MICRO-IMAGECHECKER ® A210•A110 MultiChecker V2 Series
■ System configuration diagram ■ Vision Backup-Tool Ver.2
|
|
*1 |
|
|
Controller |
|
ENTER |
PC |
A |
B |
|
|
C |
Keypad |
|
|
Serial cable |
|
|
Monitor cable |
|
|
(Pin-BNC) |
|
|
PLC (refer to P5) |
|
|
V-HOLD BLIGHT CONTRAST |
|
Panasonic |
|
|
|
Video Monitor GP-BM |
|
Monitor |
The product data created with the MICRO-IMAGECHECKER A series and the image data stored in the controller can be stored on a PC using Windows.
Stored data can be restored to the A series controller.
*However, it is not possible to directly restore type data backed up using Vision Backup-Tool with the previous product (Ver. 1) to V2 (Ver. 2). In
this case, use the dedicated data conversion software (freeware) to convert the Ver. 1 type data for V2 use, then transfer it to V2 and perform a backup again. If you require the data conversion software, contact your Matsushita Automation Controls Co. Ltd. representative.
|
|
|
High-speed |
High-speed |
|||||||||||
|
|
|
random cable |
random trigger camera Lens |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Camera extension cable |
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Middle ring |
||||||
|
|
|
|
|
|
|
|
||||||||
*2 |
|
|
|
|
CS mount camera |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*1 The A100 series connects to one camera. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*2 Use where necessary. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*3 |
|
|
|
|
|
|
|
|
|
*3 When using 2 cameras with the A200 series, |
|||||
|
|
|
|
|
|
|
|
|
connect the same type of camera. |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
■ Table of Product Numbers
● MICRO-IMAGECHECKER A-Series Controller
|
Item |
Specifications |
Part No. |
||
|
|
|
|
|
|
|
|
A210 |
NPN Output |
ANMA212V2 |
|
|
MICRO-IMAGECHECKER |
Multi-Checker V2 : CE |
PhotoMos Output |
ANMA218V2 |
|
|
A200 Series |
A210 |
NPN Output |
ANMA212 |
|
|
|
|
|||
|
|
Multi-Checker : CE |
|
||
|
|
|
|
|
|
|
|
A110 |
NPN Output |
ANMA112V2 |
|
|
MICRO-IMAGECHECKER |
Multi-Checker V2 : CE |
PhotoMos Output |
ANMA118V2 |
|
|
A100 Series |
A110 |
NPN Output |
ANMA112 |
|
|
|
|
|||
|
|
Multi-Checker : CE |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
● Camera / Keypad / Monitor
|
Item |
Specifications |
Part No. |
|
|
C mount camera |
Progressive Double-speed Random: CE |
ANM831 |
|
|
CS mount camera |
support electric-shutter with 3 m cable |
ANM832 |
|
|
|
support electric-shutter with 3 m cable: CE |
ANM832CE |
|
|
Keypad |
with 2 m cable |
ANM85202 |
|
|
|
with 3 m cable |
ANM85203 |
|
|
|
with 2 m cable: CE |
ANM85202CE |
|
|
|
with 3 m cable: CE |
ANM85203CE |
|
|
Monitor |
Panasonic GPBM910 (100 V AC/12 V DC) |
AUGPBM910 |
|
|
|
|
|
|
● Camera cable
Item |
|
Specifications |
|
Part No. |
Double-speed random |
3 m |
|
ANM84303 |
|
camera cable |
|
3 m: CE |
|
ANM84303CE |
|
|
|
||
Camera extension cable |
2 m extension: total 5 m |
|
ANM84002 |
|
|
|
7 m extension : total 10 m |
|
ANM84007 |
|
|
12 m extension: total 15 m |
|
ANM84012 |
|
|
17 m extension: total 20 m |
|
ANM84017 |
|
|
2 m extension : total 5 m: CE |
|
ANM84002CE |
|
|
7 m extension: total 10 m: CE |
|
ANM84007CE |
|
|
12 m extension: total 15 m: CE |
|
ANM84012CE |
|
|
17 m extension: total 20 m: CE |
|
ANM84017CE |
● Serial Cable |
|
|
|
|
Item |
|
Specifications |
Part No. |
|
COM port |
COM port and PC (D-SUB : 9 pin) connection, 3 m |
ANM81103 |
||
connecting cable |
COM port and PLC (discrete-wire cable) connection, 3 m |
ANM81303 |
||
TOOL port |
COM port and PC (D-SUB : 9 pin) connection, 10 cm |
ANM812001 |
||
connecting cable |
||||
|
|
|
|
|
● Lens / middle ring
Item |
Specifications |
Part No. |
CS mount lens |
f2.8 CS mount compact lens |
ANM8828 |
|
f2.8 CS mount compact lens with lock |
ANM88281 |
|
f4 CS mount compact lens |
ANM8804 |
|
f4 CS mount compact lens with lock |
ANM88041 |
|
f8 CS mount compact lens |
ANM8808 |
|
f8 CS mount compact lens with lock |
ANM88081 |
C mount lens |
f6.5 C mount lens |
ANB842 |
|
f8.5 C mount lens |
ANB843 |
|
f8.5 C mount lens with lock |
ANB843L |
|
f16 C mount compact lens |
ANB845N |
|
f16 C mount compact lens with lock |
ANB845NL |
|
f25 C mount compact lens |
ANB846N |
|
f25 C mount compact lens with lock |
ANB846NL |
|
f50 C mount lens |
ANB847 |
|
f50 C mount lens with lock |
ANB847L |
|
f50 C mount compact lens |
ANM8850 |
|
f50 C mount compact lens with lock |
ANM88501 |
Middle ring |
5 mm middle ring |
ANB84805 |
|
(0.5/1/5/10/20/40 mm) middle ring |
ANB848 |
● Data backup software
Item |
Specifications |
Part No. |
Vision Backup-Tool Ver.2 |
English version |
ANM70131V2 |
Microsoft windows NT4.0/95/98/Me/2000 compatible. An operating system is not included with this software.
