Kingston Technology KND810TX User Manual

Size:
570.18 Kb
Download

KINGSTONTECHNOLOGY

FASTETHERXSTACKABLE

8-PORT,16-PORT,&24-PORT

10/100TX RACK-MOUNTABLE

DUAL SPEED HUB

USER’SGUIDE

MODELS: KND810TX KND1610TX KND2410TX

Kingston Technology

Fast EtheRx Stackable 8-Port,16-Port,&24-Port

10/100TX Rack-Mountable

Dual Speed Hubs

User’s Guide

Part No. 4460064-001.A01

Kingston Technology Company

17600 Newhope

Fountain Valley, CA 92708

(714) 435-2600

Important Safety Instructions

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

1.Read all these instructions.

2.Save these instructions for later use.

3.Follow all warnings and instructions marked on the product.

4.Do not use this product near water.

5.This product should be operated from the type of power source indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.

6.Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risk. Refer all servicing to service personnel.

Wichtige Sicherheitshinweise

1.Diese Hinweise sollten vollständig durchgelesen werden.

2.Diese Hinweise für einen späteren Gebrauch aufbewahren.

3.Allen auf dem Gerät angebrachten Warnungen und Hinweisen folgen.

4.Das Gerät nicht in der Nähe von Wasser verwenden.

5.Das Gerät nur mit dem Aufkleber bezeichneten Netzspannung betreiben. Bei Fragen über die Art der Netzspannung sollte der Händler oder das Energieversorgungsunternehmen zu rate gezogen werden.

6.Nicht versuchen das Produkt selbst zu reparieren. In allen Produkten existieren gefährliche elektrische

Spannugen. Nicht das Gehäuse öffnen.

Table Of Contents

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Introduction......................................................................................

 

 

1

Model Types......................................................................

 

 

1

Special Features ...............................................................

 

2

Package Contents .............................................................

 

2

Design Features ..............................................................................

 

 

3

Repeater Functions ...........................................................

 

3

Receive Jabber Protection ................................................

 

3

Collision-Handling .............................................................

 

3

Error-Handling...................................................................

 

3

Automatic Port Partitioning / Reconnection

.......................3

Hardware Installation .......................................................................

 

 

4

Front Panel........................................................................

 

 

4

Power LED..........................................................

 

4

Collision LEDs.....................................................

 

4

100TX (Speed-Detection)LEDs..........................

4

Link / Activity LEDs .............................................

 

4

10/100TX UTP Ports...........................................

 

5

Uplink Port ..........................................................

 

5

Rear Panel ........................................................................

 

 

6

Power Switch ......................................................

 

6

AC Power Connector ..........................................

 

6

Fuse

....................................................................

 

6

Fan Unit(s) ..........................................................

 

6

Stack-In /Stack-OutPorts

..................................

7

Speed-SettingDip Switches................................

8

Appendices......................................................................................

 

 

9

Appendix A

Pin Assignments .......................................

 

10

UTP Port Pin Assignments................................

10

Appendix B

Cabling Guidelines ....................................

 

11

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

UTP Cable Type ...............................................

11

UTP Cable Wiring .............................................

11

UTP Cable Wiring Standards............................

11

UTP Cable Rating Codes..................................

12

Appendix C Specifications............................................

13

Appendix D Commonly Asked Questions.....................

15

Appendix E Warranties and Notices.............................

16

Limited Warranty Statement .............................

17

Duration of Warranty.........................................

17

Free Technical Support.....................................

18

Disclaimers .......................................................

18

F.C.C. Certification............................................

19

CE Notice..........................................................

19

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Introduction

1

Introduction

Intended Audience: This manual assumes that the user has a general working knowledge of networking principles and is familiar with network systems in general.

Congratulations on the purchase of your Kingston Fast EtheRx Stackable 10/100TX Rack-MountableDual Speed hub. There are three models available:KND810TX (8-portmodel),KND1610TX (16-portmodel)KND2410TX (24-portmodel). The KND810TX and KND1610TX can be used on a desktop or standard 19”rack-mountinstallation, using the extended mounting brackets provided with the unit. The KND2410TX is a full 19”rack-mountunit. The Fast EtheRx Stackable 10/100TXDual-Speedhubs conform to IEEE802.3u100BASE-TX,IEEE802.3i10BASE-T,and IEEE802.3 CSMA/CD standards. Using any combination of thedual-speedhubs, you can stack up to a maximum of four hubs.

