WARNING

To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing.

ALL electrical connections MUST be made by a qualified individual.

INSTALLATION

RED/GREEN LIGHT

CONTROL KIT

FOR USE WITH APT, T, GT, AND LOGIC OPERATORS MODEL RDGRNCARD

Step 3

MOUNT THE LIGHT BOX

Step 1

Step 2

STEP 1:

 

 

 

Attach mounting bracket to the electrical box with the self-threadingscrews (2) provided.

STEP 2:

Remove light box cover. Fasten light box to mounting bracket with self-threadingscrews (2) provided.

STEP 3:

Attach flex conduit to electrical box.

STEP 4:

Insert Red/Green Light Control Module into either of the two

slots located on the logic board (see step 4 illustration).

Step 4

NOTE: To avoid damage to relays, do not exceed the following:

Red light output - 75W, 120V incandescent bulb or 3A, 250VAC (Resistive load).

Green light output - 75W, 120V incandescent bulb or 3A, 250VAC (Resistive load).

Red/Green

Light Control

Module

Logic Board

Side View

Electrical Box

1

STEP 5: (FIGURE1)

Complete wiring connections as follows:

Connect red wire to red light terminal on the Red/Green Light

Control Module connector.

Connect black wire to green light terminal on the Red/Green

Light Control Module connector.

Connect white wire to L1 (NEUTRAL) on the power terminal strip.

Connect black jumper from L2 (HOT) on the power terminal strip to (120V IN) terminal on the Red/Green Light Control

Module connector.

Figure 1

Light Box

Light

 

Box

Red

 

Red

 

White

White

Black

Black

 

Cable

 

Green

Red

Light

Light

STEP 6:

Install red and green lightbulbs (not provided). Maximum wattage should not exceed 75 watts.

Green Lights

 

 

 

 

 

 

 

 

 

 

D4

RED

 

D3

 

 

WARNING DEVICES MODULE

.LT

1

 

 

 

 

 

 

 

R4

 

+24VDC

OUT

+5V +24V

 

 

R7

D2

 

 

 

 

 

 

 

 

TB2

 

 

K2

 

 

 

Q2

TB1

 

 

 

 

 

 

 

 

 

 

 

 

120V

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

IN

 

 

 

 

 

 

 

 

 

R2

 

 

 

 

 

 

 

 

 

 

 

 

Q1 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.LT

GREEN

3

 

 

K1

 

R8

D1

R3

C1

Q3

LOAD

 

 

 

 

 

R1

 

 

 

 

 

 

 

 

 

 

 

R6

 

 

 

 

 

 

 

R8

R9

 

 

 

 

R5

 

 

 

 

 

13

+

 

J1

 

C2

 

 

4

1

 

 

 

 

10

 

8

 

 

 

 

 

 

 

 

 

 

 

 

24 VOLT DC

Terminals

L1 L2

OPTIONAL MID-STOPPROGRAMMING:

LOGIC 3

To Program open or down (close) Mid-Stop:

1.Open the door to set close Mid-Stopor close door to set openMid-Stop.

2.Turn selector dial to “PROGRAM.”

3.Press the “MID SET” button on logic board.

4.Press the OPEN button for open Mid-Stop,wait until the door reaches the desiredMid-Stopheight, then press the STOP button.

OR

Press the CLOSE button for down Mid-Stop,wait until the door reaches the desiredMid-Stopheight, then press the

STOP button.

5.Press the MID SET button to complete programming.

6.Turn selector dial back to desired wiring type.

 

ON

 

 

 

LOGIC 2

SET

 

 

 

MID-STOP

 

 

 

To Program open Mid-Stop:

1

2

3

4

1. Close the door.

OFF

 

 

 

 

 

 

 

2.Set dip switches to "Set Mid-Stop".

3.Press open (the door will begin moving).

4.Press stop when the desired Mid-Stopheight is reached.

5.Return the dip switches to the desired wiring type (C2, B2, etc.). The door will now stop at this height every time the door is opened.

2

LIGHT CONTROL MODULE OPERATION

The green lights on the option board will turn on if the board is seated properly and the power is on. When the door reaches the full open position or programmed mid-stop,the timer circuit will be activated. The green lampholder will receive power. If the timer has not been set, the red lampholder will receive power when the door starts to close and until close limit is activated. If the timer has been set, the red lampholder will receive power as indicated by the chart below.

NOTE: The green lamp holder will never receive power if the timer is set to ten seconds or less. The red lamp holder will blink for one second on and one second off whenever the door is moving, even if the timer to close has not been programmed.

TIMER SETTING

RED LAMPHOLDER RECEIVES

 

POWER

 

 

Greater than or equal

10 seconds before door starts to

to 10 seconds

close and until close limit is

 

activated.

 

 

Less than 10 seconds

Immediately after reaching open

 

limit or mid-stop

 

 

Wiring Mode

Up Mid-Stop

Down Mid-Stop

 

 

 

B2, C2, E2

Stop movement, wait for user input:

Down Mid-Stopdisabled

 

3-ButtonControl Station will OPEN or

 

 

CLOSE on command Single Button

 

 

Control/Radio will OPEN on command.

 

 

 

 

D1

Up Mid-Stopdisabled

Down Mid-Stopdisabled

 

 

 

T, TS, FSTS

Stop movement, wait for user input:

Stop movement, then count down timer to close timer & auto close

 

3-ButtonControl Station will OPEN or

OR

 

CLOSE on command Single Button

User input during timer to close countdown:

 

Control/Radio will OPEN on command. If

3-ButtonControl Station will OPEN the door, CLOSE the door, or

 

timer to close set is set for up Mid-Stop,

STOP the countdown

 

timer to close will close the door.

Single Button Control will CLOSE on command

 

 

Radio will OPEN on command

 

 

Red/Green enabled at Mid-Stop

 

 

 

Failsafe B2, Failsafe C2

Stop movement, wait for user input:

Down Mid-Stopdisabled

 

3-ButtonControl Station will OPEN or

 

 

CLOSE on command

 

 

Single Button Control/Radio will OPEN

 

 

open command

 

 

 

 

Failsafe D1

Up Mid-Stopdisabled

Down Mid-Stopdisabled

 

 

 

Failsafe E2

Stop movement, wait for user input:

Down Mid-Stopdisabled

 

3-ButtonControl Station will OPEN or

 

 

CLOSE on command

 

 

 

 

3

 

©2006, The Chamberlain Group, Inc.

01-31098C