● Accessories
Item |
Specifications |
Part No. |
I/O terminal block |
For input: 1 piece, for output, 1 piece |
ANMA8001 |
BNC connector |
Monitor BNC jack to PIN jack adapter |
ANM8606 |
Unless otherwise specified, estimate and delivery prices do not include technician dispatching and other related services. Therefore, for the situations given below, additional charges
may be added.
• Installation and trial operation guidance • Inspections, adjustments, and repairs
• Technical support and instruction
To USA Customer
•Products sold by seller are covered by the warranty and patent indemnification provisions in its Terms and Conditions of Sale only.
These materials are printed on ECF pulp.
These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
Image Processing Device
MICRO-IMAGECHECKER®
A210• A110
MultiChecker Ver.2 Series
It won’t stop advancing. The monstrously small A Series!
Matsushita Electric Works, Ltd. Automation Controls Company |
COPYRIGHT © 2001 All Rights Reserved |
|
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan |
|
Specifications are subject to change without notice. |
ARCT1B178E 200111-2YT |
11/2004 |
11/2004 |
|
The MultiChecker V2 Series - more powerful than ever!
Our highly acclaimed, compact A210 and A110 MultiChecker image processing units are now even more powerful! The V2 (Ver. 2) upgrade includes new functions for even greater convenience. To meet your diverse range of inspection requirements, we have increased the number of checkers by a factor of three. In addition to making more inspection locations possible, they now come equipped with a new mode that allows two-level branch inspection using one image checker, and an extensive range of functions that allow use in a wide range of applications.
Three times the processing capacity
of their predecessors! Designed to meet a diverse variety of
inspection needs!
You can now register three times more checkers per type!
●A210 MultiChecker: increased from 32 to 96
●A110 MultiChecker: increased from 16 to 48
Possible to choose from three execution modes to suit your
inspection requirements!
MICRO
Automatic Switch Mode
Branch inspection without complicated settings provides great convenience!
Example
It is possible to first make a direction judgment, and then perform a separate inspection (character appearance or mark width measurement) based on this direction.
Conventional method
●Execute all checkers and output results
●Perform direction judgment externally and compare results
Execution time: 65msec.
Automatic Switch Mode
●Perform direction judgment and execute the required checker
Execution time: 35msec! |
Execution time |
reduced by half! |
Detect the direction |
|
Execute block 1 |
|||||||||
judgment marker |
|
|
(5 msec) |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Normal direction |
Direction judgment |
Reverse direction |
||||
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||
Execute Block 2 |
|
|
|
Execute Block 3 |
||
(30msec) |
|
|
|
(30msec) |
||
|
|
|
|
|
|
|
New
User-Defined Mode
Multiple inspections of up to three blocks with no switching time!
Example
When you wish to perform multiple continuous inspections because the work will not fit in the field of view of a single image capture.
Conventional method
|
●Handled by type switching using an external device. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
●Type switching requires time and usage restrictions |
Type switching not required! |
|
|
|
|
|
|
|
|
Type 1 |
Type 2 |
Type 64 |
||||||
|
apply. |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
User-Defined Mode
●Internally switches to the process block via an |
|
|
|
external signal. |
|
|
|
●External device is not used, so inspection time is |
|
|
|
greatly reduced! |
|
|
|
*Can be executed from the keypad as well. |
First field of vision |
Second field of vision |
Third field of vision |
|
(Block 1) |
(Block 2) |
(Block 3) |
Execute All Mode
Three times the number of checkers can now be registered per type, so you can inspect many points at one time!
Example
Multiple simultaneous point inspection possible for applications such as inspecting LED lighting.
Plenty of external outputs for judgment results (96 points for the A210 and 48 points for the A110) allow simultaneous output of judgment results for multiple inspection points.
2 |
11/2004 |
3 |
|
11/2004 |