For ease of installation, the Fast EtheRx Stackable Dual Speed hubs offer eight (8), sixteen (16), or twenty-four(24) UTP ports thatauto-negotiate10/100Mbps operation and an uplink port that allows the last UTP port on the hub to support both crossover andstraight-throughcabling. By default port 7 & 8 (KND810TX & KND1610TX) or port 23 & 24 (KND2410TX) are set forauto-negotiationbut can be manually configured for either 10Mbps or 100Mbps operation, using the dip switches located on the back of the unit. Ideal forinter-connecting10BASE-TEthernet networks with100BASE-TXFast Ethernet networks, the Fast EtheRxDual-speedhubs can also be used as simple standalone10BASE-Tor100BASE-TXrepeaters. For easytrouble-shooting,the front panel includes a variety of diagnostic LEDs such as Power, Collision for 10Mbps and 100Mbps, 100TX, Link, and Activity status.

For the remainder of this manual, the Fast EtheRx Stackable 10/100TX Dual-Speedhubs will be referred to collectively as the Fast EtheRxDual-Speedhubs:

KND810TX - Fast EtheRx Stackable 8-portRack-mountabledual-speedhub KND1610TX - Fast EtheRx Stackable16-portRack-mountabledual-speedhub KND2410TX - Fast EtheRx Stackable24-portRack-mountabledual-speedhub

Model Types

1

2

3

4

5

6

7

8

9

10

11

12

 

13

14

15

16

17

18

19

20

21

22

23

24

24

Fig. 1-1– KND810TX, KND1610TX, & KND2410TX

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

2

Special Features

Special Features

Conforms to IEEE802.3u 100BASE-TX,IEEE802.3i10BASE-T,and IEEE802.3 CSMA/CD standards

Inter-connects10BASE-TEthernet networks with100BASE-TXFast Ethernet networks

Works as a simple 100BASE-TXor10BASE-Trepeater

10/100BASE-TXClassII compliant repeater

Stacking ports for stacking up to four (4) hubs maximum

8, 16, or 24 UTP ports that auto-negotiate10/100TX operation

Dip switches to manually configure the speed setting on ports 7 & 8 (or ports 23 & 24) for 10Mbps, 100Mbps, or auto-negotiation(default)

8, 16, or 24 100TX LEDs for 100Mbps speed detection

8, 16, or 24 Link / Activity status LEDs for easy troubleshooting

Individual collision LEDs for both 10Mbps and 100Mbps collision detection

1 Power LED for power status

Automatic port partitioning / reconnection

Uplink port that supports both crossover and straight-throughcable wiring

Internal auto-sensingpower supply operating at100-240VAC(50/60Hz)

Desktop or rack-mountable

Package Contents

The Fast EtheRx Dual-Speedpackage should contain the following items:

Fast EtheRx KND810TX,KND1610TX, orKND2410TX dual-speedhub50-pinshielded stacking cable

AC power cord Mounting kit includes:

(2) Angle brackets

(8) Mounting Bracket screws

(4) 10/32” Rack-Mountthumb screws

(4) Rubber feet

User’s Guide

If any of the items are missing or damaged, please contact your Kingston dealer for a replacement. Be sure the items you receive are genuine Kingston Technology products. If the Kingston name and logo are not on the front panel of the unit, it’s not a genuine Kingston product.

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Front Panel

3

Design Features

The Fast EtheRx dual-speedhub complies with the full set of repeater basic functions as defined by IEEE802.3u100BASE-TX,IEEE802.3i10BASE-T,and IEEE802.3 CSMA/CD standards.

Repeater Functions

If any single port senses the start of a valid packet on its receiving line, the dual-speedhub willre-transmitthe received data to all other ports on the network. There-transmissionof packets complies with the IEEE 802.3 specification in terms of preamble structure, voltage amplitude, and timing characteristics.

Auto-Negotiation

Auto-Negotiationprovides the means of automatically establishing a link by detecting the link capabilities of the connected device on the network to select the best operational mode available (i.e. 10/100Mbps selection)

Receive Jabber Protection

The dual-speedhub uses a Receive Jabber Protection scheme to ensure that the network is not disabled due to reception of excessively long data packets.

