Kenmore 153.339432, 153.33955, 153.339372, 153.339482, 153.339572 User Manual

...
0 (0)

Owner’s Manual

POWER MISER™ 9 GAS WATER HEATER

FOR POTABLE WATER HEATING ONLY.

NOT SUITABLE FOR SPACE HEATING.

NOT FOR USE IN MOBILE HOMES.

MODEL NO.

 

 

153.339372

30

Gallon

153.339432

40

Gallon Short

153.339473

40

Gallon

153.339482

40

Gallon (LP)

153.339550

50

Gallon

153.339572

50

Gallon

Safety Instructions

Installation

Operation

Care and Maintenance

Troubleshooting

Parts List

For Your Safety

AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER.

This water heater complies with ANSI Z21.10.1- current edition regarding the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline.

ADVERTENCIA

Si no puede leer o entender el inglés y necesita el manual de instrucciones en español, puede solicitarlo al 1-800-821-2017. NO TRATE DE INSTALAR U OPERAR ESTE CALENTADOR DE AGUA SI NO ENTIENDE LAS INSTRUCCIONES. No hacer caso de esta advertencia podría originar lesiones graves o mortales.

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A

PRINTED IN THE U.S.A 0909

www.sears1 .com

PART NO. 186497-002

SAFE INSTALLATION, USE AND SERVICE

Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater.

Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use or service this water heater.

This is the safety alert symbol. It is used to alert you to potential personal injury hazards.

Obey all safety messages that follow this symbol to avoid possible injury or death.

DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or injury.

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.

CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.

CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.

All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message and how to avoid the risk of injury.

The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances. WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm. This appliance can cause low-level exposure to some of the substances included in the act.

IMPORTANT DEFINITIONS

Qualified Technician: A qualified technician must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting, and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The qualified technician must also be familiar with the design features and use of flammable vapor ignition resistant water heaters, and have a thorough understanding of this instruction manual.

Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing, air supply, venting and gas supply, including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to the installation of gas fired water heaters. The service agency must also have a thorough understanding of this instruction manual, and be able to perform repairs strictly in accordance with the service guidelines provided by the manufacturer.

Gas Supplier: The natural gas or propane utility or service who supplies gas for utilization by the gas burning appliances within this application. The gas supplier typically has responsibility for the inspection and code approval of gas piping up to and including the natural gas meter or propane storage tank of a building. Many gas suppliers also offer service and inspection of appliances within the building.

 

SAFETY PRECAUTIONS

 

 

WARNING

 

 

FIRE AND EXPLOSION HAZARD

 

 

Can result in serious injury or death

 

 

Do not store or use gasoline or other

 

 

flammable vapors and liquids in the vicinity of this

 

 

or any other appliance. Storage of or use of

FLAMMABLES

Flammable Vapors

gasoline or other flammable vapors or liquids in the

vicinity of this or any other appliance can result in

 

 

serious injury or death.

Read and follow water heater warnings and instructions.

© Sears, Roebuck and Co.

2

Kenmore 153.339432, 153.33955, 153.339372, 153.339482, 153.339572 User Manual

Fire or Explosion Harzard

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Avoid all ignition sources if you smell Natural or LP gas.

Do not expose water heater control to excessive gas pressure.

Use only gas shown on rating plate.

Maintain required clearances to combustibles.

Keep ignition sources away from faucets after extended period of non-use.

Read instruction manual before installing, using or servicing water heater.

Breathing Hazard - Carbon Monoxide Gas

Install vent system in accordance with codes.

Do not operate water heater if flood damaged

High altitude orifice must be installed for operation above 7,700 feet (2,347m).

Do not operate if soot is present.

Do not obstruct water heater air intake with insulating jacket.

Do not place chemical vapor emitting products near water heater.

Gas and carbon monoxide detectors are available.

Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual.

3

TABLE OF CONTENTS

 

SAFE INSTALLATION, USE AND SERVICE .................................................................................................

2

SAFETY PRECAUTIONS ...........................................................................................................................

2-3

PRODUCT WARRANTY ................................................................................................................................

