NTRN10AN
Nortel Networks
OPTera Metro 3500
Multiservice Platform
Release 12.1 Planning and Ordering
Guide—Part 1 of 2
Standard Issue 1 April 2004
What’s inside...
Overview
Operation, administration, and maintenance (OAM) features Hardware feature descriptions
See Part 2 for the following...
Technical specifications
Engineering rules
Cable and connector details
Shelf mounting guidelines
Ordering information
Terms and conditions
Glossary
*A0549426*
Copyright 2000–2004 Nortel Networks, All Rights Reserved
The information contained herein is the property of Nortel Networks and is strictly confidential. Except as expressly authorized in writing by Nortel Networks, the holder shall keep all information contained herein confidential, shall disclose the information only to its employees with a need to know, and shall protect the information, in whole or in part, from disclosure and dissemination to third parties with the same degree of care it uses to protect its own confidential information, but with no less than reasonable care. Except as expressly authorized in writing by Nortel Networks, the holder is granted no rights to use the information contained herein.
Nortel Networks, the Nortel Networks logo, the Globemark, OPTera, and Preside are trademarks of Nortel Networks. ACE/Server, RSA, and SecurID are trademarks of RSA Security Inc.
Hewlett-Packard, HP, and HP-UX are trademarks of Hewlett-Packard Company. Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation.
Solaris, Sun, Sun Blade, Sun Microsystems, and Ultra are trademarks of Sun Microsystems, Inc.
SPARC is a trademark of SPARC International Inc. Telcordia, TIRKS, and NMA are trademarks of Telcordia Technologies, Inc. Pentium is a trademark of Intel Corporation.
Printed in Canada
|
|
|
|
iii |
|
|
|
|
|
Contents |
|
|
|
|
|
|
|
||
|
About this document |
ix |
||
|
Supported software |
ix |
|
|
|
Supported hardware |
x |
|
|
|
Technical support and information xii |
|
||
|
|
|
|
|
|
Overview |
|
|
1-1 |
|
Network element overview |
1-1 |
|
|
|
Release 12.1 features 1-4 |
|
||
|
Release 12.1 Hardware Compatibility Matrix 1-16 |
|
||
|
Supported configurations |
1-19 |
|
|
|
Interworking 1-25 |
|
|
|
|
Supported upgrade paths |
1-26 |
|
|
|
|
|
||
|
Operation, administration, and maintenance (OAM) features |
2-1 |
||
|
Gigabit Ethernet Drop and Continue 2-3 |
|
||
|
Alarm provisioning 2-5 |
|
|
|
|
Alarm flow control |
2-6 |
|
|
|
Environmental alarms |
2-7 |
|
|
|
External controls |
2-7 |
|
|
ACO switch — clearing audible alarms and performing lamp tests 2-7
Bandwidth management |
2-7 |
|
|
|
Tributary, DWDM, BLSR, UPSR, and 1+1 linear point-to-point |
2-8 |
|||
BLSR 2-9 |
|
|
|
|
Connection editing 2-9 |
|
|
|
|
In-service traffic rollover 2-9 |
|
|
|
|
BLSR networks (2-fiber) |
2-10 |
|
|
|
Protection 2-11 |
|
|
|
|
’Infinite wait-to-restore’ |
parameter 2-12 |
|
|
|
BLSR Line Protection Oscillation Control |
2-13 |
|
||
BLSR single span fiber cut scenario 2-13 |
|
|
||
BLSR nodal / multi-span failure scenario (involves squelching) |
2-25 |
|||
BLSR configurations 2-29 |
|
|
|
|
BLSR configuration and connection audit |
2-30 |
|
||
Traffic flow over OC-48 BLSR |
2-31 |
|
|
|
Traffic flow over OC-192 BLSR |
2-32 |
|
|
|
Provisioning rules 2-34 |
|
|
|
OAM supported on BLSR 2-43
Channelized DS3 service (DS3VTx12 mapper) 2-44
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
iv Contents
Common Language Location Identifier |
2-44 |
|
||||||
Connection ID |
2-45 |
|
|
|
|
|
||
Consolidated load |
2-45 |
|
|
|
|
|||
Dense wavelength division multiplexing (DWDM) 2-46 |
|
|||||||
OMX module |
2-48 |
|
|
|
|
|||
Network sites |
2-49 |
|
|
|
|
|||
DWDM configurations |
2-50 |
|
|
|
||||
Facility attributes |
2-54 |
|
|
|
|
|||
Loopbacks 2-54 |
|
|
|
|
|
|
|
|
Terminal loopback |
2-54 |
|
|
|
||||
Facility loopback |
|
2-54 |
|
|
|
|
||
Optical loopback |
|
2-55 |
|
|
|
|
||
Network surveillance |
2-58 |
|
|
|
||||
Extended network processor (NPx) |
2-58 |
|
||||||
Telemetry byte-oriented serial (TBOS) |
2-59 |
|
||||||
Path trace |
2-60 |
|
|
|
|
|
|
|
Section trace |
2-61 |
|
|
|
|
|||
TID address resolution protocol (TARP) |
2-61 |
|
||||||
OPTera Packet Edge System (Resilient Packet Ring) - Ethernet 2-62 |
|
|||||||
Connectors |
2-62 |
|
|
|
|
|
||
Resilient packet ring (RPR) object 2-63 |
|
|||||||
Optical Ethernet / Layer 2 (OE/L2) on OPTera Packet Edge System |
2-64 |
|||||||
RPR configuration alert |
2-65 |
|
|
|
||||
Auto save notification 2-65 |
|
|
|
|||||
NNI Filters increased to 2048 2-66 |
|
|
|
|||||
Optical Ethernet-Private Line (OE-PL) services using 10/100 Ethernet |
2-66 |
|||||||
2x100BT-P2P circuit pack 2-66 |
|
|
|
|||||
PPP over SONET |
2-67 |
|
|
|
||||
PPP and HDLC |
2-67 |
|
|
|
|
|||
Bridge Control Protocol |
2-69 |
|
|
|
||||
Network protection using UPSR, 1+1 linear and BLSR 2-69 |
|
|||||||
OAMP support |
|
2-70 |
|
|
|
|
||
Ethernet Operational Measurements |
2-70 |
|
Optical Ethernet-Private Line (OE-PL) service using 2x1000 SX/LX OPE circuit
packs 2-71 |
|
|
|
|
|
Distributed multilink trunking |
2-72 |
|
|
||
Bandwidth Reservation Protocol (BRP) 2-72 |
|
||||
1024 TDIs on a mapped UNI |
2-72 |
|
|
||
Optical Ethernet - Private Line (OE-PL) and Storage applications |
2-73 |
||||
2xGigE/FC-P2P circuit pack |
2-73 |
|
|
||
Alarm management 2-74 |
|
|
|
||
Bandwidth management |
2-84 |
|
|
||
Facility attributes |
2-85 |
|
|
|
|
Ethernet Operational Measurements 2-90 |
|
|
|||
Performance Monitoring |
2-95 |
|
|
||
Fibre Channel Extended Reach 2-95 |
|
|
|||
Generic Framing Procedure and Virtual Concatenation support |
2-99 |
||||
Optical interoperability of OPTera Metro 3500 |
2-102 |
|
|||
Performance monitoring 2-102 |
|
|
|
||
SONET line, section, and path parameters |
2-102 |
|
|||
Threshold values |
2-103 |
