Nuvo NV-E6DXS-DC User Manual

Size:
1.29 Mb
Download

ENGLISH

Danger

Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss but nearly everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient time. The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified the following permissible noise level exposures:

DURATION PER DAY (HOURS)

8 6

4 3 2 1

 

 

 

SOUND LEVEL (dB)

90 93

95 97 100 103

 

 

 

According to OSHA, any exposure in the above permissible limits could result in some hearing loss. Ear plugs or protectors in the ear canal or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss. If exposure in excess of the limits as put forth above, to insure against potentially harmful exposure to high sound pressure levels, it is recommended that all persons exposed to equipment capable of inducing high sound pressure levels, such as this amplification system, be protected by hearing protectors while this unit is in operation.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO

NOT REMOVE CHASSIS. NO USER-SERVICEABLE

PARTS INSIDE. REFER SERVICING TO QUALIFIED

SERVICE PERSONNEL.

AVIS: RISQUE DE CHOC ELECTRIQUE-NEPAS OUVRIR.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF NON-INSULATED"DANGEROUS VOLTAGE" WITHIN THE PRODUCT'S ENCLOSURE THAT MAY BE OF SUFFICIENT MAGNITUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK TO PERSONS.

THIS SYMBOL IS INTENDED TO ALERT THE USER TO THE PRESENCE OF IMPORTANT OPERATING AND MAINTENANCE (SERVICING) INSTRUCTIONS IN THE LITERATURE ACCOMPANYING THE UNIT.

APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS.

IMPORTANT SAFETY INSTRUCTIONS

1.Read all safety and operating instructions before using this product.

2.All safety and operating instructions should be kept for future reference.

3.Read and understand all warnings listed on the operating instructions.

4 . Follow all operating instructions to operate this product.

5.This product should not be used near water, i.e. bathtub, sink, swimming pool, wet basement, etc.

6.Only use dry cloth to clean this product.

7.Do not block any ventilation openings, It should not be placed flat against a wall or placed in a built-inenclosure that will impede the flow of cooling air.

8.Do not install this product near any heat sources ; such as, radiators, heat registers, stove or other apparatus (including heat producing amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other. A grounding-typeplug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord being walked on or pinched, particularly at plugs, convenience receptacles and the point where they exit from the apparatus. Do not break the ground pin of the power supply cord.

11 . Only use attachments specified by the manufacturer.

12.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer or sold with the apparatus. When a cart is used, use caution when moving cart/apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightning storms or when unused for long periods of time.

14.Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation ports or any other openings.

15.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way; such as, power-supplycord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.

16.WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

1

FRENCH

Danger

L‘exposition a des niveaux eleves de bruit peut provoquer une perte permanente de l’audition, Chaque organisme humain reagit differemment quant a la perte de l’audition, mais quasiment tout le monde subit une diminution de I’acuite auditive lors d’une exposition suffisamment longue au bruit intense. Les autorites competentes en reglementation de bruit ont defini les expositions tolerees aux niveaux de bruits:

DURE EN HEURES PAR JOUR

8 6

4 3 2

1

 

 

 

 

INIVEAU SONORE CONTINU EN dB

90 93

95 97 100

103

 

 

 

 

Selon les autorites, toute exposition dans les limites citees ci-dessus,peuvent provoquer certaines pertes d’audition. Des bouchons ou protections dans l’appareil auditif ou sur l’oreille doivent etre portes lors de l’utilisation de ce systeme d’amplification afin de prevenir le risque de perte permanente de l’audition, Dans le cas d’expositions superieures aux limites precitees il est recommande, afin de se premunir contre les expositions aux pressions acoustiquese I evees potentielIement dangeure u ses, aux personnes exposees aux equipements capables de delivrer de telles puissances, tels ce systeme d’amplification en fonctionnement, de proteger l’appareil auditif.

ATTENTION

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR.

ATTENTION: AFIN DE LlMlTER LE RISQUE DE CHO ELECTR/QUE, NE

PAS ENLEVER LE CHASSIS. NE CONTIENT PAS DE

PIECES POUVANT ETRE REPAREE PAR L’UTILISATEUR.

CONFER LE SERVICE APRES-VENTEAUX

REPARATEURS

CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE DE VOLTAGE DANGEREUX NON-ISOLEA L'INTERIEUR DE CE PRODUIT QUI PEUT ETRE DE PUISSANCE SUFFISAMMENT IMPORTANTE POUR PROVOQUER UN CHOC ELECTRIQUE AUX PERSONNES.

CE SYMBOLE A POUR BUT D'AVERTIR L'UTILISATEUR DE LA PRESENCE D'INSTRUCTIONS D'UTILISATION ET DE MAINTENANCE DANS LES DOCUMENTS FOURNIS AVEC CE PRODUIT.

AFIN DE REDUIRE LES RISQUÉ D'INCENDIE ET DE DECHARGE ELECTRIQUE, NE PAS EXPOSER CET APPAREIL A LA PLUIE OU A L'HUMIDITE.

IMPORTANTES INSTRUCTIONS DE SECURITE

1.Lire avec attention toutes les recommandations et précautions d'emploi avant d'utiliser ce produit.

2.Toutes les recommandations et précautions d'emploi doivent être conservées afin de pouvoir s'y reporter si nécessaire.

3.Lire et comprendre tous les avertissements énumérés dans les précautions d'emploi.

4.Suivre toutes les précautions d'emploi pour utiliser ce produit.

5.Ce produit ne doit pas être utilisé près d'eau, comme par exemple baignoires, éviers, piscine, sous-solhumides ... Etc.

6.Utiliser exclusivement un chiffon sec pour nettoyer ce produit.

7.Ne bloquér aucune ouverture de ventilation. Ne pas placer le produit tout contre un mur ou dans une enceinte fernée, cela gênerait le flux d'air nécessaire au refroidissement.

8.Ne pas placer le produit près de toute source de chaeur telle que radiateurs, arrivées d'air chaud, fourneaux ou autres appareils générant de la chaleur (incluant les amplificateurs producteurs de chaleur) .

9.Ne pas négliger la sécurité que procure un branchement polarisé ou avec raccordement à la terre, Un branchement polarisé comprend deux fiches dont l'une est plus large que l'autre. Un branchement à la terre comprend deux fiches plus une troisième reliée à la terre. Si la fiche secteur fournie ne s'insert pas dans votre prise de courant. consulter un 'électricien afin de remplacer votre prise obsolète.

10.Protéger le cordon d'alimentation de tout écrasement ou pincement, particulièrement au niveau des fiches, des réceptacles utilisés et à l'endroit de sortie de l'appareil. Ne pas casser la fiche de terre du cordon d'alimentation.

11.Utiliser uniquement les accessoires spécifiés par le constructeur.