6

CUSTOMER RESPONSIBILITIES.................................................................................................................

7

PRODUCT SPECIFICATIONS ......................................................................................................................

8

MATERIALS AND BASIC TOOLS NEEDED..................................................................................................

9

TYPICAL INSTALLATION ............................................................................................................................

10

IMPORTANT INFORMATION ABOUT THIS WATER HEATER ....................................................................

11

Installation Checklist ................................................................................................................................................

11

INSTALLATION INSTRUCTIONS ...........................................................................................................

12-15

Removing the Old Water Heater.............................................................................................................................

12

Location Requirements...........................................................................................................................................

13

Site Location ...........................................................................................................................................................

13

Insulation Blankets..................................................................................................................................................

14

Clearances and Accessibility .............................................................................................................................

14-15

Filling the Water Heater ..........................................................................................................................................

15

GAS SUPPLY..........................................................................................................................................

15-16

Gas Requirements..................................................................................................................................................

15

Gas Piping ..............................................................................................................................................................

15

Gas Pressure..........................................................................................................................................................

16

Gas Pressure Testing..............................................................................................................................................

16

LP Gas Only............................................................................................................................................................

16

COMBUSTION AIR SUPPLY & VENTILATION ......................................................................................

17-20

Unconfined Space...................................................................................................................................................

17

Confined Space ......................................................................................................................................................

17

All Air from Inside the Building...........................................................................................................................

17-18

All Air from Outdoors...............................................................................................................................................

18

Louvers and Grilles............................................................................................................................................

18-19

Vent Pipe System ...................................................................................................................................................

19

Draft Hood Installation ............................................................................................................................................

19

Vent Pipe Size ........................................................................................................................................................

19

Vent Connectors ................................................................................................................................................

19-20

Chimney Connection...............................................................................................................................................

20

Vertical Exhaust Gas Vent ......................................................................................................................................

20

WATER SYSTEM PIPING.......................................................................................................................

21-22

Piping Installation....................................................................................................................................................

21

Closed System/Thermal Expansion........................................................................................................................

22

Temperature and Pressure Relief Valve .................................................................................................................

22

T&P Relief Valve and Pipe Insulation........................................................................................................................

22

4

OPERATING YOUR WATER HEATER ...................................................................................................

23-25

Lighting Instructions................................................................................................................................................

23

Checking the Draft ..................................................................................................................................................

24

Burner Flames ........................................................................................................................................................

24

Emergency Shut Down ...........................................................................................................................................

24

Water Temperature Regulation ..........................................................................................................................

24-25

SERVICE AND ADJUSTMENT ...............................................................................................................

26-28

Tank (Sediment) Cleaning ......................................................................................................................................

26

Vent System Inspection ..........................................................................................................................................

26

Burner Inspection....................................................................................................................................................

26

Burner Cleaning......................................................................................................................................................

26

Housekeeping .........................................................................................................................................................

27

Anode Rod Inspection ............................................................................................................................................

27

Temperature-Pressure Relief Valve Operation .......................................................................................................

27

Draining and Flushing........................................................................................................................................

27-28

Service ....................................................................................................................................................................

28

MAINTENANCE OF YOUR WATER HEATER........................................................................................

29-32

Replacement Parts .................................................................................................................................................

29

External Inspection & Cleaning of the Base-Ring Filter .........................................................................................

29

Removing the Manifold/Burner Assembly...............................................................................................................

29

Removing the Burner from the Manifold/Burner Assembly ....................................................................................

29

Replacing the Thermocouple.............................................................................................................................

29-30

Replacing the Pilot/ Pilot Tube Assembly ...............................................................................................................

30

Cleaning the Combustion Chamber and Flame-arrestor........................................................................................

30

Replacing the Manifold/Burner Assembly...............................................................................................................

31

Piezoelectric Igniter System ...................................................................................................................................

31

Testing the Igniter System ......................................................................................................................................

32

Removing and Replacing the Gas Control Valve/Thermostat ................................................................................

32

FVIR System Operational Checklist .......................................................................................................................

