Moen T473, T666, 72700, TL470, L2700 User Manual

...
0 (0)
Moen T473, T666, 72700, TL470, L2700 User Manual

MODELS 2600, 2700, 5401, 62600, 62700, 72615, 72700 and MODEL SERIES T471,

MT662C

T473, T555, T666, T777, T888, TL470, TL471, TL473, L2600, L2700

 

®

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE

LEFT WITH HOMEOWNER

TUB AND SHOWER VALVES

Available with three or four port castings, with and without stops.

Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.

If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.

Measurements

These are shown in the drawings. The depth measurement is critical.

Use the front face of the plaster ground as a reference point for the finished wall position, including tile (2-1/16" [52mm]). The center line of the supply and discharge piping should be a maximum of 2-3/16" (56mm) and a minimum of 1-7/16" (37mm) behind the finished wall surface.

IMPORTANT: SEE FLUSHING INSTRUCTIONS PAGE 2

A

B

C

 

TUB/SHOWER

 

FLANGE

FINISHED WALL

TUB FILLER

 

COMBINATION

 

 

LINE

 

OR SHOWER

 

 

SHOWERHEAD

 

 

 

 

 

 

 

SHOWER

 

 

 

 

 

 

ARM

2-1/16"

 

2-1/16"

HANDLE

HANDLE

 

 

 

 

 

(52mm)

 

(52mm)

COVER

KNOB

WASHER

PLASTER

 

6' 6"

 

 

 

 

GROUND

1-1/4"

 

 

 

 

 

(1981mm)

 

 

 

 

ESCUTCHEON

(32mm)

 

 

 

 

HANDLE

 

 

SUPPLY

HANDLE

 

SUPPLY

 

SCREW

LEVER

 

 

 

 

 

 

 

15/16"

 

STOP TUBE

 

 

(24mm)

 

 

32"

 

 

 

 

 

HANDLE LEVER

HANDLE SCREW HEXAGONAL

 

(813mm)

45"

 

 

 

(1143mm)

 

WRENCH

 

 

48"

 

 

 

 

 

 

 

CAUTION

(1219mm)

 

WASHER

 

 

 

 

USE 1/2"

 

SET SCREW

STOP TUBE

 

IRON PIPE

 

 

SIZE

 

HANDLE ADAPTER &

FLOOR

MINIMUM

 

BRAKE ASSEMBLY

OR 1/2"

 

 

 

 

 

 

TUBING.

 

Always turn water off before installing or disassembling the valve. Open CAUTION: valve handle to relieve water pressure and to insure that complete water

shut-off has been accomplished.

Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place. The cartridge and retainer clip were properly installed and tested before leaving the factory. Although it is unlikely, it is nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be properly installed. This should be carefully checked at time of rough-in and trim-out. If the retainer clip is not properly installed, water pressure could force the cartridge out of the casting. Personal injury or water damage to the premises could result.

CLIP

EAR

Stop Operation

WITHOUT STOPS

WITH STOPS

CC - This type is integral with casting, actuated by screwdriver, and require a 90° turn to open or close. When the screwdriver slot is vertical, the rubber stop is closed, and when the slot is horizontal, the rubber stop is open.

7" DIA

(178mm)

 

SHOWER

 

 

7" DIA

(178mm)

 

SHOWER

 

 

IPS - This type has been added to the basic shower casting and is actuated by screwdriver. The stop is opened by rotating in a counterclockwise direction until it stops and closed by rotating in a clockwise direction until it bottoms.

SUPPLY

TUB

SUPPLY

SUPPLY

RUBBER STOP VALVE (WITH SCREW DRIVER SLOT)

TUB

SUPPLY

‰ ‰

 

 

2" CC

 

(51mm)

Rough-In

2-3/16" IPS

 

 

 

(56mm)

MAKE SURE ALL WATER SUPPLIES ARE OFF.

4- port: (2700 SERIES): Install casting with "UP" at the top (arrow pointing up). If the valve is to be used for both a shower and a tub, connect the top outlet to the shower (36" minimum riser) and the bottom outlet to the tub (6" minimum drop), using 1/2" iron pipe size or 1/2" copper water tube, 5/8" O.D. (If the valve is to be used for a shower only or a tub only, plug the outlet not being used.)

