® Ice Maker
PRODUCT MODEL NUMBERS
KUIA18NNJ KUIS18NNJ
KUIA18PNL KUIS18PNJ
KUIC18NNS KUIV18NNM
Electrical: 115-volt, 60-Hz, AC-only, 15-amp grounded circuit is required. A time-delay fuse or circuit breaker and separate circuit is recommended.
Water: A cold water supply using 1/4 in. (0.64 cm) O.D. soft copper tubing with shutoff valve.
Drain: Either a gravity-drain system or condensate pump to carry water to an existing drain.
CABINET OPENING DIMENSIONS
1. Recommended location for electrical and plumbing fixtures.
2. Floor level
|
|
|
|
|
|
|
|
|
141/2 |
" |
|
|
|
A |
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
(36.8 cm) |
|
|
|||||||
34" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(86.4 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Min. |
|
|
|
|
|
|
|
|
|
|
|
|
|
281/2" |
|
341/2" |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
(87.6 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(72.4 cm) |
Max. |
|
|
|
|
3 1/2 " |
9" |
|
|
|
|
|
||||
|
|
|
|
(8.9 cm) (22.9 cm) |
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B
24" (60.1 cm)
18" |
|
|
|
|
(45.7 cm) |
|
|
|
|
DRAIN REQUIREMENTS |
|
|
|
|
|
|
|
|
Drain lines must have a minimum of 5⁄8 in. |
|
|
|
|
(15.88 mm) inside diameter. |
A. Water Pan |
|
|
|
Drain lines must have a 1 in. drop per 48 in. (2.54 cm |
|
|
|
drop per 122 cm) of run or 1⁄4 in. drop per 12 in. |
|
Drain |
|
|
|
|
|
|
|
(6.35 mm per 30.48 cm) and must not have low |
|
B. Water Valve |
|
|
|
|
|
|
|
points where water can settle. |
|
|
|
|
A |
The floor drains must be large enough to |
15¹⁄ " |
|
|
|
accommodate drainage from all drains. |
(38.7 cm) |
|
|
B |
The ideal installation has a standpipe with a 1-1⁄2 in. |
|
8¹³⁄ " |
|
||
A |
|
|
(3.81 cm) to 2 in. (5.08 cm) PVC drain reducer |
|
(22.4 cm) |
3 ⁄ " |
|
||
|
|
|
installed directly below the outlet of the drain tube as |
|
B |
|
(9.2 cm) |
1" (2.54 cm) |
|
|
|
shown. You must maintain a 1 in. (2.54 cm) air gap |
||
|
|
|
||
|
|
|
|
between the drain hose and the standpipe. |
|
|
23" |
C |
It may be desirable to insulate the drain line |
|
|
(58.4 cm) |
D |
thoroughly up to the drain inlet. |
5¹¹⁄ " |
2 ⁄ " |
|
||
(14.5 cm) |
|
2" - 1¹⁄ " |
A. Drain hose |
|
|
(7.27 cm) |
|
||
|
|
(5 cm - 3.8 cm) |
B. 1" (2.54 cm) air gap |
|
17¹³⁄ " |
|
|
|
|
|
|
|
C. PVC drain reducer |
|
(45.2 cm) |
|
|
|
|
|
|
|
D. Center of drain should be 23" (58.4 cm) from front of door, |
|
|
|
|
|
|
|
|
|
|
with or without the ³⁄" (1.91 cm) panel on the door. The |
|
|
|
|
drain should also be centered from left to right (8³⁄" |
|
|
|
|
[22.37 cm] from either side of the ice maker). |
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation |
Ref. 2313788 |
Instructions packed with product. Specifications subject to change without notice. |
08-23-06 |