Ordering Information

 

 

 

Specifications

 

Current consumption (A)

 

 

Product

 

I/O capacity/Mountable

Program

 

LD instruction

 

 

 

 

Model

Standards

name

 

Units (Expansion

Data memory capacity

execution

5 V

24 V

 

capacity

 

 

 

 

Racks)

 

speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

448K words

 

0.99

 

 

 

 

 

 

 

 

250K steps

DM: 32K words

 

 

 

 

CJ1H-CPU67H-R

 

 

 

 

 

(See note.)

 

 

 

 

 

 

 

 

EM: 32K words x 13 banks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256K words

 

0.99

 

 

 

 

 

 

 

 

120K steps

DM: 32K words

 

 

 

 

CJ1H-CPU66H-R

 

 

 

2,560 points/40 Units

 

(See note.)

 

 

 

 

 

 

 

EM: 32K words x 7 banks

 

 

 

 

 

 

CJ1-H-R

 

max.

 

0.016 μs

 

 

 

 

 

UC1, CE, N, L

 

 

 

 

 

 

 

 

CPU Units

 

(3 Expansion Racks

 

128K words

0.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max.)

60K steps

DM: 32K words

 

 

 

 

CJ1H-CPU65H-R

 

 

 

 

(See note.)

 

 

 

 

 

 

 

 

EM: 32K words x 3 banks

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

64K words

 

0.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30K steps

DM: 32K words

 

 

 

 

CJ1H-CPU64H-R

 

 

 

 

 

(See note.)

 

 

 

 

 

 

 

 

EM: 32K words x 1 bank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Current consumptions include current for a Programming Console. Add 0.15 A per Adapter when using NT-AL001 RS-232C/RS-232A Adapters. Add 0.04 A per Converter when using CJ1W-CIF11 RS-422A Converters.

International Standards:

The standards indicated in the "Standards" column are those current for UL, CSA, cULus, cUL, NK, and Lloyd standards and EC Directives as of the end of March 2007. The standards are abbreviated as follows: U: UL: U1: UL (Class I Division 2 Product for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Product for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, CE: EC Directives.

Ask your OMRON representatives for the conditions under which the standards were met.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

Note: Do not use this document to operate the Unit.

This catalog mainly provides information that is necessary for selecting suitable models, and does not contain precautions for correct use. Always read the precautions and other required information provided in product operation manuals before using the product.

The application examples provided in this catalog are for reference only. Check functions and safety of the equipment before use.

Never use the products for any application requiring special safety requirements, such as nuclear energy control systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, or other application involving serious risk to life or property, without ensuring that the system as a whole has been designed to address the risks, and that the OMRON products are properly rated and installed for the intended use within the overall equipment or system.

Printed on 100%

Recycled Paper

OMRON Corporation

OMRON ELECTRONICS LLC

Industrial Automation Company

1 East Commerce Drive, Schaumburg,

IL 60173 U.S.A.

Control Devices Division H.Q.

Tel: (1)847-843-7900/Fax: (1)847-843-8568

Shiokoji Horikawa, Shimogyo-ku,

 

Kyoto, 600-8530 Japan

OMRON ASIA PACIFIC PTE. LTD.

Tel: (81)75-344-7109

83 Clemenceau Avenue,

Fax: (81)75-344-7149

#11-01, UE Square,

Regional Headquarters

Singapore 239920

Tel: (65)6835-3011/Fax: (65)6835-2711

OMRON EUROPE B.V.

OMRON (CHINA) CO., LTD.

Wegalaan 67-69, NL-2132 JD Hoofddorp

Room 2211, Bank of China Tower,

The Netherlands

200 Yin Cheng Zhong Road,

Tel: (31)2356-81-300/

PuDong New Area, Shanghai, 200120 China

Fax: (31)2356-81-388

Tel: (86)21-5037-2222/Fax: (86)21-5037-2200

Authorized Distributor:

Note: Specifications subject to change without notice.

Cat. No. R148-E1-01

 

Printed in Japan

 

0507

Programmable Controllers

CJ1H CPU6 H R High-speed CPU Units

New Flagship "R" CPU Units: Faster Than Ever

Loading...
+ 1 hidden pages