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Contents v
Retrieving performance monitoring counts |
2-110 |
|
|
|
|||||||
Physical PMs |
2-111 |
|
|
|
|
|
|
|
|
||
Performance monitoring threshold crossing alerts (TCA) |
2-114 |
|
|||||||||
TCAs 2-114 |
|
|
|
|
|
|
|
|
|
|
|
TCA summary alarms |
2-114 |
|
|
|
|
|
|
||||
Site Manager support |
2-116 |
|
|
|
|
|
|
||||
Preside Software Upgrade Management support 2-116 |
|
|
|||||||||
Preside Applications Platform and Multiservice MOA support |
2-117 |
|
|||||||||
Protection switching |
2-118 |
|
|
|
|
|
|
|
|||
Protection hierarchy 2-119 |
|
|
|
|
|
|
|||||
Protection performance monitoring parameters for optical facilities 2-120 |
|||||||||||
Security and administration |
2-122 |
|
|
|
|
|
|||||
Local account user authentication 2-122 |
|
|
|
|
|||||||
Local ‘challenge-response’ user authentication 2-123 |
|
|
|||||||||
Centralized Security Administration (CSA) |
2-124 |
|
|
|
|||||||
Centralized user administration and authentication through RADIUS |
2-125 |
||||||||||
SecurID support 2-128 |
|
|
|
|
|
|
|
||||
Secure storage of authentication data |
2-128 |
|
|
|
|||||||
Saving and restoring provisioning data |
2-129 |
|
|
|
|||||||
Local TL1 of provisioning data |
2-129 |
|
|
|
|
|
|||||
Save and restore of shelf processor or span of control data to a remote |
|||||||||||
management entity through an IP connection |
2-129 |
|
|
||||||||
Application of TL1 commands from a TL1 script file |
2-130 |
|
|||||||||
Security levels |
2-130 |
|
|
|
|
|
|
|
|
||
Third Level 5 User Support/Increased NPx SOC visibility to 16 NEs |
2-131 |
||||||||||
System identifier (SID) |
2-131 |
|
|
|
|
|
|
||||
Remote login |
2-132 |
|
|
|
|
|
|
|
|
||
Multiple login sessions |
2-132 |
|
|
|
|
|
|
||||
Enhanced Intrusion Detection |
2-133 |
|
|
|
|
|
|||||
Intrusion attempt handling |
2-134 |
|
|
|
|
|
|||||
Password management |
2-135 |
|
|
|
|
|
|
||||
Customer managed networks |
2-137 |
|
|
|
|
|
|||||
Security log audit trail |
2-138 |
|
|
|
|
|
|
||||
General Broadcast tool |
2-139 |
|
|
|
|
|
|
||||
Modifiable Login Banner |
2-140 |
|
|
|
|
|
|||||
STS Managed DSM |
2-142 |
|
|
|
|
|
|
|
|||
Support for 12 DSM |
2-146 |
|
|
|
|
|
|
|
|||
Synchronization |
2-146 |
|
|
|
|
|
|
|
|
||
Internal timing |
2-147 |
|
|
|
|
|
|
|
|
||
External timing |
2-147 |
|
|
|
|
|
|
|
|
||
Line timing |
2-147 |
|
|
|
|
|
|
|
|
|
|
Timing modes |
2-149 |
|
|
|
|
|
|
|
|
||
Stratum clocks |
2-150 |
|
|
|
|
|
|
|
|
||
Synchronization hierarchy |
2-150 |
|
|
|
|
|
|||||
Hierarchy violations 2-151 |
|
|
|
|
|
|
|||||
Timing loops |
2-151 |
|
|
|
|
|
|
|
|
||
Building-integrated timing supply (BITS) |
2-153 |
|
|
|
|||||||
Network element synchronization modes |
2-153 |
|
|
|
|||||||
Timing sources and timing distribution |
2-155 |
|
|
|
External timing reference input signals to STX and VTX-series circuit packs 2-156
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
vi Contents
Synchronization-status messages 2-156 |
|
|
||
User-specified quality levels for timing sources 2-158 |
|
|
||
BITS output with VTX-series or STX-192 circuit packs 2-158 |
|
|||
User-initiated synchronization switches |
2-158 |
|
|
|
Test Access 2-160 |
|
|
|
|
Test Access Ports (TAPs) |
2-161 |
|
|
|
Test access configurations |
2-162 |
|
|
|
Monitoring test access 2-162 |
|
|
|
|
Split test access 2-165 |
|
|
|
|
Loss of association and auto recovery |
2-167 |
|
|
|
User interface 2-168 |
|
|
|
|
Time of day synchronization |
2-169 |
|
|
|
TL1 Changes to Cross Connect AID parameter 2-172 |
|
|
||
TL1 event exerciser 2-173 |
|
|
|
|
TL1 event / log feature 2-173 |
|
|
|
|
Database change events |
2-174 |
|
|
|
Log events 2-174 |
|
|
|
|
Inventory events 2-174 |
|
|
|
|
ATAG sequence numbers |
2-175 |
|
|
|
Topology enhancements 2-175 |
|
|
|
|
VT management option on STX equipped OPTera Metro 3500 |
2-175 |
|
||
VT management on a UPSR 2-175 |
|
|
|
|
VT grooming on a UPSR |
2-181 |
|
|
|
Collocated OPTera Metro 3000 NE and dedicated STS at each site |
2-184 |
|||
Collocated OPTera Metro 3000 NE and shared VT-managed STS |
2-186 |
|||
UPSR planning guidelines summary 2-189 |
|
|
||
General guidelines 2-189 |
|
|
|
|
Physical subtending rings |
2-189 |
|
|
|
Virtual rings across the STS-managed OPTera Metro 3500 backbone |
||||
network 2-189 |
|
|
|
|
VT grooming at an STS-managed OPTera Metro 3500 site |
2-189 |
|
||
|
|
|
|
|
Hardware feature descriptions |
|
|
3-1 |
|||
Extended Reach (ZX) Small Form Factor Pluggable (SFP) |
3-3 |
|
||||
OPTera Metro 3500 Shelf and the OPTera Metro 3500 Universal Shelf |
3-4 |
|||||
Shelves equipped with VTX-48 or VTX-48e circuit packs |
3-4 |
|
||||
Shelves equipped with STX-192 circuit packs |
3-5 |
|
|
|||
Replaceable I/O modules 3-26 |
|
|
|
|
||
Common modules |
3-37 |
|
|
|
|
|
Left OAM (LOAM) |
3-37 |
|
|
|
|
|
Left interface (LIF) |
3-38 |
|
|
|
|
|
OPTera Metro 3500 cooling unit assembly and cooling unit fan modules |
3-40 |
|||||
Universal cooling unit assembly and cooling unit fan modules for extended |
||||||
temperature applications |
3-41 |
|
|
|
||
20 A (Universal) power module |
3-42 |
|
|
|
||
OPTera Metro 3000 breaker interface panel (BIP) |
3-42 |
|
|
|||
OPTera Metro 3500 BIP (European deployment) |
3-44 |
|
|
|||
STX-192 circuit pack |
3-51 |
|
|
|
|
|
Equipping rules |
3-51 |
|
|
|
|
|
VTX-48 circuit pack |
|
3-54 |
|
|
|
|
Equipping rules |
3-55 |
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Contents vii
VTX-48e circuit pack |
3-55 |
|
|
|
||
Equipping rules |
3-56 |
|
|
|
||
Extended shelf processor (SPx) |
3-56 |
|
||||
TL1 sessions |
3-56 |
|
|
|
|
|
Alarms and TBOS |
3-57 |
|
|
|
||
Reset button |
3-57 |
|
|
|
|
|
Section data communication channel (SDCC) |
3-57 |
|||||
Equipping rules |
3-57 |
|
|
|
||
Extended network processor (NPx) |