12.Utiliser uniquement avec le chariot de transport, le support, le trépied, la console ou la table spécifiés par le constructeur ou vendus avec l'appareil. Lors de l'utilisation d'un chariot, bouger avec précaution l'ensemble chariotlappareil afin d'éviter les dommages d'un renversement.

13Débrancher cet appareil lors d'orages ou s'il n'est pas utilisé pendant une longue période.

14.Des précautions doivent être prises afin qu'aucun objet ne tombe et qu'aucun liquide ne se répande à l'intérieur de l'appareil par les orifics de ventilation ou n'importe quelle autre ouverture.

15.Pour toutes interventions techniques s'adresser à un technicien qualifié.L'intervention technique est nécessaire lorsque l'appareil a été endommagé de n'importe quelle façon, comme par exemple si le cordon secteur ou sa fiche sont détériorés,si du liquide a coulé ou si des objets sont tombés à l'intérieur de l'apparei1,si l'appareil a été exposé à la pluie ou à l'humidité, s'il ne fonctionne pas normalement ou s'il est tombé.

16.ATTENTI0N:Pour réduire le risque d'incendie ou de choc electrique ne pas exposer l'appareil à la pluie ou à l'humidité.

2

Introduction

Congratulations on your purchase of the NuVo Essentia System. Essentia brings the best of today's digital technology to a true wholehome audio system. Listening to multiple audio sources from independent zones throughout the home has never been easier or more affordable.

The elegant keypads allow independent selection of up to six different audio sources from up to twelve zones in the home.Each ship including white, almond, ivory and black inserts and trim plates to match a variety of decorating choices. Generation D digital amplification provides clear, precise digital sound to each zone without the heat generated by traditional analog amplification. The integrated infrared repeater in each keypad means you can control all of your audio sources wirelessly from any zone of your home.

Enjoying quality audio throughout the home is simple and affordable with Essentia. This installation manual is designed to provide a sequential, step-by-stepguide to making full use of the many features and capabilities of the Essentia System.

Package Contents:

E6DMS-DCMain System

1

NV-E6DM2

Six-Source,Six-ZoneAmplifier

6

NV-E6DKP-DC

Decora®* style Zone Controller Keypads

 

 

including white, almond, ivory and black.

1 NV-LRC1

Learning Remote Control

1

NV-E6DEZP

Decora® EZ Port Multi-portconnection hub

1

NV-NEC

Network connection cable

6

NV-VEC

IR emitters with feedback LED

1

NV-PC1

IEC 3-wirepower cable

E6DXS-DCExpander System

1

NV-E6DMS

Six-Source,Six-ZoneAmplifier

6

NV-E6DKP-DC

Decora® style Zone Controller Keypads

 

 

including white, almond, ivory and black

1

NV-LRC1

Learning Remote Control

1

NV-SRC1

Source Link Cable

1

NV-DNK1

Data Link Cable

1

NV-PC1

IEC 3-wirepower cable

*Decora is a registered trademark of the Leviton Corp.

Zone/Room 1

Zone/Room 2

Zone/Room 3

Zone/Room 4

Zone/Room 5

Zone/Room 6

EZ Port Cat-5connection

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

C C

C C C

AUDIO

 

 

CONTROL

 

SPEAKER

L

SENSITIVITY

POWER

VOLTAGE

UNIT

OUTPUT POWER

 

OdBV = 1.0RMS

 

 

 

MODE

TRIGGER

ON

8 OHM: 70W X 2

INPUT

LEFT

RIGHT

ON/OFF SWITCH

3-30VOLTS

+12VDC

4 OHM: 100W X 2

AUDIO AC/DC

AC OR DC

100mA

 

2

0

0

 

 

 

 

R

 

 

 

 

 

 

+6

-12

+6

-12

 

 

 

INPUT OUTPUT

 

VARIABLE

 

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

 

 

VARIABLE

 

 

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

RS-232

 

TIP=L

OUTPUT POWER

TIP=L

 

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

 

OUTPUT POWER

 

TIP=L

OUTPUT POWER

Essentia D

 

 

20W/6OHM X2

 

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

 

20W/6OHM X2

 

20W/6OHM X2

 

 

RING=R

 

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

 

 

RING=R

 

V.II

 

 

FIXED

 

 

FIXED

 

 

FIXED

 

FIXED

 

FIXED

 

 

 

FIXED

 

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

 

ZONE 3

 

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

PROGRAM

1

2

3

4

5

6

CONNECT TO

 

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

CABLE

1

2

3

4

5

6

5

2

4

6

2

4

6

SUM2

EXT. MUTE

SOURCE INPUTS

SOURCE LINK

ZONE TRIGGER OUTPUTS

EMITTER OUTPUTS

SYSTEM

NETWORK

DIGITAL LINK

USE ONLY WITH 250V FUSE

120V 60Hz 500W FUSE:T5 A

NuVo Technologies Hebron KY USA

www.nuvotechnologies.com

CONFORMS TO

UL STD.6500

CERTIFIED TO

CAN/CSA STD.E60065

Single Network cable connection to the Essentia Amplifier

Diagram shown with optional NuVo NV-P2100auxiliary amplifier powering zone 6.

Source 1

Audio

Source 3

Audio

Source 5

Audio

 

Tuner 1

Out

Tuner 3

Out

CD 2

Out

 

 

Source 2

Audio

Source 4

Audio

Source 6

Audio

 

Tuner 2

Out

CD 1

Out

Sat.

Out

Essentia D

Wiring Diagram

3

POWER

STAND BY

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

V.II

 

 

Essentia Front Panel

 

1. POWER Button: The amplifier is designed to be turned on and remain on. The power button supplies power to the system. Each zone can then be turned on or off independently. The amplifier should be turned on before any external connections are made. This activates internal protective circuitry.

2. STAND BY LED: When lit, this blue LED(light-emittingdiode) indicates that the amplifier is plugged into an AC power outlet source.

3. Zone Status LED's: These LED's indicate the power status of each zone. When a zone LED is lit, it indicates that the zone is currently turned on.

1

2

6

Keypad Features

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

3

4

5

1.

Volume Level

The level of the zone volume is indicated by these LEDs (light-emittingdiodes).

2.

Power

The power button turns that keypad's zone on and off independently of the other zones. Pressing and holding

 

 

the power button turns all zones off simultaneously.

3.

Volume

Independent audio volume level for each zone is controlled with these buttons.

4.

IR Receiver

Each keypad has an IR (infrared) receiver located under the volume button for wireless control of the audio

 

 

source equipment.

5.

Mute

The mute button temporarily silences any audio playing in that keypad's zone.

6.

Source Selection

The source buttons independently select any of the six sources connected to the Essentia amplifier.

 

 

The selected source button will remain lit.

