NuTone CV400, SFDB-DC User Manual

0 (0)

CENTRAL VACUUM

POWER UNIT

! HOUSEHOLD TYPE !

CV400

MODEL NO. SFDB-DC

AB0022

HOMEOWNERS OPERATING INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS

Broan-NuTone LLC

Hartford, Wisconsin

www.nutone.com

888-336-3948

To register this product, visit www.nutone.com

30042420 Rev. E

IMPORTANT SAFETY INSTRUC-

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.

When using an electric appliance, basic precautions should always be followed, including the following:

WARNING !

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR PERSONAL INJURY:

Do not use on wet surfaces or outdoors.

Do not allow to be used as a toy. Close attention is necessary when used by or near children.

Use only as described in this manual. Use only manufacturer's recommended attachments.

Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.

Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.

Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

Do not use without dustbag or filter in place.

Do not use to blow leaves or debris.

Do not vacuum liquids or fine powders (such as drywall dust).

Do not put any object on the unit.

Ensure air flows freely to both side intake vents and exhausts unobstructed from top outlet.

Do not install the unit horizontally.

Do not use the pail as a wash pail.

Do not use the pail as a stool.

Turn off all controls before unplugging.

Use extra care when cleaning on stairs.

Avoid picking up sharp objects.

Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.

Do not use with damaged cord or plug. If appliance is not working as it should, if it has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.

• Do not unplug the unit by pulling on cord. To unplug, grasp the plug, not the cord.

Do not handle plug or appliance with wet hands.

Connect to a properly grounded outlet only. See grounding instructions on page 8.

Any servicing other than that recommended in this manual should be performed by an authorized service facility.

We recommend that your unit be inspected by a specialized technician once a year.

SAVE THESE INSTRUCTIONS

- 2 -

1. OPERATION

The power unit is located away from the everyday living areas of your home — usually in the garage, basement, or utility room. Through a network of strong, lightweight tubing, the power unit connects to inlets strategically placed throughout your home. When you are ready to clean, attach the wand and cleaning tool onto the end of the hose. Open the inlet cover and insert the end of the hose into the inlet. For non-switched hoses: inserting the hose automatically turns on the power unit; removing the hose shuts off the power unit. Some hoses have switches which can be used to activate the power unit. As you vacuum, dirt and dust are transported to the power unit where they remain in a disposable bag.

NOTE: The rocker switch on the front of the power unit can be used to turn the power unit on.

Use the cleaning tools as you would for any other vacuum cleaner. Avoid picking up pine needles, coffee sticks and other similar objects. These kinds of objects may become lodged in the hose or tubing.

2. DETAILED VIEW

ROCKER SWITCH

EXHAUST OUTLET

SECONDARY FILTER

INLET

 

INLET CHAMBER

BAG ADAPTER

 

DISPOSABLE BAG

LATCH

DEBRIS PAIL

AL0004

- 3 -

NuTone CV400, SFDB-DC User Manual

3. WHEN TO CHANGE BAG

With a 6 U.S. Gallons capacity, under normal conditions the bag requires changing approximately twice a year. If the bag is filled, you will notice a complete loss of vacuum in the system. Unless this loss of vacuum is caused by a blockage in the system, changing the bag will solve the problem.

NOTE: Even if not filled to capacity, if the bag seems tightly stretched when removing the debris pail, changing the bag will prevent it from tearing.

4. BAG REPLACEMENT

1.

To remove the disposable bag, release both latches

 

 

on sides of the unit by pulling out and then

 

 

pushing up. Remove the pail from unit. Grasp the

 

 

edges of the bags’ collar and pull down. The bag

 

 

will slide off easily. Do not pull on the bag.

 

2.

Unfold new bag.

 

3.

Grasp collar where indicated on the bag and insert

 

 

over bag adapter. Be careful not to tear the bag.

 

 

Ensure that the collar is positioned between the

 

 

taper ring and the bag stopper on the bag adapter

 

 

(see illustration below). Put the pail back in its place.

AA0004

 

 

NOTE : A set of 3 replacement bags (model 391) may be purchased from you local NuTone Sales Outlet. To locate your nearest NuTone Sales Outlet, call toll free 1-888-336-3948.

 

TAPER RING

 

AO0026

BAG STOPPER

AO0032

 

 

 

- 4 -

5. SECONDARY FILTER

A secondary safety filter, located at the top of the inlet chamber provides protection against dirt being pulled into the motor if the disposable bag should accidentally be torn. This filter should be checked and cleaned if necessary, when replacement bag is installed. Simply brush filter clean. If the filter is excessively soiled, wash in a mild detergent and let it dry completely before reinstalling.

CAUTION

Operating the power unit without the secondary filter will void the warranty.

5.1 REMOVING FILTER

Remove debris pail and disposable bag. Remove both locking sleeves from the retaining hooks. Carefully pull filter down to remove.

5.2 REINSTALLING FILTER

To reinstall the secondary filter, reverse the steps described above.

SECONDARY

FILTER

RETAINING

HOOKS

LOCKING

SLEEVES

AO0033

NOTE: A replacement secondary filter (part no. 10941310) may be purchased from you local NuTone Sales Outlet. To locate your nearest NuTone Sales Outlet, call toll free 1-888-336-3948.

! WARNING

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

- 5 -

6. POWER UNIT INSTALLATION

6.1 LOCATING THE POWER UNIT

Locate the power unit away from the general living area in an accessible location for cleaning and maintenance.

Locate the power unit within 6 feet of a grounded electrical outlet. The power unit requires a 120 VAC power source.

Do not locate the power unit close to a source of extreme heat (i.e.: water heater) or in an area with a high ambient temperature (i.e.: attic, furnace room).

Do not locate the power unit where the temperature can drop below 0°C (32°F).

If the power unit is located in a closet or a small utility room, make sure the area is well-ventilated (i.e.: with door louvers).

NOTE: Refer to NuTone website for information on tubing installation (www.nutone.com).

6.2 MOUNTING POWER UNIT

CAUTION

Make sure to assemble the wall mounting bracket with the screws directly onto a wall stud for a solid installation.

1.Carefully remove debris pail from power unit. Make sure bag is properly installed in power unit. Remove accessories and installation kit. Securely reinstall pail.

2.Install the 3-way elbow on the back of the power unit and press firmly (do not glue). Remove the plastic cap from the inlet opening only if your installation requires the connection into both inlets.

3-WAY ELBOW

DO NOT GLUE

REMOVE

PLASTIC CAP

(IF NEED BE)

AO0034

3.Install mounting bracket on a wall stud within 6 feet of a grounded electrical outlet, at the distances specified on illustration beside. Ensure that wall between mounting bracket and inlet is straight and leveled.

MINIMUM WALL CLEARANCE

DIMENSIONS

 

14" MIN.

PVC TUBING STRAP

 

INLET

INLET

 

EXHAUST

TOP VIEW

 

CEILING

 

12" MINIMUM TO CEILING

 

WALL BRACKET

 

EXHAUST

 

12"

INLET

INLET

30"

 

50"

 

FRONT VIEW

 

18" MINIMUM ABOVE FLOOR

FLOOR

 

AD0043A

 

- 6 -

Loading...
+ 14 hidden pages