3-57 |
|
||||
TL1 sessions |
3-58 |
|
|
|
|
|
Alarms and provisioning data |
3-58 |
|
||||
Reset button |
3-58 |
|
|
|
|
|
Equipping rules |
3-59 |
|
|
|
||
ILAN interface |
3-59 |
|
|
|
|
|
Equipping rules |
3-59 |
|
|
|
||
OC-192 optical interface circuit pack 3-59 |
|
|||||
STS-1 path trace for OC-192 |
3-60 |
|
||||
Section trace for OC-192 3-60 |
|
|
||||
Section data communication channel (SDCC) |
3-60 |
|||||
Forward Error Correction (FEC) |
3-60 |
|
||||
Equipping rules |
3-62 |
|
|
|
||
OC-192 protection switching |
3-62 |
|
OC-192 DWDM G.709 FEC optical interface circuit pack 3-64
Section data communication channel (SDCC) |
3-64 |
||||
Forward Error Correction (FEC) |
3-64 |
|
|||
Equipping rules |
3-65 |
|
|
|
|
OC-48 optical interface circuit pack |
3-65 |
|
|||
STS-1 path trace for OC-48 |
3-65 |
|
|||
Section trace for OC-48 |
3-66 |
|
|
||
Section data communication channel (SDCC) |
3-66 |
||||
Equipping rules |
3-66 |
|
|
|
|
OC-48 protection switching |
3-67 |
|
|||
OC-48 STS optical interface circuit pack 3-68 |
|
||||
STS-1 path trace for OC-48 |
3-69 |
|
|||
Section trace for OC-48 |
3-69 |
|
|
||
Section data communication channel (SDCC) |
3-69 |
||||
Equipping rules |
3-70 |
|
|
|
|
OC-48 protection switching |
3-70 |
|
|||
OC-48 DWDM circuit pack |
3-71 |
|
|
||
Section data communication channel (SDCC) |
3-71 |
||||
Equipping rules |
3-72 |
|
|
|
|
OC-12 optical interface circuit pack |
3-72 |
|
|||
Equipping rules |
3-73 |
|
|
|
|
OC-12 Protection switching |
3-73 |
|
|||
Section data communication channel (SDCC) |
3-74 |
||||
OC12x4 STS IR optical interface circuit pack 3-75 |
|||||
Multimode Interworking |
3-75 |
|
|
||
Equipping rules |
3-76 |
|
|
|
|
Section data communication channel (SDCC) |
3-77 |
||||
OC-3 optical interface circuit pack |
3-77 |
|
|||
Equipping rules |
3-78 |
|
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
viii Contents
OC-3 Protection switching 3-78 |
|
|
|
Section data communication channel (SDCC) |
3-79 |
||
OC-3x4 optical interface circuit pack 3-80 |
|
|
|
Multimode Interworking 3-80 |
|
|
|
Equipping rules |
3-81 |
|
|
Section data communication channel (SDCC) |
3-82 |
||
EC-1x3 circuit pack |
3-82 |
|
|
Equipping rules |
3-83 |
|
|
Protection switching 3-83 |
|
|
|
Section data communication channel (SDCC) |
3-83 |
||
EC-1x12 circuit pack 3-84 |
|
|
|
Equipping rules |
3-84 |
|
|
Protection switching 3-85 |
|
|
|
Section data communication channel (SDCC) |
3-85 |
||
DS1 mapper 3-86 |
|
|
|
Equipping rules |
3-86 |
|
|
DS3x3 mapper 3-87 |
|
|
|
Equipping rules |
3-87 |
|
|
Protection switching 3-88 |
|
|
|
DS3x12 / DS3x12e mapper 3-89 |
|
|
|
Equipping rules |
3-89 |
|
|
DS3VTx12 mapper |
3-90 |
|
|
Equipping rules |
3-91 |
|
|
DS3/VT protection switching 3-91 |
|
|
|
2x100BT-P2P circuit pack 3-91 |
|
|
|
Equipping rules |
3-92 |
|
|
OPTera Packet Edge System 4x100BT circuit pack |
3-94 |
||
Equipping rules |
3-94 |
|
|
OPTera Packet Edge System 4x100FX circuit pack |
3-96 |
||
Equipping rules |
3-96 |
|
|
OPTera Packet Edge System 2xGigE (2x1000SX, 2x1000LX) circuit pack 3-97
Equipping rules |
3-97 |
|
2xGigabit Ethernet/Fibre Channel - Point-to-Point circuit pack 3-98 |
||
Equipping rules |
3-98 |
|
Protection switch controller (PSC) |
3-100 |
|
Equipping rules |
3-100 |
|
Protection switch extender (PSX) |
3-101 |
|
Equipping rules |
3-101 |
|
OMX + Fiber Manager 4CH 3-101 Enhanced OMX + Fiber Manager 4CH 3-102
OMX shelf (not required with OMX + Fiber Manager 4CH) 3-103 Equipping rules 3-103
Fiber Manager (not required with OMX + Fiber Manager 4CH) 3-104 DS1 service module (DSM) shelf 3-107
Equipping rules 3-107 Multiple IS 3-107
DSM DS1x84 termination module (TM) 3-111 Equipping rules 3-111
Protection switching 3-112
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
ix
ATTENTION
This document is presented in two parts: Part 1 and Part 2. Each part has its own table of contents. The table of contents in Part 1 contain topics found in Part 1 only. The table of contents in Part 2 contain topics found in Part 2 only. Part 2 continues sequential chapter numbering from Part 1.
You are reading Part 1 of Nortel Networks OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN.
Part 1 of OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN covers a network element overview and new features in Release 12.1, operation, administration, and maintenance (OAM) features, and hardware description features.
Part 2 of OPTera Metro 3500 Multiservice Platform Release 12.1 Planning and Ordering Guide, NTRN10AN covers technical specifications, engineering rules, cable and connector details, shelf mounting guidelines, ordering information, terms and conditions, and a glossary.
Standards
The Telecommunications Industry Association (TIA) and the Electronics Industries Alliance (EIA) accepted RS-232 as a standard in 1997 and renumbered this standard as TIA/EIA-232. In this document, RS-232 is used to reflect current labels on the hardware and in the software for the OPTera Metro 3500 Multiservice Platform.
This document supports the software release for OPTera Metro 3500 Release 12.1.
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
x About this document
This document supports the OPTera Metro 3500 shelves (NTN476AA, NTN476DA) and the Universal OPTera Metro 3500 shelf (NTN476AH).
Note: The OPTera Metro 3500 shelf NTN476AA must be upgraded using the power module and cooling upgrade kit (NTN458MW) to support OC-192 optical interfaces.
Hardware naming conventions
The following naming conventions are used throughout this document to identify the OPTera Metro 3500 hardware:
•The extended shelf processor (SPx) is referred to as the shelf processor.
•The extended network processor (NPx) is referred to as the network processor.