32

TROUBLESHOOTING GUIDE................................................................................................................

33-35

Start Up Conditions............................................................................................................................................

33-34

Operational Conditions ......................................................................................................................................

34-35

TROUBLESHOOTING CHART...............................................................................................................

36-37

PILOT LIGHT TROUBLESHOOTING FLOWCHART...................................................................................

38

PARTS ORDER LIST ...................................................................................................................................

39

5

PRODUCT WARRANTY

9 - YEAR LIMITED WARRANTY ON WATER HEATER

For nine years from the date of purchase, if this water heater is installed and operated in a single-family home in accordance with the owner’s manual instructions and all local applicable plumbing codes, Sears will:

1.Supply free water heater parts for those that are defective in material or workmanship.

2.Supply a free water heater for one that develops a leak.

For the second through the ninth year from the purchase date, you must pay the labor cost for installation of parts or water heater.

For commercial, institutional, industrial or residential use by two or more families, the above limited warranty is only for two years. During the second year you must pay the labor cost for parts or water heater installation.

1 - YEAR EXCLUSIVE KENMORE LABOR WARRANTY

For the first year from the date of purchase, Sears will, free of charge, supply and install new water heater parts for defective ones or a new water heater for one that develops a leak.

WARRANTY SERVICE

To obtain warranty service, call 1-800-4-MY-HOME® (1-800-469-4663). This warranty applies only while this product is in use in the United States.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

SEARS, ROEBUCK AND CO., Dept.817WA, Hoffman Estates, IL 60179

The price of your water heater does not include a free checkup service call. On water heater installations arranged by Sears, Sears warrants the installation.

A charge will be made on service calls due to poor or incomplete installation. These include:

a. Adjusting thermostat

b. Condensation

c. Leaks in pipes or fittings

 

 

 

Master Protection Agreements

Congratulations on making a smart purchase. Your new Kenmore® product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation.

The Master Protection Agreement also helps extend the life of your new product. Here’s what the Agreement* includes:

Parts and labor needed to help keep products operating properly under normal use, not just defects. Our coverage goes well beyond the product warranty. No deductibles, no functional failure excluded from coverage— real protection.

Expert service by a force of more than 10,000 authorized Sears service technicians, which means someone you can trust will be working on your product.

Unlimited service calls and nationwide service, as often as you want us, whenever you want us.

“No-lemon” guarantee – replacement of your covered product if four or more product failures occur within twelve months.

Product replacement if your covered product can’t be fixed.

Annual Preventive Maintenance Check at your request – no extra charge.

Fast help by phone – we call it Rapid Resolution – phone support from a Sears representative on all products. Think of us as a “talking owner’s manual.”

Power surge protection against electrical damage due to power fluctuations.

$250 Food Loss Protection annually for any food spoilage

that is the

result of mechanical failure of any covered

refrigerator or

freezer.

Rental reimbursement if repair of your covered product takes longer than promised.

10% discount off the regular price of any non-covered repair service and related installed parts.

Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online.

The Master Protection Agreement is a risk free purchase. If you cancel for any reason during the product warranty period, we will provide a full refund. Or, a prorated refund anytime after the product warranty period expires. Purchase your Master Protection Agreement today!

Some limitations and exclusions apply. For prices and additional information in the U.S.A. call 1-800-827-6655.

* Coverage in Canada varies on some items. For full details, call Sears Canada at 1-800-361-6665.

Sears Installation Service

For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A. or Canada call 1-800-4-MY-HOME®.

6

CUSTOMER RESPONSIBILITIES

Thank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association

ANSI - American National Standards Institute

NFPA - National Fire Protection Association

ASME - American Society of Mechanical Engineers

GAMA - Gas Appliance Manufacturers Association

Important Information About This Water Heater:

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. New technology used in meeting these standards makes this product more sensitive to installation errors or improper installation environments. Please review the Installation Checklist found at the end of the installation instructions section and make any required installation upgrades or changes.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few pages, READ THE ENTIRE MANUAL

BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/ NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See Figure 1.

