Omron BP760 User Manual

4.8 (6)
Omron BP760 User Manual

INSTRUCTION MANUAL

7 series

Blood Pressure Monitor with ComFitTM Cuff

Model BP760

ENGLISH ESPAÑOL

TABLE OF CONTENTS

Before Using the Monitor

 

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.4

Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.5

Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.5

Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.7

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.7

Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.8

Operating Instructions

 

Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.9

Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Irregular Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Movement Error Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Morning Hypertension Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Average Value Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Morning Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Evening Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Cuff Wrap Guide Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

2

TABLE OF CONTENTS

Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

.27

Cuff Wrap Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

27

Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

30

Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

31

To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . .

32

Morning and Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . .

33

Morning Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

To Display Morning and Evening Averages . . . . . . . . . . . . . . . . .

34

Display Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . .

36

Care and Maintenance

Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . .39

FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41

Limited Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43

3

Before Using the Monitor

INTRODUCTION

Thank you for purchasing the Omron® BP760 IntelliSense® Automatic Blood Pressure Monitor with ComFitTM Cuff.

Fill in for future reference.

DATE PURCHASED: __________________

SERIAL NUMBER: ____________________

Staple your purchase receipt here

Register your product on-line at www.register-omron.com

Your new digital blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.

The BP760 comes with the following components:

• Monitor

• ComFitTM Cuff • AC Adapter

Storage Case

Instruction Manual printed in English and Spanish

Quick Start Guide

The BP760 IntelliSense® Automatic Blood Pressure Monitor is intended for home use.

SAVE THESE INSTRUCTIONS

4

SAFETY INFORMATION

To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.

SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL

Indicates a potentially hazardous situation

WARNING which, if not avoided, could result in death or serious injury.

Indicates a potentially hazardous situation

which, if not avoided, may result in minor or CAUTION moderate injury to the user or patient or

damage to the equipment or other property.

OPERATING THE DEVICE

Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.

DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.

The monitor is not intended to be a diagnostic device.

If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.

Read all of the information in the instruction manual and any other literature in the box before operating the unit.

5

SAFETY INFORMATION

OPERATING THE DEVICE (continued)

This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.

Read the Special Conditions section (page 30) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.

Operate the device only as intended. Do not use the device for any other purpose.

Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.

Do not use a cellular phone near the device. It may result in an operational failure.

Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.

Use only 1.5V alkaline batteries with this device.

Do not use other types of batteries. This may damage the unit.

6

SAFETY INFORMATION

RISK OF ELECTRICAL SHOCK

Do not plug or unplug the power cord into the electrical outlet with wet hands.

Do not overload power outlets. Plug the device into the appropriate voltage outlet.

CARE AND MAINTENANCE

Do not subject the monitor to strong shocks, such as dropping the unit on the floor.

Do not submerge the device or any of the components in water.

Store the device and the components in a clean, safe location.

Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.

7

BEFORE TAKING A MEASUREMENT

To ensure a reliable reading follow these recommendations:

1.Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement.

2.Stress raises blood pressure. Avoid taking measurements during stressful times.

3.Measurements should be taken in a quiet place.

4.Remove tight-fitting clothing from your arm.

5.Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.

6.Remain still and do not talk during the measurement.

7.Wait 2-3 minutes between measurements. The wait time allows the arteries to return to the condition prior to taking the blood pressure measurement. You may need to increase the wait time depending on your individual physiological characteristics.

8.Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.

8

Operating Instructions

KNOW YOUR UNIT

Main Unit:

Display

 

SET Button

 

 

 

 

 

Morning/Evening Average

 

 

(

) Button

 

 

Memory ( ) Button

Up/Down

Start/Stop Button

(

/

) Buttons

 

Battery Compartment

Air Jack

AC Adapter Jack

9

KNOW YOUR UNIT

Components:

Housing

 

Air Tube

Cord

AC Adapter

Air Plug

(Connects to Air Jack)

Arm Cuff

INSTRUCTION MANUAL

7 series

Blood Pressure Monitor

with ComFitTM Cuff

Model BP760

ESPAÑOL

ENGLISH

Storage Case

Instruction Manual

 

 

 

 

 

 

 

 

 

 

 

 

Quick Start Guide

10

UNIT DISPLAY

 

Morning Average Symbol

Date/Time Display

Evening Average Symbol

 

 

 

 

 

 

Irregular Heartbeat Symbol

 

 

 

Average Value Symbol

Week Display

 

 

 

 

 

 

Memory Symbol

Systolic Blood Pressure

 

 

Morning Hypertension Symbol

 

 

 

 

 

Movement Symbol

Diastolic Blood Pressure

 

 

Blood Pressure Level Indicator

 

 

 

 

 

Heartbeat Symbol

 

 

Deflation Symbol

 

 

Cuff Wrap Guide

Low Battery Indicator

 

 

 

 

 

 

Pulse Display / Memory Number

11

DISPLAY SYMBOLS

IRREGULAR HEARTBEAT SYMBOL ()

When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol () will appear on the display with the measurement values.

An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.

If the irregular heartbeat symbol () displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.

Normal Heartbeat

Pulse

Blood pressure

Irregular Heartbeat

Short Long

Pulse

Blood pressure

MOVEMENT ERROR SYMBOL ()

The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during inflation.

12

DISPLAY SYMBOLS

The American Heart Association1 recommends the following guideline for upper limit of normal for home blood pressure readings:

AHA Home Guideline for Upper Limit of Normal BP

Systolic Blood Pressure

135 mmHg

 

 

Diastolic Blood Pressure

85 mmHg

This is a general guideline because blood pressure depends on age and morbidity. The AHA recommends a lower home blood pressure goal for certain patients, including diabetic patients, pregnant women, and patients with renal failure1.

The monitor is not intended to be a diagnostic device.

MORNING HYPERTENSION SYMBOL ()

The Morning Hypertension Symbol is displayed if the morning average reading for a week is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory.

Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL and/or the HEARTBEAT SYMBOL appear on the display with your measurement values.

1American Heart Association Scientific Statement 2004

13

DISPLAY SYMBOLS

HEARTBEAT SYMBOL ()

TAKING A MEASUREMENT

The Heartbeat Symbol flashes on the display during the measurement. The Heartbeat Symbol flashes at every heartbeat.

AVERAGE VALUE SYMBOL ( )

The Average Value Symbol is displayed when you press the memory button. The most recent average reading appears on the display screen.

MORNING AVERAGE SYMBOL ()

The Morning Average symbol is displayed when viewing Morning Averages using the Memory Function.

EVENING AVERAGE SYMBOL ()

The Evening Average symbol is displayed when viewing Evening Averages using the Memory Function.

CUFF WRAP GUIDE SYMBOL(/)

When the cuff is applied correctly, () is displayed while taking a measurement or using the memory function. If the cuff is not applied correctly, () is displayed.

14

Loading...
+ 30 hidden pages