Audience
The following members of your company are the intended audience of this Nortel Networks technical publication (NTP):
•planners
•provisioners
•network administrators
•transmission standards engineers
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
About this document xi
OPTera Metro 3500 NTP library
Guides and |
TL1 Reference |
Operations, |
Shelf Setup |
|
Administration |
|
|
and Provisioning |
About the |
TL1 Reference |
System |
OPTera Metro 3500 |
(323-1059-190) |
Reconfiguration |
NTP Library |
|
(323-1059-224) |
(323-1059-090) |
|
Security and |
Planning and |
|
|
|
Administration |
|
Ordering Guide |
|
(323-1059-302) |
(NTRN10AN) |
|
Provisioning |
Network |
|
|
|
Synchronization |
|
Interworking Guide |
|
(323-1059-310) |
(NTCA68CA) |
|
Protection |
|
|
|
OPTera Metro 3500 |
|
Switching |
Network |
|
(323-1059-311) |
InteroperabilityGuide |
|
Bandwidth |
(NTRN16AA) |
|
|
|
|
Management |
Installation |
|
(323-1059-320) |
(323-1059-201) |
|
Provisioning |
|
|
|
Commissioning |
|
Equipment and |
(323-1059-210) |
|
Facilities |
|
|
(323-1059-350) |
System Testing |
|
|
(323-1059-222) |
|
|
|
EX1541p |
|
Maintenance |
Supporting |
|
|
documentation |
|
|
for the OPTera |
|
|
Metro 3500 |
|
|
Library |
|
|
Change Application |
|
|
Procedures |
|
|
(CAPs) |
|
|
Data |
|
|
Communications |
|
|
Network Planning |
|
|
Guide |
|
|
(NTR710AM) |
|
Performance |
OPTera Metro |
|
Monitoring |
3000 series |
|
(323-1059-510) |
DWDM Application |
|
Network |
Guide |
|
(NTRN12AA) |
||
Surveillance |
OPTera Packet Edge |
|
(323-1059-520) |
||
System Planning |
||
|
||
Alarm and |
Guide |
|
Trouble Clearing |
(NTRN10YK) |
|
(323-1059-543) |
OPTera Packet Edge |
|
|
||
|
System Network |
|
|
Applications and |
|
|
Management |
|
|
(NTRN11YK) |
|
|
OPTera Packet Edge |
|
|
System User Guide |
|
|
(NTN465YG) |
|
|
Site Manager |
|
|
Planning and |
|
|
Installation Guide, |
|
|
Rel 6.0 |
|
|
(NTNM35FA) |
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
xii About this document
For technical support and information from Nortel Networks, refer to the following table.
Technical Assistance Service
For service-affecting problems: |
North America: |
|
For 24-hour emergency recovery or software upgrade |
1-800-4NORTEL (1-800-466-7835) |
|
support, that is, for: |
|
|
• restoration of service for equipment that has been carrying |
International: |
|
traffic and is out of service |
||
001-919-992-8300 |
||
|
||
• issues that prevent traffic protection switching |
|
|
• issues that prevent completion of software upgrades |
|
|
|
|
|
For non-service-affecting problems: |
North America: |
|
For 24-hour support on issues requiring immediate support |
1-800-4NORTEL (1-800-466-7835) |
|
or for 14-hour support (8 a.m. to 10 p.m. EST) on upgrade |
Note: You require an express routing |
|
notification and non-urgent issues. |
||
code (ERC). To determine the ERC, see |
||
|
||
|
our corporate Web site at |
|
|
www.nortelnetworks.com. Click on the |
|
|
Express Routing Codes link. |
|
|
International: |
|
|
Varies according to country. For a list of |
|
|
telephone numbers, see our corporate |
|
|
Web site at www.nortelnetworks.com. |
|
|
Click on the Contact Us link. |
|
|
|
|
Global software upgrade support: |
North America: |
|
|
1-800-4NORTEL (1-800-466-7835) |
|
|
International: |
|
|
Varies according to country. For a list of |
|
|
telephone numbers, see our corporate |
|
|
Web site at www.nortelnetworks.com. |
|
|
Click on the Contact Us link. |
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-1
The Nortel Networks OPTera Metro 3500 network element is a multiservice platform offering dense wavelength division multiplexing (DWDM) with a wide variety of services: DS1, DS3, Channelized DS3, EC-1, OC-3, OC-12, OC-48, OC-192, 10/100BASE-T Ethernet, 100BASE-FX Ethernet, Gigabit Ethernet and Fibre Channel.
OPTera Metro 3500 is a next generation SONET multiservice platform. It provides full OC-192 connectivity to customer premise locations.
On the physical layer (layer 1), an OPTera Metro 3500 network can be configured as a unidirectional path-switched ring (UPSR), a 1+1 linear configuration, a 2-fiber bidirectional line-switched ring (BLSR), or as an unprotected fiber optic run.
On the data link layer (layer 2), an OPTera Metro 3500 network can be configured as an OPTera Packet Edge ring with layer 2 protection, in accordance with Resilient Packet Rings (RPR) currently being defined by the IEEE 802.17 working group.
OPTera Metro Release 12.0 introduced a new STX-192 switch matrix circuit pack. The STX-192 circuit pack is a fully non-blocking STS switch matrix and clocking module providing switching capability for 40 Gbit/s. The STX-192 provides support for 10 Gbit/s links to the line slots 11 and 12 and up to 2.5 Gbit/s links to slots 3 through 10.
For STX based configurations, the OPTera Metro 3500 is optimized for broadband services, namely Gigabit Ethernet, Storage Area Networking, and switched Ethernet services using Resilient Packet Ring. When configured for STX based configurations, the platform supports full TDM services as well, with full fill OC12 and OC48 densities. Furthermore, DS1 services are still possible via the DS1 Service Module (DSM). For STX based configurations where VT1.5 level management is required, a dual node configuration can be used where by a VTX based OPTera Metro 3500 is subtended from a STX based OPTera Metro 3500. Both nodes are managed via Site Manager, which provides end-to-end connection management capability.
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-2 Overview
Figure 1-1
OPTera Metro 3500 slot assignments (STX-192 installed in shelf)
EX1470p
Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10
I/O module slots
LOAM
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIF |
|
Empty |
Tributary |
Tributary |
|
Tributary |
Tributary |
Tributary |
Tributary |
|
Tributary |
|
Tributary |
OC-48 STS or OC-192 (See Note) |
|
|
OC-48 STS or OC-192 (See Note) |
|
STX-192 |
|
|
STX-192 |
|
|
SPx |
NPx or ILAN |
Empty |
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
Pwr A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
Pwr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slot 1 |
Slot 2 |
Slot 3 |
|
Slot 4 |
|
Slot 5 |
Slot 6 |
Slot 7 |
Slot 8 |
|
Slot 9 |
|
Slot 10 |
|
Slot 11 |
|
|
Slot 12 |
|
Slot 13 |
|
|
Slot 14 |
|
|
Slot 15 |
Slot 16 |
Slot 17 |
|
|
|
|
|
|
|
Note: The OC-48 STS circuit pack is a single-width circuit pack.
For VTX based configurations, the OM3500 is optimized for OC48 based TDM and Optical Ethernet applications, supporting full densities for all TDM services. Furthermore, with the completely non-blocking VT1.5 switch matrix, the platform is ideally suited for hybrid digital cross connect and add/drop multiplexer applications.