Examine the location to ensure the water heater complies with the Installation Instructions section in this manual.

For California installation, this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California’s Office of the State Architect, 1102 Q Street, Suite 5100, Sacramento, CA 95811. Instructions can also be downloaded to your computer at www.dsa.dgs.ca.gov/Pubs.

Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with 40 Ng/J NOx requirements of Texas and most California AQM Districts.

WARNING

Excessive Weight Hazard

Use two or more people to move and install the water heater. Failure to do so can result in injury (including back injury).

IMPORTANT: Do not remove any permanent instructions, labels, or the data label from either the outside of the water heater or on the inside of water heater panels.

Remove exterior packaging and place installation components aside.

Inspect all parts for damage prior to installation and start-up.

Completely read all instructions before attempting to assemble and install this product.

After installation, dispose of/recycle all packaging materials.

7

PRODUCT SPECIFICATIONS

MODEL

TANK CAPACITY

TYPE

INPUT

RECOVERY

MINIMUM

DIAMETER

DIMENSIONS

NUMBER

IN GALS (LTRS)

OF

RATE

RATE GALS.

VENT PIPE

INCHES

INCHES (mm)

 

 

 

(Btu/hr)

 

 

 

GAS

PER HOUR

DIA. INCHES

(mm)

HEIGHT TO

 

 

 

 

 

@ 90°F RISE

(mm)

 

JACKET TOP

153.339372

30 (114)

Natural

35,500

36.34

3 (76) OR 4 (102)

16 (406)

58.00 (1473)

153.339432

40 (151)

Natural

40,000

40.94

3 (76) OR 4 (102)

20 (508)

47.75 (1213)

153.339473

40

(151)

Natural

40,000

40.94

3 (76) OR 4 (102)

18 (457)

58.14 (1477)

153.339482

40

(151)

Propane

36,000

36.85

3 (76) OR 4 (102)

18 (457)

58.14 (1477)

 

 

 

(L.P.)

 

 

 

 

 

153.339550

50 (189)

Natural

50,000

51.18

4 (102)

20 (508)

57.28 (1455)

153.339572

50 (189)

Natural

40,000

40.94

3 (76) OR 4 (102)

20 (508)

57.28 (1455)

8

MATERIALS AND BASIC TOOLS NEEDED

MATERIALS NEEDED

To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materials, depending on your type of installation.

EXPANSION TANKS FOR THERMAL EXPANSION CONDITIONS AVAILABLE IN 2 GALLONS

(7.6 LITERS) AND

5 GALLONS (18.9 LITERS) CAPACITY THROUGH LOCAL SEARS STORE OR SERVICE CENTER.

WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3/4”

(19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER PLUMBING AND FLEXIBLE WATER HEATER GAS CONNECTOR WITH FITTINGS.

METAL DRAIN PANS AVAILABLE IN 20” (508 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 18” (457 mm) OR

LESS, 24” (610mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 22” (559 mm)

OR LESS AND AVAILABLE IN 28” (711 mm) DIAMETER FOR WATER HEATERS HAVING A DIAMETER 26” (660 mm) OR LESS.

BASIC TOOLS

You may or may not need all these tools, depending on your type of installation. These tools can be purchased at your local Sears Store.

Pipe Wrenches (2) 14” (356 mm)

Screwdriver

Tin Snips

6’ (1.82 m) Tape or Folding Ruler

Garden Hose

Drill

Pipe Dope or Teflon Tape

SLOT-HEAD SCREWDRIVER

PHILLIPS SCREWDRIVER

ROLL OF TEFLON

TAPE (USE ONLY ON

WATER CONNECTIONS)

DRILL

TIN SNIPS

PIPE DOPE

(SQUEEZE TUBE)

USE FOR WATER AND GAS

CONNECTIONS

GARDEN HOSE

6 FOOT TAPE

PIPE WRENCH

ADDITIONAL TOOLS NEEDED

WHEN SWEAT SOLDERING

Tubing Cutters or Hacksaw

Propane Tank

Soft Solder

Solder Flux

Emery Cloth

Wire Brushes

 