 

 

 

 

 

 

 

 

 

 

4

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

Essentia D

RS-232

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

V.II

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

 

PROGRAM

1

2

3

4

5

6

CONNECT TO

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

CABLE

1

2

3

4

5

6

 

5

2

4

6

2

4

6

SUM2

EXT. MUTE

 

 

 

SOURCE INPUTS

 

 

SOURCE LINK

 

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM NETWORK

DIGITAL LINK

 

 

 

MODEL NV-6DM2

SIX SOURCE SIX ZONE

AUDIO DISTRIBUTION SYSTEM

120V60Hz 500W FUSE:T5 A

NuVo Technologies Hebron KY USA

www.nuvotechnologies.com

 

 

CONFORMS TO

 

US

UL STD.6500

C

CERTIFIED TO

 

3033118

CAN/CSA STD.E60065

 

 

Essentia Back Panel

1. Audio Source Inputs: The Essentia amplifier accepts up to six audio sources. A source consists of any audio component capable of supplying a line level signal.

2. Source Link: Thismulti-pinconnection is used to transfer the audio information from the Essentia main amplifier to the expander amplifier. This output is used to expand the system to twelve zones. The source link connection cable is provided with the Essentia D Expander package.

3. Variable Lineout: The variable lineout is intended for zones where additional amplification is needed and the Essentia keypad is used to control the volume of all the speakers in that zone.

4. Fixed Lineout: The fixed lineout is intended for zones where additional amplification and separate volume control are needed.

5.Speaker Outputs: Individual stereo speaker outputs for each zone provide 20 watts output per channel.

6.Zone Triggers: These outputs provide a12-voltoutput when the corresponding zone is turned on. This is used to trigger

external equipment specific to a given zone.

7. Emitter Outputs: These outputs transfer IR (infrared) signals, repeated from a zone keypad, from the Essentia amplifier to the audio source equipment. There are six source specific outputs and two “sum” output that sends IR signals regardless of the selected source.

8. System On: This output provides a constant12-voltoutput when any zone is turned on. This is used to trigger external devices.

9.External Mute: This is designed to mute any audio playing through the system when the phone or doorbell rings.

10.Network Input: ThisRJ-45connection is the input for all zone information coming from the Essentia keypads. The

connection is made using the Network Cable supplied with the package.

11. Digital Link: Thismulti-pinconnection transfers all the digital information from the main amplifier to the expander amplifier. This output is used to expand the system from six to twelve zones. The Digital Link connection cable is provided with the Essentia D Expander package.

12.RS232 Port: The RS232 serial port allowstwo-waycommunication for control by a home automation system.

13.AC Power: A detachable power cable supplies power to the Essentia System from any AC outlet.

5

LRC1 Learning Remote Control

7

1

1

 

2

3

S

OUR

 

 

 

 

CE

 

4

5

6

 

 

 

 

 

 

WHOLE

-HOMECO

 

 

NTROL

 

 

VOL-

VOL+

 

MUTE

 

 

 

ON/OFF

2

3

4

8 5

M1

M2

M3

M4

9

M5

M6

M7

M8

NV-LRC1

1. Setup:

The setup button is used to place the

 

remote control in program/learn mode.

2. Whole-HomeControl:

This section automatically performs the

 

basic Essentia keypad functions.

3. Transport Buttons:

The transport buttons perform basic

 

source specific functions, such as play,

 

stop, pause, forward and reverse.

4. Video Source Control:

These buttons are typically used by

 

video equipment for menu navigation

 

and selection.

5. Source Volume:

This is source specific volume control,

 

such as a TV or stereo receiver. This is not

 

used for NuVo zone volume.

6. Numeric Buttons:

These buttons provide source specific

 

direct numeric access.

7. Power Button:

This power button is for source specific

 

power on and off. It is not for NuVo zone

 

on and off.

8. Channel up and down:

This button provides source specific

 

channel scrolling.

9. Macro Buttons:

These buttons do not perform a given

 

source function. They can be used for

 

programming multiple function macro

 

commands.

6

Installing the Essentia System in Your Home

I. Prewire

The Essentia System uses CAT5 cable for keypad control and either two or four-conductor16-gaugespeaker wire. All the wire is “homerun” from each zone to the location of the Essentia amplifier and Audio Source equipment.

Complete CAT5 Crimping Instructions

The NuVo audio systems require CAT5, unshielded, twisted pair (UTP), for communication between the keypads/Display Pads and the main amplifier unit. Each end of the wire is terminated with an RJ45 connector.

The Essentia System can accommodate 2,000 total feet of CAT5 cable. For the most reliable operation, it is best that no single run of CAT5 exceeds 250 feet.

The correct wiring scheme for the CAT5 cable is standard EIA/TIA 568A. Properly terminating the CAT5 cable is crucial for the operation of the system. It is very important to use a good quality crimp tool, and test each end to end run with a CAT5 wire tester to insure that your system operates flawlessly, fig.1.

Step-by-StepCrimping Instructions:

1.Strip a 2 to 3 inch portion of the insulation, exposing the 4 twisted pairs.

2.Untwist the wires and fan them out individually. Arrange the wires into the correct color scheme as shown in Fig. 1.

3.Flatten the wires in their correct order, and trim them evenly across the top. Most crimp tools have a wire trimmer built-in.It is best to trim the wires to about ½” in length.

4.While holding the wires flat between your thumb and forefinger, insert the wires into the RJ45 connector, so each is in its own slot. Push the wire into the RJ45, so all 8 conductors touch the end of the connector. The insulation jacket should extend beyond the crimp point of the RJ45.

5.Insert the RJ45 into the crimp tool receptacle and squeeze the tool firmly. Note that a ratchet type tool should tighten down until it no longer clicks.

6.The RJ45 should be firmly crimped to the CAT5 insulation. It is necessary that the color scheme be repeated identically on each end of the wire.

Top view with tab down.

 

 

Bus

 

-

 

Bus+

 

 

Data

 

Data

 

 

 

 

 

Power

Ground IR TX

Ground Control Control

 

 

Active Ground +12V

IR

 

 

1 2 3 4 5 6 7 8

 

Pair 2

Pair 1

Pair 4

Pair 3

Wires insert from this end.

Fig. 1: EIA 568A wiring scheme for CAT5 Cable Pin #

1.Green Stripe

2.Green

3.Orange Stripe

4.Blue

5.Blue Stripe

6.Orange

7.Brown Stripe

8.Brown

Note: Colors listed as “stripe” are a white wire with a colored stripe.

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

7

II. Installing the Essentia Amplifier

System setup works best when the amplifier is placed in the same location as the audio source equipment. This is typically in an audio rack, entertainment center or a closet dedicated to housing the home audio/video equipment.

The amplifier should be plugged in and the power button on the front panel should be depressed before proceeding with the rest of the installation. This activates the internal protective circuitry of the Essentia System.