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Overview 1-3
Figure 1-2
OPTera Metro 3500 slot assignments (VTX-48/VTX-48e installed in shelf)
EX1040p
Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Slot 9 Slot 10
I/O module slots
LOAM
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIF |
|
PSC |
Tributary |
|
Tributary |
|
Tributary |
Tributary |
Tributary |
Tributary |
|
Tributary |
|
Tributary |
OC-48 or OC-12 (See Note) |
|
|
OC-48 or OC-12 (See Note) |
|
VTX-48 |
|
|
VTX-48 |
|
|
SPx |
NPx or ILAN |
PSX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
Pwr A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pwr B |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slot 1 |
Slot 2 |
Slot 3 |
Slot 4 |
|
Slot 5 |
Slot 6 |
Slot 7 |
Slot 8 |
|
Slot 9 |
|
Slot 10 |
|
Slot 11 |
|
|
Slot 12 |
|
Slot 13 |
|
|
Slot 14 |
|
|
Slot 15 |
Slot 16 |
Slot 17 |
|
|
|
|
|
|
|
|
|
Note: The OC-12 circuit pack is a single-width circuit pack.
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-4 Overview
The Release 12.1 OPTera Metro 3500 system offers the following new and enhanced features:
•Gigabit Ethernet Drop and Continue support on 2xGigE/FC-P2P interface
•Support for extended reach (ZX) small-form factor pluggable (SFP)
This document describes the applications and functionality available in
Release 12.1. See the following chapters for more detail:
•Chapter 1, Overview, gives a high level description of what is supported in this release.
•Chapter 2, Operation, administration, and maintenance (OAM) features, gives a high level description of OAM&P functionality.
•Chapter 3, Hardware feature descriptions, describes both shelves and their components.
•Chapter 4, Technical specifications (in Part 2 of this guide), lists the technical specifications for all circuit packs and equipment.
•Chapter 5, Engineering rules (in Part 2 of this guide), lists special engineering rules for interworking, DWDM, and Preside.
•Chapter 6, Cable and connector details (in Part 2 of this guide), lists the cables and components used on the shelf.
•Chapter 7, Shelf mounting guidelines (in Part 2 of this guide), describes typical installations.
•Chapter 8, Ordering information (in Part 2 of this guide), provides procedures and tables to simplify the ordering process.
•Chapter 9, Terms and conditions (in Part 2 of this guide), provides contacts to set up an order.
See Table 1-1 for a complete list of supported features in Release 12.1.
Table 1-1
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Network configurations |
|
|
|
|
|
Bidirectional line switched ring (BLSR) (2-fiber) at OC-192 rate |
No |
Yes |
|
|
|
Bidirectional line switched ring (BLSR) (2-fiber) at OC-48 rate |
Yes |
No |
|
|
|
BLSR with linear spur |
Yes |
Yes |
|
|
|
BLSR with subtending UPSR |
Yes |
Yes |
|
|
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-5 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Uni-directional Path switched Ring at OC3, OC-12, OC-48 or |
Yes |
Yes |
OC-192 rates |
except OC-192 |
|
|
|
|
Dual-homed subtending rings (on UPSR) |
Yes |
Yes |
|
|
|
Linear add/drop multiplexer OC-3, and OC-12, OC-48, and |
Yes |
Yes |
OC-192 rates |
except OC-192 |
except OC-192 |
|
|
|
Linear point-to-point at OC-3, OC-12, OC-48, and OC-192 |
Yes |
Yes |
rates |
except OC-192 |
|
|
|
|
Matched nodes (on UPSR) |
Yes |
Yes |
|
|
|
Mixed RPR and TDM traffic over BLSR |
Yes |
Yes |
|
|
|
Mixed RPR and TDM traffic over UPSR (and above UPSR |
Yes |
Yes |
variants) |
|
|
|
|
|
Optical hubbing |
Yes |
Yes |
|
|
|
Path-in-line (virtual ring) (across UPSR or BLSR) |
Yes |
Yes |
|
|
|
RPR over BLSR (working and protection channels) |
Yes |
Yes |
|
|
|
RPR over UPSR (and above UPSR variants) |
Yes |
Yes |
|
|
|
Single-homed subtending rings (on UPSR) |
Yes |
Yes |
|
|
|
UPSR to non-OPTera Metro 3500 BLSR interconnection |
Yes |
Yes |
|
|
|
In-service reconfigurations |
|
|
|
|
|
Adding a network element to an OC-48 or OC-192 BLSR |
Yes |
Yes |
|
except OC-192 |
except OC-48 |
|
|
|
Adding a network element to a UPSR |
Yes |
Yes |
|
except OC-192 |
|
|
|
|
Adding an OMX shelf to an in-service DWDM network |
Yes |
Yes |
|
|
|
Adding an OPTera Metro 3500 network element to an OC-48 |
Yes |
Yes |
UPSR over DWDM |
|
|
|
|
|
Adding an OPTera Metro 3500 network element to an OC-48 |
Yes |
No |
BLSR over DWDM |
|
|
|
|
|
Converting an OC-48 UPSR to an OC-48 UPSR over DWDM |
Yes |
Yes |
|
|
|
Converting an OC-48 BLSR to an OC-48 BLSR over DWDM |
Yes |
No |
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-6 Overview
Table 1-1 (continued)
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Converting an OC-48 linear point-to-point network to an |
Yes |
Yes |
OC-48 linear point-to-point network over DWDM |
|
|
|
|
|
Adding an OPTera Metro 3500 network element to an OC-192 |
No |
Yes |
UPSR over DWDM |
|
|
|
|
|
Converting an OC-192 UPSR to an OC-192 UPSR over |
No |
Yes |
DWDM |
|
|
|
|
|
Converting an OC-192 linear point-to-point network to an |
No |
Yes |
OC-192 linear point-to-point network over DWDM |
|
|
|
|
|
Converting a UPSR to a BLSR |
Yes |
Yes |
|
See Note 3 |
See Note 3 |
|
|
|
Converting a 1+1 linear point-to-point configuration to a |
Yes |
Yes |
2-node UPSR |
|
|
|
|
|
Converting a 2-node UPSR to a 1+1 linear point-to-point |
Yes |
Yes |
configuration |
|
|
|
|
|
Moving a synchronization boundary |
Yes |
Yes |
|
|
|
Removing a network element from an OC-48 or OC-192 BLSR |
Yes |
Yes |
|
except OC-192 |
except OC-48 |
|
|
|
Removing a network element from a UPSR |
Yes |
Yes |
|
|
|
Removing an OPTera Metro 3500 network element from an |
Yes |
No |
OC-48 BLSR over DWDM |
|
|
|
|
|
Removing an OPTera Metro 3500 network element from an |
Yes |
Yes |
OC-48 UPSR over DWDM |
|
|
|
|
|
Replacing a DS3x3 mapper with a DS3x12 / DS3x12e mapper |
Yes |
Yes |
|
|
|
Replacing an EC-1x3 circuit pack with an EC-1x12 circuit pack |
Yes |
Yes |
|
|
|
Replacing the ILAN circuit pack with a network processor |
Yes |
Yes |
|
|
|
Replacing the network processor with an ILAN circuit pack |
Yes |
Yes |
|
|
|
Upgrading a fiber span from an OC-3 to an OC-12 rate |
Yes |
Yes |
(See Note 2) |
|
|
|
|
|
Upgrading a fiber span from an OC-12 to an OC-48 rate |
Yes |
Yes |