PROPANE

TUBING CUTTER

TORCH

 

ROLL OF

HACKSAW

EMERY CLOTH

3/4” (19 mm) WIRE BRUSH

 

 

 

ROLL OF LEAD-FREE

SOLDER

1/2” (13 mm) WIRE BRUSH

SOFT SOLDER

FLUX

9

TYPICAL INSTALLATION

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A

Vent Pipe

J

Inner Door

S

Gas Control Valve/Thermostat

B

Draft Hood

K

Outer Door

T

Drain Valve

C

Anode (Not Shown)

L

Union

U

Pilot and Main Burner

D

Hot Water Outlet

M

Inlet Water Shut-off Valve

V

Flue

E

Insulation

N

Cold Water Inlet

W

Metal Drain Pan

F

Gas Supply Piping

O

Inlet Dip Tube

X

Piezo Igniter

G

Manual Gas Shut-off Valve

P

Temperature-Pressure Relief Valve

Y

Base-Ring Filter

H

Ground Joint Union

Q

Rating Plate

 

 

I

Drip Leg (Sediment Trap)

R

Flue Baffle

 

 

*INSTALLINACCORDANCE WITH LOCAL CODES.

* DRIP LEG AS REQUIRED

 

 

 

(S) GAS CONTROL VALVE/

BY LOCAL CODES.

 

 

 

THERMOSTAT: WHITE-RODGERS

TO VENT

 

 

 

GAS CONTROL KNOB

 

 

 

 

 

 

 

TERMINATION ON

 

 

 

 

 

 

ROOF

 

 

 

 

 

 

A

INSTALL THERMAL EXPANSION

 

 

 

 

 

TANK IF WATER HEATER

 

 

 

 

 

IS INSTALLED IN A

 

 

 

 

 

CLOSED WATER SYSTEM

 

 

 

 

 

 

 

WATER TEMPERATURE DIAL

 

L

M

N

 

(ADJUSTING DIAL)

 

B

 

 

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

O

VACUUM RELIEF

“OFF”

“PILOT”

“ON”

 

 

 

VALVE

POSITION

POSITION

POSITION

 

 

 

*INSTALL PER

 

 

 

 

 

 

 

 

 

LOCAL CODES

 

 

 

 

 

 

P

 

TOP VIEW

 

 

 

 

 

 

 

E

 

 

 

 

 

 

R

 

 

 

(U) MANIFOLD/BURNER ASSEMBLY

 

 

 

 

MAIN BURNER

 

 

 

 

THERMOCOUPLE

 

 

 

 

PILOT TUBE

 

 

 

Q

IGNITER WIRE

 

 

 

 

 

 

 

 

MANIFOLD TUBE

F

 

 

 

MANIFOLD DOOR

 

 

 

 

G

 

 

 

 

 

 

 

 

DISCHARGE PIPE

H

 

 

 

(DO NOT CAP OR PLUG.)

 

 

X

 

 

 

V

 

 

 

 

S

 

 

 

 

T

 

I

U

 

 

6” MAXIMUM

 

 

 

 

 

 

 

AIR GAP

W

Y

 

 

FLOOR DRAIN

J

 

 

 

 

 

 

 

 

K

 

 

*ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.

FIGURE 1.

10

instructions (See “Water Temperature Regulation” section).
Gas Supply and Piping
Gas type is the same as that listed on the water heater rating plate.
Gas line equipped with shut-off valve, union, and drip leg.
Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases.
Adequate pipe size and approved pipe material.
An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. Correct any leak found.
Mixing valve (when applicable) installed per manufacturer’s
Closed system pressure build-up devices installed.
All piping properly installed and free of leaks.
Heater completely filled with water.
correctly.
Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.
Flue baffle properly positioned in the flue tube.
Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the “Combustion Air Supply and Ventilation” section of this water heater manual for specific requirements.
Recheck for sufficient combustion air supply.
Water System Piping
Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

IMPORTANT INFORMATION ABOUT THIS WATER HEATER

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Sears at 1-800-4-MY-HOME (1-800-469-4663).