II. Terminating Speaker Wire

The speaker wire for each zone is terminated in a standard Eurostyle connector that plugs into each zone specific amplified output. The common speaker termination scheme is Left - Left +, Right - Right +. Either two or four-conductor16-guagewire is recommended. Larger than14-guagewire will not fit into the euro connector.

To terminate the speaker wire, strip back the outer jacket and expose the inner conductors. Strip approximately 1/4” (4 mm) of the insulation from the inner conductors exposing the copper wire. Place the exposed wire in the euro connector and tighten the screw down terminals, fig. 2.

Be careful not to allow the exposed wire from each conductor to touch the adjacent conductor. This will short the speaker input. Each speaker output is designed for two 8-Ohmspeakers.

Overloading the amplifier could cause it to overheat and do damage to the output.

III. Installing the NV-E6DEZPEZ Port

The EZ Port is a multi-connectionhub designed to accept all the CAT5 wires from the keypads in the system. The location of the EZ Port should be determined by the location of the Essentia amplifier. It is best to place in the wall behind the amplifier that would be easily accessible if necessary.

The EZ Port fits easily in any dual-gangsize construction bracket with an open back. These are often referred to as “mud rings”. Simply plug the terminated CAT5 wires into any of the sixteen available jacks on the back of the EZ Port, Fig. 3. The order in which the individual CAT5 wires are plugged is in not important, although it is strongly recommended that you label the CAT5 with the appropriate zone number for future reference.

Once you have plugged the Cat-5wires into the EZ Port, screw the EZ Port into its construction bracket using the supplied mounting screws.

Fig. 2

LEFT LEFT RIGHT RIGHT

- +- +

Fig. 3

8

IV. Connecting the EZ Port to the Essentia amplifier

When the EZ Port is installed in the wall the only part visible should be the faceplate and a single RJ45 jack. The supplied preterminated network cable can then be plugged into the jack on the EZ Port and into the network connection on the back of the Essentia amplifier, Fig. 4. Any CAT5 cable terminated using 568A or 568B network wiring will suffice should you need a longer connection.

V. Attaching Audio Source Equipment to the Essentia Amplifier

Each piece of audio source equipment is connected to the Essentia amplifier with standard stereo RCA cables. Attach the RCA cable to the corresponding audio output on the source equipment and to the desired source input on the back of the Essentia amplifier, Fig. 5.

VI. Connecting the IR Emitters

IR commands for the source equipment are transferred from the Essentia amplifier to the source equipment via mini IR mouse emitters. Six of these are supplied with your Essentia System. The emitter is plugged into the corresponding source IR output on the Essentia and then placed over the IR receiver window on the source component, fig. 6. The IR outputs are individually routed to sources 1-6allowing IR commands from the chosen source to only control that source.

The two SUM outputs will flash any IR command that is sent from any of the zones. This is used to connect the NuVo T2 Tuner, which has a single IR direct input to control both tuners to the Essentia System or an IR blaster designed to flash IR commands to a variety of components. This is done by plugging a single mono 1/8” patch cable into the SUM IR output and into the Direct IR input.

Fig. 4

EZ Port (front)

 

 

 

Essentia Network

 

 

 

 

Connection

 

 

 

PROGRAM

 

 

SYS ON

 

 

 

CONNECT TO

CONNECT TO

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

NV-E6DEZ Port

USE NV-NC1

USE NV-SLC1

 

Model NV-E6DEZP

CABLE

 

 

CABLE

 

 

EXT. MUTE

 

 

Connect to NV-E6DM

NETWORK

DIGITAL LINK

 

 

 

Audio Distribution Amplifier

Network Cable

Fig. 5

 

VARIABLE

 

 

VARIABLE

 

VARIABLE

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT POWER

 

 

OUTPUT POWER

 

OUTPUT POWER

 

TIP=L

 

20W/6OHM X2

TIP=L

 

20W/6OHM X2

TIP=L

20W/6OHM X2

 

RING=R

 

 

RING=R

 

RING=R

 

 

FIXED

 

 

FIXED

 

 

FIXED

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

 

ZONE 1

 

 

ZONE 2

 

 

ZONE 3

 

1

2

3

4

5

6

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

CABLE

 

1

2

3

4

5

6

 

 

 

 

 

SOURCE INPUTS

 

 

SOURCE LINK

 

Source 1

Audio

Tuner 1

Out

Fig. 6

9

VII. Expanding Essentia to 12 Zones

Six additional listening zones can be added to the Essentia System using the Essentia Expander package. The expansion is easily done using the Source Link and Digital Link multi-pinoutputs on the Essentia main amplifier, Fig. 7.

The necessary cables for this are supplied with the Expander package. No other connections are necessary with the exception of the AC power cord and the additional speaker terminations. The additional CAT5 wires for the zones 7-12plug into the EZ Port.

Fig. 7

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

 

VARIABLE

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

 

OUTPUT

OUTPUT POWER

OUTPUT POWER

OUTPUT POWER

OUTPUT POWER

 

OUTPUT POWER

OUTPUT POWER

TIP=L

TIP=L

TIP=L

TIP=L

TIP=L

 

TIP=L

RING=R

RING=R

RING=R

RING=R

RING=R

 

RING=R

FIXED

FIXED

FIXED

FIXED

FIXED

 

FIXED

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

 

OUTPUT

ZONE 71

ZONE 8

ZONE 9

ZONE 10

ZONE 11

 

ZONE 12

 

CONNECT TO

7

8

9

 

 

1

 

 

CONNECT TO

 

NV-E6DM2

 

 

 

NV-E6DM2

 

 

USE NV-SLC1

 

 

 

 

 

 

USE NV-SLC1

 

 

 

CABLE

 

 

 

 

 

 

CABLE

 

 

 

 

5

10

11

12

 

 

 

 

 

SOURCE LINK

 

ZONE TRIGGER OUTPUTS

 

 

DIGITAL LINK

VARIABLE

VARIABLE

 

VARIABLE

VARIABLE

 

 

VARIABLE

VARIABLE

 

 

OUTPUT

OUTPUT

 

OUTPUT

OUTPUT

 

 

OUTPUT

OUTPUT

Essentia D

RS-232

TIP=L OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L OUTPUT POWER

TIP=L OUTPUT POWER

 

TIP=L OUTPUT POWER

TIP=L OUTPUT POWER

RING=R

RING=R

 

RING=R

RING=R

 

 

RING=R

RING=R

V.II

 

FIXED

FIXED

 

FIXED

FIXED

 

 

FIXED

FIXED

 

OUTPUT

OUTPUT

 

OUTPUT

OUTPUT

 

 

OUTPUT

OUTPUT

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

 

PROGRAM

1

2

3

4

5

6

CONNECT TO

 

1

2

3

1

2

3

SUM1

SYS ON

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

USE NV-SLC1

USE NV-NC1

USE NV-SLC1

CABLE

CABLE

 

CABLE

1

2

3

4

5

6

5

4

5

6

4

5

6

SUM2

EXT. MUTE

 

 

 

 

SOURCE INPUTS

 

SOURCE LINK

 

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM

NETWORK

DIGITAL LINK

Data Link Cable

Source Link Cable

VIII. Installing the Essentia Keypads

You are now ready to install the keypads and complete the

Fig. 8

Essentia installation. This is easily done using a rotary switch

 

located on the back of the keypad to set a specific zone address

 

for each keypad, Fig. 8.