(See Note 2) |
|
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-7 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Upgrading a fiber span from an OC-48 to an OC-192 rate |
No |
Yes |
|
|
See Note 3 |
|
|
|
Converting a VT-assigned BLSR connection to a Full VT |
Yes |
No |
BLSR connection |
|
|
|
|
|
Converting a Full VT BLSR connection to a VT-assigned |
Yes |
No |
BLSR connection |
|
|
|
|
|
Services |
|
|
|
|
|
DS1 |
Yes |
Yes |
|
|
|
DS3 |
Yes |
Yes |
|
|
|
DS3 (Channelized) |
Yes |
No |
|
|
|
EC-1 |
Yes |
Yes |
|
|
|
OC-3 |
Yes |
Yes |
|
|
|
OC-12 |
Yes |
Yes |
|
|
|
OC-48 |
Yes |
Yes |
|
|
|
OC-192 |
No |
Yes |
|
|
|
Optical Ethernet - Private Line service using 10/100 Ethernet |
Yes |
Yes |
|
|
|
Optical Ethernet - Private Line using Gigabit Ethernet |
Yes |
Yes |
|
|
full rate support |
|
|
|
OPTera Packet Edge System |
Yes |
Yes |
See: |
|
|
• OPTera Metro 3000 OPTera Packet Edge System User Guide |
|
|
(NTN465YG) |
|
|
• OPTera Packet Edge System Planning Guide (NTRN10YK) |
|
|
• OPTera Packet Edge System Network Applications and |
|
|
Management (NTRN11YK) |
|
|
|
|
|
Resilient Packet Ring (RPR) |
Yes |
Yes |
|
|
|
Storage Network (Fibre Channel (FC100) & FICON) |
Yes |
Yes |
|
|
|
Test Access Electrical and Optical TAPS (monitor and split |
Yes |
Yes |
states) |
|
|
|
|
|
Hardware (See Note 2) |
|
|
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-8 Overview
Table 1-1 (continued)
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
OPTera Metro 3500 Shelf Assembly (NTN476AA) |
Yes |
Yes |
|
|
See Note 4 |
|
|
|
OPTera Metro 3500 Shelf Assembly (NTN476DA) |
Yes |
Yes |
|
|
|
OPTera Metro 3500 Universal Shelf Assembly (NTN476AH) |
Yes |
Yes |
|
|
|
2x100BT-P2P circuit pack (NTN433AA) |
Yes |
Yes |
|
|
|
4x100FX (NTN4333EA, NTN433FA) |
Yes |
Yes |
|
|
|
4x100BT (NTN433BB) |
Yes |
Yes |
|
|
|
2x1000SX (NTN438AA) |
Yes |
Yes |
|
|
|
2x1000LX (NTN438BA) |
Yes |
Yes |
|
|
|
2xGigE/FC-P2P (NTN438DA) |
Yes |
Yes |
|
|
|
1000-BaseSX 850 nm SFP (NTTP51AA) |
Yes |
Yes |
|
|
|
1000-BaseLX 1310 nm SFP (NTTP51BD) |
Yes |
Yes |
|
|
|
1000-BaseZX 1550 nm SFP (NTTP51DZ) |
Yes |
Yes |
|
|
|
DS1 mapper (1:N protection) |
Yes |
No |
|
|
|
DS1 service module (DSM) (up to 12 protected or unprotected |
Yes |
Yes |
DSM on an NE) |
|
|
|
|
|
DS3 mapper |
No |
No |
See Note 5 |
|
|
|
|
|
DS3VTx12 mapper |
Yes |
No |
|
|
|
DS3x12 mapper (1+1 protection) |
Yes |
Yes |
|
|
|
DS3x12e mapper (1+1 protection) |
Yes |
Yes |
|
|
|
DS3x3 mapper (1+1 protection) (NTN437AA) |
Yes |
Yes |
|
|
|
DSM DS1x84 termination module (TM) |
Yes |
Yes |
|
|
|
EC-1 circuit pack |
No |
No |
See Note 5 |
|
|
|
|
|
EC-1x12 circuit pack (1+1 protection) |
Yes |
Yes |
|
|
|
EC-1x3 circuit pack (1+1 protection) (NTN436AA) |
Yes |
Yes |
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-9 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
OC-3 circuit pack in slots 11 and 12 (UPSR, 1+1 linear |
No |
No |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-3 circuit pack in slots 3 through 10 (UPSR, 1+1 linear |
Yes |
Yes |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-3x4 circuit pack in slots 11 and 12 (UPSR, 1+1 linear |
No |
No |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-3x4 circuit pack in slots 3 through 10 (UPSR, 1+1 linear |
Yes |
Yes |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-12 circuit pack in slots 11 and 12 (UPSR, 1+1 linear |
Yes |
No |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-12 circuit pack in slots 3 through 10 (UPSR, 1+1 linear |
Yes |
Yes |
point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-12x4 STS circuit pack in slots 11 and 12 (UPSR, 1+1 |
No |
No |
linear point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-12x4 STS circuit pack in slots 3 through 10 (UPSR, 1+1 |
No |
Yes |
linear point-to-point and 1+1 linear ADM) |
|
|
|
|
|
OC-48 circuit pack in slots 11 and 12 (BLSR, UPSR, 1+1 linear |
Yes |
No |
point-to-point) |
|
|
|
|
|
OC-48 circuit pack in slots 3 through 10 (UPSR, 1+1 linear |
No |
No |
point-to-point) |
|
|
|
|
|
OC-48 STS circuit pack in slots 3 to 12 (UPSR, 1+1 linear |
No |
Yes |
point-to-point) |
|
|
|
|
|
OC-48 DWDM circuit pack in slots 11 and 12 (BLSR, UPSR, |
Yes |
No |
1+1 linear point-to-point) |
|
|
|
|
|
OC-48 DWDM circuit pack in slots 3 through 10 (UPSR, 1+1 |
No |
No |
linear point-to-point) |
|
|
|
|
|
OC-192 circuit pack in slots 11 and 12 (BLSR, UPSR, 1+1 |
No |
Yes |
linear point-to-point) |
|
|
|
|
|
OC-192 circuit pack in slots 3 through 10 (UPSR, 1+1 linear |
No |
No |
point-to-point) |
|
|
|
|
|
STM-0 optical interface (1+1 protection) (in J-SDH mode) |
No |
No |
See Note 5 |
|
|
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-10 Overview
Table 1-1 (continued)
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
STM-1 optical interface (1+1 protection) (in J-SDH mode) |
No |
No |
See Note 5 |
|
|
|
|
|
STM-1x4 optical interface (in J-SDH mode) |
Yes |
Yes |
(in Slots 3 through 10) |
|
|
|
|
|
Intershelf LAN (ILAN) circuit pack |
Yes |
Yes |
|
|
|
Network Processor circuit pack (NP circuit pack) (NTN422AA) |
No |
No |
See Note 5 |
|
|
|
|
|
Network Processor circuit pack - extended (NPx circuit pack) |
Yes |
Yes |
(NTN424Bx) |
|
|
|
|
|
Shelf Processor circuit pack - terminal (SP circuit pack) |
No |
No |
(NTN420AA) |
|
|
See Note 5 |
|
|
|
|
|
Shelf Processor circuit pack - enhanced (SPe circuit pack) |
No |
No |
(NTN421BA) |
|
|
See Note 5 |
|
|
|
|
|
Shelf Processor circuit pack - extended (SPx circuit pack) |
Yes |
Yes |
(NTN423Bx) |
|
|
|
|
|
OMX shelf |
Yes |
Yes |
|
|
|
Performance monitoring |
|
|
|
|
|
DS1 line and path |
Yes |
Yes |
|
|
See Note 6 |
|
|
|
DS1e far-end line and path |
Yes |
Yes |
|
|
See Note 6 |
|
|
|
DS1e far-end line and path with F bit generation |
Yes |
Yes |
|
|
See Note 6 |
|
|
|
DS3 line and path |
Yes |
Yes |
|
|
|
DS3/VT line and path |
Yes |
No |
|
|
|
EC-1 section and line |
Yes |
Yes |
|
|
|
Path PMs on DS3x12e circuit pack |
Yes |
Yes |
|
|
|
OC-12 section and line |
Yes |
Yes |
|
|
|
OC-3 section and line |
Yes |
Yes |
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-11 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
OC-48 section and line |
Yes |
Yes |
|
|
|
