Omron HEM-711DLX User Manual 2

0 (0)
Omron HEM-711DLX User Manual 2

INSTRUCTION MANUAL

Automatic Blood Pressure Monitor

with ComFitTM Cuff

Model HEM-711DLX

ENGLISH ESPAÑOL

TABLE OF CONTENTS

Before Using the Unit

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Operating Instructions

Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Irregular Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Average Value Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Movement Error Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15

Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26

Care and Maintenance

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . .31

FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

2

Before Using the Unit

INTRODUCTION

Thank you for purchasing the Omron® HEM-711DLX IntelliSense® Automatic Blood Pressure Monitor with ComFitTM Cuff.

Fill in for future reference.

DATE PURCHASED: __________________

SERIAL NUMBER: ____________________

Staple your purchase receipt here

Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. The monitor stores measurement results.

The HEM-711DLX comes with the following components:

• Monitor

• ComFitTM Cuff

• AC Adapter

• Storage Case

• Warranty Card

 

• Instruction Manual printed in English and Spanish

The HEM-711DLX IntelliSense® Automatic Blood Pressure Monitor is intended for home use.

SAVE THESE INSTRUCTIONS

3

SAFETY INFORMATION

To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

Indicates a potentially hazardous situation

WARNING which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation

which, if not avoided, may result in minor or CAUTION moderate injury to the user or patient or

damage to the equipment or other property.

OPERATING THE DEVICE

Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.

If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.

Read all of the information in the instruction manual and any other literature in the box before operating the unit.

This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.

Read the Special Conditions section (page 25) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.

4

SAFETY INFORMATION

OPERATING THE DEVICE (continued)

Operate the device only as intended. Do not use the device for any other purpose.

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Do not use a cellular phone near the device. It may result in an operational failure.

Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.

Use only 1.5 V manganese or alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.

RISK OF ELECTRICAL SHOCK

Do not plug or unplug the power cord into the electrical outlet with wet hands.

Do not overload power outlets. Plug the device into the appropriate voltage outlet.

5

SAFETY INFORMATION

CARE AND MAINTENANCE

Do not subject the monitor to strong shocks, such as dropping the unit on the floor.

Do not submerge the device or any of the components in water.

Store the device and the components in a clean, safe location.

Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.

6

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:

1.Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement.

2.Stress raises blood pressure. Avoid taking measurements during stressful times.

3.Measurements should be taken in a quiet place.

4.Remove tight-fitting clothing from your arm.

5.Sit in a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.

6.Remain still and do not talk during the measurement.

7.Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.

8.Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.

7

Operating Instructions

KNOW YOUR UNIT

Main Unit:

Display

 

Battery Compartment

 

START/STOP Button

 

MEMORY Button

Air Jack

 

Date/Time Setting Button

AC Adapter Jack

Components:

 

 

Air Tube

 

 

 

Housing

 

 

 

Storage Case

Air Plug

 

INSTRUCTION MANUAL

 

Automatic Blood Pressure Monitor

 

 

with ComFit Cuff

 

 

Model HEM-711DLX

(Connects to Air Jack)

Cord

 

Arm Cuff

 

AC Adapter

Instruction Manual

 

 

 

8

UNIT DISPLAY

Systolic Blood Pressure

Diastolic Blood Pressure

 

Memory Symbol

Heartbeat Symbol

Average Value Symbol

Pulse Display

Movement Error Symbol

Deflation Symbol

Date/Time Display

 

Low Battery Indicator

 

 

Irregular Heartbeat Symbol

9

DISPLAY SYMBOLS

IRREGULAR HEARTBEAT SYMBOL ()

When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol () will appear on the display with the measurement values.

An irregular heartbeat rhythm is defined as a rhythm that is more than 25 % slower or 25 % faster from the average rhythm detected while the monitor is measuring the systolic blood pressure and the diastolic blood pressure.

If the Irregular Heartbeat Symbol () displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.

Normal Heartbeat

Pulse

Blood pressure

Irregular Heartbeat

Short Long

Pulse

Blood pressure

AVERAGE VALUE SYMBOL ( )

The Average Value Symbol is displayed if the measurement values displayed are an average of up to three measurements taken within 10 minutes of the last reading.

MOVEMENT ERROR SYMBOL ( )

The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement.

10

DISPLAY SYMBOLS

The American Heart Association1 recommends the following guideline for upper limit of normal for home blood pressure readings:

AHA Home Guideline for Upper Limit of Normal BP

Systolic Blood Pressure

135 mmHg

Diastolic Blood Pressure

85 mmHg

This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure1.

The monitor is not intended to be a diagnostic device.

WARNING

Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.

Omron Healthcare recommends you contact your physician if the HEARTBEAT SYMBOL appears on the display with your measurement values.