 

The switch requires the use of a small flat screwdriver and is set

 

by turning the arrow insert on the switch to the appropriate zone

 

number. Zones 1-12are set by using switch positions1-C(note

 

that zones 10, 11 and 12 are denoted by A, B and C respectively).

 

Switch positions D, E, F and 0 are for additional keypads in zones

 

1-4.

 

It is important to note that the keypads will not function properly unless each has its own unique zone address.

Once each keypad’s zone address is set, the CAT5 can be plugged in and the keypad installed in the wall.

 

0

 

 

 

F 1

 

D

E

2

3

 

4

C

 

5

B

7

6

 

 

 

 

A98

 

Zone

 

Local Source

Address

 

 

 

Essentia Keypad

 

 

Model NV-E6DKP-DC

WARNING:

 

Use only with

 

NuVo Essentia System

AVIS:

Utiliser uniquement avec

NuVo Essentia System

 

NuVo Technologies LLC Hebron, Kentucky USA

www.nuvotechnologies.com

Network

Connection

10

IX. Keypad Zone Settings

Fig. 9

Each Essentia keypad has the ability to set specific zone functions. These are bass and treble EQ, source grouping, all on (party mode) and volume reset. Each of these functions is accessed by pressing the MUTE and SOURCE 1-5buttons simultaneously, fig. 9.

While the keypad is in the function set mode, the appropriate source button with flash. To return to normal zone control, press the flashing source button.

Source 1

Source 3

Source 5

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

! " #

$%&

'

Source 2

Source 4

EQ Control and Source Grouping

To change bass response, press the Mute button and Source 1 button simultaneously. Adjust the bass level up or down by using the Volume Up and Volume Down buttons. The volume indicator LEDs will indicate the output level, fig. 8. Adjust treble response using the same process. This is accessed by pressing the Mute and Source 2 buttons. Once the desired setting is made, press the Source button again to return the keypad to normal operation.

Source grouping is a feature that allows multiple zones in an open living space to always share the same source selection but still retain individual volume and on/off control. This is achieved by pressing Mute and Source 3. Volume Up enables the group function, and Volume Down disables the group function and causes the keypad to operate independently of all other groups, fig. 10.

Fig.10

-4dB

FLAT

+4 dB

 

 

-6dB

 

+6 dB

 

 

-8dB

 

+8 dB

VOLUME

Fig. 11

Group Disabled

Group Enabled

 

VOLUME

11

All On/Party Mode

% ( # )"" * ) ( + (,-

( #.-,-"! . " (

# # " # + (,

-"" " . ! " # " ! ". " ""

," + (, . #,"( ,

# " "( -""! " #$%& / + (, "

"( 0 , ! " # " ! " 1 23 )""

-"" # " ! ! " # " ! "

-! " # 0 #

# + (, . ' % + (, ! " #$%& , # " ! " " . '

) ( + (, ! " ( ! # ( " '-. ' ' " "

/ ! " # ". ( ' " " / + (,

+

# # ( , ' 4

, '

Volume Reset

Each zone has the capability of turning on at two different volume level settings. At factory default the zone will turn on at the previous listening level. If desired, you can change that default to a low level volume reset regardless of the previous level.

To change the zone to volume reset mode, press the Mute and Source 5 buttons simultaneously. The Source 5 button will begin flashing. The volume LED will first appear at the far left indicating no volume reset. Pushing the Volume Up button will cause the volume LED to move to the far right position. This now indicates that the zone is in volume reset mode, fig. 14.

To return to normal keypad operation, press the Source 5 button again and it will stop flashing. In the volume reset mode the zone will automatically turn on at a preset -60dB level. The volume reset can be turned off by repeating the above steps and returning the volume LED to the far left position.

Fig. 12

The lit volume LED will flash when the keypad is in Master Mode.

VOLUME

Press the Mute

 

MUTE

and Source 4

 

 

TNR1

CD

buttons to

 

TNR2

HD

initiate the

Master Mode.

 

 

SAT 1

SAT2

 

Source 4

Fig. 13

 

-28to-19dB

 

-38to-29dB

 

-18to-13dB

 

 

 

-54to-39dB

-12to-7dB

 

 

 

-78to-55dB

-6to 0 dB

 

 

VOLUME

Fig. 14

Volume Reset Off

Volume Reset On

VOLUME

12

X. Using the Fixed and Variable Lineouts

Each zone of the Essentia amplifier has two 3.5mm mini stereo outputs. These are fixed and variable lineouts used for adding additional amplification when necessary for each zone. A distinct advantage to the NuVo equipment is the ability to use the amplified output, variable and fixed lineouts all simultaneously on all zones. The Essentia amplifier has zone trigger outputs that provide a 12V trigger for additional amplification. This enables the attached amplifier to be triggered on and off with the zone keypad.

Zone Variable Lineout

The variable lineout is designed to allow additional audio amplification volume level to be controlled from that zone’s keypad. When used in conjunction with the zone amplified output, fig. 15, all the speaker’s volume will track with the keypad volume level.

Fig. 15

Zone/Room 1

VOLUME

The Zone keypad controls the audio volume.

Diagram shown using the NuVo P2100 amplifier

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

MODEL NV-P2100

HIGH EFFICIENCY 200 WATT

STEREO AMPLIFIER

120V 60HZ 250 WATTS

NuVo Technologies Cincinnati Ohio. USA

AUDIO

 

 

CONTROL

 

SPEAKER

 

 

 

 

 

 

USE ONLY WITH 250V FUSE

L

SENSITIVITY

POWER

VOLTAGE

UNIT

OUTPUT POWER

 

OdBV = 1.0RMS

 

 

 

MODE

TRIGGER

ON

8 OHM: 70W X 2

INPUT

LEFT

RIGHT

ON/OFF SWITCH

3-30VOLTS

+12VDC

4 OHM: 100W X 2

AUDIO AC/DC

AC OR DC

100mA

 

2

0

0

 

 

 

 

R

 

 

 

 

 

 

+6

-12

+6

-12

 

 

 

INPUT OUTPUT

 

 

 

SIX SOURCE SIX ZONE

 

 

 

 

 

MODEL NV-6DM

 

 

 

 

 

AUDIO DISTRIBUTION SYSTEM

 