OC-192 section and line |
No |
Yes |
|
|
|
Physical performance monitoring for OC-48 DWDM ER and |
Yes |
No |
ELR circuit pack-receiver |
|
|
|
|
|
Physical performance monitoring for OC-48 STS and OC-192 |
No |
Yes |
circuit pack-receiver |
|
|
|
|
|
STM-0 section and line (in J-SDH mode) |
No |
No |
See Note 5 |
|
|
|
|
|
STM-1 section and line (in J-SDH mode) |
Yes |
Yes |
See Note 5 |
|
|
|
|
|
STS-1 path |
Yes |
Yes |
|
|
|
STS-3c path |
Yes |
Yes |
|
|
|
STS-12c path |
Yes |
Yes |
See Note 7 |
|
|
|
|
|
STS-24c path |
No |
Yes |
|
|
|
STS48c path |
No |
Yes |
|
|
|
Ethernet Operational Measurements |
Yes |
Yes |
|
|
|
Security and administration |
|
|
|
|
|
User account creation |
Yes |
Yes |
|
|
|
Network element / network processor naming |
Yes |
Yes |
|
|
|
Time zone, date and time setting |
Yes |
Yes |
|
|
|
Maintenance and updating of accounts and network element |
Yes |
Yes |
parameters |
|
|
|
|
|
Intrusion attempt handling on the SPx and NPx |
Yes |
Yes |
|
|
|
Password management on the SPx and NPx |
Yes |
Yes |
|
|
|
Customer managed networks on the SPx and NPx |
Yes |
Yes |
|
|
|
Security log / audit trail |
Yes |
Yes |
|
|
|
Multiple authentication methods |
Yes |
Yes |
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-12 Overview
Table 1-1 (continued)
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Challenge / Response authentication |
Yes |
Yes |
|
|
|
Centralized authentication through a RADIUS server |
Yes |
Yes |
|
|
|
Third span of control surveillance |
Yes |
Yes |
|
|
|
General Broadcast tool |
Yes |
Yes |
|
|
|
Bandwidth management |
|
|
|
|
|
In-service traffic rollover for TDM traffic |
Yes |
Yes |
|
|
|
In-service traffic rollover for RPR traffic |
No |
No |
|
|
|
STS-1 traffic |
Yes |
Yes |
|
|
|
STS-3c traffic |
Yes |
Yes |
|
|
|
STS-12c traffic |
Yes |
Yes |
|
|
|
STS-24c traffic |
No |
Yes |
|
|
|
STS-48c traffic |
No |
Yes |
|
|
|
STS-48c, STS24c, STS-12c, STS-3c, STS-1 time slot |
Yes |
Yes |
assignment (TSA) on pass-through nodes on BLSR |
except STS24c & |
|
|
STS-48c |
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 |
Yes |
Yes |
broadcast on 1+1 linear, UPSR |
except STS24c & |
except VT1.5 |
|
STS-48c |
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 |
Yes |
Yes |
drop-and-continue on 1+1 linear, UPSR |
except STS24c & |
except VT1.5 |
|
STS-48c |
|
|
|
|
STS48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 |
No |
No |
drop-and-continue on BLSR |
|
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 |
Yes |
Yes |
hairpinning |
except STS24c & |
VT1.5 |
|
STS-48c |
|
|
|
|
STS-48c, STS-24c, STS-12c,STS-3c, STS-1, VT1.5 time slot |
Yes |
Yes |
assignment (TSA) on 1+1 linear, UPSR |
except STS24c & |
VT1.5 |
|
STS-48c |
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot |
Yes |
Yes |
assignment (TSA) on add/drop nodes on BLSR |
except STS-48c |
VT1.5 |
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-13 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot |
Yes |
Yes |
interchange (TSI) on 1+1 linear, UPSR |
except STS24c & |
VT1.5 |
|
STS-48c |
|
|
|
|
STS-48c, STS-24c, STS-12c, STS-3c, STS-1, VT1.5 time slot |
Yes |
Yes |
interchange (TSI) on BLSR |
except STS24c & |
VT1.5 |
|
STS-48c |
|
|
|
|
TU11, TU21, AU32, AU4 cross-connects (in J-SDH mode) |
Yes |
Yes |
|
|
supports AU32 |
|
|
and AU4 |
|
|
|
VT1.5/ time slot assignment (TSA) on pass-through nodes on |
Yes |
No |
BLSR |
|
|
|
|
|
VT6 cross-connects (in J-SDH mode) |
Yes |
No |
|
|
|
Miscellaneous |
|
|
|
|
|
6.312-MHz clock (in J-SDH mode) |
Yes |
Yes |
|
|
|
Alarm provisioning |
Yes |
Yes |
|
|
|
Composite clock timing (in J-SDH mode) |
Yes |
Yes |
|
|
|
Consolidated load |
Yes |
Yes |
|
|
|
DS1 ESF BITS synchronization status messaging |
Yes |
Yes |
|
|
|
DS1 automatic in-service (AINS) |
Yes |
Yes |
|
|
|
DS1 loopback |
Yes |
No |
|
|
|
DS3 automatic in-service (AINS) on T3 facilities |
Yes |
Yes |
|
|
|
DS3 loopback |
Yes |
Yes |
|
|
|
DS3/VT automatic in-service (AINS) on T3 facilities |
Yes |
No |
|
|
|
External building-integrated timing supply (BITS) input/output |
Yes |
Yes |
|
|
|
Full TARP |
Yes |
Yes |
|
|
|
Hitless timing reference switching |
Yes |
Yes |
|
|
|
Independent synchronization and bandwidth management |
Yes |
Yes |
switching |
|
|
|
|
|
Mixed tributaries |
Yes |
Yes |
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-14 Overview
Table 1-1 (continued)
Feature compatibility for Release 12.1
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
NP/SP version checking |
Yes |
Yes |
|
|
|
OC-3 1+1 high speed exerciser |
Yes |
Yes |
|
|
|
OC-12 1+1 high-speed exerciser |
Yes |
Yes |
|
|
|
OC-48 1+1 high-speed exerciser |
Yes |
Yes |
|
|
|
OC-192 1+1 high-speed exerciser |
No |
Yes |
|
|
|
Optical Facility loopbacks for OC-3, OC-12, EC1x12, OC-3x4, |
Yes |
Yes |
STM-1x4, OC-12x4 STS, OC-48, OC-48 STS, OC-192, |
except OC-192 |
|
2xGigE/FC-P2P |
|
|
|
|
|
Optical Terminal loopbacks for OC-3, OC-12, EC1x12, |
Yes |
Yes |
OC-3x4, STM-1x4, OC-12x4 STS, OC-48, OC-48 STS, |
except OC-192 |
except OC-192 |
OC-192, 2xGigE/FC-P2P |
|
|
|
|
|
OSI 7 layer |
Yes |
Yes |
|
|
|
Path trace |
Yes |
Yes |
|
|
|
Site Manager Rel 6.0.1 |
Yes |
Yes |
See Note 8 |
|
|
|
|
|
Remote save and restore |
Yes |
Yes |
|
|
|
S1 byte synchronization status messaging |
Yes |
Yes |
|
|
|
Section trace |
Yes |
Yes |
|
|
|
Shelf timing (internal, line/loop, tributary, external) |
Yes |
Yes |
|
|
|
Stratum 3 internal clock |
Yes |
Yes |
|
|
|
SP spare management enhancements |
Yes |
Yes |
|
|
|
SSbit functionality at OC-3, OC-12, OC-48 and OC-192 rates |
Yes |
Yes |
|
except OC-192 |
|
|
|
|
STS-1 path trace for DS3, OC-3, OC-12, OC-48 and OC-192 |
Yes |
Yes |
|
except OC-192 |
See Note 9 |
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
|
|
Overview 1-15 |
|
|
|
Table 1-1 (continued) |
|
|
Feature compatibility for Release 12.1 |
|
|
|
|
|
Feature |
Supported on |
Supported on |
|
platforms with |
platforms with |
|
VTX-series |
STX circuit packs |
|
circuit packs |
|
|
|
|
Time of day synchronization |
Yes |
Yes |
|
|
|
VT1.5 group alarm |
Yes |
No |
|
|
|
Note 1: See Table 1-2 on page 1-16 for a list of optical circuit packs supported by each STX and VTX-series circuit packs.
