO_INIT_FAILED

complete (Librarian

 

 

 

 

unsure of Servo status)

 

 

 

 

 

 

 

2407

FSC_LIBRARIAN_

Servo turned off due to

Microcode

100%

 

SERVO_DISABLED

failure (Librarian

 

 

 

 

unsure of Servo status)

 

 

 

 

 

 

 

2408

FSC_LIBRARIAN_DEST_

Destination slot not

Microcode

100%

 

ABSENT

present (magazine or

 

 

 

 

drive removed)

 

 

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

121

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2409

FSC_LIBRARIAN_MAG_

Magazine removed

Microcode

100%

 

REMOVED

when door was shut

 

 

 

 

 

 

 

240A

FSC_LIBRARIAN_MAG_

Magazine inserted

Microcode

100%

 

INSERTED

when no access to it

 

 

 

 

 

 

 

240B

FSC_LIBRARIAN_NO_

Demo stopped; no slot

Microcode

100%

 

FREE_SLOTS

available for cartridge

 

 

 

 

destination

 

 

 

 

 

 

 

240C

FSC_LIBRARIAN_NO_

Sequence stopped; no

Microcode

100%

 

CARTRIDGES

cartridge available to

 

 

 

 

perform requested

 

 

 

 

action

 

 

 

 

 

 

 

240D

FSC_LIBRARIAN_

Librarian uncertain of

Microcode

100%

 

ROGUE_CARTRIDGE

cartridge origin

 

 

 

 

 

 

 

240E

FSC_LIBRARIAN_

Manual intervention

Microcode

100%

 

CARTRIDGE_IN_

required to remove

 

 

 

SHUTTLE

cartridge from the

 

 

 

 

shuttle

 

 

 

 

 

 

 

240F

FSC_LIBRARIAN_

The requested move

Microcode

100%

 

ACTION_IMPOSSIBLE_

can not be performed

 

 

 

CARTRIDGE_IN_HAND

 

 

 

 

 

 

 

 

2410

FSC_LIBRARIAN_

The requested move

Microcode

100%

 

ACTION_IMPOSSIBLE_

can not be performed

 

 

 

CARTRIDGE_IN_

 

 

 

 

SHUTTLE

 

 

 

 

 

 

 

 

2411

FSC_LIBRARIAN_NO_

Auto-cleancan not be

Microcode

100%

 

CLEANING_TAPES

performed as there are

 

 

 

 

no cleaning tapes

 

 

 

 

 

 

 

2412

FSC_LIBRARIAN_

Auto-cleancan not be

Microcode

100%

 

CLEANING_TAPES_IN_

performed as all the

 

 

 

USE

cleaning tapes are in

 

 

 

 

use

 

 

 

 

 

 

 

122 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2413

FSC_LIBRARIAN_SRC_

Source slot not present

Microcode

100%

 

ABSENT

(magazine or drive

 

 

 

 

removed)

 

 

 

 

 

 

 

2414

FSC_LIBRARIAN_NO_

Demo unable to select

Microcode

100%

 

START_SLOT

random start slot (try

 

 

 

 

re-runningdemo)

 

 

 

 

 

 

 

2415

FSC_LIBRARIAN_

Move medium

Microcode

100%

 

AUTOCLEAN_IN_

attempted to drive that

 

 

 

PROGRESS

is being auto cleaned

 

 

 

 

 

 

 

2416

FSC_LIBRARIAN_BAD_

Bad parameter in

Microcode

100%

 

MESSAGE_PARAMETER

Librarian message

 

 

 

 

 

 

 

2417

FSC_LIBRARIAN_

Fixed slot reserved for

Microcode

100%

 

DEDICATED_CLEANER

dedicated cleaner; not

 

 

 

 

for general use

 

 

 

 

 

 

 

2418

FSC_LIBRARIAN_

Requested action can

Microcode

100%

 

ROBOT_NOT_READY

not be performed;

 

 

 

 

robot is busy or in use

 

 

 

 

 

 

 

2419

FSC_LIBRARIAN_

Magazine 5 present in

Microcode

100%

 

ILLEGAL_MAG_

6 drive, 7 magazine

 

 

 

INSERTED

configuration

 

 

 

 

 

 

 

241A

FSC_LIBRARIAN_NON_

Stack contains

Microcode

100%

 

HOMOGENOUS_STACK

modules configured

 

 

 

 

for different media to

 

 

 

 

stack-master

 

 

 

 

 

 

 

2500

FSC_SCSI_NO_

SCSI task initialization

Microcode

100%

 

RESOURCE

failed

 

 

 

 

 

 

 

2501

FSC_SCSI_BAD_

SCSI task received a

Microcode

100%

 

MESSAGE

bad message

 

 

 

 

 

 

 

2502

FSC_SCSI_QUEUE_FULL

SCSI queue full

Microcode

100%

 

 

 

 

 

2503

FSC_SCSI_NO_FAS366

FAS366 not detected

Servo/SCSI

100%

 

 

 

 

 

Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide

123

Appendix B Fault Symptom Code (FSC) Dictionary

FSC

Name

Description

FRU Name

Confidence %

 

 

 

 

 

2504

FSC_SCSI_INVALID_

Bad page code in send

Host

100%

 

PAGE_CODE

diagnostic

 

 

 

 

 

 

 

2600

FSC_SERVO_NO_

SERVO task

Microcode

100%

 

RESOURCE

initialization failed

 

 

 

 

 

 

 

2601

FSC_SERVO_QUEUE_

SERVO queue full

Microcode

100%

 

FULL

 

 

 

 

 

 

 

 

2602

FSC_SERVO_X_AXIS_

The X axis failed to get

 

 

 

NOT_IN_POSITION

to its target position

 

 

 

 

 

 

 

2603

FSC_SERVO_Y_AXIS_

The Y axis failed to get

 

 

 

NOT_IN_POSITION

to its target position

 

 

 

 

 

 

 

2604

FSC_SERVO_THETA_

The THETA axis failed

 

 

 

AXIS_NOT_IN_

to get to its target

 

 

 

POSITION

position

 

 

 

 

 

 

 

2605

FSC_SERVO_PICKER_

The PICKER axis failed

 

 

 

AXIS_NOT_IN_

to get to its target

 

 

 

POSITION

position

 

 

 

 

 

 

 

2606

FSC_SERVO_SHUTTLE_

The Shuttle axis failed

 

 

 

AXIS_NOT_IN_

to get to its target

 

 

 

POSITION

position

 

 

 

 

 

 

 

2607

FSC_SERVO_Z_AXIS_

The Z axis failed to get

 

 

 

NOT_IN_POSITION

to its target position

 

 

 

 

 

 

 

2608

FSC_SERVO_X_TACHO_

The X axis tacho

System PWA

100%

 

COUNTER_FAILURE

counter failed to clear

 

 

 

 

at power-on

 

 

 

 

 

 

 

2609

FSC_SERVO_Y_TACHO_

The Y axis tacho

System PWA

100%

 

COUNTER_FAILURE

counter failed to clear

 

 

 

 

at power-on

 

 

 

 

 

 

 

260A

FSC_SERVO_THETA_

The Theta axis tacho

Hand PWA

80%

 

TACHO_COUNTER_

counter failed to clear

System PWA

20%

 

FAILURE

at power-on

 

 

 

 

 

 

 

 

124 Sun StorEdge™ L25 Tape Library and Sun StorEdge™ L100 Tape Library User’s Guide