Collision-Handling

The dual-speedhub will detect and respond to collision conditions as outlined in the IEEE 802.3 specifications.

Error-Handling

With 100BASE-TXFast Ethernet, the newerror-handlingfeature prevents substandard links from generating streams of false carrier and interfering with other links.

Automatic Port Partitioning / Reconnection

If any of the ports on the dual-speedhub experience excessive collisions, or faulty conditions, that particular port can be partitioned. Once partitioned, the hub will continue to monitor that port. If the error conditions have been corrected or a good data packet is received or transmitted without a collision, the hub will automatically reconnect that port to the network.

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

4

Front Panel

Hardware Installation

Before you begin installing network cables, please take a few minutes to familiarize yourself with the dual-speedhub. See the diagram below:

Front Panel

100TX LEDs

Link / Activity LEDs

 

 

1

2

3

4

5

6

7

8

9

10

11

12

 

 

13

14

15

16

17

18

19

20

21

22

23

24

24

Power LED

Collision LEDs

 

 

10/100BASE - TX

 

 

 

 

Uplink Port

 

for 10 and 100

 

 

 

UTP Ports

 

 

 

 

 

 

 

Fig. 1-2KND2410TX Front Panel

 

 

Power LED

The green LED indicates the power status. The LED will light up when the AC power connector is properly connected to a power source.

Collision LEDs

There are two (2) separate collision LEDs for both 10Mbps and 100Mbps segments. If a collision is detected on a 10Mbps segment, the “10” LED will flash amber. If a collision is detected on a 100Mbps segment, the “100” LED will flash amber. Collisions occur when 2 or more ports receive data simultaneously

100TX (Speed-Detection)LEDs

The 100TX LED lights up when 100Mbps operation is detected. The 100TX LED will not light up if 10Mbps operation is detected.

Link / Activity LEDs

The LINK / ACTIVITY LEDs service both 10BASE-Tand100BASE-TXoperation. A steady green light indicates that a good link has been established. A flashing green light indicates that data is being received.

If the Link LED does not display a steady green link light, please check the following:

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Front Panel

5

1.Make sure the power is turned on for both the PC and EtheRx hub.

2.Verify that the correct network drivers have been loaded on the PC. Some network adapters require the drivers to be loaded to establish a proper link.

3.Make sure the correct cable type is selected.

4.Make sure the cable is wired properly and connected on both ends.

5.If steps 1 through 4 are correct, the cable may be defective or not wired correctly. Please refer to Appendix A for pin assignments and Appendix B for cabling guidelines.

10/100TX UTP Ports

The eight (8), sixteen (16), and twenty-four(24) 10/100TX UTP ports autonegotiate both10BASE-Tand100BASE-TXconnections. The speed settings for ports 7 & 8 (on the KND810TX & KND1610TX models) and ports 23 & 24 (on the KND2410TX model) can also be manually configured to operate at 10Mbps or 100Mbps using the dip switches located on the back of the unit (seeSpeed-Setting Dip Switches in the Rear Panel section). All ports like all normal hub ports are configured asMDI-X.However, port 8 (models KND810TX and KND1610TX) & Port 24 (model KND2410TX), support bothMDI-Xand MDI port configuration.

Uplink Port

The uplink port provides cabling flexibility on UTP port no. 8 (KND810TX & KND 1610TX models) and UTP port 24 (2410TX model) for connecting to a workstation NIC or cascading to another hub. Although these ports have two

(2) UTP connections, MDI and MDI-X,only one port may be used.

Notes on MDI and MDI-XPorts

MDI (Media Dependent Interface) is the standard that defines the mechanical and electrical configuration of a UTP port. For any two devices to communicate with each other, the transmitter of one device must be connected to the receiver of the other device.

 

Switch

 

 

Port

 

 

For Connection to

 

 

For Connection to a

 

 

Position

 

 

Config

 

 

another Hub Port (MDI-X)

 

 

Network Adapter (MDI)

 

 

 

 

 

 

 

MDI-X

 

 

Use Crossover cable

 

 

Use Straight-throughcable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDI

 

 

Use Straight-throughcable

 

Use Crossover cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

6 Rear Panel

Rear Panel

 

 

 

 

 

 

 

AC Power

Power Switch

 

 

 

 

 

 

 

Connector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U S E O N L Y W I T H A 2 5 0 V F U S E

Dip Switches

Stack-In /Stack-Out

Fan

Fuse (250V, 2A)

 

Ports

 

 

 

 

Fig. 1-3Rear Panel

Power Switch

The AC Power switch turns the unit ON or OFF. If the PWR LED does not light up once the unit has been turned on, try the procedures below (in the following order):

1.Try a different AC power outlet.

