EuroSys 12PM
Powered Monitor Enclosure
OPERATING INSTRUCTIONS
EuroSys 12PM
Powered Monitor Enclosure
OPERATING INSTRUCTIONS
WARNING! TO PREVENT SHOCK OR FIRE HAZARD DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. DO NOT REMOVE FROM CASE. NO USER SERVICEABLE PARTS INSIDE. REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL. REPLACE FUSE ONLY WITH ONE OF THE SAME TYPE AND SPECIFICATION.
Thank you for choosing Peavey's Eurosys 12PM powered monitor enclosure as part of your sound reinforcement system. We take great pride in the design and manufacture of our units and you can expect top performance and reliability. Your Eurosys 12PM has been rigorously tested before packing and despatch to your dealer. It has been designed to run from a nominal 230 Volt AC mains supply.
1.AMPLIFIER INPUTS
Use to connect line level signals from the monitor send of the mixer. Two sockets are provided to allow connection to further Eurosys 12PM powered monitors. (Daisy chaining).
2.VOLUME
This slider controls the level or volume of the enclosure.
3.4 BAND GRAPHIC EQUALISER
Four sliders allowing up to +/- 12dB of adjustment at the centre frequencies of: - 100Hz , 1KHz , 5KHz and 10KHz. Use to assist with any feedback problems.
4.~ PILOT LIGHT
Illuminates when AC mains power is being supplied to the amplifier.
5.EXTENSION SPEAKER SOCKET
Allows connection of a further unpowered monitor such as the Peavey Eurosys 12M having a minimum impedance of 8 ohms. The power amplifier will develop full power into 4 ohms. (100 Watts).
6.POWER SWITCH
Use to turn the Eurosys 12PM ON or OFF
7.MAINS CONNECTOR & FUSE HOLDER
An IEC 320 combined mains connector and fuse holder is fitted. A separate 3-wire mains cord fitted with a moulded plug is supplied.
8 . 13 AMP PLUG REPLACEMENT
As the colours of the wires in the mains lead or cord of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
-the wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol, or coloured green or green yellow.
-the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
-the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
WARNING - THIS APPARATUS MUST BE EARTHED |
|
SPECIFICATIONS |
|
POWER OUTPUT (TYPICALLY) |
POWER REQUIREMENTS |
68 Watts into 8 ohms |
225 Watts at 100 Watts output |
100 Watts into 4 ohms |
|
INPUT SENSITIVITY |
MAINS VOLTAGE REQUIREMENTS |
0.525 volt for 68 Watts into 8 ohms |
230 Volts AC (only) 50/60 Hz |
FUSE RATING |
|
1 ampere anti surge. |
|
IN CASE OF DIFFICULTY CONSULT YOUR AUTHORISED PEAVEY DEALER
Due to our efforts for constant improvement, features and specifications are subject to change without notice.
EuroSys 12PM
Enceinte de retour amplifiée
MANUEL D’UTILISATION
ATTENTION, AFIN DE PREVENIR TOUT RISQUE DE CHOC ELECTRIQUE OU DE FEU, NE PAS EXPOSER CE MATERIEL A LA PLUIE OU A L’ HUMIDITE. NE PAS OUVRIR LE CHASSIS, IL NE CONTIENT AUCUNE PIECE UTILISABLE. FAIRE EFFECTUER LES REPARATIONS PAR UNE PERSONNE QUALIFIEE. REMPLACER LE FUSIBLE PAR UN MODEL DU MEME TYPE.
Nous vous remercions d’avoir choisi l’enceinte de retour amplifiée Eurosys 12PM . Nous sommes trés fier de la conception et de la réalisation de ces enceintes d’un excellent rendement et d’une grande fiabilité. Votre enceintes EuroSys 12PM a été soumise à des essais rigoureux avant d’être conditionnée et expédiée à votre revendeur. Elle doit être alimentée en 230V AC.
1.ENTREES DE L’AMPLIFICATEUR
Connectez la sortie au niveau ligne ‘monitor’ de votre table de mixage à ces entrées. Deux prises en parallèle sont fournies pour permettre le chaînage d’enceintes EuroSys 12PM.
2.VOLUME
Ceréglage autorise le contrôle du volume sonore de l’enceinte.
3.EQUALISEUR GRAPHIQUE 4 BANDES
4 faders autorisant une correction de + ou - 12 dB à 100Hz, 1KHz, 5KHz, 10KHz. Employez ces contrôles pour corriger tout problème de feedback.
4.LED DE MISE SOUS TENSION
Cette diode s’allume lorsque l’amplificateur est alimenté.
5.FICHE POUR EXTENSION
Elle permet la connection de l’EuroSys 12PM à d’autres enceintes non amplifiées d’une impédance minimum de 8 Ohm tel l’EuroSys 12M. L’amplificateur de puissance developpera sa pleine puissance (100 Watt) sous 4 Ohm.
6.INTERRUPTEUR D’ALIMENTATION
Met l’EuroSys 12PM en et hors fonction.
7.PRISE D’ALIMENTATION ET FUSIBLE
Cette prise, accompagnée d’un porte-fusible, permet la connection du cordon d’alimentation IEC fourni.
ATTENTION – CET APPAREIL DOIT ETRE RELIE A LA TERRE
SPECIFICATIONS |
|
PUISSANCE NOMINALE |
PUISSANCE NECESSAIRE |
68 Watt continus sous 8 Ohm |
225 Watt pour une puissance de sortie de 100 Watt |
100 Watt continus sous 4 Ohm |
|
SENSIBILITE D’ENTREE |
ALIMENTATION |
0,525V pour 68 Watt sous 8 Ohm |
230V AC 50/60Hz uniquement |
FUSIBLE |
|
1 Ampère, fusible retardé. |
|
EN CAS DE DIFFICULTÉS, CONSULTEZ VOTRE REVENDEUR PEAVEY
Etant donnée notre politique de développement continu, les caractéristiques et spécifications sont sujets à des modifications sans préavis.