National Instruments NI 9426 User Manual

0 (0)
National Instruments NI 9426 User Manual

OPERATING INSTRUCTIONS AND SPECIFICATIONS

NI 9426

32-Channel, 24 V, Sourcing Digital Input Module

Français Deutsch

ni.com/manuals

This document describes how to use the National Instruments 9426 and includes specifications and pin assignments for the NI 9426. Visit ni.com/info and enter rdsoftwareversion to determine which software you need for the modules you are using. For information about installing, configuring, and programming the system, refer to the system documentation. Visit ni.com/info and enter cseriesdoc for information about C Series documentation.

Note The safety guidelines and specifications in this document are specific to the NI 9426. The other components in the system might not meet the same safety ratings and specifications. Refer to the documentation for each component in the system to determine the safety ratings and specifications for the entire system.

Safety Guidelines

Operate the NI 9426 only as described in these operating instructions.

Hot Surface This icon denotes that the component may be hot. Touching this component may result in bodily injury.

NI 9426 Operating Instructions and Specifications

2

ni.com

Safety Guidelines for Hazardous Voltages

If hazardous voltages are connected to the module, take the following precautions. A hazardous voltage is a voltage greater than 42.4 Vpk or 60 VDC to earth ground.

Caution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards.

Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module.

Caution Make sure that devices and circuits connected to the module are properly insulated from human contact.

Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are properly insulated from human contact.

Safety Guidelines for Hazardous Locations

The NI 9426 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4, and

© National Instruments Corp.

3

NI 9426 Operating Instructions and Specifications

Ex nA IIC T4 hazardous locations; and nonhazardous locations only. Follow these guidelines if you are installing the NI 9426 in a potentially explosive environment. Not following these guidelines may result in serious injury or death.

Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous.

Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous.

Caution Substitution of components may impair suitability for Class I, Division 2.

Caution For Zone 2 applications, install the system in an enclosure rated to at least IP 54 as defined by IEC 60529 and EN 60529.

Caution For Zone 2 applications, install a protection device that prevents the Vsup voltage from exceeding 42 V if there is a transient overvoltage condition.

NI 9426 Operating Instructions and Specifications

4

ni.com

Special Conditions for Hazardous Locations Use in Europe

This equipment has been evaluated as Ex nA IIC T4 equipment under DEMKO Certificate No. 07 ATEX 0626664X. Each module is marked II 3G and is suitable for use in Zone 2 hazardous locations. If you are using the NI 9426 in Gas Group IIC hazardous locations or in ambient temperatures of –40 °C ≤ Ta ≤ 70 °C, you must use the device in an NI chassis that has been evaluated as EEx nC IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.

Special Conditions for Marine Applications

Some modules are Lloyd’s Register (LR) Type Approved for marine applications. To verify Lloyd’s Register certification, visit ni.com/certification and search for the LR certificate, or look for the Lloyd’s Register mark on the module.

Caution To meet radio frequency emission requirements for marine applications, use shielded cables and install the system in a metal enclosure. Suppression ferrites must be installed on power supply inputs near power entries to modules and controllers. Power supply and module cables must be separated on opposite sides of the enclosure and must enter and exit through opposing enclosure walls.

© National Instruments Corp.

5

NI 9426 Operating Instructions and Specifications

Connecting the NI 9426

The NI 9426 has a 37-pin DSUB connector that provides connections for 32 simultaneously-sampled digital input channels.

DI16

20

1

DI0

2

DI1

DI17

21

3

DI2

DI18

22

4

DI3

DI19

23

5

DI4

DI20

24

6

DI5

DI21

25

7

DI6

DI22

26

8

DI7

DI23

27

9

Vsup

Vsup

28

10

Vsup

Vsup

29

11

DI8

DI24

30

12

DI9

DI25

31

13

DI10

DI26

32

14

DI11

DI27

33

15

DI12

DI28

34

16

DI13

DI29

35

17

DI14

DI30

36

18

DI15

DI31

37

19

NC

 

 

 

Figure 1. NI 9426 Pin Assignments

NI 9426 Operating Instructions and Specifications

6

ni.com