Pelco EM3512, EH3515, EH3515-2HD-MT, EH3515-2HD, EH3515-2-MT User Manual

...
0 (0)

 

 

I N S TA L L AT I O N MANUAL

 

 

EM3512 Feedthrough

 

 

 

 

Wall Mount for EH3512 Series

®

 

24 VAC Enclosures

 

 

 

C268M-B (8/05)

IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

6.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

7.Only use attachments/accessories specified by the manufacturer.

8.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

9.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, the apparatus does not operate normally, or the apparatus has been dropped.

10.To reduce the risk of shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

11.Unless the unit meets NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P standards, it is designed for indoor use only and must not be installed where exposed to rain and moisture.

12.Only use parts recommended by Pelco.

13.The installation methods and materials should be capable of supporting four times the weight of the mount, enclosure, and camera and lens combination.

14.Use stainless steel hardware to fasten the enclosure to outdoor surfaces.

15.To prevent water leakage when installing a mount outdoors, apply sealant around the bolt holes between the mount and the mounting surface.

16.Installation should be done only by qualified personnel and conform to all local codes.

17.Only EH3512 enclosures that use 24 VAC can be installed on the EM3512.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.

2

C268M-B (8/05)

DESCRIPTION

The EM3512 Feedthrough Wall Mount provides an attractive mount for the following EH3512 enclosures that use 24 VAC power:

EH3512 enclosure when a 24 VAC camera is installed

EH3512-2 enclosure

EH3512-2HD enclosure

Video and power wiring are pre-installed and concealed within the mount.

NOTE: The EM3512 mount cannot be used with the EH3508 Series and EH3515 Series enclosures.

C268M-B (8/05)

3

Pelco EM3512, EH3515, EH3515-2HD-MT, EH3515-2HD, EH3515-2-MT User Manual

INSTALLATION

The following parts are supplied:

EM3512 mount 5/32-inch hex wrench

Two 1/4-20 x 5/8-inch Phillips screws

24 VAC POWER WIRING

FEMALE BNC

 

 

 

CONNECTOR

 

 

24 VAC POWER WIRING

SCREW HOLES TO

 

 

 

ATTACH EH3512

 

 

 

TILT ADJUSTING

 

 

 

SCREW

 

 

 

 

 

 

MALE BNC

PAN ADJUSTING

 

 

CONNECTOR

SCREW

CONDUIT

 

 

 

 

WALL PLATE

 

FITTING

WALL PLATE

 

 

FASTENING

SCREW

Figure 1. EM3512 Feedthrough Wall Mount

INSTALL THE WALL PLATE

1.Use the supplied 5/32-inch hex wrench to remove the wall plate

fastening screw on the bottom, rear of the mount, and then rethread the screw a couple of turns (refer to Figure 1). Remove the wall plate by prying out the bottom of the plate (refer to Figure 2).

2. Attach the wall plate to a wall,

 

electrical box, PA3512 Pole Mount

 

Adapter, or CM3512 Corner Mount

Figure 2. Removing Mount from Wall Plate

Adapter.

 

Refer to Table A for recommended minimal hardware requirements when attaching the wall plate to a wall or electrical box. Hardware is supplied with the pole and corner mount adapters for attaching the wall plate.