HEARTBEAT SYMBOL ( )

TAKING A MEASUREMENT

The Heartbeat Symbol flashes on the display during

the measurement.The Heartbeat Symbol flashes at every heartbeat.

When the measurement is complete, the Heartbeat Symbol flashes on the display with your blood pressure and pulse rate if the reading is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.

11

DISPLAY SYMBOLS

USING THE MEMORY FUNCTION

The Heartbeat Symbol flashes when the blood pressure reading stored in the memory is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value.

12

BATTERY INSTALLATION

1.Press the indicator on the battery cover and slide the cover off in the direction of the arrow.

2.Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match

the polarities of the battery compartment as indicated.

3. Replace the battery cover.

Battery Cover

13

BATTERY INSTALLATION

BATTERY REPLACEMENT

Low Battery Indicator

When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended.

CAUTION

If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.

NOTES: • Turn the unit off before replacing the batteries. If the batteries are removed while the unit is still on, the date and time will be reset to that of the previous use. However, the measurement results are not deleted.

When the batteries are replaced, you may need to reset the date and time. If the year is flashing on the display screen, refer to page 16, SETTING THE DATE AND TIME.

CAUTION

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

14

USING THE AC ADAPTER

NOTES: • Use only the authorized Omron AC Adapter, Model Number HEM-ADPT1,with this monitor.

We recommend you install the batteries even if the AC Adapter is used. If no batteries are installed, you may need to reset the date and time if the AC Adapter is disconnected. The measurement results will not be deleted.

CAUTION

Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.

TO CONNECT THE AC ADAPTER

Insert the AC Adapter Plug into the AC Adapter Jack on the back side of the monitor as illustrated.

Plug the AC Adapter into a 120V AC outlet (60 cycles).

Housing 2

1

Cord

TO DISCONNECT THE AC ADAPTER

Hold and pull the Housing to remove the AC Adapter from the electrical outlet. Do not remove by pulling on the cord.

Remove the AC Adapter plug from the monitor.

WARNING

Do not plug or unplug the power cord into the electrical outlet with wet hands.

CAUTION

Do not overload power outlets. Plug the device into the appropriate voltage outlet.

15

SETTING THE DATE AND TIME

Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.

The Blood Pressure Monitor automatically stores up to 60 individual measurements values with the dates and times.

The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes of the last reading.

NOTES: • If only two readings are stored in the memory for the 10minute period, the average is based on the two readings.

If one reading is stored in the memory for the 10-minute period, this reading is displayed as the average.

1.TO START THE SETTING

Press the Date/Time Setting button to adjust the date and time.

STOP

The year flashes on the display.

16

SETTING THE DATE AND TIME

2. SETTING THE YEAR

The year can be set between 2006 and 2030. When the display reaches 2030, it will return to 2006.

Press the MEMORY button to advance by increments of one year.

Press the Date/Time Setting button to set the current year.

The month flashes on the display.

NOTE: Press and hold the MEMORY

button to advance the date and time values faster.

STOP

STOP

3.SETTING THE MONTH

Press the MEMORY button to advance by increments of one month. Press the Date/Time Setting button to set the current month.

The day flashes on the display.

STOP

17

SETTING THE DATE AND TIME

4.SETTING THE DAY

Press the MEMORY button to advance by increments of one day. Press the Date/Time Setting button to set the current day.

STOP

The hour flashes on the display.

5. SETTING THE HOUR

The time is set using AM or PM.

Press the MEMORY button to advance by increments of one hour. Press the Date/Time Setting button to set the current hour.

The minute flashes on the display.

STOP

6. SETTING THE MINUTE

Press the MEMORY button to advance by increments of one minute.

Press the Date/Time Setting button to set the minute setting.

7.TO TURN THE MONITOR OFF

Press the START/STOP button.

18

APPLYING THE ARM CUFF

CAUTION

Read all of the information in the instruction manual and any other literature in the box before operating the unit.

CAUTION

This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.

APPLYING THE CUFF ON THE LEFT ARM

1. Make sure the air plug is securely inserted in the main unit.

2. Remove tight-fitting clothing from your upper left arm.

19

APPLYING THE ARM CUFF

3.Sit in a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart.

4.Hold the grip on the cuff securely with your right hand, placing your thumb on the thumb grip.

Thumb Grip

Cloth Strip

5.Turn the palm of your left hand upward.

20

APPLYING THE ARM CUFF

6.Apply the cuff to your left upper arm so the blue strip is on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow.

Blue Strip

1/2 inch (1 - 2 cm)

Air Tube

7. Wrap the cuff firmly in place around your arm using the cloth strip.

21

APPLYING THE ARM CUFF

APPLYING THE CUFF ON THE RIGHT ARM

Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuff should be approximately 1/2'' above your elbow.

Thumb Grip

NOTE: Be careful not to rest your arm on the air tube. This will restrict the flow of air to the cuff.

22

Loading...
+ 50 hidden pages