Installation Checklist

Water Heater Location

Water heater location is important and can affect system performance. Please check the following:

Installation area free of corrosive elements and flammable materials.

Centrally located with the water piping system (For new installations). Located as close to the gas piping and vent pipe system as possible.

Located indoors and in a vertical position. Protected from freezing temperatures.

Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

Water heater not located near an air moving device.

Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)? If so, the base-ring filter located on the bottom of the water heater will need to be cleaned periodically. Refer to the “Maintenance of your Water Heater” section of this manual for information on cleaning the base-ring filter.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air for the combustion of gas will result in the flame becoming “lazy”, thereby allowing heat to build up in the combustion chamber. This excessive heat will cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

Fresh air openings must be sized correctly with consideration given to the blocking effect of louvers and grilles.

Ductwork must be the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood. Refer to the “Checking the Draft” section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following:

Draft hood properly installed.

Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

Vent connector made of approved material and sized

Are there openings for make-up air to enter and exit the room/area?

Are the openings of sufficient size? Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the “Installation Instructions” and “Combustion Air Supply and Ventilation” sections for specific requirements.

Make sure that fresh air is not taken from areas that contain negative pressure producing devices such as exhaust fans, dryers, fireplaces, etc.

Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, AirConditioning & Refrigeration (HVAC-R) authorized service provider.

Use a fresh air supply that is free of corrosive elements and flammable vapors.

11

INSTALLATION INSTRUCTIONS

Removing the Old Water Heater

6 1

MANUAL GAS SHUT-OFF VALVE

GROUND

JOINT

UNION

CHECK WITH

LOCAL UTILITY

FOR MINIMUM HEIGHT

3” MINIMUM

DRIP LEG

5 2

DISCHARGE PIPE (DO NOT CAP

OR PLUG)

3

4

6” MAXIMUM AIR GAP

SUITABLE

DRAIN

FIGURE 2.

1.Turn “OFF” the gas supply to the water heater.

If the main gas line shutoff valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leaveallgasappliances

shut “OFF” until the water heater

installation is completed. See FIGURE 3. Figures 2 and 3.

2.

Open a nearby hot water faucet

 

 

 

until the water is no longer hot.

 

 

When the water has cooled, turn

 

 

“OFF”thewatersupplytothewater

 

 

heater at the water shut off valve

 

 

or water meter. Some installations

 

 

require that the water be turned off

FIGURE 4.

 

to the entire house. See Figures 2

 

 

 

and 4.

 

3.Check again to make sure the gas supply is “OFF” to the water heater. Then disconnect the gas supply connection from the gas control valve.

4.Attach a hose to the water heater drain valve and put the other end in a floor drain or outdoors. (See Figures 2 and 5.) Open the water heater drain valve. The water passing out of the drain valve may be extremely hot. To avoid being scalded, make sure all connections are tight and that the water flow is directed away from any person.

FIGURE 5.

5.Disconnect the vent pipe from the draft hood where it connects to the water heater. In most installations the vent pipe can be lifted off after any screw or other attached devices are removed. Dispose of the draft hood. The new water heater has a draft hood which must be used for proper operation.

6.If you have copper piping to the water heater, the two copper water pipes can be cut with a hacksaw approximately four inches away from where they connect to the water heater. See Figure 6. This will avoid cutting off pipes too short. Additional cuts can be made later if necessary. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed.

FIGURE 6.

If you have galvanized pipes to the water heater, loosen the two galvanized pipes with a pipe wrench at the union in each line. Also disconnect the piping remaining to the water heater. See Figure 7. These pieces should be saved since they may be needed when reconnecting the new water heater. Disconnect the temperature-pressure relief valve drain line. When the water heater is drained, disconnect the hose from the drain valve. Close the drain valve. The water heater is now completely disconnected and ready to be removed. Mineral buildup or sediment may have accumulated in the old water heater. This causes the water heater to be much heavier than normal and this residue, if spilled out, could cause staining.

FIGURE 7.

12

Loading...
+ 28 hidden pages