LST BC216-1S User Manual

Size:
161.76 Kb
Download

FireDetectionControlPanel

BC216–1S

1-loopversion ofBC216-1

For the application in small systems

Analogue ringbus technology with unshielded detector cabling

Menu-drivenoperation

Easy commissioning through AUTO setup

32–bitmultiprocessor system

EN 54/VdS-certified

Fire is a permanent threat to life and property. Therefore, immediate response to a fire is imperative. The main objective of fire detection control panel Series BC216 is to alarm and to react in time and, consequently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a 32-bitmultiprocessor system, the fire detection control panel Series BC216 ensures topmost efficiency and speed – prerequisites for saving lives and minimizing damage to property.

Description

The fire detection control panel BC216–1Sis designed to be used in small systems with only one ADM loop. It comprises an already completely mounted unit which includes all basic components that are needed for the operation of a1-loopfire detection control panel.

Slot 1 is by default equipped with a Loop Interface LIF64-1for the connection of an ADM loop, slot 2 is inoperable.

The ADM loop principle offers intelligent analogue ringbus technology with bi-directionaldata transfer. The loop provides for thesoftware-aidedadministration of up to 198 physical address points in a maximum of 128 detector zones. Conventional detectors can be integra-

ted into the ADM loop, if required, by means of conventional zone modules.

Depending on the respective system, a Fire Brigade In- terfaceFWI2-1,aFireBrigadeInterfaceAdditionalBoardFWZ2-1,anLED-DisplayField LAB48 as well as further optional componentries can be installed in addition.

Easy parameterisation on the control panel‘s display and operating unit, via a PC keyboard, or by means of a PC software enables you to tailor the control panel to your individual requirements.

Building Safety. Building Security.

A

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231WIEN • WIEGELESTRASSE 36 • TEL +43 152114-0• FAX +43 152114-27

BC216-1S_DBL_LST_EN_0804.PDF• PAGE 1

OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED

 

Clear Concept

Being the smallest version of the fire detection control panel Series BC216, the BC216-1Sis designed for use in small systems and provides the following features:

One Loop Interface LIF64-1for the connection of detectors and modules in ADM loop technology is installed in the control panel by default. Depending on the parameterisation, either the Apollo/Discovery protocol or the System Sensor/200 protocol is used to achievebi-directionaldata transfer.

The optional Fire Brigade Interface FWI2-1serves for the connection of 2 independent transmitting devices for a direct interconnection to a designated alarm respondent (e.g., the fire brigade) as well as for the connection of acountry–specificfire brigade control unit. By using the Fire Brigade Interface Additional BoardFWZ2-1,a line supervision for both of the transmitting devices is accomplished.

The BC216-1Sis able to control up to 126 detectors or modules, 128 detector zones, 128 actuations, 10 transmission devices and 99 alarming devices.

Customizable outputs and logical combinations of detectors and detector zones for the activation of external controls and alarming devices facilitate maximum fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parameterisation possibilities, individual requirements even under the most difficult ambient conditions can be combined into a reasonable fire protection strategy.

By integrating input and output modules on any position in the loop you can realize enablements or disablements as well as control tasks in your system without having to care for additional wires.

The free combination of detectors and modules into logic sectors allows for the joint operation of defined parts of the system. Up to 199 sectors can be controlled by the BC216-1S.

The use of unshielded loop cables allows for costsaving and uncomplicated installation as well as for the possibility of reusing the existing cabling.

The LC text display shows events with the full information such as fl oor, room identification as well as date and time. This allows for quick and targeted reaction in the event of a fire as well as for easy maintenance.

An event memory allows for the display of the latest 500 events at any time, including all required information. Thus, all system conditions and user operations that occurred are documented in a clearly laid out

Building Safety. Building Security.

way.

At a central processing board failure, the diversified redundancy concept ensures secure alarm recognition.

The processor-monitoredpower supply ensures permanent surveillance and charging of the batteries. This way, even during a power failure the untroubled and uninterrupted operation (for more than 72 hours depending on the design) is guaranteed.

Three hierarchized authorization levels for operation and parameterisation facilitate a high degree of security against unauthorized access.

The control panel is easily operated menu-drivenvia the display and operating field. Clear instructions on the display guide the user during commissioning, operation and maintenance.

The parameter data can be entered either on the control panel via the display and operating field or via a PC keyboard or, in a more comfortable way, can be created on a PC by means of the parameter setup software PARSOFT and loaded into the control panel. Thus, a quick and efficient transfer of the system configuration into the control panel is guaranteed.

AUTO setup facilitates parameterisation when the control panel is commissioned or expanded and thus helps to save time.

After commissioning, the panel‘s basic functions immediately make it ready for operation. A monitored siren output and dry relay contacts for alarm and fault are available by default.

The fl at wall mount cabinet allows for an easy mounting in virtually any place of the building. Thanks to its modern, ageless design, architectural requirements and demands of the respective regulations are ideally combined. The compact design allows for the accommodation of the Loop Interface, the auxiliary modules and batteries up to 22Ah apart from the central processing board in the standard case. If a higher battery capacity is needed, an auxiliary case of the same design is available.

This product complies with all relevant standards of EN 54 and is VdS-certified.In addition, the product also holds severalcountry-specificapprovals and certificates. LST‘s high quality level is secured by a permanently monitored quality management system certified by ISO 9001.

A

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231WIEN • WIEGELESTRASSE 36 • TEL +43 152114-0• FAX +43 152114-27

BC216-1S_DBL_LST_EN_0804.PDF• PAGE 2

OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED

 

Permanent Connection

A variety of peripheral devices can be connected to the fire detection control panel BC216-1S:

• Fire brigade key safe

• Actuations

• Fire brigade control unit

• Modules for remote parameterisation and remote

• Acoustic and optical signaling devices

maintenance via computer newtork, modem or GSM

• External protocol printer

connection

• Remote indication unit

– and much more.

Specifi cations

Mains voltage

230VAC +10/-15%,50Hz

Connection power

60VA

Output voltage

typ. 28VDC

Output peak current

max. 1.8A

Connection of external devices

typ. 0.8A, site-specific

Own current consumption at 24V

typ. 115mA (incl. LIF64-1,without detectors/modules)

Ambient temperature

-5°Cto +50°C

Dimensions W × H × D

420 × 520 × 120 (mm)

Colour

gray-white,RAL 9002

Weight without accumulator

approx. 6kg

Approvals (EN 54-2,EN54-4)

VdS G201017

 

FT 14/147/3/99 (Austria),

Order name

Fire detection control panel BC216-1S

Building Safety. Building Security.