Note 2: See Table 1-2 on page 1-16 for a list of optical circuit packs supported by each STX and VTX-series circuit packs.
Note 3: This is an out-of service procedure.
Note 4: The OPTera Metro 3500 Shelf assembly (NTN476AA) must be upgraded using power module and cooling upgrade kit (NTN458MW) to support OC-192 optical interfaces.
Note 5: This interface is below the hardware baseline for OPTera Metro Release 12.1 and it is not supported.
Note 6: DS1 PMs are available through DSM connected to OPTera Metro 3500 equipped with STX-192 circuit pack.
Note 7: Supported on all new Release 12.1 circuit packs (OC12x4 STS, OC-48 STS and OC-192) along with all OC-48 circuit packs and selected OC-12 circuit packs (NTN404JA, NTN404KA, NTN404LA, NTN404MA).
Note 8: Site Manager Release 6.0.1 is backward compatible to the following releases:
—OPTera Metro 3500 Releases 10.1, 10.3, 10.31, 11.01, 11.02, 12.0 and 12.1
—OPTera Metro 3300/3400 Releases 9.12, 11.11 and 11.12
—OPTera Metro 3100 Release 4.01 and 4.02
Note 9: For OPTera Metro 3500 equipped with STX-192 circuit packs (STS-managed), path trace must be monitored on the path terminating equipment such as DSM module, DS3, 2x100BTP2P, 2xGigGE/FC circuit packs.
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-16 Overview
For a list of supported electrical and optical interfaces by STX and VTX-series circuit packs in Release 12.1, see Table 1-2.
Table 1-2
Hardware Compatibility Matrix for Release 12.1
Card Type |
Supported on |
Supported on |
Notes |
|
platform with |
platforms with |
|
|
STX192 |
VTX-series |
|
|
circuit packs |
circuit packs |
|
|
|
|
|
OC-192 |
Yes |
No |
• Dual slot circuit packs |
|
|
|
supported in slots 11 |
|
|
|
and 12. |
|
|
|
• Supported only with |
|
|
|
STX-192 circuit pack. |
|
|
|
|
OC-48 STS |
Yes |
No |
• Single slot circuit packs |
|
|
|
supported in slots 3 to |
|
|
|
12. |
|
|
|
• Supported only with |
|
|
|
STX-192 circuit pack. |
|
|
|
|
OC-48 |
No |
Yes |
• Dual slot circuit packs |
|
|
|
supported in slots 11 |
|
|
|
and 12. |
|
|
|
• Supported only with |
|
|
|
VTX-series circuit pack. |
|
|
|
|
OC-12x4 STS |
Yes |
No |
• Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
• Supported with STX-192 |
|
|
|
circuit pack. |
|
|
|
|
OC-12 |
Yes |
Yes |
• Single slot circuit packs |
|
|
|
not supported in slots 11 |
|
|
|
and 12 with STX-192 or |
|
|
|
VTX-48 circuit packs. |
|
|
|
• Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 10 with STX-192 |
|
|
|
or VTX-48 circuit packs. |
|
|
|
• Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 12 with VTX-48e |
|
|
|
circuit pack. |
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
Overview 1-17
Table 1-2 (continued)
Hardware Compatibility Matrix for Release 12.1
Card Type |
Supported on |
Supported on |
Notes |
|
platform with |
platforms with |
|
|
STX192 |
VTX-series |
|
|
circuit packs |
circuit packs |
|
|
|
|
|
OC-3x4 |
Yes |
Yes |
Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
OC-3 |
Yes |
Yes |
• Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
STM-1x4 |
Yes |
Yes |
• Single slot circuit packs |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
2xGigE/FC-P2P |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
• Maximum bandwidth of |
|
|
|
12xSTS1 per card when |
|
|
|
equipped with |
|
|
|
VTX-series circuit packs. |
|
|
|
• Maximum bandwidth of |
|
|
|
2xSTS24 per card when |
|
|
|
equipped with STX-192 |
|
|
|
circuit packs. |
|
|
|
|
2xGigE (OPE) |
Yes |
Yes |
• Dual slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
• Maximum bandwidth |
|
|
|
assignable to a RPR is |
|
|
|
STS12c with both |
|
|
|
VTX-series and |
|
|
|
STX-192 circuit packs. |
|
|
|
|
4x100FX (OPE) |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
• Maximum bandwidth |
|
|
|
assignable to a RPR is |
|
|
|
STS12c with both |
|
|
|
VTX-series and |
|
|
|
STX-192 circuit packs. |
|
|
|
|
Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004
1-18 Overview
Table 1-2 (continued)
Hardware Compatibility Matrix for Release 12.1
Card Type |
Supported on |
Supported on |
Notes |
|
platform with |
platforms with |
|
|
STX192 |
VTX-series |
|
|
circuit packs |
circuit packs |
|
|
|
|
|
4x100BT(OPE) |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
• Maximum bandwidth |
|
|
|
assignable to a RPR is |
|
|
|
STS12c with both |
|
|
|
VTX-series and |
|
|
|
STX-192 circuit packs. |
|
|
|
|
2x100BT-P2P |
Yes |
Yes |
• Single slot circuit pack |
(Private Lines) |
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
EC-1x12 |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
DS3x12 |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
EC-1x3 |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
DS3VTx12 |
No |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
DS3x3 |
Yes |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
12xDS1 |
No |
Yes |
• Single slot circuit pack |
|
|
|
supported in slots 3 |
|
|
|
through 10. |
|
|
|
|
84xDS1 (DSM) |
Yes |
Yes |
• Support for 12 DSM per |
|
|
|
shelf. |
|
|
|
• DSM is only STS-1 |
|
|
|
managed with STX-192. |
|
|
|
|
OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004