2.Check the external fuse located at the back of unit (below the AC power connector). If the fuse is blown, replace it with the spare fuse provided with the unit. (See Fuse Compartment display on page 8)

3.The power supply may be defective. Return the unit for replacement.

WARNING: For safety reasons, DO NOT attempt to open and service the unit. There are no user-serviceablecomponents inside.

AC Power Connector

The Fast EtheRx dual-speedhubs use100-240VACinternal power supplies. Connect the AC power cord from the back of the unit to an AC electrical outlet.

Fuse

The Fast EtheRx dual-speedhubs come equipped with one external fuse and one spare fuse. Both fuses are in a fuse holder located just below the AC power connector on the back of the unit. Both fuses are rated 250V/2A max.

Fan Unit(s)

The Fast EtheRx dual-speedhubs use independent cooling fans for optimum airflow to safeguard the unit from unnecessary heat exposure.

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Rear Panel

7

Stack-In /Stack-OutPorts

U S E O N L Y W I T H A 2 5 0 V F U S E

U S E O N L Y W I T H A 2 5 0 V F U S E

U S E O N L Y W I T H A 2 5 0 V F U S E

Fig. 1-4Stacking Configuration

The Fast EtheRx stackable hubs use stacking ports located on the back of the unit to stack up to a maximum of four hubs, using any combination of the KND810TX, KND1610TX, and KND2410TX models. Follow the directions below on stacking these hubs together:

1.Power down the Fast EtheRx hub(s).

2.Locate the 50-pinshielded stacking cable included with your package contents.

3.Plug one end of the cable into the port labeled, “Stack-Out” on the first hub.

4.Plug the other end of the cable into the “Stack-In” port on the second hub.

5.Repeat steps 2 through 4 for stacking up to a maximum of four (4) hubs.

Kingston’s Stack-n-Play feature offers greater scalabilty to add UTP ports without the need to configure ID or termination switches. When configured as a stack, the Fast EtheRx stackable hubs are recognized as a single unit on the network. By stacking hubs together, you can expand the total number of UTP ports up to 96 ports.

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

8

Rear Panel

Speed-SettingDip Switches

The dip switches located on the back of the unit can be used to manually configure ports 7 & 8 (KND810TX & KND1610TX) or port 23 & 24 (KND2410TX) to operate at 10Mbps, 100Mbps, or Auto-negotiation(default). Dip switches in the ‘UP’ position are set toOFF (default). Dip switches in the ‘DOWN’ position are set toON. For specific speed setting combinations, see Table1-2below.

D I P S W I T C H S E T T I N G S

 

 

 

PORT NO. 7 (or 23)

 

PORT NO. 8 (or 24)

 

 

SPEED SETTING

DIP SWITCH 1

DIP SWITCH 2

 

DIP SWITCH 3

DIP SWITCH 4

EXAMPLE

 

 

 

 

 

 

 

 

 

 

 

AUTO-NEGOTIATION

UP = OFF

UP = OFF

 

UP = OFF

UP = OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100MBPS

DOWN = ON

UP = OFF

 

DOWN = ON

UP = OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10MBPS

UP = OFF

DOWN = ON

 

UP = OFF

DOWN = ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1-2Dip Switch Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

Up = OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2 3 4

 

 

 

 

 

AUTO

Down = ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

8

 

 

 

 

 

 

 

100 Mbps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT NO.

 

 

 

10 Mbps

 

 

 

 

 

 

Fig. 1-5Dip Switch Configuration

(KND810TX & KND1610TX)

(NOTE: The Fast EtheRx stackable hubs come equipped with one external fuse and one spare fuse. Both fuses are in a fuse holder located just below the AC power connector on the back of the unit. Both fuses are rated 250V/2A maximum.)