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

Essentia D

RS-232

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

V.II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXED

FIXED

FIXED

FIXED

FIXED

FIXED

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

 

PROGRAM

1

2

3

4

5

6

CONNECT TO

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

NV-E6DX

1

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

CABLE

1

2

3

4

5

6

5

2

4

6

2

4

6

SUM2

EXT. MUTE

 

 

 

 

 

 

SOURCE INPUTS

 

 

SOURCE LINK

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM NETWORK

DIGITAL LINK

USE ONLY WITH 250V FUSE

MODEL NV-6DM2

SIX SOURCE SIX ZONE

AUDIO DISTRIBUTION SYSTEM

120V60Hz 500W FUSE:T5 A

NuVo Technologies Hebron KY USA

www.nuvotechnologies.com

CONFORMS TO

UL STD.6500

CERTIFIED TO

CAN/CSA STD.E60065

3033118

Source 1

Audio

Tuner 1

Out

13

Zone Fixed Lineout

In some zone applications, it is more advantageous to have a separate volume control on the additional speakers being driven by an additional amplifier. This is common with outdoor zones. The fixed lineout offers the capability to add amplification, but the audio signal is not affected by the zone keypad volume level. Therefore, it requires a separate volume control for those speakers, fig. 16.

Fig. 16

Zone/Room 1

VOLUME

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

C C C

Additional speakers are controlled by a separate volume control.

Diagram shown using the NuVo P2100 amplifier

AUDIO

L

SENSITIVITY

 

OdBV = 1.0RMS

INPUT

LEFT

RIGHT

2

0

0

R

 

 

+6

-12+6

-12

INPUT OUTPUT

CONTROL

POWER

VOLTAGE

UNIT

MODE

TRIGGER

ON

ON/OFF SWITCH

3-30VOLTS

+12VDC

AUDIO AC/DC

AC OR DC

100mA

SPEAKER

OUTPUT POWER

8 OHM: 70W X 2

4 OHM: 100W X 2

MODEL NV-P2100

HIGH EFFICIENCY 200 WATT

STEREO AMPLIFIER

120V 60HZ 250 WATTS

NuVo Technologies Cincinnati Ohio. USA

USE ONLY WITH 250V FUSE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

VARIABLE

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

Essentia D

RS-232

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

V.II

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIXED

FIXED

FIXED

FIXED

FIXED

FIXED

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

OUTPUT

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

 

PROGRAM

1

2

3

4

5

6

CONNECT TO

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

NV-6DX

1

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

CABLE

1

2

3

4

5

6

5

2

4

6

2

4

6

SUM2

EXT. MUTE

 

 

 

 

 

 

SOURCE INPUTS

 

 

SOURCE LINK

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM NETWORK

DIGITAL LINK

USE ONLY WITH 250V FUSE

MODEL NV-6DM2

SIX SOURCE SIX ZONE

AUDIO DISTRIBUTION SYSTEM

120V60Hz 500W FUSE:T5 A

NuVo Technologies Hebron KY USA

www.nuvotechnologies.com

CONFORMS TO

UL STD.6500

CERTIFIED TO

CAN/CSA STD.E60065

3033118

Source 1

Audio

Tuner 1

Out

14

XI. The NV-LRC1IR Remote Control

The Essentia System comes with the NV-LRC1Learning Remote Control. This remote allows wireless control of all keypad functions, as well as the functions of the audio source equipment. Each NuVo zone keypad has an IR receiver that captures the specific source commands from any remote control and in turn sends the command ultimately to the appropriate source equipment. Embedded IR code libraries makes use of the LRC1 with a large variety of audio and video equipment easy. For complete setup and functionality refer to the User Guide included with the remote control. Additional remote controls are available from NuVo.

XII. NV-MI1Mute Interface Adapter

The Mute Interface is used in conjunction with System Mute input in the back of the Essentia amplifier. It acts as a relay for a voltage from up to two phone lines and two doorbell transformers. When a voltage is presented to the MI1 it then sends a contact closure to the Essentia System, which in turn causes the system to mute momentarily. This is useful in allowing the telephone ring or doorbell to be heard when audio is playing in any of the zones, Fig. 17.

Fig. 17

 

VARIABLE

 

 

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

 

 

VARIABLE

 

 

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

OUTPUT POWER

OUTPUT

 

 

 

OUTPUT

 

 

 

 

 

OUTPUT POWER

 

 

OUTPUT POWER

OUTPUT POWER

 

 

 

OUTPUT POWER

 

 

OUTPUT POWER

Essentia D

RS-232

 

RING=R

 

20W/6OHM X2

 

RING=R

20W/6OHM X2

RING=R

20W/6OHM X2

RING=R

20W/6OHM X2

RING=R

 

 

 

RING=R

20W/6OHM X2

 

 

TIP=L

 

 

 

TIP=L

 

TIP=L

TIP=L

TIP=L

 

20W/6OHM X2

 

TIP=L

 

 

 

 

FIXED

 

 

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

 

 

FIXED

 

V.II

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

 

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

PROGRAM

1

2

3

4

5

6

 

 

 

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

 

CONNECT TO

 

 

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

L

 

L

 

L

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

CABLE

CABLE

 

R

 

R

 

R

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

2

4

6

2

4

6

SUM2

EXT. MUTE

 

 

 

 

 

 

 

 

 

 

 

 

SOURCE INPUTS

 

SOURCE LINK

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM NETWORK

DIGITAL LINK

USE CNLY WITH 250V FUSE

MODEL NV-6DM

SIX SOURCE SIX ZONE

AUDIO DISTRIBUTION SYSTEM

120V 60Hz 500W

FUSE:T5 A

NuVo Technologies Cincinnati Ohio USA

www.nuvotechnologies.com

 

CONFORMS TO

 

UL STD.6500

C

US CERTIFIED TO

3033118

CAN/CSA STD.E60065

The MI1 connects to the NuVo amplifier using a standard mono patch cable with amini-plugon each end. Plug one

end into the EXT. MUTE input on the back of the amplifier and the other end into the input on the front of the Mi1.

The back of the MI1 will accept up to two AC or DC voltages from two different doorbell chimes. This connection is done with a two conductor wire from the terminals on the doorbell chime to the Doorbell A or Doorbell B inputs on the back of the MI1. Polarity is not important for this connection.

MUTE INTERFACE

ADAPTER

NV-MI1

CONNECT TO MUTE INPUT

A

DOORBELL 1

B

A

DOORBELL 2

B

Connect to Telephone RJ-11

Line 1: Pins 3,4 Line 2: Pins 2,5

Model NV-MI1

Mute Interface Module

Up to two phone lines can be brought into the RJ-11connection on the back of the MI1. The voltage from the phone ringer will trigger the NuVo System to mute.

