PVI Industries 1000PHE125A-TPGO, 750PHE125A-TPGO, 1500PHE125A-TPGO, 1250PHE125A-TPGO User Manual

0 (0)
PVI Industries 1000PHE125A-TPGO, 750PHE125A-TPGO, 1500PHE125A-TPGO, 1250PHE125A-TPGO User Manual

 

 

TURBOPOWERGAS/OIL

PACKAGED WATER HEATER

 

 

 

 

 

 

 

POLYSHIELDPOLYMER-LINED STORAGE TANK

 

 

 

 

 

 

 

 

 

 

 

TANK SERIES 125 GALLONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recovery gph

 

Min. Inlet Flow

 

Dimensions (inches)

 

Blower

Shipping

 

Model

 

Input

#2 Oil

 

Motor

 

Number

 

 

 

 

Btu/h

Gas Pressure

gph

 

 

 

 

 

 

 

 

Weight

 

 

 

 

 

 

 

 

 

 

 

 

Volt/Ph/

 

 

40°- 120°F

40°- 140°F

"W.C.

A

B

C

J

HP

 

lbs

 

 

 

 

 

 

Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

PHE 125A-TPGO

 

750

600

 

600,000

 

4.5

4.3

42

6

1

31

1/2

 

115/1 /10

1420

1000

PHE 125A-TPGO

 

1000

800

 

800,000

 

6.0

5.7

42

8

1

31

1/2

 

115/1 /10

1460

1250

PHE 125A-TPGO

 

1250

1000

 

1,000,000

 

7.5

7.2

42

8

1

31

3/4

 

115/1 /14

1550

1500

PHE 125A-TPGO

 

1500

1200

 

1,200,000

 

7.5

8.6

42

8

1-1/4

31

1

 

115/1 /16

1630

Recoveries based on 83% thermal efficiency. “J” dimension is for the burner housing only. Standard gas train.

ASHRAE 90.1 compliant for efficiency and standby loss. Gas train may exceed this dimension.

*The information presented is for Natural gas 0.6 S.G.— For operation with propane (LP gas), consult factory. Dimensions are in inches unless otherwise specified.

Burner control panel requires 18" clearance for door swing. For standard and optional equipment, see form PV 6047.

* GAS PRESSURE REQUIREMENTS

SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.

MAXIMUM STATIC INLET PRESSURE: 14" W.C.

FOR PRESSURES OTHER THAN LISTED, CONSULT FACTORY.

Pressure shown is for standard UL gas train. Additional controls may increase pressure requirements.

VENTING REQUIREMENTS

-.02" TO -.06" W.C. (NEGATIVE PRESSURE)

ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE VENT CONNECTION DIAMETER EXCLUSIVELY.

FOR PROPER SIZING, CONSULT

THE NATIONAL FUEL GAS CODE UNDER “FAN-ASSISTED.”

* REAR ACCESS MODULE

MODEL PREFIX

M

L

STD or OPTIONAL

 

 

 

 

750-1500

23"

N/A

OPTIONAL

 

 

 

 

 

 

 

 

STANDARD ELECTRICAL REQUIREMENTS

CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS. MOTOR VOLTAGE:

208V, 230V, AND 460V MOTORS ARE AVAILABLE BUT WILL REQUIRE A SEPARATE 120V/2 amps CONTROL CIRCUIT OR AN OPTIONAL CONTROL CIRCUIT TRANSFORMER.

PVI RESERVES THE RIGHT TO CHANGE THE DESIGN

AND SPECIFICATION WITHOUT NOTICE.

PVI INDUSTRIES, LLC

FORT WORTH, TEXAS 76111

PV 5477 02/04

(800) 784-8326 (817) 335-9531 www.pvi.com

Product is patented in the U.S., Canada, and Mexico.

 

 