Omron HEM-773AC User Manual

5 (2)

R

INSTRUCTION MANUAL

IntelliSense™

Automatic Blood Pressure Monitor

with Easy Wrap Cuff

Model HEM-773AC

TABLE OF CONTENTS

 

Introduction..................................................................................................

3

Notes on Safety............................................................................................

4

Know Your Unit ...........................................................................................

5

Quick Reference Guide................................................................................

6

Initial Set-Up

 

Battery Installation/Replacement.........................................................

7

How to Set Time and Date...................................................................

8

How to Use the AC Adapter ................................................................

9

Correct Usage

 

How to Apply the Arm Cuff ........................................................

10, 11

How to Take a Reading................................................................

12, 13

How to Use the Memory Function ....................................................

14

Troubleshooting .........................................................................................

15

Caution.......................................................................................................

16

Care and Maintenance ...............................................................................

17

Warranty.....................................................................................................

18

Specifications .............................................................................................

19

2

INTRODUCTION

Thank you for purchasing the Omron IntelliSense™ Automatic Blood Pressure Monitor with Easy Wrap Cuff, HEM-773AC. Although your blood pressure fluctuates throughout the day, no self-adjustment is necessary as the monitor intelligently adjusts to your changing conditions. The IntelliSense™ monitor uses fuzzy logic intelligence

to sense both your systolic and diastolic blood pressure values, and the result is personalized inflation with every reading. Arm discomfort and misreading due to improper cuff inflation are virtually eliminated.

Your new OMRON monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. At the press of a button, the monitor automatically fills the cuff with air, starts deflation, then displays your systolic, diastolic, and pulse readings on an extra large display panel.

Please read this instruction manual thoroughly before using this unit. For specific information on your own blood pressure, CONTACT YOUR PHYSICIAN.

NOTE:

This device is a digital monitor intended for the use in measuring blood pressure and pulse rate in adult population with the arm circumference ranging from 9 inches to 17 inches (from 23 cm to 43 cm).

3

NOTES ON SAFETY

The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening.

The icons and meanings are as follow.

Warning sign

Contents

Caution

Indicates matters in which bodily harm or material damage* may arise as a result

of incorrect handling.

 

 

*Material damage refers to a wide range of damage involving your house, household goods, domestic animals, and pets.

Caution

Self-diagnosis of measured results and treatment are dangerous. Please follow the instructions of your doctor.

Do not use the unit on infants or persons who cannot express one’s intention. Do not use the unit for any purpose other than measuring blood pressure. Do not use a cellular phone near the unit. Improper operation may result.

Do not disassemble, repair, or remodel the main unit or the arm cuff of the blood pressure monitor.

The battery liquid may leak and damage the main unit. Please observe the following points.

When you are not going to use the unit for a long period of time (approximately three months or more), take out the batteries.

Replace the worn batteries with new ones immediately.

Do not use worn and new batteries together.

Do not insert the batteries with their polarities in wrong direction.

Do not force to bend the arm cuff or the air tube excessively.

When removing the air tube, pull at the plug.

Do not apply strong shock or drop the main unit.

Do not inflate the arm cuff without it being wrapped on the arm.

4

Omron HEM-773AC User Manual

KNOW YOUR UNIT

Main Unit:

AC Adapter Jack

Release Button of Cover

Cover

Cuff Storage Container

 

Set Button

Air Jack

 

Heart Symbol

Adjust Button

Systolic Blood Pressure

User Selector

Diastolic Blood Pressure

 

 

ON/OFF Button

 

START Button

User Indicator (A or B)

Memory Call Button

Pulse Rate

Date/Time Display

Components:

Arm Cuff

(Applicable arm cuff for Adults 9 to 17 in.)

Green Mark

Air Tube

AC Adapter

Air Plug

(Connects to Air Jack)

5

QUICK REFERENCE GUIDE

1.Avoid eating, smoking, and exercising for at least 30 minutes before taking a measurement.

2.Remove tight-fitting clothing from your upper left arm.

3.Sit in a chair with your feet flat on the floor and place your left arm on a table so that the cuff is at the same level as your heart.

4.Wrap the arm cuff around your upper left arm, making sure that the bottom edge of the cuff is approximately 1/2'' to 1'' above the elbow.

5.Pull the end of the cuff so that the entire cuff is evenly tightened around your arm, and the Green Marker on the cuff is above the brachial artery.

6.Press the ON/OFF button.

7.After the Heart Symbol () appears on the digital panel, press the START button, and remain still until the measurement is complete.

8.When measurement is complete, the monitor displays your blood pressure and pulse rate, and automatically deflates the cuff.

9.Wait 2-3 minutes before taking another blood pressure measurement.

You may require more rest time between readings depending on your individual physiological characteristics.