15

XIII. NV-LSA40Local Source Amplifier

The LSA40 is 40 watt accessary amplifier that allows any line-levelaudio signal local to a zone to be amplified through that zone’s speakers. It is designed to be used universally in a variety of applications, but as shown in fig. 18, it can be triggered on and off by any zone keypad. When connected to the keypad, the user will listen to the NuVo audio system when the zone is turned on. When the zone is off the LSA40 will automatically amplify any incoming local audio signal.

Fig. 18

 

VARIABLE

 

 

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

 

 

VARIABLE

 

 

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

RS-232

 

TIP=L

OUTPUT POWER

 

TIP=L

OUTPUT POWER

OUTPUT POWER

 

OUTPUT POWER

 

 

OUTPUT POWER

 

 

OUTPUT POWER

Essentia D

 

 

20W/6OHM X2

 

20W/6OHM X2

TIP=L

20W/6OHM X2

TIP=L

20W/6OHM X2

TIP=L

 

20W/6OHM X2

 

TIP=L

20W/6OHM X2

 

 

RING=R

 

 

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

 

 

RING=R

 

V.II

 

 

FIXED

 

 

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

 

 

FIXED

 

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

 

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

PROGRAM

1

2

3

4

5

6

 

CONNECT TO

 

 

1

3

5

1

3

5

SUM1

SYS ON

CONNECT TO

 

 

 

 

 

 

 

NV-E6DX

 

 

1

 

 

 

 

 

 

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

 

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

CABLE

1

2

3

4

5

6

5

2

4

6

2

4

6

SUM2

EXT. MUTE

SOURCE INPUTS

SOURCE LINK

ZONE TRIGGER OUTPUTS

EMITTER OUTPUTS

SYSTEM

NETWORK

DIGITAL LINK

NuVo System zone speakers.

USE ONLY WITH 250V FUSE

120V 60Hz 500W FUSE:T5 A

NuVo Technologies Hebron KY USA

www.nuvotechnologies.com

 

 

CONFORMS TO

 

US

UL STD.6500

C

CERTIFIED TO

3033118

 

CAN/CSA STD.E60065

Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier.

LSA40P Back

A two conductor wire is used as a voltage trigger from the LSA40 the NuVo zone keypad. When the zone is turned on this allows to NuVo system audio to pass to the zone speakers. When the zone is turned off the internal amplifier of the LSA40 is automatically engaged.

The connection from the LSA40 to the Essentia or Concerto keypads is done using the provide two

prong plug.

LSA40P Front

+

+

0

 

 

-

-

F 1

 

D

E

2

 

3

 

 

4

50 Watt AC

C

5

B

76

power adapter

 

A98

 

 

 

supplied with

 

 

 

the LSA40P

 

 

 

Zone/Room 1

VOLUME

16

XIV. NV-LSA40PDLocal Source Amplifier Power Distribution Hub

The LSA40PD is a great device for distributing the necessary DC power to up to 4 individual LSA40 amplifiers. This allows the LSA40 components to be remotely located without the need for an external power supply in the zone, fig. 19. The LSA40PD is typically located where the Essentia amplifier is installed. The power from the head end to each of LSA40 locations is sent over standard 16 gauge speaker wire.

Fig. 19

 

VARIABLE

 

 

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

 

 

VARIABLE

 

 

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

 

 

TIP=L

OUTPUT POWER

 

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

 

OUTPUT POWER

 

TIP=L

OUTPUT POWER

Essentia D

RS-232

 

RING=R

 

 

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

 

 

RING=R

 

 

 

FIXED

 

 

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

 

 

FIXED

 

V.II

 

 

OUTPUT

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

 

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

PROGRAM

1

2

3

4

5

6

 

 

 

 

1

3

5

1

3

5

SUM1

SYS ON

 

 

 

 

 

 

 

CONNECT TO

 

 

 

 

 

 

 

 

 

CONNECT TO

CONNECT TO

 

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

L

L

L

USE NV-SLC1

USE NV-NC1

USE NV-SLC1

 

 

 

CABLE

CABLE

CABLE

R

R

R

 

 

 

 

 

 

 

 

 

2

4

6

2

4

6

SUM2

EXT. MUTE

 

 

CONFORMS TO

1

2

3

4

5

6

 

 

UL STD.6500

 

 

 

 

 

 

 

 

 

 

CERTIFIED TO

 

 

SOURCE INPUTS

 

SOURCE LINK

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM

NETWORK

DIGITAL LINK

CAN/CSA STD.E60065

Any NuVo System zone output can be wired to the LSA40 Local Source Amplifier.

16 gauge 2 conductor speaker wire is required to send voltage from the LSA40PD to four separate zones.

LSA40PD

 

 

Back

LSA40PD Front

AC Power Source

MODEL:NV-LSA40PD-DCLOCAL SOURCE AMPLIFIER 28VDC 5A

++

ZONE 1 ZONE 3

--

+

+

ZONE 2

ZONE 4

--

POWER

200 Watt AC

DESIGNED IN USA

 

MADE IN CHINA

 

 

power adapter

 

included with

 

the LSA40PD

LSA40 Back

MODEL:NV-LSA40

LOCAL SOURCE AMPLIFIER

+

.1

2

 

D

+

V8

 

-

5A

CD

TO

APY EK

-

 

 

L+

TO

 

 

SPEAKER

L+

 

 

 

 

R+

AMPLIFIER

 

 

R+

R-

 

 

 

R-

L-

 

 

 

 

L-

 

 

 

 

TO

 

NuVo Technologies LLC Cincinnati, Ohio USA

www.nuvotechnologies.com

Designed In USA Made In China

WIRE STRIP 5/16” (8MM)

LSA40 Back

MODEL:NV-LSA40

LOCAL SOURCE AMPLIFIER

+.1 V82 DA +

5A CD TO PY

-EK -

L+

TO

SPEAKER

L+

 

 

R+

AMPLIFIER

R+

R-

 

R-

L-

 

 

L-

 

 

TO

 

NuVo Technologies LLC Cincinnati, Ohio USA

www.nuvotechnologies.com

Designed In USA Made In China

WIRE STRIP 5/16” (8MM)

LSA40 Back

MODEL:NV-LSA40

LOCAL SOURCE AMPLIFIER

+

.1

V8

 

D

+

-

 

2

TO

-

5A

CD

APY KE

L+

TO

 

 

SPEAKER

L+

 

 

 

 

R+

AMPLIFIER

 

 

R+

R-

 

 

 

R-

L-

 

 

 

 

L-

 

 

 

 

TO

 

NuVo Technologies LLC Cincinnati, Ohio USA

www.nuvotechnologies.com

Designed In USA Made In China

WIRE STRIP 5/16” (8MM)

LSA40 Back

MODEL:NV-LSA40

LOCAL SOURCE AMPLIFIER

+

.1

V82

TO

D

+

-

5A

CD

APYEK

-

L+

TO

 

 

SPEAKER

L+

 

 

 

 

R+

AMPLIFIER

 

 

R+

R-

 

 

 

R-

L-

 

 

 

 

L-

 

 

 

 

TO

 

NuVo Technologies LLC Cincinnati, Ohio USA

www.nuvotechnologies.com

Designed In USA Made In China

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

WIRE STRIP 5/16” (8MM)

17

XV. NV-LSI12Local Source Interrupt

A lower cost alternative to the LSA40 is the LSI12. This is a non-amplifiedlocal source interrupt. It is installed in the same way the LSA40 is installed, but the incoming local signal must be amplified, fig 20. This is a useful accessory where a local amplified signal is already present.