3-port (2600 SERIES): These models may be used as either a shower or a tub filler. Since they are factory set in the shower position, with the outlet up, you must reverse the position of the cartridge retainer clip when using the valve as a tub filler. Accomplish this change during the assembly process. Remove the stop tube, pull the clip out from the bottom of the casting, rotate cartridge stem 180° and replace clip in the top, then proceed with assembly, using 1/2" iron pipe size or 1/2" copper water tube.

WARNING: Secure all pipes and the shower and tub drop ells. Use thread seal tape on all threads. Use a plain ell on the tub drop. A twin ell is not needed. CHECK SYSTEM FOR LEAKS BEFORE CLOSING WALL.

Install Shower Arm & Tub Spout

MAKE SURE ALL WATER SUPPLIES ARE OFF.

 

 

 

2-1/8" CC

4-1/2"

 

(54MM)

 

(114mm)

 

 

PLASTER GROUND

 

 

3-3/4" IPS

 

SIZE AND WALL

 

 

 

(95MM)

 

 

 

 

 

 

OPENING

4-5/8" FOR C.C.

 

 

(117mm)

 

 

 

6" FOR I.P.S.

 

 

 

 

 

(152mm)

 

 

CAUTION

These valves are equipped with Moen's long-life 1225 cartridge, designed for smooth, trouble free operation. When soldering, do not heat valve any higher than necessary to flow the solder. Overheating may damage the cartridge or rubber stop valves. Following this direction will allow you to solder without removing the cartridge or rubber stop valves.

WARNING: The cartridge and rubber stop valves MUST be removed before either brazing or resistance (electric) soldering. For stop valve removal instructions, see last page.

SHOWER: Install flange on long end of arm. Wrap threads on both ends of shower arm with thread seal tape.

Screw long end of shower arm into wall. Do not install showerhead prior to flushing (see Flushing).

C.C. SPOUT: The Moen Slip Fit spout is designed with an O-ring seal. It is specifically designed for installation with copper water tube. Lookout must

be free from burrs inside and out. The edge must not be rolled inward from a dull tubing cutter. The outside surface must be free from nicks and scratches.

Press and twist the spout onto the lookout upside down. Tighten the clamp screw with a 5/32" hex wrench until it just starts to bind. Turn spout upright into position against the wall and finish tightening the clamp screw by hand. The use of pliers or another wrench on the hex wrench is not necessary.

Do not overtighten.

IPS SPOUT:

C.C.

 

 

 

I.P.S.

CAUTION: This spout is A.B.S. plastic and will crack when in contact with some pipe thread compounds.

 

 

 

CLAMP SCREW

Please read the pipe compound label to be certain. We recommend using thread seal tape thread sealant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screw tub spout onto pipe and tighten by hand. If final turn by wrench is needed, use small wrench with smooth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jaws; otherwise, pad wrench teeth with rag. Pull outward on spout while tightening to avoid scratching the wall.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT INSERT TOOL INTO SPOUT END TO TURN SPOUT.

 

 

 

 

 

 

 

 

 

 

 

 

Flushing

IMPORTANT: Before closing all wall openings, pressure test valve and complete system using flushing instructions

IMPORTANT:

Pipe chips, sand, stones, and other solids found in new or renovated plumbing can damage the sealing surface of the cartridge and cause a leak. To avoid damage, DO NOT TURN ON SUPPLY VALVES until instructed below:

1.Break off the protective cap on the plaster ground at the top end of the stop tube cover (see illustration page 3). Place a flat bladed screwdriver into one of the slots near a support tab and twist to break. Repeat at remaining tabs.

2.Use pliers to operate cartridge.

3.Open the cartridge in the full cold position (notched flat pointing to the right) and turn on the cold supply for 15 seconds. Without closing the cartridge, turn to the full hot position (notched flat pointing to the left) and turn on the hot supply for 15 seconds.

4.Turn the cartridge to the mixed position (notched flat pointing up), divert water to the shower and run for an additional 15 seconds.

5.Close cartridge.

6.Install showerhead.

MT662C

Loading...
+ 2 hidden pages