Panasonic SD48C90JBU6 User Manual

4 (1)
Panasonic SD48C90JBU6 User Manual

MATSUSHITA Compressor

Single Phase

115 V

MODEL# SD48C90JBU6 (VG10)

 

R-134a

60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Range . . . . . . . . .

103 Volts to 127 Volts @ 60 Hz

Refrigerant Control Capillary Tube. .

 

Application . . . . . . . . . . . .

Low Back Pressure

Evaporator

 

 

Compressor Cooling . . . .

Static Cooling

Temp. Range .

. . . . . . -31°F to 23°F / -35°C to -5°C

Rated Performance Data

Capacity . . . . . . . . . . . . . . 546 Btu/h ±7% *

E.E.R. . . . . . . . . . . . . . . . . . 4.67 Btu/Wh ±10% *

Current . . . . . . . . . . . . . . . 1.07 Amps *

Nominal Motor Data

Motor Input . . . . .

117 Watts*

 

Rated Current . . .

1.16 Amps

 

Type . . .

. . . . . . .

RSCR, PTC relay

 

 

 

Locked Rotor . . . . . . . . . .

8.97 Amps

 

Start Current . . . . . . . . . .

15.73 Amps

 

Coil Resistances

Run . . . .

3.82 Ohms

@ 68°F (20°C)

Start . . .

6.66 Ohms

*Test Conditions for Performance Specifications

Test Oil . . . . . . . . . . . . . . .

. Freol α 10

Shell Temp . . . . . . . . . . . . . .

150.0°F / 65.0°C

Condensing Temp . . . . . . . . .

130.0°F / 54.4°C

Evaporating Temp . . . . . . . . .

-10.0°F / -23.3°C

Ambient Temp . . . . . . . . . . . .

90.0°F / 32.2°C

Gas Superheat . . . . . . . . . . .

90.0°F / 32.2°C

Liquid Sub-Cooling . . . . . . . .

90.0°F / 32.2°C

Electrical Accessories

Overload Protector

Nominal Operating Characteristics

Model Name

 

T135AH6.1

 

 

Manufacturer

 

Matsushita

 

 

Temperature To . . . . . . . . . . . Open: 275°F ± 9°F / 135°C ± 5°C

 

 

Close: 176°F ± 27°F / 80°C ± 15°C

Trip Current . . . . . . . . . . . . . . @212°F (100°C) 4.1 to 5.1 Amps

 

 

@77°F (25°C) 16.5 Amps @ 13 sec. max.

 

 

 

 

P.T.C. Starting Device

 

 

 

Nominal Operating Characteristics

 

 

 

 

 

 

Model Name

MM8-5DCP4M7

PTH7M4R7MD2

Manufacturer

Matsushita

Murata Mfg.

 

Base resistance

 

 

 

 

@ 77°F(25°C) ±20%

 

4.7

4.7

Ohms

Power Consumption (max)

3.3

3.0

Watts

Operation time

 

1.3 to 3.0

0.7 to 2.2

seconds

Recovery time (max)

 

65

70

seconds

 

 

 

 

Run Capacitor

 

12 µF 180 V (min.)

 

 

 

 

 

 

†Although these accessories are listed by UL/CSA for use with this compressor, Matsushita assumes no responsibility whatsoever for these or any other components sourced by the refrigeration system manufacturer from third parties.

Performance Curves

(W)

170

 

 

 

 

150

 

 

 

 

Power

 

 

 

 

130

 

 

 

 

110

 

 

 

 

Input

90

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

-30

-20

-10

0

10

 

1.5

 

1.4

(A)

1.3

1.2

Current

1.1

1.0

0.9

 

 

0.8

 

0.7

 

-30

-20

-10

0

10

 

1,100

 

 

 

 

 

1,000

 

 

 

 

(BTU/H)

900

 

 

 

 

800

 

 

 

 

700

 

 

 

 

Capacity

600

 

 

 

 

500

 

 

 

 

400

 

 

 

 

300

 

 

 

 

 

 

 

 

 

 

200

 

 

 

 

 

-30

-20

-10

0

10

Evaporating Temperature (°F)

110°F 120°F 130°F

9 – Point Data

 

 

 

 

 

Evaporating Temp.

Condensing Temp.

 

Rating

 

-30°F

 

-10°F

 

+10°F

 

 

 

 

 

 

130°F

 

Btu/h

 

239

 

546

 

983

 

 

 

Watts

 

77

 

117

 

160

 

 

 

Amps

 

0.75

 

1.07

 

1.46

 

 

 

E.E.R.

 

3.10

 

4.67

 

6.14

 

120°F

 

Btu/h

 

280

 

577

 

1,011

 

 

 

Watts

 

80

 

116

 

155

 

 

 

Amps

 

0.78

 

1.07

 

1.42

 

 

 

E.E.R.

 

3.50

 

4.97

 

6.52

 

110°F

 

Btu/h

 

311

 

604

 

1,038

 

 

 

Watts

 

82

 

113

 

149

 

 

 

Amps

 

0.79

 

1.06

 

1.37

 

 

 

E.E.R.

 

3.79

 

5.35

 

6.97

 

®

Panasonic Industrial Company

 

Panasonic

Refrigeration Products Department

 

Tel: 201 - 392 - 4249

 

Fax: 201 - 392 - 4315

Rev#1-5/9