Fuse (250V, 2A)

FUSE

A 250V

WITH

ONLY

USE

S p a r e

F u s e

Fig. 1-6Fuse(s) Compartment

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Appendices

9

Appendices

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

10

Appendix A Pin Assignments

Appendix A Pin Assignments

UTP Port Pin Assignments

UTP Ports use RJ-45Unshielded Twisted Pair (UTP) cabling.RJ-45modular plugs and their pin numbers and wiring assignments are listed below. TwistedPair cables can be wired with eitherStraight-Throughor Crossover pin assignments. Both wiring schemes are mentioned in"Appendix B Cabling Guidelines" for reference in creating atwisted-paircable.

11

12

23

24

24

1 2 3 4 5 6 7 8

Modular

Connector

Fig. A-1RJ-45Connector Pin Numbers

 

Pin Number

 

 

MDI-X /

 

 

MDI /

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

Receive Data +

 

 

Transmit Data +

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Receive Data -

 

 

Transmit Data -

 

 

 

 

 

 

 

 

 

 

 

3

 

 

Transmit Data +

 

 

Receive Data +

 

 

 

 

 

 

 

 

 

 

 

4,5

 

 

Not Used

 

 

Not Used

 

 

 

 

 

 

 

 

 

 

 

6

 

 

Transmit Data -

 

 

Receive Data -

 

 

 

 

 

 

 

 

 

 

 

7,8

 

 

Not Used

 

 

Not Used

 

 

 

 

 

 

 

 

 

 

 

 

Table A-1UTP Pin Assignments

(NOTE: For further details, refer to Notes on MDI & MDI-X on page 5)

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Appendix B Cabling Guidelines

11

Appendix B Cabling Guidelines

UTP Cable Type

When installing network cables, the following table shows appropriate cabling guidelines for 100BASE-TXFast Ethernet architecture.

 

Cabling Components:

 

 

100BASE-TX

 

 

 

 

 

 

 

 

Trunk and Patch Cable

 

 

4-Pair100Ω UTP CAT 5

 

 

Type:

 

 

(only 2 pairs used)

 

 

Modular Plug:

 

 

8-PinRJ-45CAT 5 only

 

 

 

 

 

 

 

 

Patch Panel:

 

 

8-PinRJ-45CAT 5 only

 

 

 

 

 

 

 

Table B-1Network Cable Guidelines

(NOTE: All UTP cables come in both solid and stranded filament. Solid filament cables are more rigid and usually intended for trunk cabling. Stranded filament cables are more pliable and generally targeted for patch cables. For proper termination, use the correctRJ-45connector, as they differ for each type of cable.)

UTP Cable Wiring

UTP cables are wired based on one of two standard pin configurations: Straight-Through andCross-Over.100BASE-TXuses onlyCategory-5UTP cables with four pairs of wire as illustrated below in TablesB-2andB-3.

 

 

 

 

"Straight-Through"

 

"Cross-Over”

 

 

 

 

 

 

 

Configuration

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin Number

 

 

Pin Number

 

 

 

Pin Number

 

 

Pin Number

 

 

 

 

 

1

(TRX+)

 

 

1

(TRX+)

 

 

 

1

(TRX+)

 

 

3

(RCV+)

 

 

 

2

(TRX-)

 

2

(TRX-)

 

 

2

(TRX-)

 

6

(RCV-)

 

 

3

(RCV+)

 

3

(RCV+)

 

 

3

(RCV+)

 

1

(TRX+)

 

 

6

(RCV-)

 

6

(RCV-)

 

 

6

(RCV-)

 

2

(TRX-)

 

 

4, 5, 7, 8

 

 

Not Used

 

 

4, 5, 7, 8

 

 

Not Used

 

 

Table B-2.Straight

-ThroughWiring

 

 

Table B-3.Cross-OverWiring

 

 

 

 

UTP Cable Wiring Standards

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KND2410TX User’s Guide - Rev. A01

 

Kingston Technology Company

 

12

Appendix B Cabling Guidelines

There are two governmental agencies: the Electronic Industry Association (EIA) and the Telecommunications Industry Association (TIA), which set the standard for all cable wiring requirements for commercial buildings.

With the advent of 100Mb/s networking products, it is best to use higher quality CAT 5 cables like Belden or Helix as well as CAT 5-compliantpatch panels, patch cables, and connectors while following the EIA/TIA wiring standards. 100UTP CAT 5 type cables use4-pairUTP wiring.

