Ice-O-Matic ICEU060 User Manual

4 (1)
Ice-O-Matic ICEU060 User Manual

SERVICE AND INSTALLATION MANUAL ICE UNDERCOUNTER SERIES CUBERS MODEL-ICEU060

Mile High Equipment

11100 East 45th Ave

Denver, Colorado 80239

Part Number 9081291-01

Print Date 11/01

Introduction

ICEU060

To the owner or user: This product manual is a source of information about the installation, start up, cleaning, maintenance, and repair of the product.

Table of Contents

 

Introduction

Page 1

Specifications/Limitations

Page 2

Installation

Page 3-5

Initial Start Up

Page 6

How It Works-Component Description

Page 7

Component Location

Page 8

How It Works-Water System

Page 9

How It Works-Refrigeration

Page 10-11

Operation And Adjustment

Page 12

Sanitizing And Cleaning

Page 13

Service Diagnosis

Page 14

Component Replacement

Page 15-16

Wiring Diagram

Page 17-18

Warranty Information

Page 2

Note the warning symbol where it appears in this manual.

 

It is an alert for important safety information on a hazard

 

that might cause serious injury.

 

Keep this manual for future reference.

 

Ice-O-Matic 11100 E. 45th Ave.

Denver, Co. 80239 800-423-3367

The ICEU060 Service Parts Manual is available separately, Part Number 9081291-02

Page 1

Specifications

ICEU060

Specifications:

 

24 Hour

Bin Storage

Basic

Maximum

Ref Type.

Model Number

Capacity

Capacity

Electrical

Fuse Size

Ounces

ICEU060

55 lbs.

28 lbs.

115/60/1

15

R134a, 9.5 oz

Operating Requirements:

Minimum

Maximum

 

Air Temperature

 

50 F

100 F

 

 

Water Temperature

 

40 F

100 F

 

 

Water Pressure

 

20 PSIG

100 PSIG

 

Voltage

 

103.5 V

126.5 V

 

Ice-O-Matic ice machines are not designed for outdoor installations.

Machine requires voltage indicated on rating nameplate. Failures caused by improper voltage are not considered factory defects. Extended periods of operation at temperatures exceeding limitations constitutes misuse under the terms of the Ice-O-Matic Manufacture’s Limited Warranty, resulting in a loss of warranty coverage. Specifications and design are subject to change without notice.

The ICEU060 ice machine has a 3 year Parts Warranty and a 3 year Labor Warranty. The Compressor and Evaporator have a 5 year Parts Warranty

Ice-O-Matic recommends the installation of water filters.

Page 2

Installation

ICEU060

Location:

Prior consideration for the location of the ice machine shall include:

Installation location to be indoors with a minimum room temperature of 50 F and with a maximum room temperature of 100 F.

The incoming water temperature to the machine should be between 40 F and 100 F.

Service Access. Allow enough space at the rear of the cabinet for the utility connections. Allow enough space for the machine to be pulled out from its installed location. Do not build a floor in front of the machine that would prevent its removal.

Air Circulation. The front panel must remain unobstructed. Do not block the front panel area with any type of door or curtain. The air intake is on the right hand side of the front panel, and the exhaust is on the left side of the front panel and the cabinet left hand side panel. If the unit in installed in a “built-in” cabinet, position the machine so that the left side of the unit is tight against the cabinet.

Page 3

Installation

ICEU060

Water Supply and Drain Connection:

1.The recommend water supply line is ¼ inch O.D. copper tubing. The minimum incoming water pressure should be 20 psig.

2.Connect the water supply tubing to the water inlet fitting (3/4 hose thread) at the rear of the icemaker. An optional adapter (1/4 compression x ¾ hose thread) is available under part number 1011337-43, or from a local hardware store

3.Install a water shutoff valve on the incoming water line near the icemaker so that the water can be shut off for service.

4.Connect a gravity drain line to the drain connection at the icemaker. A minimum slope of ¼ inch fall per foot of horizontal run is recommended. Install the drains per local code. A vent is recommended on the highest point of the drain tube, and the drain tubing must be rigid pipe.

DO NOT use flexible tubing.

Electrical

1.Locate the nameplate on the lower rear panel and check that the location source voltage and capacity are correct for this unit. The unit is supplied with a grounded plug connection.

2.Under no circumstances must the ground post be altered or removed.

3.Be certain that the icemaker is connected to its own electrical circuit and is individually fused.

4.The maximum allowable voltage variation should not exceed ten percent of the name plate rating.

5.All external wiring should conform to the National, State, and local electrical code requirements. Usually an electrical permit and the services of a licensed electrician will be required to install the receptacle.

Page 4

Installation

ICEU060

Final Check:

1.Is the cabinet level?

2.Have all the electrical and piping connection been made?

3.Has the voltage been tested and checked against the nameplate rating?

4.Is the unit plugged into a separate electrical circuit?

5.Is the water supply line shut off valve installed and is the water turned on?

6.Have the bin interior and cabinet exterior been wiped clean?

7.Are all internal components in place including spray platform and curtain?

8.Have the internal refrigerant lines been checked for rubbing and chaffing?

9.Has the machine been installed indoors, in a controlled environment with adequate air circulation around the machine, and where it can be serviced?

Page 5

Loading...