Fig. 20

The selected zone speaker output of the Essentia or Simplese amplifier is wired directly to the LSI12.

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

VARIABLE

 

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

RS-232

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

TIP=L

OUTPUT POWER

Essentia D

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

20W/6OHM X2

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

RING=R

 

V.II

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

FIXED

 

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

OUTPUT

 

 

 

 

ZONE 1

 

 

ZONE 2

 

ZONE 3

ZONE 4

 

ZONE 5

 

 

ZONE 6

 

 

 

 

PROGRAM

 

USE ONLY WITH 250V FUSE

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

CONNECT TO

1

1

3

5

1

3

5

SUM1

SYS ON

CONNECT TO

CONNECT TO

 

 

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

 

 

NV-E6DEZP

NV-E6DX

120V

60Hz 500W FUSE:T5 A

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

 

USE NV-NC1

USE NV-SLC1

NuVo Technologies Hebron KY USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

www.nuvotechnologies.com

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

5

 

 

 

2

4

6

SUM2

 

 

 

 

CONFORMS TO

1

2

3

4

5

6

 

2

4

6

EXT. MUTE

 

 

 

UL STD.6500

 

 

 

 

 

 

 

 

 

 

 

 

 

CERTIFIED TO

 

 

SOURCE INPUTS

 

 

SOURCE LINK

 

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

SYSTEM

NETWORK

DIGITAL LINK

 

CAN/CSA STD.E60065

LSI12 front

LOCAL SOURCE

SWITCH

NV-LSI12

CONNECT TO

AMPLIFIER

LSI12 back

Model NV-LSI12

Mute Interface Module

RLY+

To Keypad

 

RLY-

Speakers

R-

R-

Am

L-

plifier

 

L-

L+

 

L+

R+

To

To

R+

The connection from the LSI12 is done with the provided two prong plug. Make sure that red is positive and black is negative when splicing the two conductor wire from the LSI12.

 

0

 

 

 

F

1

 

D

E

 

2

 

3

 

 

4

C

 

 

5

B

 

7

6

 

 

 

 

 

A98

 

VOLUME

MUTE

TNR1 CD

TNR2 HD

SAT 1

SAT2

A two conductor wire from a relay on the LSI12 plugs into the back of the zone keypad.

When the Essentia or Simplese keypad is turned off the local source is routed to the zone speakers.

The Essentia or Simplese is active when the zone keypad is turned on.

Four conductor speaker wire from the LSI12 to the zone speakers.

Speaker input from Essentia or Simplese.

18

XVI. NV-P2100200 Watt Auxiliary Amplifier

The P2100 is specifically designed for use with the NuVo

Fig. 21

Systems' lineouts. It can be used with either the fixed or variable

 

lineouts on the Essentia with either a 1/8” (3.5mm) to 1/8”

 

stereo patch cable or a 1/8” stereo to RCA patch cable, Fig 21.

 

There are two methods for triggering the P2100 from the Essentia

 

outputs. One is to set the POWER MODE switch on the P2100 to

 

Audio (the extreme left position) and allow an incoming audio

 

signal from the Essentia System to turn on the P2100. The second

 

method is to place the POWER MODE switch in the AC/DC

 

(extreme right) position. This will turn on the P2100 when the

 

Essentia is on. An additional feature of Essentia is zone specific

 

triggers that will trigger the P2100 only when that zone is turned

 

on.

 

Utilizing the voltage trigger requires a mono 1/8” (3.5mm) patch

Fig. 22

 

cable from either the System ON output on the Essentia to the

 

P2100 Voltage trigger input, or from the specific Zone Trigger on

 

the Essentia to the Voltage Trigger on the P2100, Fig. 22.

 

RS232 Interface

The RS232 port allows external two-waycommunication with the Essentia System. Home automation systems such as Crestron and AMX can be set up to operate Essentia. The RS232 addendum contains the necessary command sets for communication with the Essentia System.

NV-P2100Amplifier

AUDIO

 

 

 

CONTROL

L

 

SENSITIVITY

POWER

VOLTAGE

 

 

OdBV = 1.0RMS

 

 

 

 

MODE

TRIGGER

INPUT

LEFT

RIGHT

ON/OFF SWITCH

3-30VOLTS

0

 

0

AUDIO AC/DC

AC OR DC

2

 

 

 

 

 

R

 

 

 

 

 

 

+6

-12

+6

-12

 

INPUT OUTPUT

Essentia Amplifier

 

VARIABLE

 

 

VARIABLE

 

VARIABLE

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

 

 

OUTPUT POWER

 

 

OUTPUT POWER

 

OUTPUT POWER

 

TIP=L

 

20W/6OHM X2

TIP=L

 

20W/6OHM X2

TIP=L

20W/6OHM X2

 

RING=R

 

 

RING=R

 

RING=R

 

 

FIXED

 

 

FIXED

 

 

FIXED

 

 

OUTPUT

 

 

OUTPUT

 

OUTPUT

 

 

ZONE 1

 

 

ZONE 2

 

 

ZONE 3

 

1

2

3

4

5

6

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NV-E6DX

 

 

 

 

 

 

 

USE NV-SLC1

 

 

 

 

 

 

 

 

CABLE

 

1

2

3

4

5

6

 

 

 

 

 

SOURCE INPUTS

 

 

SOURCE LINK

 

NV-P2100Amplifier

 

AUDIO

 

 

 

CONTROL

 

L

 

SENSITIVITY

POWER

VOLTAGE

 

 

 

OdBV = 1.0RMS

 

 

 

 

 

MODE

TRIGGER

 

INPUT

LEFT

RIGHT

ON/OFF SWITCH

3-30VOLTS

 

0

 

0

AUDIO AC/DC

AC OR DC

 

2

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

+6

-12

+6

-12

 

INPUT

OUTPUT

 

 

 

 

 

 

 

Essentia

 

 

 

 

 

Amplifier

ZONE 6

 

 

 

 

ZONE 5

 

 

 

 

 

2

2

3

1

3

5

SUM1

1

 

 

 

 

 

 

 

5

4

5

6

2

4

6

SUM2

 

ZONE TRIGGER OUTPUTS

 

EMITTER OUTPUTS

 

19