Refer to the illustrations below for 4-pairwiring using either T568A (Fig.B-1)or T568B (Fig.B-2)wiring standards. Both T568A and T568B wiring is compatible with10BASE-Tand100BASE-TXand require no special configurations, but for premise wiring, stick to one wiring standard. Mixing T568A and T568B wiring schemes may cause or lead to potential problems.

Fig. B-14-PairT568A Wiring

Fig. B-24-PairT568B Wiring

 

T568A

 

 

Pairs

 

 

Strand

 

 

Solid

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 1

 

 

Pair 3

 

 

Blue

 

White/Green

 

 

 

 

 

 

 

 

 

 

 

 

Pin 2

 

Pair 3

 

 

Orange

 

Green/White

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 3

 

Pair 2

 

 

Black

 

 

White/Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 4

 

 

Pair 1

 

 

Red

 

Blue/White

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 5

 

 

Pair 1

 

 

Green

 

White/Blue

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 6

 

 

Pair 2

 

 

Yellow

 

Orange/White

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 7

 

 

Pair 4

 

 

Brown

 

White/Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 8

 

 

Pair 4

 

 

White

 

 

Brown/White

 

 

 

 

 

 

 

 

 

 

 

 

 

Table. B-44-PairT568A Wiring

 

T568B

 

 

Pairs

 

 

Strand

 

 

Solid

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 1

 

Pair 2

 

 

Black

 

 

White/Orange

 

 

 

 

 

 

 

 

 

 

 

 

Pin 2

 

Pair 2

 

Yellow

 

 

Orange/White

 

 

 

 

 

 

 

 

 

 

 

 

Pin 3

 

Pair 3

 

 

Blue

 

White/Green

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 4

 

Pair 1

 

 

Red

 

 

Blue/White

 

 

 

 

 

 

 

 

 

 

 

Pin 5

 

Pair 1

 

Green

 

White/Blue

 

 

 

 

 

 

 

 

 

 

 

Pin 6

 

Pair 3

 

Orange

 

Green/White

 

 

 

 

 

 

 

 

 

 

 

 

Pin 7

 

Pair 4

 

Brown

 

 

White/Brown

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin 8

 

Pair 4

 

 

White

 

 

Brown/White

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B-54-PairT568B Wiring

UTP Cable Rating Codes

UTP cables meet different UL-NECrequirements based oncable-jacketquality. Below is an explanation of the rating codes for each cable type.

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01

Appendix B Cabling Guidelines

13

UL – The National Electrical Code (NEC), published by the National Fire Protection Association (NFPA), details advisory safety considerations for electrical wiring. NEC Article 800 Communications Cables are manufactured to meet these different cable types.

1.CMP – Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for fire resistance andlow-smokeproducing characteristics.

2.CMR – Riser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications.

3.CM – Cables for general building wiring. CM cables are used in areas other than plenums and risers. These cables are resistant to the spread of fire and pass the UL 1581Vertical Tray Flame Test.

4.MP, MPR &MPP – Within Article 800, theMulti-purposeCables Category allows conditional substitutions between different cable types & are restricted by number, AWG size and stranding of the cable conductors.

Terms You Should Be Familiar With

1.BACKBONE WIRING – The physical/electrical interconnections between telecommunications closets and equipment rooms.

2.COMPLIANCE – A wiring device that meets all characteristics of a standard is said to be in compliance with that standard.

3.PREMISE WIRING – The entire wiring system on the premises especially the supporting wiring that connects the communications outlets to the network interface jack.

4.NEAR-END CROSSTALK (NEXT) – In wires packed together within a cable, the signals generated at one end of the link can flush out the weaker signals coming back from the recipient.

Appendix C Specifications

Fast EtheRx KND810TX, KND1610TX, KND2410TX

KND2410TX User’s Guide - Rev. A01

Kingston Technology Company

14

 

 

 

Appendix C

Specifications

 

 

Compliance:

 

IEEE802.3u 100BASE-TXStandard

 

 

 

 

 

 

IEEE802.3i 10BASE-TStandard

 

 

 

 

 

 

IEEE802.3 CSMA/CD Standard

 

 

 

 

Media Interface:

 

 

 

 

 

 

 

 

 

KND810TX

 

8 auto-negotiating10/100TX UTP ports

 

 

 

 

KND1610TX

 

16 auto-negotiating10/100TX UTP ports

 

 

 

 

KND2410TX

 

24 auto-negotiating10/100TX UTP ports

 

 

 

 

Speed Setting Dip Switches:

KND810TX

 

KND1610TX

 

KND2410TX

 

 

[Used to manually

configure

Ports 7 & 8

 

Ports 7 & 8

 

Ports 23 & 24

 

 

the corresponding

ports for

 

 

 

 

 

 

 

 

10Mbps, 100Mbps, or Auto-

 

 

 

 

 

 

 

 

negotiation (default setting)].

 

 

 

 

 

 

 

 

Diagnostic LEDs:

 

1 LED for Power Indicator (steady green)

 

 

 

 

 

 

2 LEDs for both 10Mbps and 100Mbps collision detection (flashing amber)

 

 

 

 

8, 16, or 24 LEDs for 100TX speed detection (steady green)

 

 

 

 

8, 16, or 24 LEDs for Link (steady green) / Activity (flashing green)

 

 

Stacking Cable:

 

50-pinshielded cable

 

 

 

 

 

 

 

Additional stacking:

 

Up to a maximum of four (4) hubs

 

 

 

 

Uplink port:

 

KND810TX

 

KND1610TX

 

KND2410TX

 

 

 

 

Port 8

 

Port 8

 

Port 24

 

 

Connection Type:

 

RJ-45,Female

 

 

 

 

 

 

 

Cable Type:

 

UTP 26 to 22 AWG

 

 

 

 

 

 

 

Cable Grade:

 

 

 

 

 

 

 

 

 

10BASE-T

 

CAT3, 4, 5 or better

 

 

 

 

 

 

 

100BASE-TX

 

CAT5 or better

 

 

 

 

 

 

 

Max. Cable Length:

 

100m (328ft)

 

 

 

 

 

 

 

Repeater to node

 

 

 

 

 

 

 

 

Inter-repeaterlink

 

5m (16.4ft)

 

 

 

 

 

 

 

2 Class II Repeaters

 

 

 

 

 

 

 

Environmental:

 

 

 

 

 

 

 

 

 

Operating Temp.

 

0°C to 45°C (32°F to 113°F)

 

 

 

 

Storage Temp.

 

-20°Cto 60°C(-4°Fto 140°F)

 

 

 

 

Relative Humidity

 

10% to 90% non-condensing

 

 

 

 

Electrical:

 

 

 

 

 

 

 

 

 

Input Voltage:

 

100VAC-240VAC,50/60Hz,auto-sensinginternal power supply

 

 

Output DC Voltage:

 

 

 

 

 

 

 

 

 

KND810TX / KND1610TX:

5 Vdc / 6A

 

 

 

 

 

 

 

KND2410TX:

 

5 Vdc / 11A

 

 

 

 

 

 

 

Power Consumption:

 

KND810TX

 

KND1610TX

 

KND2410TX

 

 

 

11.05 Watts max.

19.40 Watts max.

 

30.00 Watts max.

 

 

 

 

 

 

 

External Fuse:

 

250V / 2A maximum

 

 

 

 

 

 

 

Physical:

 

 

 

 

 

 

 

 

 

Dimension (HxWxD):

 

 

 

 

 

 

 

 

KND810TX / KND1610TX:

1.70” x 10.45” x 6.3” (43.2mm x 265.5mm x 160mm)

 

 

 

 

KND2410TX:

 

1.70” x 17.32” x 7.88” (43.2mm x 440.4mm x 200mm)

 

 

 

 

Weight:

 

KND810TX

 

KND1610TX

 

KND2410TX

 

 

 

3.4 lbs. (1.55 kg)

 

3.8 lbs. (1.73 kg)

 

6.2 lbs. (2.81 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Certification:

 

 

 

 

 

 

 

 

 

EMI Standards:

 

FCC Class A, CE CISPR A, C-Tick

 

 

 

 

EMC Standards:

 

EN55022, IEC801-2,IEC801-3,IEC801-4

 

 

 

 

Low Voltage Directive:

EN60950

 

 

 

 

 

 

 

Safety Standards:

 

UL, cUL, TUV

 

 

 

 

 

 

Kingston Technology Company

KND2410TX User’s Guide - Rev. A01